Installation and Maintenance Manual
Brand: Kingfisher
Product Codes: 5059340419046, 5059340419053, 5059340419060, 5059340419077, 5059340419084, 5059340419091, 5059340419107, 5059340419114, 5059340419121, 5059340419138, 5059340419145, 5059340419152, 5059340419169, 5059340419176, 5059340419183, 5059340419190, 5059340419206, 5059340419213, 5059340419220, 5059340419237, 5059340419244, 5059340419251, 5059340419268, 5059340419305, 5059340419312, 5059340419329, 5059340419336, 5059340419343, 5059340419350, 5059340419367, 5059340419374, 5059340419398, 5059340419404, 5059340419411, 5059340419428, 5059340419435, 5059340419442, 5059340419510, 5059340419527, 5059340419534, 5059340419541, 5059340419558, 5059340419565, 5059340419572, 5059340419596, 5059340419640, 5059340419657, 5059340419664, 5059340419671, 5059340419688, 5059340419695, 5059340420301, 5059340420318, 5059340420325, 5059340420332, 5059340420349, 5059340420356, 5059340420363, 5059340420370, 5059340420387, 5059340420394, 5059340420400, 5059340420417, 5059340420424, 5059340420431, 5059340420448, 5059340420455, 5059340420462, 5059340420479, 5059340420486, 5059340420493, 5059340420509, 5059340420516, 5059340420738, 5059340420745, 5059340420752, 5059340420769, 5059340420776, 5059340420783, 5059340420790, 5059340420806, 5059340420813, 5059340420820, 5059340420837, 5059340420844, 5059340420851, 5059340420868, 5059340420875, 5059340420882, 5059340420899, 5059340420905, 5059340420912, 5059340420929, 5059340420936, 5059340420943, 5059340420950, 5059340420967, 5059340420974, 5059340420981, 5059340420998, 5059340421001, 5059340421018, 5059340421025, 5059340421032, 5059340421049, 5059340421056, 5059340421063, 5059340421070, 5059340421087, 5059340421094, 5059340421100, 5059340421117, 5059340421124, 5059340421131, 5059340421148, 5059340421155, 5059340421162, 5059340421179, 5059340421186, 5059340421193, 5059340421209, 5059340421216, 5059340421223, 5059340421230, 5059340421247, 5059340421254, 5059340421261, 5059340421278, 5059340421285, 5059340421292, 5059340421308, 5059340421315, 5059340421322, 5059340421339, 5059340421346, 5059340421353, 5059340421360, 5059340421377, 5059340421384, 5059340421391, 5059340421407, 5059340421414, 5059340421421, 5059340421438, 5059340421445, 5059340421452, 5059340421469, 5059340421476, 5059340421483, 5059340421490, 5059340421506, 5059340421513, 5059340421520, 5059340421537, 5059340421544, 5059340421551, 5059340421568, 5059340421575, 5059340421582, 5059340421599, 5059340421605, 5059340421612, 5059340421629, 5059340421636, 5059340421643, 5059340421650, 5059340421667, 5059340421674, 5059340421681, 5059340421698, 5059340419701, 5059340419718, 5059340419725, 5059340419732, 5059340419749, 5059340419756, 5059340419763, 5059340419770, 5059340419787, 5059340419794, 5059340419800, 5059340419817, 5059340419824, 5059340419831, 5059340419848, 5059340419855, 5059340419862, 5059340419879, 5059340419886, 5059340419985, 5059340419992, 5059340420004, 5059340420011, 5059340420028, 5059340420035, 5059340420042, 5059340420059, 5059340420066, 5059340420073, 5059340420080, 5059340420097, 5059340420103, 5059340420110, 5059340420127, 5059340420134, 5059340420141, 5059340420158, 5059340420165, 5059340420172, 5059340420189, 5059340420196, 5059340420202, 5059340420219, 5059340420226, 5059340420233, 5059340420240, 5059340420257, 5059340420264, 5059340420271, 5059340420288, 5059340420295
Panel radiators comply with EN 442 standards and are manufactured under quality management systems approved by EN ISO 9001 (environmental management) and ISO 45001 (occupational health and safety). The maximum operating pressure is 10 Bars, and the maximum operating temperature is 120°C.
The radiator dimensions are indicated in the diagram below. Key dimensions include L (length), X (distance from end to bracket), W (width), H (height), Y (distance from top to bracket), and Z (distance from bottom to bracket).
[Diagram showing radiator dimensions with labels L, X, W, H, Y, Z]
L (mm) | X (mm) | No. of Brackets | W (mm) |
---|---|---|---|
400 | 117 | 4 | |
500 | 117 | 4 | |
600 | 117 | 4 | |
700 | 117 | 4 | |
800 | 117 | 4 | |
900 | 117 | 4 | N/A |
1000 | 117 | 4 | |
1100 | 117 | 4 | |
1200 | 117 | 4 | |
1400 | 117 | 4 | |
1600 | 117 | 4 | |
1800 | 117 | 6 | 883,335 |
L (mm) | X (mm) | No. of Brackets | W (mm) |
---|---|---|---|
400 | 101 | 4 | |
500 | 101 | 4 | |
600 | 101 | 4 | |
700 | 101 | 4 | |
800 | 101 | 4 | |
900 | 101 | 4 | N/A |
1000 | 101 | 4 | |
1100 | 101 | 4 | |
1200 | 101 | 4 | |
1400 | 101 | 4 | |
1600 | 101 | 4 | |
1800 | 101 | 6 | |
2000 | 101 | 6 | 1000 |
H (mm) | Y (mm) | Z (mm) |
---|---|---|
300 | 120 | 85 |
400 | 120 | 185 |
500 | 120 | 285 |
600 | 120 | 385 |
700 | 120 | 485 |
[Diagram of radiator and parts]
[Diagram of tools and materials]
[Diagram showing wall mounting points and dimensions for radiator types T11, T21, T22. Dimensions like 84±2/99±2 mm, 48±2/63±2 mm, 31±2/46±2 mm, 53±2 mm, 70±2 mm, 104±2 mm are indicated. Minimum clearance of 110 mm from the wall is shown.]
Select the appropriate mounting positions based on your radiator type (T11, T21, T22) and the required dimensions. Ensure a minimum clearance of 110 mm from the wall.
[Diagram showing parts 02 (brackets) and 03 (screws/plugs). A close-up shows how part 02 and 03 fit together.]
Identify the wall brackets (02) and fixing screws/plugs (03).
[Diagram showing a hand using a drill to make holes in a brick wall. A pencil is used to mark positions. A close-up shows a drill bit of Ø8 mm. Wall plugs (06) are shown being inserted into the holes.]
Mark the drilling points on the wall according to the chosen mounting positions. Drill holes using an 8mm drill bit. Insert the wall plugs (06) into the drilled holes.
[Diagram showing brackets being attached to the wall using screws (07) and a wrench. The brackets are shown mounted on the wall plugs.]
Secure the wall brackets (02) to the wall using the fixing screws (07) and a wrench. Ensure they are firmly attached.
[Diagram showing a spirit level being used on the mounted brackets to ensure they are horizontal.]
Use a spirit level to ensure the brackets are perfectly horizontal before proceeding.
[Diagram showing the radiator unit (01) being lifted and attached to the mounted wall brackets.]
Carefully lift the radiator unit (01) and hang it onto the wall brackets.
[Diagram showing the installation of radiator valves (parts 04 and 05) onto the radiator. An indication of 10Nm torque is shown for valve tightening.]
Install the thermostatic valve (04) and lockshield valve (05) onto the radiator. Tighten to approximately 10Nm.
Open the radiator valve and ensure the central heating system is operating.
Check if the radiator is getting warm. If not, carefully loosen the bleed valve with a bleed key or screwdriver to release any trapped air until water starts to come out. In case of persistent problems, contact authorized service support.
Wipe the surface clean with a soft, damp cloth. Never use solvents, scourers, abrasives, bleach, acids, strong detergents, aggressive chemical cleaners, or solvent-type cleaning solutions on the product.
[Diagram illustrating cleaning methods. A checkmark (✔️) indicates cleaning with a damp cloth. Crosses (❌) indicate forbidden methods: using solvents, scourers, abrasives, bleach, acids, strong detergents, or aggressive chemical cleaners.]
When disposing of this radiator, send it to a metal recycling centre and follow your local regulations.
To prevent issues when returning a product, check with the store if spare parts for missing or damaged components are available.
This product has a manufacturer's guarantee of 15 years against manufacturing defects from the date of purchase (in-store) or delivery (online), for normal household use. This guarantee is in addition to your statutory rights.
To make a claim, present your proof of purchase. The product must be new; it does not apply to second-hand or display items. The guarantee covers product failures provided the product was used as intended and maintained according to the manual and standard practice. It does not cover normal wear and tear, improper use, faulty installation, neglect, accident, misuse, or modification. Ancillary costs (shipping, labour, etc.) and indirect damage are not covered.
If the product is defective, it will be replaced or refunded within a reasonable time. Guarantee queries should be addressed to the store where the product was purchased.
For customers in France, in addition to this commercial guarantee, the seller is bound by the legal guarantee of conformity (Articles L217-4 to L217-14 of the Consumer Code) and the guarantee against hidden defects (Articles 1641 to 1648 and 2232 of the Civil Code).
IMPORTANT - RETAIN THIS INFORMATION FOR FUTURE REFERENCE: READ CAREFULLY
Kingfisher International Products Limited,
3 Sheldon Square, London, W2 6PX
United Kingdom
Kingfisher International Products B.V.
Rapenburgerstraat 175E
1011 VM Amsterdam
The Netherlands
www.kingfisher.com/products
www.diy.com
EN www.screwfix.com
www.screwfix.ie
To view instruction manuals online, visit www.kingfisher.com/products
FR Pour consulter les manuels d'instructions en ligne, rendez-vous sur le site www.kingfisher.com/products
![]() |
Steel Panel Radiator Installation, Operation, and Maintenance Manual This manual provides comprehensive instructions for the safe installation, operation, and maintenance of steel panel radiators. It includes product descriptions, technical specifications, safety guidelines, assembly steps, and warranty information. |
![]() |
Kingfisher Steel Panel Radiator Installation and User Manual Comprehensive guide for installing, using, and maintaining Kingfisher steel panel radiators. Includes safety instructions, technical specifications, parts list, assembly steps, and warranty information. |
![]() |
Steel Panel Radiator Installation and Maintenance Manual Comprehensive guide for installing, operating, and maintaining steel panel radiators, including safety instructions, technical specifications, and warranty information. Covers product features, assembly steps, and care instructions. |
![]() |
Flomasta Type 21 Double-Panel Plus Single Convector Radiator - Installation and Care Manual Comprehensive instructions for installing, using, and maintaining your Flomasta Type 21 Double-Panel Plus Single Convector Radiator. Includes safety guidelines, parts list, dimensions, assembly steps, and warranty information. |
![]() |
Kingfisher Product Compliance and Manufacturer Information Details on European and UK regulatory compliance for Kingfisher products, including manufacturer addresses and associated retail websites. |
![]() |
Kingfisher D002A-10L Dehumidifier: User Manual & Operation Guide Discover the Kingfisher D002A-10L dehumidifier. This comprehensive manual offers essential operating instructions, safety guidelines, maintenance advice, and troubleshooting tips for effective moisture control in your home. Learn about its 10L/day capacity, R290 refrigerant, and user-friendly features. |
![]() |
Kingfisher LL1T Loft Ladder Installation and Assembly Guide Comprehensive installation and assembly instructions for the Kingfisher LL1T loft ladder, including safety guidelines, part lists, and usage information. Download the manual for proper setup and maintenance. |
![]() |
Kingfisher Grass Trimmer NMGT250 250W 23cm User Manual Comprehensive user manual for the Kingfisher Grass Trimmer NMGT250, detailing safety instructions, product features, operation, maintenance, troubleshooting, and technical specifications. |