Kingfisher Decorative TRV and Lockshield Installation and Operating Manual

[Kingfisher Logo]

[Impala Services Logo]

Artwork done by Impala Services Ltd. info@impala-tech.com

DO NOT PRINT THIS PAGE - IT IS FOR INFORMATION ONLY

Job Information

KNG #: KNG-2563-0001

Agency Job #: PRJ28080

Product Description: Decorative TRV and Lockshield

Vendor: Avonflow

Brand Contact: Edward Colman / Alice Chen

Barcodes: 5036581050795 / 5036581050801 / 5036581050825 / 5036581050849 / 5036581050887 / 5036581050894 / 5036581050900 / 5059340290485 / 5059340290492 / 5059340076249 / 5059340076256 / 5052931837250 / 5059340122410 / 5063022114877 / 5059340122434 / 5059340290614 / 5059340290621 / 5059340497358

Version #: 1 (16/05/23 Marceli), 2 (XX/XX/XX XXX), 3 (XX/XX/XX XXX), 4 (XX/XX/XX XXX), 5 (XX/XX/XX XXX)

This file is the property of Kingfisher Group Plc. No copying, alteration or amendment is permitted without written authorisation from the Kingfisher Brand Team.

Product Overview

IMPORTANT: These instructions are for your safety. Please read through them thoroughly prior to installation and retain them for future reference. ?

Before you start

  • Fully read and understand these instructions before beginning the installation.
  • Please dispose of packaging carefully and keep the product and packaging away from the reach of children. ?️
  • Keep this installation manual in a safe place for any future reference.

Introduction

This manual is for the following range of TRVs and TRV kits:

  • Thermostatic radiator valve & lockshield, Angled 15 mm - 1/2" bidirectional [all colours]
    EANs: 5036581050795, 5036581050825, 5036581050887, 5059340290485, 5059340076249, 5052931837250, 5063022114877, 5059340290614, 5059340497358
  • Thermostatic radiator valve & lockshield, Straight 15 mm - 1/2" bidirectional [all colours]
    EANs: 5036581050801, 5036581050849, 5036581050900, 5059340290492, 5059340076256, 5059340122410, 5059340122434, 5059340290621
  • White/chrome thermostatic radiator valve head *
    EAN: 5036581050894

Temperature Regulating Valves (TRV's) when fitted to your radiators will allow independent room by room temperature control. This will help you to reduce energy consumption, resulting in lower energy bills.

Product Technical Data and Approvals

Technical Data

Settings/Temperature range:6 – 28°C
Hysteresis:0.5 K
Differential pressure effect:0.3 K
Water temperature effect:1 K
Max. operating pressure:10 bar
Max. water temperature:120°C
Max. operating differential pressure:1.0 bar
Control:Liquid sensor
Response time:20 min
TELL Scheme Energy Efficiency Rating:≤ 0.50 / Class I

TRV's have been fully tested and certified to the latest EN215 European Standard. Products also hold the European quality mark KEYMARK.

*For TRV head only skip to Installation step 10.

Safety Precautions

  • Avoid contact with any central heating water in case of chemical irritation.
  • It is advised to wear gloves and eye protection when working on the central heating system. ? ?
  • If a blowtorch is used for any adjacent works, do not allow it to heat up the TRV body as it could result in damage and invalidate your guarantee.

Installation Guide

Site the TRV where there is good air circulation and it is not exposed to direct sunlight or behind curtains or doors. If known, install valve on the supply pipe. Our valves are Bi-directional so can be placed on the supply or return lines. Ensure central heating system is free of debris before fitting the valve.

Before starting works, turn off the related central heating system/boiler, allowed to cool and then drain down the central heating system. Ensure the area is clean and you have a method of catching and mopping up any remaining system water. ?

An automatic differential by-pass valve must be fitted to the system when TRVs are being installed.

  1. Step 1: Screw the manual closing cap to the top of the valve and close the valve fully. Do not overtighten.
  2. Step 2: Remove the radiator tail piece from the valve ensuring the nut and olive remain in place.
  3. Step 3: Wrap approximately 8-10 turns of PTFE tape tightly around the male thread of the tail piece. The PTFE must be applied in the same direction as if you were connecting a nut to the thread so that it doesn't unravel when fitting to the radiator. ?
  4. Step 4: Screw the tail piece into the radiator panel and secure using a spanner. ?
  5. Step 5: Slide the nut and olive onto the tail piece and connect the valve body in the desired position. Only hand tighten the nut at this stage, as it will need to be removed on step 7.
  6. Step 6: Measure, mark and cut the pipework. Remember that the pipe will need to be inserted into the compression end of the radiator valve up to the pipe stop, so always ensure that enough pipe is remaining before cutting.
  7. Step 7: Remove valve body from the tail piece, then slide the pipe side nut and olive onto the supply pipework. Fully tighten using a spanner. Do not overtighten.
  8. Step 8: Reconnect the valve body to the tail piece and tighten the nut with a spanner. Do not overtighten.
  9. Step 9: Refill the system, bleed radiator and check for leaks. Further minimal tightening will stop any that appear.
  10. Step 10: Turn control head to fully open (position 5), remove manual closing cap from the valve and attach control head by tightening the knurled securing ring by hand. Do not overtighten or use grips.

Note: If your kit includes a lockshield valve, follow installation steps 2 - 9 to aid in the installation.

Operating Instructions

Setting the temperature

Calibration marks on the control head correspond to the temperatures in Table 1. To set the temperature, select the desired room temperature from the table and turn the control head to align the appropriate number with the fixed pointer. Allow at least an hour for the room temperature to stabilise.

12345 MAX
Frost protection at 7°C12°C16°C20°C24°C28°C

Table 1

Frost protection

Where heating is not required but there is a risk of freezing, turn the control head to the frost protection setting (*) which will allow the valve to open if the temperature falls below 7°C. Ensure the boiler is operational.

Summer operation

In the summer months, when the heating system is turned off for a considerable period, set the control head to the fully open position.

Contact Information

Manufacturer

UK Manufacturer: Kingfisher International Products Limited

1 Paddington Square, London, W2 1GG, United Kingdom

Websites

www.diy.com

www.screwfix.com

www.screwfix.ie

To view instruction manuals online, visit www.kingfisher.com/products

PDF preview unavailable. Download the PDF instead.

pa 3372430 pdftk 2.02 - www tk.com itext-paulo-155 (itextpdf.sf.net-lowagie.com)

Related Documents

Preview Steel Panel Radiator Installation and Maintenance Manual
Comprehensive guide for installing, operating, and maintaining steel panel radiators, including safety instructions, technical specifications, and warranty information. Covers product features, assembly steps, and care instructions.
Preview Steel Panel Radiator Installation, Operation, and Maintenance Manual
This manual provides comprehensive instructions for the safe installation, operation, and maintenance of steel panel radiators. It includes product descriptions, technical specifications, safety guidelines, assembly steps, and warranty information.
Preview Kingfisher Steel Panel Radiator Installation and User Manual
Comprehensive guide for installing, using, and maintaining Kingfisher steel panel radiators. Includes safety instructions, technical specifications, parts list, assembly steps, and warranty information.
Preview Flomasta Type 21 Double-Panel Plus Single Convector Radiator - Installation and Care Manual
Comprehensive instructions for installing, using, and maintaining your Flomasta Type 21 Double-Panel Plus Single Convector Radiator. Includes safety guidelines, parts list, dimensions, assembly steps, and warranty information.
Preview Kingfisher D002A-10L Dehumidifier: User Manual & Operation Guide
Discover the Kingfisher D002A-10L dehumidifier. This comprehensive manual offers essential operating instructions, safety guidelines, maintenance advice, and troubleshooting tips for effective moisture control in your home. Learn about its 10L/day capacity, R290 refrigerant, and user-friendly features.
Preview Kingfisher Product Compliance and Manufacturer Information
Details on European and UK regulatory compliance for Kingfisher products, including manufacturer addresses and associated retail websites.
Preview Kingfisher Responsible Business Report 2019/20: Our Home, Our World
Kingfisher plc's 2019/20 Responsible Business Report detailing commitments and progress in areas like sustainability, community impact, employee wellbeing, and environmental stewardship.
Preview Kingfisher Responsible Business Report 2019/20: Our Home, Our World
Kingfisher plc's 2019/20 Responsible Business Report details the company's commitment to sustainability, community impact, and environmental stewardship, covering key initiatives and progress across its European operations.