SECOP KLE.6GFTX Compressor

Model Designation: KLE.6GFTX

Sales Code: 106G5704

Compressor Design Specifications

Compressor Design
AttributeValue
Oil typePolyolester
Oil viscosity19,2 cSt
Oil quantity240 cm³ / 8,1 fl.oz
Refrigerant charge - tech. limit250 g / 8,8 oz
Free gas volume comp.1510 cm³ / 51,1 fl.oz
Weight9,5 kg / 20,9 lbs
Motor protectionexternal
Winding resistance main8,4 Ω (at 25°C)
Winding resistance aux11,9 Ω (at 25°C)
Max. winding temp.125°C / 257°F
Max. discharge temp.130°C / 266°F
Additional noteGood robustness against liquid intake. Ice-cube maker optimization - indirect suction intake.

A visual representation shows a SECOP KL-Series hermetic compressor.

Refrigerant(s): R134a, R513A

Displacement: 6,6 cm³ / 0,4 cu.in

Compressors on pallet: 100

Configurations

General - Configurations with KLE.6GFTX

General Configurations
AttributeConf. 1 (220-240V/50Hz)Conf. 2 (208-230V/60Hz)
Motor configurationCSIRCSIR
Power supply (nominal)220-240V/50Hz208-230V/60Hz
Number of phases1~1~
Voltage range187-254V198-253V
ApprovalsVDE, CB, ULVDE, CB, UL
Starting torqueHSTHST
Note

Applications with KLE.6GFTX

Applications
AttributeConf. 1Conf. 2
RefrigerantR134aR134a
ApplicationLBP+MBP+HBPLBP+MBP
System coolingfan 3m/sfan 3m/s
Hot gas defrost✔️✔️
Long interval pull down✔️✔️

Electrical data - Configurations with KLE.6GFTX

Electrical Data
AttributeConf. 1 (220-240V/50Hz)Conf. 2 (208-230V/60Hz)
Starting device typerelayrelay
Run capacitor
Start capacitor80 µF80 µF
LRA (locked rotor amps / 4s/ U(N))13,4A13,2A
RLA (rated load amps / 1s/ U(N))1,8A2A
Cut in current (U(N))12,3A12,3A

Dimensions and Physical Characteristics

Compressor Dimensions

Compressor Dimensions
DimensionValue (mm)Value (in)
A Height1827,17
B Height1756,89
C Length shell1987,8
D Length w. cover2389,37
E Width1606,3

A diagram illustrates the compressor's external dimensions, labeled A through E, and indicates connector positions (X, Y, Z) along with vertical and horizontal angles.

Connectors

Connector Specifications
AttributeSuction (X)Discharge (Y)Process (Z)
Diameter [mm] (i:inside, o:outside)Øi 8,11-8,29Øi 6,41-6,59Øi 6,41-6,59
Diameter [in] (i:inside, o:outside)Øi 0,32-0,33Øi 0,25-0,26Øi 0,25-0,26
Materialcoppercoppercopper
Horizontal angle+2°35°13°
Vertical angle+2°30°40°145°
Position l/h/w [mm]119/73/59117/107/66-88/101/71
Position l/h/w [in]4,7/2,9/2,34,6/4,2/2,6-3,5/4/2,8
Straight tube l. [mm]141414
Straight tube l. [in]0,50,50,5

Compressor Fixation and Mounting

The compressor can be fixed using bolt joints or snap-on mechanisms.

Baseplate Dimensions
Part[mm][inch]
BI2048.03
Bw1325.2
ØE9.70.38
Ll (Large holes)1656.5
Lw (Large holes)101.64
ØL (Large holes)Ø 19Ø 0.75
Sl (Small holes)1706.7
Sw (Small holes)702.76
ØS (Small holes)Ø 16Ø 0.63

A diagram shows the compressor baseplate with dimensions and hole locations for mounting. Another diagram illustrates the "Bolt joint" method, showing a compressor base, bolt, washer, nut, sleeve, cabinet base, and rubber grommet. A third diagram depicts the "Snap-on" method with a clip, steel pin, compressor base, cabinet base, and rubber grommet.

Mounting Accessories

Mounting Accessories Part Numbers
Accessory TypePart Number (One Comp.)Part Number (Multi Pack)
Bolt joint | M6 | Ø16mm118-1917118-1918
Bolt joint | Ø1/4" | Ø16mm118-1946
Bolt joint | Ø1/4" | Ø19mm118-1949
Snap-on | Ø7,3 | Ø16mm118-1947118-1919

Application Notes

Operating Conditions and Performance

Ambient and Machine Room Temperatures

Ambient temperature range: 10 - 43°C / 50 - 110°F

Machine room temperature range: 10 - 48°C / 50 - 119°F

Compressor cooling: fan 3m/s

Operation Pressure Range

Graphs illustrate the compressor's operation pressure range. One graph shows Condensing Pressure (sat. temp.) in [bara] versus Evaporation Pressure (sat. temp.) in [°C] and [°F], with lines indicating "continuous operation" and "transitory operation". The second graph shows Condensing Pressure in [bara] versus Evaporation Pressure in [bar], also with "continuous operation" and "transitory operation" lines.

Optimization + Standard Conditions (Conf. 1: 220-240V/50Hz)

Optimization + Standard Conditions (Conf. 1)
ConditionsEvaporating pressure (saturation temperature)Condensing pressure (saturation temperature)Return gas temp.Liquid temp.Cooling capacityCOPEERPower consumptionCurrent consumptionRef. mass flow [kg/h]
pe [°C]pe [°F]pc [°C]pc [°F]RGT [°C]Tliq [°C][W][Btu/h][kcal/h][W/W][Btu/Wh][Btu/Wh][kcal/Wh]P1 [W]I [A]
ASHRAE LBP-23-10541303232188,9645162,61,294,401,11146,51,293,67
ASHRAE MBP-720541303546401,31371345,41,856,321,59216,81,528,76
ASHRAE HBP7,245541303546716,72447616,82,588,832,22277,31,7615,90
EN12900 LBP-35-3140104204099,433985,50,953,230,81105,01,202,18
EN12900 MBP-1014451132045347,21186298,81,876,401,61185,21,418,13
EN12900 HBP541501222050611,92090526,62,408,202,07254,91,6715,42

Performance Tables (Conf. 1: 220-240V/50Hz)

Performance Table 1 (Conf. 1)
peCooling capacity [W]Cooling capacityCOPEERPower consumptionCurrent consumptionRef. mass flow [kg/h]
[°C][°F][Btu/h][kcal/h][W/W][Btu/Wh][kcal/Wh][W][A]
cond. pressure pc= 45/113-35-3193,832080,70,883,020,76106,01,202,02
-25-13163,5558140,71,224,151,05134,61,253,54
return gas temp. RGT= 32/90-155281,3961242,11,685,731,44167,51,356,13
-1014360,21230310,01,946,641,67185,21,417,88
liquid temp Tliq= 45/113032562,01919483,62,538,652,18221,81,5412,43
541686,52344590,82,869,762,46240,31,6115,28
1559986,73370849,23,5612,173,07276,91,7622,35
Performance Table 2 (Conf. 1)
peCooling capacity [W]Cooling capacityCOPEERPower consumptionCurrent consumptionRef. mass flow [kg/h]
[°C][°F][Btu/h][kcal/h][W/W][Btu/Wh][kcal/Wh][W][A]
cond. pressure pc= 55/131-35-3175,925965,30,742,540,64102,01,181,81
-25-13138,6473119,30,993,380,85139,91,273,31
return gas temp. RGT= 32/90-155241,4824207,81,334,541,14181,51,405,81
-1014309,91058266,71,535,211,31203,21,477,49
liquid temp Tliq= 55/131032485,01656417,41,966,701,69247,21,6411,86
541593,22026510,52,207,521,90269,31,7314,62
1559855,02920735,82,749,352,36312,31,9221,48

Configurations and Performance (Conf. 2: 208-230V/60Hz)

Electrical Accessories / Wiring Diagram

A diagram shows electrical accessories including a current relay (a5), a start capacitor (c), and a cover with clamp and screws (b, d). An alternative component path is also indicated.

Optimization + Standard Conditions (Conf. 2)

Optimization + Standard Conditions (Conf. 2)
ConditionsEvaporating pressure (saturation temperature)Condensing pressure (saturation temperature)Return gas temp.Liquid temp.Cooling capacityCOPEERPower consumptionCurrent consumptionRef. mass flow [kg/h]
pe [°C]pe [°F]pc [°C]pc [°F]RGT [°C]Tliq [°C][W][Btu/h][kcal/h][W/W][Btu/Wh][Btu/Wh][kcal/Wh]P1 [W]I [A]
ASHRAE LBP-23-10541303232228,9782197,01,374,681,18166,91,254,45
ASHRAE MBP-720541303546474,61621408,51,916,531,64248,31,5010,35
ASHRAE HBP7,245541303546839,22866722,32,638,972,26319,51,7518,62
EN12900 LBP-35-31401042040118,4404101,91,093,720,94108,71,112,60
EN12900 MBP-1014451132045407,91393351,01,886,431,62216,51,399,55
EN12900 HBP541501222050715,22443615,52,408,212,07297,61,6718,02

Performance Tables (Conf. 2: 208-230V/60Hz)

Performance Table 1 (Conf. 2)
peCooling capacity [W]Cooling capacityCOPEERPower consumptionCurrent consumptionRef. mass flow [kg/h]
[°C][°F][Btu/h][kcal/h][W/W][Btu/Wh][kcal/Wh][W][A]
cond. pressure pc= 45/113-35-31111,438095,91,043,540,89107,61,112,40
-25-13196,8672169,41,294,391,11153,11,214,26
return gas temp. RGT= 32/90-155332,81137286,41,705,811,47195,51,327,25
-1014423,21445364,21,956,671,68216,51,399,26
liquid temp Tliq= 45/113032655,62239564,22,528,602,17260,51,5414,50
541800,42733688,82,829,622,42284,11,6217,82
15591154,03941993,23,4311,702,95336,91,8126,14
Performance Table 2 (Conf. 2)
peCooling capacity [W]Cooling capacityCOPEERPower consumptionCurrent consumptionRef. mass flow [kg/h]
[°C][°F][Btu/h][kcal/h][W/W][Btu/Wh][kcal/Wh][W][A]
cond. pressure pc= 55/131-35-3186,129474,10,822,800,71105,01,102,05
-25-13167,9573144,51,063,610,91158,91,224,02
return gas temp. RGT= 32/90-155289,4988249,01,394,741,19208,61,376,97
-1014368,41258317,11,585,401,36233,01,448,91
liquid temp Tliq= 55/131032570,01947490,62,026,891,74282,61,6213,94
541695,32375598,42,257,691,94308,71,7117,13
15591001,83421862,12,749,362,36365,71,9325,16

PDF preview unavailable. Download the PDF instead.

kle66gftx 106g5704 r134a 220v 208v 50hz 60hz 08-2025 ds Microsoft Excel für Microsoft 365

Related Documents

Preview SECOP KLE.6.6GFTX Compressor Technical Data Sheet - R134a, 220V/50Hz & 208V/60Hz
Detailed technical specifications, performance data, dimensions, and electrical information for the SECOP KLE.6.6GFTX compressor, compatible with R134a refrigerant and operating at 220V/50Hz and 208V/60Hz.
Preview SECOP KLE.5.6GFTX Compressor Technical Data Sheet
Technical data sheet for the SECOP KLE.5.6GFTX compressor, detailing specifications, configurations, performance tables, and electrical data for R134a refrigerant.
Preview Secop KLE-GFTX Compressors: Robust and Efficient Solutions for Light Commercial Refrigeration
Discover the Secop KLE-GFTX series of compressors, offering premium robustness, excellent efficiency, and reduced noise and vibration for high-efficiency cabinets in food retail and food service applications. Learn about their technical specifications, performance data, and applications.
Preview SECOP KLE6.6GFTX Compressor Technical Data Sheet
Detailed technical specifications, dimensions, electrical data, and performance tables for the SECOP KLE6.6GFTX compressor, compatible with R134a and R513A refrigerants. Includes configuration options and operating parameters.
Preview SECOP KLE5.6GFTX Compressor Technical Data Sheet
Detailed technical specifications, configurations, electrical data, dimensions, and performance tables for the SECOP KLE5.6GFTX compressor, covering operating ranges and electrical accessories for 220-240V/50Hz and 208-230V/60Hz configurations.
Preview SECOP KLE8.6GFTX Compressor Technical Data Sheet
Comprehensive technical specifications, performance data, dimensions, and configuration details for the SECOP KLE8.6GFTX compressor, including R134a and R513A refrigerant compatibility.
Preview SECOP KLE8.6GFTX Compressor Technical Data Sheet
Detailed technical specifications, configurations, performance data, and dimensions for the SECOP KLE8.6GFTX compressor, supporting R134a and R513A refrigerants for various voltage and frequency combinations.
Preview SECOP KLE4.8GFTX Compressor Technical Data Sheet
Detailed technical specifications and performance data for the SECOP KLE4.8GFTX compressor, including electrical characteristics, dimensions, operating ranges, and optimization conditions for R134a and R513A refrigerants.