Honeywell DT8050AF24-SN V-Plex DUAL TEC Motion Sensor with Anti-Mask - Quick Installation Guide
Installation Overview
This guide provides instructions for the Honeywell DT8050AF24-SN V-Plex DUAL TEC Motion Sensor with Anti-Mask.
Key Features:
- V-Plex® DUAL TEC® technology
- Anti-Mask functionality
- Quick Installation Guide
Mounting and Placement
Diagram 1: Illustrates recommended mounting locations for the sensor, emphasizing keeping the area clear in front of the sensor (at least 30 cm / 12 inches).
Diagram 2: Shows the internal components and wiring connections for the sensor.
Diagram 3: Details the mounting procedure using screws (#6 x 1" / 3.5 mm x 25 mm) and shows how to attach the sensor to a wall or ceiling bracket.
Diagram 4: Explains the sensor's settings, including 'Look-Down Disabled'/'Enabled' and 'Anti-mask Enabled'/'Disabled'. It also shows the adjustment for Microwave Range and Sensitivity.
Wiring and Power
Diagram 5: Shows the wiring for a Polling Loop, 9-13V PK-PK connection, with a note about keeping the sensor clear of masking or reflective material.
Operation and Walk Test
Diagram 6: Details the walk test procedure. It explains how to apply power, initialize the sensor (LED stops flashing), reduce microwave range if necessary, and walk through the detection area to observe the LED.
LED Indicators: A table explains the LED behavior during Power Up, Walk Test, Normal, Trouble, and Anti-Mask modes for Red, Yellow, and Green LEDs.
Walk Test Mode: The walk test mode is active for 10 minutes and automatically exits. It can be re-enabled using a flashlight feature for an additional 10 minutes.
Zone Coverage Diagram
Diagram 7: Provides a visual representation of the sensor's detection zones (A, B, C, D) and their corresponding coverage distances in meters and feet. It includes top and side views of the coverage pattern.
- Zone A (2): Look-down / Basses / Vista Zona 0 / Vigilância inferior
- Zone B (12): Lower / Courtes / Cercana / Mais baixas
- Zone C (10): Intermediate / Intermédiaires / Intermedia / Intermédias
- Zone D (36): Long / Longues / Largo Alcance / Longo alcance
Troubleshooting
A troubleshooting section provides guidance on common issues, including:
- Masking: Sensor IR window is blocked or masked.
- Self-Test Failure: Microwave supervision failure, PIR self-test failure, or temperature compensation failure.
Corrective actions include verifying the sensor is not blocked, cycling power, performing a walk test, and replacing the sensor if the issue persists.
Specifications
- Electrical Ratings: 9.5 - 15VDC, Max. 25 mA at 9.5VDC; Max. 16 mA at 15 VDC.
- Operating Temperature: 14° to 131 °F (-10° to 55°C)
- Relative Humidity: 5 to 93% (non-condensing)
Approvals and Listings
- FCC part 15, Class B verified
- IC ICES-003, Class B verified
- UL 639
- ULC S306-03
Compliance and Safety Information
Federal Communications Commission (FCC) Statements: Includes information on FCC requirements for Class B digital devices and potential interference.
Industry Canada Class B Statement: Compliance with Canadian ICES-003.
FCC Supplier's Declaration of Conformity: Details the responsible party (Honeywell International Inc.) and compliance with FCC Part 15 rules.
RF Exposure Warning: Advises on maintaining a minimum separation distance of 20 cm (7.8 inches) from the radiator to all persons.
General Installation Notes: All wiring must comply with National Electrical Code, Canadian Electrical Code, UL standards, and local codes. Products are intended to be powered by a power-limited output of a UL/CUL Listed Burglar Alarm control unit or a Listed UL2610/UL603/ULC-S318 power supply.
UL Notes: All interconnecting devices must be UL Listed. The anti-mask feature has not been evaluated by UL.
For patent information, visit: www.honeywell.com/patents
For the latest documentation and online support, visit: https://buildings.honeywell.com/us/en/products/by-category/sensors/motion-detectors/dual-tec-24g-motion-sensor and https://myhoneywellbuildingsuniversity.com/training/
For warranty information, contact your local authorized Honeywell representative or visit: www.honeywell.com/security/hsc/resources/wa
Contact Information:
- Honeywell Building Automation
- Commercial Security
- 715 Peachtree St NE
- Atlanta, GA 30308-2179
- 1.800.323.4576