Thank you for purchasing the PINTECH differential probe. We are dedicated to serving you!
Please read this user manual carefully and observe safety measures before use.
Meaning of Symbols
⚠️ Warning: Refer to the user manual before using the instrument. Failure to comply with the instructions in this manual or operating the instrument before reading it may result in personal injury or damage to equipment and devices.
⚠️ Caution: Risk of electric shock, observe the maximum input voltage.
- Do not use in wet or potentially explosive environments.
- Ensure the circuit is turned off before connecting the probe.
- After measurement, turn off the tested circuit first, then turn off the probe switch.
- Before use, confirm the differential probe is not damaged. If damaged, stop using it.
- Please use the adapter that comes standard with this product.
I. Brief Introduction
The N1070B differential probe provides a safe way for all oscilloscopes to measure high input differential voltage (up to 7000V PEAK TO PEAK) converting it to a low voltage (<7V). It displays the waveform on the oscilloscope and operates at frequencies up to 100MHz, making it ideal for high-power testing, R&D, and repair applications.
The differential probe's output attenuation is designed for the oscilloscope's 1MΩ input impedance. When using a 50Ω matching terminator, the attenuation is doubled.
It is widely used in the R&D, debugging, and maintenance of switching power supplies, inverters, electronic ballasts, variable frequency home appliances, and other electrical power devices.
II. Specifications
Parameter | 100X | 1000X |
---|---|---|
Frequency Bandwidth (-3dB) | DC-40MHz | DC-100MHz |
Attenuation Ratio | 100X, 1000X | |
Accuracy | ±1% | |
Input Voltage Range | ≤700Vp-p or 350V DC (approx. 245V RMS) | ≤7000Vp-p or 3500V DC (approx. 2450V RMS) |
Max Differential Voltage | 7000V (AC PEAK TO PEAK) | |
Input Impedance | Between terminals: 20MΩ // 0.5pF Single-ended to ground: 10MΩ // 1pF |
|
Output Voltage | <7V | |
Oscilloscope Input Impedance | 1MΩ | |
Rise Time | ≥3.5ns | |
Common Mode Voltage | 2450V RMS | |
CMRR | 60Hz: >80dB; 100kHz: >50dB | |
Noise | 100X: <100mV RMS | 1000X: <500mV RMS |
Power Adapter | External 6V DC power supply specified |
Diagram and Mechanical Specifications
Device Diagram: A visual representation of the N1070B probe shows the following components:
- BNC output cable
- OUTPUT 7V MAX indicator
- Power switch
- 6V adapter interface
- Overvoltage Warning Light (Red)
- Power Indicator Light (Green)
- Attenuation Switch
- Banana line input terminal
Mechanical Specifications
Item | Specification |
---|---|
Differential Test Cable | 30cm |
BNC Output Cable | 90cm |
Probe Hook (BP-368N) | 122*38*14.5mm |
Probe Dimensions | 187*83*41mm |
Probe Weight | Approx. 425g |
III. Operating Environment and Conditions
Condition | General State | Operating | Storage |
---|---|---|---|
Temperature | +20℃ to +30℃ | 0℃ to +50℃ | -30℃ to +70℃ |
Humidity | <70%RH | 20% to 75%RH | 10% to 90%RH |
Safety Classifications: Double Insulation, Installation Category III, Pollution Degree 2. Maximum voltage to ground: 5000V RMS.
Power Source: Can be powered by battery or a 6V adapter; the adapter is supplied as standard.
IV. Operating Procedure
- Connect the BP-250 and N1070B output to the oscilloscope.
- Adjust the oscilloscope's vertical scale if necessary.
- Set the oscilloscope's attenuation ratio and vertical scale to match the probe's settings.
- Before testing, estimate the voltage range of the measurement. If it exceeds the voltage range, use a more suitable probe to avoid damaging the probe.
- If unsure of the voltage magnitude, select the highest attenuation range first, and then adjust based on the voltage. Connect the power adapter to the probe and turn on the power switch; the green indicator light will illuminate. If the test voltage exceeds the range, the indicator light will turn red, and you should disconnect immediately.
- Set the oscilloscope's attenuation coefficient and vertical scale according to the probe's range.
- Connect the probe hook to the test object and begin measurement. Keep the probe body as far as possible from high-voltage pulse circuits to reduce interference to the probe.
- After testing, turn off the tested circuit first, then turn off the probe switch. Disconnect the probe hook from the test object and remove the BNC connector from the oscilloscope.
Note:
- Power must be turned on.
- The actual vertical deflection is equal to the attenuation multiplied by the vertical deflection selected on the oscilloscope, and is double for a 50Ω load.
- When connecting the differential probe's BNC output cable to an oscilloscope or other equipment, ensure the BNC connector is properly grounded.
V. Precautions for Use
When measuring, it is advisable to wind the input cables to better suppress lead inductance and external noise, thereby improving high-frequency response and interference immunity. The winding method is illustrated below [textual description of winding: cables are coiled neatly].
Avoid extending the input cables, as this may introduce more noise.
VII. Maintenance
Maintenance
When maintaining this product, please use tools specified by the manufacturer. The manufacturer will not be liable for any repairs performed by unauthorized personnel.
Cleaning
This product does not require any specific cleaning. If necessary, use a soft, clean cloth lightly dampened with a mild cleaning solution to wipe the product's exterior.
Warranty
Except for intentional damage caused by human factors, this product is warranted and repairable, but does not cover responsibilities related to safety regulations.
The warranty is limited to the replacement of parts and shipping costs, not exceeding the invoice amount.
The warranty applies only to damage incurred during normal operation; it does not cover intentional damage, operational errors, improper mechanical handling, or improper maintenance, overload, or overvoltage.
The manufacturer's warranty is valid for 36 months from the date of sale. Any unauthorized repair or replacement of parts by non-original manufacturers will automatically void the warranty.
Repair
For any repairs, maintenance, or part replacements outside the warranty period, please return the product to the manufacturer for repair.
Packing List
Item | Quantity |
---|---|
Differential Probe Main Unit | 1 |
Probe Hook (BP-368N) | 1 Pair |
6V Adapter (W&T-AD1806A060030K) | 1 |
Manual | 1 Copy |
Certificate | 1 Copy |
Note: Probe hooks are shipped as default accessories. If you need to replace them with other accessories, such as alligator clips or IC clips, please contact our sales personnel!
Related Documents
![]() |
PINTECH N1280Apro 差分探头说明书 | 高压示波器探头技术规格与操作指南 PINTECH N1280Apro 高压差分探头用户手册。了解其详细规格、操作说明、安全注意事项以及配件信息,适用于电力测试、研发和维修。 |
![]() |
PINTECH N Series Differential Probes - User Manual and Specifications Comprehensive user manual and technical specifications for PINTECH N Series Differential Probes, covering operation, safety, maintenance, and detailed model comparisons. |
![]() |
Pintech PT-670 High Voltage Differential Probe Instruction Manual Instruction manual for the Pintech PT-670 High Voltage Differential Probe, covering installation, operation, safety precautions, specifications, and troubleshooting. |
![]() |
PINTECH N1008A Differential Probe Instruction Manual Instruction manual for the PINTECH N1008A Differential Probe, detailing its features, specifications, operating procedures, safety precautions, and accessories for high-voltage differential measurements up to 800V peak-to-peak. |
![]() |
PT-5230 High Voltage Differential Probe - Technical Specifications and Applications Detailed specifications and application information for the PINTECH PT-5230 high voltage differential probe, designed for measuring high voltage signals with a bandwidth of up to 75 MHz. |
![]() |
PINTECH N1140Apro High Voltage Differential Probe Instruction Manual Instruction manual for the PINTECH N1140Apro High Voltage Differential Probe, detailing its features, specifications, operation, safety precautions, and maintenance. |
![]() |
PINTECH PT-5250 High Voltage Differential Probe Instruction Manual Comprehensive guide for the PINTECH PT-5250 High Voltage Differential Probe, detailing its features, specifications, safe operation procedures, maintenance, and warranty information for high-voltage measurements up to 50kV. |
![]() |
PINTECH N2008Apro Differential Probe Instruction Manual Instruction manual for the PINTECH N2008Apro High Voltage Differential Probe, covering specifications, operation, precautions, and maintenance. |