SECOP Compressor Technical Data
Model: KLE4.8GFTX
Designation: 220-240V/50Hz 1~ | 208-230V/60Hz 1~
Sales Code: 106G5513
Compressor Design Specifications
Specification | Details |
---|---|
Oil type | Polyolester |
Oil viscosity | 19,2 cSt |
Oil quantity | 240 cm³ / 8.1 fl.oz |
Refrigerant charge - tech. limit | 250g / 8.8oz |
Free gas volume comp. | 1545 cm³ / 52.2 fl.oz |
Weight | 9.3 kg / 20.5 lbs |
Motor protection | external |
Winding resistance main | 13.1 Ω (at 25°C) |
Winding resistance aux | 25.3 Ω (at 25°C) |
Max. winding temp. | 125°C / 257°F |
Max. discharge temp. | 130°C / 266°F |
Additional note | Good robustness against liquid intake. Ice-cube maker optimization - indirect suction intake. |
Refrigerant(s) | R134a, R513A |
Displacement | 4.8 cm³ / 0.29 cu.in |
Compressors on pallet | 100 |
General Configurations
Configurations for KLE4.8GFTX model:
Configuration | Conf. 1 (220-240V/50Hz) | Conf. 2 (208-230V/60Hz) |
---|---|---|
Motor configuration | CSIR | CSIR |
Power supply (nominal) | 220-240V/50Hz | 208-230V/60Hz |
Number of phases | 1 | 1 |
Voltage range | 187-254V | 198-253V |
Approvals | VDE, CB, CCC, UL | VDE, CB, CCC, UL |
Starting torque | HST | HST |
Note | Electrical equipment is included and pre-assembled to compressor. |
Applications
Applications for KLE4.8GFTX model:
Configuration | Conf. 1 | Conf. 2 |
---|---|---|
Refrigerant | R134a | R134a |
Application | LBP+MBP+HBP | LBP+MBP |
System cooling | fan 3m/s | fan 3m/s |
Hot gas defrost | OK ✔️ | OK ✔️ |
Long interval pull down | OK ✔️ | OK ✔️ |
Electrical Data
Configurations for KLE4.8GFTX model:
Specification | Conf. 1 | Conf. 2 |
---|---|---|
Starting device type | relay | relay |
Run capacitor | -/- | -/- |
Start capacitor | 80μF | 80μF |
LRA (locked rotor amps / 4s/ U(N)) | 10.5A | - |
RLA (rated load amps / 1s/ U(N)) | 1A | - |
Cut in current (U(N)) | 10.2A | - |
Dimensions and Connectors
Compressor Dimensions
Dimension | Value (mm) | Value (in) |
---|---|---|
A Height | 182 | 7.17 |
B Height | 175 | 6.89 |
C Length shell | 198 | 7.8 |
D Length w. cover | 238 | 9.37 |
E Width | 160 | 6.3 |
Connectors
Specification | Configuration | ||
---|---|---|---|
Suction (X) | Discharge (Y) | Process (Z) | |
Diameter (mm) (inner, o:outside) | øi 8.11-8.29 | øi 6.11-6.29 | øi 6.11-6.29 |
Diameter (in) (inner, o:outside) | øi 0.32-0.33 | øi 0.24-0.25 | øi 0.24-0.25 |
Material | copper | copper | copper |
Horizontal angle | +2° | 35° | 0° |
Vertical angle | +2° | 30° | 145° |
Position l/h/w (mm) | 119/73/59 | 117/107/66 | -88/101/71 |
Position l/h/w (in) | 4.7/2.9/2.3 | 4.6/4.2/2.6 | -3.5/4/2.8 |
Straight tube l. (mm) | 14 | 14 | 14 |
Straight tube l. (in) | 0.5 | 0.5 | 0.5 |
Compressor Fixation
Component | Dimensions (mm) | Dimensions (in) | ||
---|---|---|---|---|
Baseplate | Large holes | Baseplate | Large holes | |
Bl | 204 | 165 | 8.03 | 6.5 |
Bw | 132 | 101.6 | 5.2 | 4 |
ØE | 9.7 | Ø 19 | 0.38 | Ø 0.75 |
Component | Dimensions (mm) | Dimensions (in) | ||
---|---|---|---|---|
Small holes | Small holes | |||
Sl | 170 | - | 6.7 | - |
Sw | 70 | - | 2.76 | - |
ØS | Ø 16 | - | Ø 0.63 | - |
Mounting accessories:
- Bolt joint | M6 | Ø16mm (Part No: 118-1917 / 118-1918 for multi-pack)
- Bolt joint | Ø1/4" | Ø16mm (Part No: 118-1946)
- Bolt joint | Ø1/4" | Ø19mm (Part No: 118-1949)
- Snap-on | Ø7.3 | Ø16mm (Part No: 118-1947 / 118-1919 for multi-pack)
Application notes: Provision for PE Grounding is located at the PE Stamp on the compressor. Suction gas connector and Process connector can be switched (minor loss of cooling capacity).
Operation Pressure Ranges
Ambient/ Machine Room Temperatures:
- Ambient temperature range: 10 - 43°C / 50 - 110°F
- Machine room temperature range: 10 - 48°C / 50 - 119°F
- Compressor cooling: fan 3m/s
Conf. 1 (220-240V/50Hz) Operation Pressure Range
Conf. 2 (208-230V/60Hz) Operation Pressure Range
Electrical Accessories / Wiring Diagram Description
Visual Description: Diagrams showing electrical accessories and a wiring schematic. Key components identified include a current relay (a5), a start capacitor (c), and covers/clamps/screws (b, d). Part numbers are provided for these components and alternative configurations.
Performance Data
Optimization + Standard Conditions
Conf. 1 (220-240V/50Hz)
Conditions | Cooling Capacity | COP | EER | Power Consumption (P1) | Current Consumption (I) | Ref. mass flow [kg/h] | Application Standard | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
[W] / [Btu/h] / [kcal/h] | [W/W] | [Btu/Wh] / [kcal/Wh] | [W] | [A] | [kg/h] | [W] | [A] | ||||||||||
pe [°C] | pc [°C] | RGT [°C] | Tliq [°C] | [Btu/Wh] | [kcal/Wh] | ||||||||||||
-23 / -10 | 54 / 130 | 32 / 90 | 32 / 90 | 129.7 / 443 | 111.6 | 1.26 | 4.31 | 1.09 | 102.8 | 1.18 | 2.52 | ASHRAE LBP | |||||
-7 / 20 | 54 / 130 | 35 / 95 | 46 / 115 | 279.9 / 956 | 240.9 | 1.88 | 6.42 | 1.62 | 148.9 | 1.29 | 6.11 | ASHRAE MBP | |||||
7.2 / 45 | 54 / 130 | 35 / 95 | 46 / 115 | 502.3 / 1715 | 432.3 | 2.71 | 9.26 | 2.33 | 185.2 | 1.41 | 11.14 | ASHRAE HBP | |||||
-35 / -31 | 40 / 104 | 20 / 68 | 40 / 104 | 64.4 / 220 | 55.4 | 0.88 | 3.01 | 0.76 | 73.0 | 1.12 | 1.41 | EN12900 LBP | |||||
-10 / 14 | 45 / 113 | 20 / 68 | 45 / 113 | 241.7 / 825 | 208.0 | 1.87 | 6.38 | 1.61 | 129.3 | 1.24 | 5.66 | EN12900 MBP | |||||
5 / 41 | 50 / 122 | 20 / 68 | 50 / 122 | 428.2 / 1462 | 368.5 | 2.49 | 8.51 | 2.15 | 171.8 | 1.36 | 10.79 | EN12900 HBP |
Conf. 2 (208-230V/60Hz)
Conditions | Cooling Capacity | COP | EER | Power Consumption (P1) | Current Consumption (I) | Ref. mass flow [kg/h] | Application Standard | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
[W] / [Btu/h] / [kcal/h] | [W/W] | [Btu/Wh] / [kcal/Wh] | [W] | [A] | [kg/h] | [W] | [A] | ||||||||||
pe [°C] | pc [°C] | RGT [°C] | Tliq [°C] | [Btu/Wh] | [kcal/Wh] | ||||||||||||
-23 / -10 | 54 / 130 | 32 / 90 | 32 / 90 | 154.4 / 527 | 132.9 | 1.30 | 4.44 | 1.12 | 118.6 | 1.13 | 3.00 | ASHRAE LBP | |||||
-7 / 20 | 54 / 130 | 35 / 95 | 46 / 115 | 330.5 / 1129 | 284.4 | 1.92 | 6.55 | 1.65 | 172.2 | 1.26 | 7.21 | ASHRAE MBP | |||||
7.2 / 45 | 54 / 130 | 35 / 95 | 46 / 115 | 587.3 / 2006 | 505.4 | 2.71 | 9.25 | 2.33 | 216.9 | 1.39 | 13.03 | ASHRAE HBP | |||||
-35 / -31 | 40 / 104 | 20 / 68 | 40 / 104 | 81.6 / 279 | 70.2 | 0.94 | 3.22 | 0.81 | 86.7 | 1.08 | 1.79 | EN12900 LBP | |||||
-10 / 14 | 45 / 113 | 20 / 68 | 45 / 113 | 281.8 / 963 | 242.6 | 1.87 | 6.39 | 1.61 | 150.6 | 1.20 | 6.60 | EN12900 MBP | |||||
5 / 41 | 50 / 122 | 20 / 68 | 50 / 122 | 500.8 / 1710 | 431.0 | 2.45 | 8.37 | 2.11 | 204.3 | 1.35 | 12.62 | EN12900 HBP |
Performance Tables
Conf. 1 (220-240V/50Hz)
Conditions | Cooling capacity | COP [W/W] | EER | P1 [W] | I [A] | m [kg/h] | ||||
---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [Btu/Wh] | [kcal/Wh] | ||||||
[°C/°F] | ||||||||||
cond. pressure pc= 45/113 | -35 / -31 | 60.4 | 206 | 52.0 | 0.83 | 2.85 | 0.72 | 72.4 | 1.12 | 1.30 |
-25 / -13 | 111.8 | 382 | 96.2 | 1.17 | 4.00 | 1.01 | 95.5 | 1.17 | 2.42 | |
-15 / 5 | 195.3 | 667 | 168.1 | 1.65 | 5.65 | 1.42 | 118.1 | 1.22 | 4.26 | |
return gas temp. RGT= 32/90 | -10 / 14 | 250.7 | 856 | 215.8 | 1.94 | 6.62 | 1.67 | 129.3 | 1.24 | 5.49 |
0 / 32 | 392.4 | 1340 | 337.7 | 2.59 | 8.83 | 2.23 | 151.7 | 1.30 | 8.68 | |
liquid temp Tliq= 45/113 | 5 / 41 | 479.9 | 1639 | 413.0 | 2.95 | 10.06 | 2.53 | 163.0 | 1.33 | 10.69 |
15 / 59 | 691.7 | 2362 | 595.3 | 3.72 | 12.72 | 3.20 | 185.8 | 1.41 | 15.67 | |
[°C/°F] | ||||||||||
cond. pressure pc= 55/131 | -35 / -31 | 48.8 | 167 | 42.0 | 0.72 | 2.46 | 0.62 | 67.8 | 1.11 | 1.16 |
-25 / -13 | 94.7 | 324 | 81.5 | 0.97 | 3.30 | 0.83 | 97.9 | 1.17 | 2.27 | |
return gas temp RGT= 32/90 | -15 / 5 | 167.6 | 572 | 144.3 | 1.32 | 4.52 | 1.14 | 126.6 | 1.24 | 4.04 |
-10 / 14 | 215.8 | 737 | 185.7 | 1.54 | 5.25 | 1.32 | 140.4 | 1.27 | 5.22 | |
liquid temp Tliq= 55/131 | 0 / 32 | 339.1 | 1158 | 291.8 | 2.03 | 6.92 | 1.74 | 167.3 | 1.35 | 8.29 |
5 / 41 | 415.5 | 1419 | 357.6 | 2.30 | 7.87 | 1.98 | 180.4 | 1.39 | 10.24 | |
15 / 59 | 601.1 | 2053 | 517.3 | 2.92 | 9.96 | 2.51 | 206.1 | 1.49 | 15.10 |
Conf. 2 (208-230V/60Hz)
Conditions | Cooling capacity | COP [W/W] | EER | P1 [W] | I [A] | m [kg/h] | ||||
---|---|---|---|---|---|---|---|---|---|---|
[W] | [Btu/h] | [kcal/h] | [Btu/Wh] | [kcal/Wh] | ||||||
[°C/°F] | ||||||||||
cond. pressure pc= 45/113 | -35 / -31 | 76.1 | 260 | 65.5 | 0.89 | 3.05 | 0.77 | 85.3 | 1.07 | 1.64 |
-25 / -13 | 131.2 | 448 | 112.9 | 1.21 | 4.13 | 1.04 | 108.4 | 1.11 | 2.84 | |
-15 / 5 | 227.5 | 777 | 195.8 | 1.68 | 5.72 | 1.44 | 135.8 | 1.17 | 4.96 | |
return gas temp. RGT= 32/90 | -10 / 14 | 292.4 | 999 | 251.6 | 1.94 | 6.63 | 1.67 | 150.6 | 1.20 | 6.40 |
0 / 32 | 458.1 | 1565 | 394.3 | 2.53 | 8.64 | 2.18 | 181.0 | 1.28 | 10.13 | |
liquid temp Tliq= 45/113 | 5 / 41 | 560.0 | 1912 | 481.9 | 2.85 | 9.75 | 2.46 | 196.2 | 1.33 | 12.47 |
15 / 59 | 804.3 | 2747 | 692.2 | 3.57 | 12.20 | 3.07 | 225.2 | 1.42 | 18.22 | |
[°C/°F] | ||||||||||
cond. pressure pc= 55/131 | -35 / -31 | 61.0 | 208 | 52.5 | 0.71 | 2.43 | 0.61 | 85.9 | 1.08 | 1.45 |
-25 / -13 | 113.1 | 386 | 97.4 | 0.99 | 3.39 | 0.85 | 114.1 | 1.12 | 2.71 | |
return gas temp RGT= 32/90 | -15 / 5 | 198.8 | 679 | 171.1 | 1.37 | 4.66 | 1.18 | 145.5 | 1.19 | 4.78 |
-10 / 14 | 255.4 | 872 | 219.8 | 1.58 | 5.39 | 1.36 | 161.9 | 1.23 | 6.18 | |
liquid temp Tliq= 55/131 | 0 / 32 | 398.9 | 1362 | 343.3 | 2.05 | 7.00 | 1.76 | 194.7 | 1.32 | 9.76 |
5 / 41 | 486.8 | 1662 | 418.9 | 2.31 | 7.89 | 1.99 | 210.7 | 1.37 | 12.00 | |
15 / 59 | 697.4 | 2382 | 600.2 | 2.90 | 9.90 | 2.50 | 240.5 | 1.48 | 17.52 |