Compressor Design
Compressor Design Specifications
Attribute |
Value |
Oil type |
Polyolester |
Oil viscosity |
19,2cSt |
Oil quantity |
240cm³ / 8,1fl.oz |
Refrigerant charge - tech. limit |
250g / 8,8oz |
Free gas volume comp. |
1510cm³ / 51,1fl.oz |
Weight |
9,5kg / 20,9lbs |
Motor protection |
external |
Winding resistance main |
8,4Ω (at 25°C) |
Winding resistance aux |
11,9Ω (at 25°C) |
Max. winding temp. |
125°C / 257°F |
Max. discharge temp. |
130°C / 266°F |
Additional note |
Good robustness against liquid intake. Ice-cube maker optimization - indirect suction intake. |
Refrigerant(s): R134a, R513A
Displacement: 6,6cm³ / 0,4cu.in
Compressors on pallet: 100
A SECOP KL-Series compressor, a black, compact unit with visible motor housing and cooling fins.
Configurations
General - Configurations with KLE.6.6GFTX
General Configurations
Attribute |
Conf. 1 |
Conf. 2 |
Motor configuration |
CSIR |
CSIR |
Power supply (nominal) |
220-240V/50Hz |
208-230V/60Hz |
Number of phases |
1 |
1 |
Voltage range |
187-254V |
198-253V |
Approvals |
VDE, CB, UL |
VDE, CB, UL |
Starting torque |
HST |
HST |
Note |
Electrical equipment is included and pre-assembled to compressor. |
Applications with KLE.6.6GFTX
Applications
Attribute |
Conf. 1 |
Conf. 2 |
Refrigerant |
R134a |
R134a |
Application |
LBP+MBP+HBP |
LBP+MBP |
System cooling |
fan 3m/s |
fan 3m/s |
Hot gas defrost |
OK |
OK |
Long interval pull down |
OK |
OK |
Electrical data - Configurations with KLE.6.6GFTX
Electrical Data
Attribute |
Conf. 1 |
Conf. 2 |
Starting device type |
relay |
relay |
Run capacitor |
-/- |
-/- |
Start capacitor |
80μF |
80μF |
LRA (locked rotor amps / 4s/ U(N)) |
13,4A |
13,2A |
RLA (rated load amps / 1s/ U(N)) |
1,8A |
2A |
Cut in current (U(N)) |
12,3A |
12,3A |
Dimensions and Fixation
Compressor Dimensions
Compressor Dimensions
Dimension |
Value (mm / in) |
A Height |
182mm / 7,17in |
B Height |
175mm / 6,89in |
C Length shell |
198mm / 7,8in |
D Length w. cover |
238mm / 9,37in |
E Width |
160mm / 6,3in |
A diagram illustrating compressor dimensions labeled A through E, with corresponding measurements in millimeters and inches. It also shows a side view with suction (X), discharge (Y), and process (Z) ports, and angular indicators for horizontal and vertical orientation.
Connectors
Connector Specifications
Attribute |
Configuration |
Suction (X) |
Discharge (Y) |
Process (Z) |
Diameter [mm] (i:inside, o:outside) |
øi 8,11-8,29 |
øi 6,11-6,29 |
øi 6,11-6,29 |
Diameter [in] (i:inside, o:outside) |
øi 0,32-0,33 |
øi 0,24-0,25 |
øi 0,24-0,25 |
Material |
copper |
copper |
copper |
Horizontal angle |
+2° |
35° |
0° |
Vertical angle |
+2° |
30° |
145° |
Position l/h/w [mm] |
119/73/59 |
117/107/66 |
-88/101/71 |
Position l/h/w [in] |
4,7/2,9/2,3 |
4,6/4,2/2,6 |
-3,5/4/2,8 |
Straight tube l. [mm] |
14 |
14 |
14 |
Straight tube l. [in] |
0,5 |
0,5 |
0,5 |
Compressor Fixation
Diagrams illustrating compressor mounting methods. One shows a 'Bolt joint' with detailed baseplate dimensions (BI, Bw, E, Ll, Lw, Sl, Sw, ØS) and hole specifications. Another shows a 'Snap-on' mechanism with a clip and steel pin.
Baseplate Dimensions
Part |
Dimensions |
[mm] |
[inch] |
BI |
204 |
8.03 |
Bw |
132 |
5.2 |
ØE |
9.7 |
0.38 |
Large Holes
Part |
Dimensions |
[mm] |
[inch] |
Ll |
165 |
6.5 |
Lw |
101.6 |
4 |
ØL |
Ø 19 |
Ø 0.75 |
Small Holes
Part |
Dimensions |
[mm] |
[inch] |
Sl |
170 |
6.7 |
Sw |
70 |
2.76 |
ØS |
Ø 16 |
Ø 0.63 |
Mounting Accessories
Mounting Accessories
Accessory Type |
One Comp. |
Multi Pack |
Bolt joint | M6 | Ø16mm |
118-1917 |
118-1918 |
Bolt joint | Ø1/4" | Ø16mm |
118-1946 |
|
Bolt joint | Ø1/4" | Ø19mm |
118-1949 |
|
Snap-on | Ø7,3 | Ø16mm |
118-1947 |
118-1919 |
Application Notes
Provision for PE Grounding is located at the PE Stamp on the compressor. Suction gas connector and Process connector can be switched (minor loss of cooling capacity).
Operating Conditions and Pressure Ranges
Ambient/ Machine Room Temperatures Minimum/Maximum
Temperature Ranges
Ambient temperature range: |
10 - 43°C / 50 - 110°F |
Machine room temperature range: |
10 - 48°C / 50 - 119°F |
Compressor cooling: |
fan 3m/s |
Operation Pressure Range
Two graphs illustrating operating pressure ranges. The top graph plots condensing pressure against saturation temperature (°C/°F), showing continuous and transitory operation zones. The bottom graph plots condensing pressure against evaporation pressure (bar), also indicating continuous and transitory operation zones.
Conf. 1 (220-240V/50Hz):
Condensing Pressure vs. Saturation Temperature (°C/°F)
Pressure [bara] |
Temperature [°C] |
Temperature [°F] |
80 | -50 | -58 |
70 | -38 | -36 |
60 | -27 | -17 |
50 | -16 | 3 |
40 | -5 | 23 |
30 | 10 | 50 |
20 | 20 | 68 |
10 | 30 | 86 |
0 | 40 | 104 |
Condensing Pressure vs. Evaporation Pressure (bar)
Condensing Pressure [bara] |
Evaporation Pressure [bar] |
80 | 0 |
70 | 1.5 |
60 | 3 |
50 | 4.5 |
40 | 6 |
30 | 7.5 |
20 | 9 |
10 | 10.5 |
0 | 12 |
Conf. 2 (208-230V/60Hz):
Condensing Pressure vs. Saturation Temperature (°C/°F)
Pressure [bara] |
Temperature [°C] |
Temperature [°F] |
80 | -50 | -58 |
70 | -38 | -36 |
60 | -27 | -17 |
50 | -16 | 3 |
40 | -5 | 23 |
30 | 10 | 50 |
20 | 20 | 68 |
10 | 30 | 86 |
0 | 40 | 104 |
Condensing Pressure vs. Evaporation Pressure (bar)
Condensing Pressure [bara] |
Evaporation Pressure [bar] |
80 | 0 |
70 | 1.5 |
60 | 3 |
50 | 4.5 |
40 | 6 |
30 | 7.5 |
20 | 9 |
10 | 10.5 |
0 | 12 |