Kingfisher Steel Panel Radiator

Model: 5059340419039

Product Type: Steel Panel Radiator

Manufacturer: Kingfisher International Products

Introduction

These instructions are for your safety. Please read through them thoroughly prior to handling the product and retain them for future reference.

(French: Ces instructions sont données pour votre sécurité. Merci de les lire attentivement avant de manipuler le produit et de les conserver pour référence.)

Parts List

01. Radiator Unit (x1): The main steel panel radiator body.

02. Brackets (x4-6): Wall mounting brackets.

03. Purge Plug (x2-3): Used for bleeding air from the radiator.

04. Blind Plug (x1): Seals unused radiator ports.

05. Wall Fixings (x4-6): Screws and wall plugs for securing brackets.

06. Wall Brackets (x4-6): Additional wall mounting components.

07. Wall Brackets (x4-6): Further wall mounting components.

08. Thermostatic Valve (x1): Valve for controlling radiator temperature (may be sold separately).

You Will Need

  • Assistance (x1-2 people recommended)
  • Drill with appropriate drill bit (e.g., Ø8 mm)
  • Spirit level
  • Phillips head screwdriver
  • Adjustable wrench or spanner
  • PTFE tape for sealing threads
  • Protective gloves
  • Safety glasses
  • Pencil for marking
  • 8mm socket or spanner

Technical Specifications & Dimensions

Panel radiators comply with EN 442 standards and are manufactured under quality management systems approved by EN ISO 9001, EN ISO 14001, and ISO 45001.

Maximum operating pressure: 10 Bars

Maximum operating temperature: 120°C

Type Type 11 Type 21/22 Type 11/21/22
L (mm) X (mm) No. of Brackets W (mm) L (mm) X (mm) No. of Brackets W (mm) H (mm) Y (mm) Z (mm)
300 117 4 400 101 4 400 120 85
400 117 4 500 101 4 500 120 185
500 117 4 600 101 4 600 120 285
600 117 4 700 101 4 700 120 385
700 117 4 800 101 4 700 120 485
800 117 4 900 101 4 900 117 N/A
900 117 4 1000 101 4 1000 117 N/A
1000 117 4 1100 101 4 1100 117 4
1100 117 4 1200 101 4 1200 117 4
1200 117 4 1400 101 4 1400 117 4
1400 117 4 1600 101 4 1600 117 4
1600 117 4 1800 101 6 1800 117 6
1800 117 6 2000 101 6 2000 101 900
2000 117 6 1000

Safety Instructions

Before You Start

  • Check that all components are present and that you are entirely happy with the size, design, and finish before starting installation.
  • Blind plug, purge plug, and fastenings are included in the package. Remove the package from the bottom of the radiator, taking care not to damage the paint.
  • If any parts are missing or damaged, contact the supplier immediately.
  • Radiators must be installed using the supplied brackets.
  • Fixings are for solid walls. For hollow walls (e.g., plasterboard), fix to internal timbers or use appropriate fixings.
  • Before drilling or fixing, check for pipes and wires in walls, floors, or ceilings.
  • Remove and dispose of plastic caps from threaded connections before installation.
  • Position the radiator for easy connection to the central heating system. Use dimensioned sketches to drill holes correctly.
  • Radiator valves are not supplied and must be installed. A thermostatic valve is recommended for comfort and economy.
  • Fitting reflective panels behind the radiator can improve efficiency.

Safety

  • Never allow unsupervised use by children or persons unable to operate the appliance safely.
  • Dispose of plastic bags carefully and keep them away from children.
  • Be aware that the contents may include small/sharp components; handle with care and keep away from children.
  • Lift the radiator using correct posture, holding from both ends. Seek assistance if too heavy.

Warning

  • Once fitted, the radiator requires plumbing and commissioning into a central heating system. Seek professional advice if unsure.
  • Panel radiators must always contain water. Dehydrated radiators can corrode and perforate. Frequent water changes with oxygen-rich water accelerate corrosion.
  • Do not use panel radiators in outdoor areas. Ambient temperature should not fall below 0°C to prevent freezing damage.
  • This radiator is not recommended for centralized national heating systems. Use in such systems may reduce warranty to 2 years due to potential corrosion.
  • Read and understand all instructions before fitting.
  • The radiator surface can reach very high temperatures; it is not suitable for environments with risks. Keep children and persons with disabilities supervised near the radiator.
  • Do not hang heavy objects or lean body weight against the radiator.
  • Never cover the top of the radiator, as this reduces heating efficiency and air circulation. Wet clothes can cause corrosion.

Important Notes

  • Read and follow all safety and operating instructions before use.
  • Store radiators in dry, closed conditions, protected from external elements (rain, snow, sun).
  • Do not remove shrink-wrap packaging until the radiator is ready for wall fitting. Radiators with plaster or paint applied cannot be cleaned or restored.
  • Installation should be carried out by a qualified professional in accordance with relevant British and European Standards (BS7593:2006 & EN14336:2004).
  • This radiator is made from mild steel and is susceptible to corrosion. Use only in systems with a chemical inhibitor. Apply the correct inhibitor after installation as per manufacturer guidelines. Maintain correct water pressure. Consult a plumber if unsure.
  • This radiator is not suitable for 'direct central heating systems' (where hot water is also used for taps) as inhibitors cannot be added. Use aluminium or stainless steel radiators for such systems. Consult a plumber if unsure.
  • Isolate the central heating system before any work.
  • Use correct tools and fittings, and wear necessary PPE.

Guarantee

Kingfisher offers a 15-year manufacturer's guarantee against manufacturing defects from the date of purchase or delivery for normal household use.

To claim, present proof of purchase. The guarantee applies to new products only. Replacement products are guaranteed until the expiry of the original period.

This guarantee covers product failures provided the product is used as intended and subject to installation, cleaning, care, and maintenance in accordance with the manual and standard practice. It does not cover normal wear and tear, misuse, faulty installation, or accidental damage.

Ancillary costs (shipping, labour, etc.) are not covered. Defective products will be replaced or refunded within a reasonable time.

Guarantee rights are enforceable in the country of purchase. Contact the store of purchase for guarantee-related queries. This guarantee is in addition to, and does not affect, your statutory rights.

(French legal information regarding conformity and hidden defects in France is also provided but summarized here in English for conciseness.)

IMPORTANT: RETAIN THIS INFORMATION FOR FUTURE REFERENCE: READ CAREFULLY

Assembly Instructions

Step 01: Wall Bracket Placement

Determine the correct bracket type (T11, T21, or T22) based on the radiator model. Mark the wall according to the specific dimensions provided for each type (e.g., for T11: 84±2mm, 48±2mm, 31±2mm vertical spacing). Ensure a minimum clearance of 110 mm from the wall.

Step 02: Prepare Brackets and Radiator

Attach the wall brackets (02) to the radiator unit. Insert the purge plug (03) into the appropriate port.

Step 03: Mark and Drill Holes

Using the spirit level and pencil, mark the drilling points on the wall based on the bracket positions. Drill holes of Ø8 mm, ensuring a depth suitable for the wall fixings. A 60 mm measurement is indicated for certain drilling depths.

Step 04: Secure Brackets to Wall

Insert wall plugs (06) into the drilled holes. Secure the wall brackets (02, 06, 07) to the wall using the provided screws (07).

Step 05: Hang Radiator

Carefully lift the radiator and hang it onto the secured wall brackets.

Step 06: Final Radiator Attachment

Ensure the radiator unit (01) is securely seated on all brackets.

Step 07: Install Radiator Valve

Mount the thermostatic radiator valve (04) and the bleed valve (05) onto the radiator ports. Tighten fittings to approximately 10 Nm.

Step 08: Commissioning

Open the radiator valve to allow hot water circulation from the central heating system. Check if the radiator warms up. If not, bleed any trapped air from the radiator using the bleed valve until water emerges. If problems persist, contact authorized service support.

Care and Maintenance

After Use

Wipe the radiator surface clean with a soft, damp cloth. Never use solvents, scourers, abrasives, bleach, acids, strong detergents, aggressive chemical cleaners, or solvent-based cleaning solutions.

When disposing of the radiator, send it to a metal recycling centre according to local regulations.

To avoid product returns, check with the store for the availability of spare parts if any are missing or damaged.

Prohibited cleaning methods:

  • ❌ Spraying with harsh chemicals
  • ❌ Using abrasive pads or scourers
  • ❌ Using harsh cleaning solutions on a sponge

Manufacturer Information

UK Manufacturer: Kingfisher International Products Limited, 3 Sheldon Square, London, W2 6PX, United Kingdom

EU Manufacturer: Kingfisher International Products B.V., Rapenburgerstraat 175E, 1011 VM Amsterdam, The Netherlands

Websites:

To view instruction manuals online, visit www.kingfisher.com/products.

Models: Type 22 Double-Panel Double Convector Radiator, Double Convector Radiator, Convector Radiator, Type 22 Double-Panel, Radiator

PDF preview unavailable. Download the PDF instead.

pa 2640218 Adobe InDesign 16.0 (Windows) Adobe PDF Library 15.0

Related Documents

Preview Steel Panel Radiator Installation, Operation, and Maintenance Manual
This manual provides comprehensive instructions for the safe installation, operation, and maintenance of steel panel radiators. It includes product descriptions, technical specifications, safety guidelines, assembly steps, and warranty information.
Preview Steel Panel Radiator Installation and Maintenance Manual
Comprehensive guide for installing, operating, and maintaining steel panel radiators, including safety instructions, technical specifications, and warranty information.
Preview Steel Panel Radiator Installation and Maintenance Manual
Comprehensive guide for installing, operating, and maintaining steel panel radiators, including safety instructions, technical specifications, and warranty information. Covers product features, assembly steps, and care instructions.
Preview Flomasta Type 21 Double-Panel Plus Single Convector Radiator - Installation and Care Manual
Comprehensive instructions for installing, using, and maintaining your Flomasta Type 21 Double-Panel Plus Single Convector Radiator. Includes safety guidelines, parts list, dimensions, assembly steps, and warranty information.
Preview Kingfisher D002A-10L Dehumidifier: User Manual & Operation Guide
Discover the Kingfisher D002A-10L dehumidifier. This comprehensive manual offers essential operating instructions, safety guidelines, maintenance advice, and troubleshooting tips for effective moisture control in your home. Learn about its 10L/day capacity, R290 refrigerant, and user-friendly features.
Preview Flexible PVC Greenhouse with 8 Shelves - Assembly and Safety Instructions
Comprehensive guide for assembling and safely using a flexible PVC greenhouse with 8 integrated shelves. Includes safety precautions, maintenance tips, and distributor information.
Preview Kingfisher Decorative TRV and Lockshield Installation and Operating Manual
Comprehensive guide for installing and operating Kingfisher Decorative Thermostatic Radiator Valves (TRVs) and Lockshields. Includes technical data, safety information, and step-by-step instructions for optimal home heating control.
Preview Kingfisher 3-Drawer Base Cabinet Assembly and Installation Guide
A comprehensive guide for assembling and installing the Kingfisher 3-drawer base cabinet. Includes multilingual instructions, safety warnings, parts list, and warranty information.