Introduction

Thank you for purchasing the PINTECH High Voltage Differential Probe. We are dedicated to serving you!

Please read this user manual carefully before use and pay attention to safety measures.

Meaning of Symbols

A Warning! Please refer to the user manual before using the instrument. Failure to comply with the instructions or operating before reading this user manual may result in personal injury or damage to equipment and devices.

A Caution! Be careful of electric shock hazards and note the maximum input voltage.

1. Overview

The N1140Apro differential probe provides a safe instrument for all oscilloscopes. It can convert high input differential voltage (≤ 14 kVp-p) into low voltage (≤ 7 V) and display the waveform on the oscilloscope. It operates at frequencies up to 50 MHz, making it ideal for high-power testing, R&D, and maintenance.

The differential probe's output is designed for the oscilloscope's 1 MΩ input impedance with a relative attenuation. When using a 50 Ω impedance matcher, the attenuation is exactly doubled.

It is also recommended to purchase the PL-10 impedance converter produced by PINTECH to extend the application range of the differential probe. This allows for more accurate actual measured voltage values to be observed on the multimeter (oscilloscope accuracy is 3%, digital multimeter is about 3 times more accurate).

It can be widely used in the R&D, debugging, or maintenance of switching power supplies, inverters, electronic ballasts, variable frequency home appliances, and other electrical power devices.

2. Specifications

Bandwidth DC-50 MHz (-3 dB)
Attenuation X100, x 1000
Accuracy ±0.5% (DC-50Hz 1 kHz); ±1% (≥ 1 kHz)
Input Voltage Range ×100: ≤ 1.4 kVp-p or 700 V DC (approx. 490 V RMS)
×1000: ≤ 14 kVp-p or 7000 V DC (approx. 4900 V RMS)
Input Impedance Between terminals: 20 MΩ // 0.5 pF
Single end to ground: 10 MΩ // 1 pF
Output Voltage ≤ 7 V
Oscilloscope Input Impedance 1 MΩ
Rise Time 7 ns
Common Mode Rejection Ratio 60 Hz: > 80 dB; 100 kHz: > 50 dB
Adapter Specified external 6 V DC power supply
Power Consumption Max power consumption 150 mA (0.9 Watts)

Mechanical Specifications

Name Specification
Differential test lead 30 cm / 60 cm
BNC output cable 90 cm
Probe hook BP-368N 122 * 38 * 14.5 mm
Probe dimensions 187 * 83 * 41 mm
Probe weight Approx. 425 g

3. Operating Environment and Conditions

General State During Operation Storage
Temperature +20°C to +30°C 0°C to +50°C -30°C to +70°C
Humidity ≤ 70% RH 20% to 75% RH 10% to 90% RH

Double insulation. Installation Category III. Pollution Degree 2. Related voltage or max grounding: 5000 V RMS. Can be powered by battery or 6 V adapter. Standard adapter included.

4. Operating Procedure

  1. Connect the BP-250 to the output of the N1140Apro and then to the oscilloscope.
  2. Adjust the vertical switch on the oscilloscope if necessary.
  3. Adjust the attenuation ratio and vertical switch on the oscilloscope to the same position.
  4. Estimate the voltage value to be measured before testing. Exceeding the voltage range may damage the probe.
  5. Before turning on the probe, it is best to set the probe gear to maximum. Connect the power adapter to the probe, toggle the power switch, the green light will turn on. When the test voltage exceeds the range, the light will turn red.
  6. Set the oscilloscope's attenuation ratio according to the probe's selected ratio.
  7. Connect the probe hook to the object under test to start measurement.
  8. After the test is completed, turn off the circuit under test first, then turn off the probe switch, disconnect the probe hook from the object under test, and unplug the BNC connector from the oscilloscope.

(Note)

5. Precautions for Use

When measuring, try to wind the input lead. This can better eliminate lead inductance and external noise, improving high-frequency response and anti-interference capabilities. The winding method is shown in the figure below:

[Image: Diagram showing the input leads of the differential probe wound together in a twisted pair configuration.]

Try not to extend the input lead, as this will introduce more noise.

6. Accessories

7. Maintenance

Servicing

When servicing this product, please use tools specified by the original manufacturer. The original manufacturer will not be responsible for repairs made by unauthorized personnel.

Cleaning

This product does not require any specific cleaning. If necessary, use a soft, clean cloth dampened with a small amount of cleaning solution to gently wipe the exterior of the product.

Warranty

Except for intentional human damage, this product is warranted and repairable, but does not include responsibility for safety regulations. The warranty is limited to the replacement of parts and shipping costs, not exceeding the invoice amount. The warranty is only for damage caused by normal operation and does not include any intentional damage, operational errors, mechanical misuse, improper maintenance, overload, or overvoltage. The original manufacturer's warranty is valid for 36 months after sale. If any unauthorized repairs or replacement parts are made, the original manufacturer's warranty will be automatically voided.

Repair

For any repairs, maintenance, or replacement of parts outside of the warranty period, please return the product to the original manufacturer for repair.

8. Packing List

Name Quantity
Differential probe main unit One
Probe hook (BP-368N) A pair
6V Adapter
(W&T-AD1806A060030K)
One
Instruction Manual One copy
Certificate of Conformity One copy

Note: The product accessories are the probe hooks by default. If you need to replace them with other accessories such as alligator clips or IC clips, please contact our sales staff!

PDF preview unavailable. Download the PDF instead.

ABUIABA9GAAg4IacxAYo7-yEhgM WPS 文字

Related Documents

Preview PT-5230 High Voltage Differential Probe - Technical Specifications and Applications
Detailed specifications and application information for the PINTECH PT-5230 high voltage differential probe, designed for measuring high voltage signals with a bandwidth of up to 75 MHz.
Preview PINTECH N1070B High Voltage Differential Probe Instruction Manual
Comprehensive instruction manual for the PINTECH N1070B High Voltage Differential Probe, detailing its specifications, operation, safety precautions, and maintenance for oscilloscopes.
Preview Pintech PT-670 High Voltage Differential Probe Instruction Manual
Instruction manual for the Pintech PT-670 High Voltage Differential Probe, covering installation, operation, safety precautions, specifications, and troubleshooting.
Preview Pintech N Series High-Precision Active Differential Probes Buyer's Guide
A comprehensive guide to Pintech's N Series high-precision active differential probes, detailing their features, specifications, and applications in various electronic testing scenarios.
Preview PINTECH PT-5250 High Voltage Differential Probe Instruction Manual
Comprehensive guide for the PINTECH PT-5250 High Voltage Differential Probe, detailing its features, specifications, safe operation procedures, maintenance, and warranty information for high-voltage measurements up to 50kV.
Preview PINTECH N Series Differential Probes - User Manual and Specifications
Comprehensive user manual and technical specifications for PINTECH N Series Differential Probes, covering operation, safety, maintenance, and detailed model comparisons.
Preview PINTECH N1280Apro 差分探头说明书 | 高压示波器探头技术规格与操作指南
PINTECH N1280Apro 高压差分探头用户手册。了解其详细规格、操作说明、安全注意事项以及配件信息,适用于电力测试、研发和维修。
Preview Pintech PT-630 High Voltage Differential Probe Instruction Manual
Instruction manual for the Pintech PT-630 High Voltage Differential Probe, covering installation, safety precautions, operation, specifications, and troubleshooting.