SECOP KLE8.6GFTX Compressor Technical Data
This document provides detailed technical specifications for the SECOP KLE8.6GFTX compressor.
General Specifications
Model Designation | Sales Code |
---|---|
KLE8.6GFTX | 106G5913 |
Compressor Design | Value |
---|---|
Oil type | Polyolester |
Oil viscosity | 19,2cSt |
Oil quantity | 240cm³ / 8,1fl.oz |
Refrigerant charge - tech. limit | 250g / 8,8oz |
Free gas volume comp. | 1495cm³ / 50,6fl.oz |
Weight | 9,7kg / 21,4lbs |
Motor protection | external |
Winding resistance main | 8,4Ω (at 25°C) |
Winding resistance aux | 11,9Ω (at 25°C) |
Max. winding temp. | 125°C / 257°F |
Max. discharge temp. | 130°C / 266°F |
Additional note | Good robustness against liquid intake. Ice-cube maker optimization - indirect suction intake. |
Refrigerant(s) | Displacement | Compressors on pallet |
---|---|---|
R134a, R513A | 8,6cm³ / 0,52cu.in | 100 |
Compressor Dimensions
Diagram showing compressor dimensions with labels A to E.
Dimension | Value (mm / in) |
---|---|
A Height | 182mm / 7,17in |
B Height | 175mm / 6,89in |
C Length shell | 198mm / 7,8in |
D Length w. cover | 238mm / 9,37in |
E Width | 160mm / 6,3in |
Connectors
Suction (X) | Discharge (Y) | Process (Z) | ||
---|---|---|---|---|
Diameter (i:inside, o:outside) [mm] | øi 8,11-8,29 | øi 6,11-6,29 | øi 6,11-6,29 | |
Diameter (i:inside, o:outside) [in] | øi 0,32-0,33 | øi 0,24-0,25 | øi 0,24-0,25 | |
Material | copper | copper | copper | |
Horizontal angle | ±2° | 35° | 13° | 0° |
Vertical angle | ±2° | 30° | 40° | 145° |
Position l/h/w [mm] | 119/73/59 | 117/107/66 | -88/101/71 | |
Position l/h/w [in] | 4,7/2,9/2,3 | 4,6/4,2/2,6 | -3,5/4/2,8 | |
Straight tube l. [mm] | 14 | 14 | 14 | |
Straight tube l. [in] | 0,5 | 0,5 | 0,5 |
Compressor Fixation
Diagram illustrating compressor fixation methods including bolt joints and snap-on options, with baseplate dimensions and hole sizes.
Fixation Type | Details |
---|---|
Bolt joint | M6 | Ø16mm |
Bolt joint | Ø1/4" | Ø16mm |
Bolt joint | Ø1/4" | Ø19mm |
Snap-on | Ø7,3 | Ø16mm |
Configurations with KLE8.6GFTX
General Configuration Data
Parameter | Conf. 1 | Conf. 2 | Conf. 3 | Conf. 4 |
---|---|---|---|---|
Motor configuration | CSIR | CSIR | CSIR | CSIR |
Power supply (nominal) | 220-240V/50Hz | 208-230V/60Hz | 220-240V/50Hz | 208-230V/60Hz |
Number of phases | 1 | 1 | 1 | 1 |
Voltage range | 187-254V | 198-253V | 187-254V | 198-253V |
Approvals | VDE, CB, UL | VDE, CB, UL | VDE, CB, UL | VDE, CB, UL |
Starting torque | HST | HST | HST | HST |
Note | Electrical equipment is included and pre-assembled to compressor. |
Applications
Parameter | Conf. 1 | Conf. 2 | Conf. 3 | Conf. 4 |
---|---|---|---|---|
Refrigerant | R134a | R134a | R513A | R513A |
Application | LBP+MBP+HBP | LBP+MBP | LBP+MBP+HBP | LBP+MBP |
System cooling | fan 3m/s | fan 3m/s | fan 3m/s | fan 3m/s |
Hot gas defrost | OK | OK | OK | OK |
Long interval pull down | OK | OK | OK | OK |
Electrical Data
Parameter | Conf. 1 | Conf. 2 | Conf. 3 | Conf. 4 |
---|---|---|---|---|
Starting device type | relay | relay | relay | relay |
Run capacitor | -/- | -/- | -/- | -/- |
Start capacitor | 80μF | 80μF | 80μF | 80μF |
LRA (locked rotor amps / 4s/ U(N)) | 13,4A | 13,2A | 13,4A | 13,2A |
RLA (rated load amps / 1s/ U(N)) | 1,8A | 2A | 1,8A | 2A |
Cut in current (U(N)) | 12,3A | 12,3A | 12,3A | 12,3A |
Performance Data
The following tables provide performance data for various operating conditions.
Configuration 1: R134a, 220V/50Hz, CSIR, fan 3m/s, VDE, CB, UL
Optimization + Standard Conditions
Evaporating Pressure (sat. temp.) | Condensing Pressure (sat. temp.) | Return Gas Temp. | Liquid Temp. | Cooling Capacity [W] | [Btu/h] | [kcal/h] | COP [W/W] | EER [Btu/Wh] | [kcal/Wh] | Power Consumption [W] | Current Consumption [A] | Ref. Mass Flow [kg/h] | Application | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
[°C] -23 | [°F] -10 | 54 | 32 | 32 | 248,1 | 847 | 213,5 | 1,33 | 4,53 | 1,14 | 186,9 | 1,41 | 4,82 | ASHRAE LBP |
[°C] -7 | [°F] 20 | 54 | 35 | 46 | 517,3 | 1767 | 445,2 | 1,78 | 6,08 | 1,53 | 290,4 | 1,82 | 11,29 | ASHRAE MBP |
[°C] 7,2 | [°F] 45 | 54 | 35 | 46 | 901,6 | 3079 | 775,9 | 2,31 | 7,90 | 1,99 | 389,6 | 2,27 | 20,00 | ASHRAE HBP |
[°C] -35 | [°F] -31 | 40 | 20 | 40 | 131,2 | 448 | 112,9 | 1,04 | 3,56 | 0,90 | 125,9 | 1,23 | 2,88 | EN12900 LBP |
[°C] -10 | [°F] 14 | 45 | 20 | 45 | 450,8 | 1540 | 388,0 | 1,81 | 6,17 | 1,56 | 249,4 | 1,65 | 10,55 | EN12900 MBP |
[°C] 5 | [°F] 41 | 50 | 20 | 50 | 773,5 | 2642 | 665,7 | 2,19 | 7,47 | 1,88 | 353,9 | 2,10 | 19,49 | EN12900 HBP |
Performance Tables
pe [°C] | [°F] | Cooling Capacity [W] | [Btu/h] | [kcal/h] | COP [W/W] | EER [Btu/Wh] | [kcal/Wh] | P1 [W] | I [A] | m [kg/h] | |
---|---|---|---|---|---|---|---|---|---|---|---|
[°C/°F] | |||||||||||
cond. pressure pc= 45/113 | -35 | -31 | 123,6 | 422 | 106,4 | 0,98 | 3,35 | 0,84 | 126,0 | 1,23 | 2,67 |
-25 | -13 | 216,6 | 740 | 186,4 | 1,25 | 4,28 | 1,08 | 172,9 | 1,37 | 4,69 | |
return gas temp. RGT= 32/90 | -15 | 5 | 368,2 | 1257 | 316,9 | 1,65 | 5,63 | 1,42 | 223,3 | 1,55 | 8,03 |
-10 | 14 | 467,7 | 1597 | 402,5 | 1,87 | 6,40 | 1,61 | 249,4 | 1,65 | 10,24 | |
0 | 32 | 717,8 | 2452 | 617,8 | 2,37 | 8,09 | 2,04 | 303,1 | 1,87 | 15,87 | |
liquid temp Tliq= 45/113 | 5 | 41 | 869,9 | 2971 | 748,6 | 2,63 | 8,99 | 2,27 | 330,4 | 1,99 | 19,37 |
10 | 50 | 1040,8 | 3555 | 895,8 | 2,91 | 9,94 | 2,50 | 357,6 | 2,12 | 23,36 | |
[°C/°F] | |||||||||||
cond. pressure pc= 55/131 | -35 | -31 | 96,4 | 329 | 83,0 | 0,76 | 2,58 | 0,65 | 127,6 | 1,24 | 2,30 |
-25 | -13 | 181,7 | 621 | 156,4 | 1,02 | 3,48 | 0,88 | 1 | 1,38 | 4,35 | |
return gas temp RGT= 32/90 | -15 | 5 | 315,1 | 1076 | 271,2 | 1,33 | 4,54 | 1,14 | 237,0 | 1,60 | 7,59 |
-10 | 14 | 401,6 | 1372 | 345,7 | 1,49 | 5,09 | 1,28 | 269,2 | 1,73 | 9,71 | |
liquid temp | 0 | 32 | 618,0 | 2110 | 531,8 | 1,83 | 6,23 | 1,57 | 338,6 | 2,03 | 15,12 |
Tliq= 55/131 | 5 | 41 | 749,2 | 2559 | 644,7 | 2,00 | 6,81 | 1,72 | 375,4 | 2,20 | 18,46 |
10 | 50 | 896,7 | 3062 | 771,7 | 2,17 | 7,41 | 1,87 | 413,6 | 2,38 | 22,29 |
Configuration 2: R134a, 208-230V/60Hz, CSIR, fan 3m/s, VDE, CB, UL
Optimization + Standard Conditions
Evaporating Pressure (sat. temp.) | Condensing Pressure (sat. temp.) | Return Gas Temp. | Liquid Temp. | Cooling Capacity [W] | [Btu/h] | [kcal/h] | COP [W/W] | EER [Btu/Wh] | [kcal/Wh] | Power Consumption [W] | Current Consumption [A] | Ref. Mass Flow [kg/h] | Application | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
[°C] -23 | [°F] -10 | 54 | 32 | 32 | 299,2 | 1022 | 257,5 | 1,35 | 4,60 | 1,16 | 222,1 | 1,41 | 5,81 | ASHRAE LBP |
[°C] -7 | [°F] 20 | 54 | 35 | 46 | 617,4 | 2109 | 531,4 | 1,78 | 6,07 | 1,53 | 347,4 | 1,86 | 13,47 | ASHRAE MBP |
[°C] 7,2 | [°F] 45 | 54 | 35 | 46 | 1076,9 | 3678 | 926,8 | 2,31 | 7,90 | 1,99 | 465,4 | 2,35 | 23,89 | ASHRAE HBP |
[°C] -35 | [°F] -31 | 40 | 20 | 40 | 156,3 | 534 | 134,6 | 1,12 | 3,84 | 0,97 | 139,1 | 1,17 | 3,43 | EN12900 LBP |
[°C] -10 | [°F] 14 | 45 | 20 | 45 | 537,4 | 1835 | 462,5 | 1,80 | 6,16 | 1,55 | 298,1 | 1,67 | 12,58 | EN12900 MBP |
[°C] 5 | [°F] 41 | 50 | 20 | 50 | 923,1 | 3153 | 794,5 | 2,19 | 7,46 | 1,88 | 422,4 | 2,17 | 23,26 | EN12900 HBP |
Performance Tables
pe [°C] | [°F] | Cooling Capacity [W] | [Btu/h] | [kcal/h] | COP [W/W] | EER [Btu/Wh] | [kcal/Wh] | P1 [W] | I [A] | m [kg/h] | |
---|---|---|---|---|---|---|---|---|---|---|---|
[°C/°F] | |||||||||||
cond. pressure pc= 45/113 | -35 | -31 | 147,7 | 504 | 127,1 | 1,06 | 3,61 | 0,91 | 139,8 | 1,17 | 3,19 |
-25 | -13 | 259,6 | 886 | 223,4 | 1,27 | 4,34 | 1,09 | 204,1 | 1,35 | 5,62 | |
return gas temp. RGT= 32/90 | -15 | 5 | 439,4 | 1501 | 378,2 | 1,65 | 5,62 | 1,42 | 266,8 | 1,56 | 9,58 |
-10 | 14 | 557,6 | 1904 | 479,8 | 1,87 | 6,39 | 1,61 | 298,1 | 1,67 | 12,20 | |
-5 | 23 | 695,9 | 2377 | 598,9 | 2,11 | 7,21 | 1,82 | 329,7 | 1,79 | 15,30 | |
liquid temp Tliq= 45/113 | 0 | 32 | 855,5 | 2922 | 736,2 | 2,37 | 8,08 | 2,04 | 361,6 | 1,92 | 18,92 |
7,2 | 45 | 1124,8 | 3841 | 968,0 | 2,75 | 9,40 | 2,37 | 408,7 | 2,11 | 25,12 | |
[°C/°F] | |||||||||||
cond. pressure pc= 55/131 | -35 | -31 | 117,8 | 402 | 101,4 | 0,83 | 2,84 | 0,72 | 141,6 | 1,18 | 2,80 |
-25 | -13 | 219,7 | 750 | 189,0 | 1,04 | 3,56 | 0,90 | 210,7 | 1,37 | 5,25 | |
return gas temp RGT= 32/90 | -15 | 5 | 377,4 | 1289 | 324,8 | 1,33 | 4,54 | 1,14 | 283,8 | 1,62 | 9,09 |
-10 | 14 | 479,9 | 1639 | 413,0 | 1,49 | 5,08 | 1,28 | 322,4 | 1,77 | 11,60 | |
liquid temp | -5 | 23 | 599,5 | 2047 | 515,9 | 1,65 | 5,65 | 1,42 | 362,5 | 1,92 | 14,57 |
Tliq= 55/131 | 0 | 32 | 737,3 | 2518 | 634,5 | 1,82 | 6,23 | 1,57 | 404,4 | 2,09 | 18,03 |
7,2 | 45 | 970,0 | 3313 | 834,8 | 2,07 | 7,07 | 1,78 | 468,3 | 2,36 | 23,99 |
Configuration 3: R513A, 220-240V/50Hz, CSIR, fan 3m/s, VDE, CB, UL
Optimization + Standard Conditions
Evaporating Pressure (sat. temp.) | Condensing Pressure (sat. temp.) | Return Gas Temp. | Liquid Temp. | Cooling Capacity [W] | [Btu/h] | [kcal/h] | COP [W/W] | EER [Btu/Wh] | [kcal/Wh] | Power Consumption [W] | Current Consumption [A] | Ref. Mass Flow [kg/h] | Application | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
[°C] -23 | [°F] -10 | 54 | 32 | 32 | 273,8 | 935 | 235,7 | 1,34 | 4,58 | 1,15 | 204,1 | 1,47 | 5,89 | ASHRAE LBP |
[°C] -7 | [°F] 20 | 54 | 35 | 46 | 541,9 | 1851 | 466,4 | 1,75 | 5,98 | 1,51 | 309,4 | 1,90 | 13,27 | ASHRAE MBP |
[°C] 7,2 | [°F] 45 | 54 | 35 | 46 | 924,8 | 3158 | 795,9 | 2,26 | 7,70 | 1,94 | 410,0 | 2,37 | 22,97 | ASHRAE HBP |
[°C] -35 | [°F] -31 | 40 | 20 | 40 | 145,9 | 498 | 125,5 | 1,05 | 3,58 | 0,90 | 139,3 | 1,26 | 3,61 | EN12900 LBP |
[°C] -10 | [°F] 14 | 45 | 20 | 45 | 470,4 | 1607 | 404,9 | 1,77 | 6,04 | 1,52 | 266,0 | 1,72 | 12,47 | EN12900 MBP |
[°C] 5 | [°F] 41 | 50 | 20 | 50 | 783,5 | 2676 | 674,2 | 2,10 | 7,18 | 1,81 | 372,6 | 2,19 | 22,46 | EN12900 HBP |
Performance Tables
pe [°C] | [°F] | Cooling Capacity [W] | [Btu/h] | [kcal/h] | COP [W/W] | EER [Btu/Wh] | [kcal/Wh] | P1 [W] | I [A] | m [kg/h] | |
---|---|---|---|---|---|---|---|---|---|---|---|
[°C/°F] | |||||||||||
cond. pressure pc= 45/113 | -35 | -31 | 138,4 | 473 | 119,1 | 0,99 | 3,37 | 0,85 | 140,2 | 1,26 | 3,36 |
-25 | -13 | 235,4 | 804 | 202,6 | 1,25 | 4,27 | 1,08 | 188,1 | 1,42 | 5,74 | |
return gas temp. RGT= 32/90 | -15 | 5 | 390,9 | 1335 | 336,4 | 1,63 | 5,57 | 1,40 | 239,4 | 1,61 | 9,58 |
-10 | 14 | 491,9 | 1680 | 423,4 | 1,85 | 6,32 | 1,59 | 266,0 | 1,72 | 12,09 | |
0 | 32 | 743,4 | 2539 | 639,8 | 2,32 | 7,93 | 2,00 | 320,1 | 1,95 | 18,44 | |
liquid temp Tliq= 45/113 | 5 | 41 | 894,8 | 3056 | 770,1 | 2,58 | 8,80 | 2,22 | 347,4 | 2,07 | 22,32 |
10 | 50 | 1064,2 | 3634 | 915,9 | 2,84 | 9,70 | 2,44 | 374,7 | 2,20 | 26,72 | |
[°C/°F] | |||||||||||
cond. pressure pc= 55/131 | -35 | -31 | 108,2 | 369 | 93,1 | 0,75 | 2,57 | 0,65 | 143,6 | 1,28 | 2,95 |
-25 | -13 | 195,3 | 667 | 168,0 | 1,00 | 3,42 | 0,86 | 195,2 | 1,44 | 5,35 | |
return gas temp RGT= 32/90 | -15 | 5 | 329,6 | 1126 | 283,6 | 1,29 | 4,41 | 1,11 | 255,2 | 1,67 | 9,08 |
-10 | 14 | 415,8 | 1420 | 357,8 | 1,44 | 4,93 | 1,24 | 288,0 | 1,81 | 11,50 | |
liquid temp | -5 | 23 | 629,1 | 2148 | 541,4 | 1,75 | 5,99 | 1,51 | 358,5 | 2,12 | 17,57 |
Tliq= 55/131 | 0 | 32 | 757,2 | 2586 | 651,7 | 1,91 | 6,53 | 1,65 | 395,8 | 2,30 | 21,28 |
10 | 50 | 900,5 | 3075 | 774,9 | 2,07 | 7,08 | 1,78 | 434,3 | 2,48 | 25,49 |
Configuration 4: R513A, 208-230V/60Hz, CSIR, fan 3m/s, VDE, CB, UL
Optimization + Standard Conditions
Evaporating Pressure (sat. temp.) | Condensing Pressure (sat. temp.) | Return Gas Temp. | Liquid Temp. | Cooling Capacity [W] | [Btu/h] | [kcal/h] | COP [W/W] | EER [Btu/Wh] | [kcal/Wh] | Power Consumption [W] | Current Consumption [A] | Ref. Mass Flow [kg/h] | Application | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
[°C] -23 | [°F] -10 | 54 | 32 | 32 | 330,3 | 1128 | 284,2 | 1,36 | 4,64 | 1,17 | 243,0 | 1,48 | 7,11 | ASHRAE LBP |
[°C] -7 | [°F] 20 | 54 | 35 | 46 | 647,0 | 2210 | 556,8 | 1,75 | 5,96 | 1,50 | 370,5 | 1,95 | 15,85 | ASHRAE MBP |
[°C] 7,2 | [°F] 45 | 54 | 35 | 46 | 1105,2 | 3775 | 951,2 | 2,26 | 7,72 | 1,94 | 489,2 | 2,45 | 27,46 | ASHRAE HBP |
[°C] -35 | [°F] -31 | 40 | 20 | 40 | 173,9 | 594 | 149,7 | 1,12 | 3,83 | 0,97 | 155,0 | 1,21 | 4,30 | EN12900 LBP |
[°C] -10 | [°F] 14 | 45 | 20 | 45 | 560,9 | 1916 | 482,8 | 1,76 | 6,02 | 1,52 | 318,5 | 1,75 | 14,87 | EN12900 MBP |
[°C] 5 | [°F] 41 | 50 | 20 | 50 | 935,4 | 3195 | 805,0 | 2,10 | 7,18 | 1,81 | 444,7 | 2,26 | 26,82 | EN12900 HBP |
Performance Tables
pe [°C] | [°F] | Cooling Capacity [W] | [Btu/h] | [kcal/h] | COP [W/W] | EER [Btu/Wh] | [kcal/Wh] | P1 [W] | I [A] | m [kg/h] | |
---|---|---|---|---|---|---|---|---|---|---|---|
[°C/°F] | |||||||||||
cond. pressure pc= 45/113 | -35 | -31 | 165,5 | 565 | 142,4 | 1,06 | 3,61 | 0,91 | 156,6 | 1,21 | 4,02 |
-25 | -13 | 282,1 | 963 | 242,7 | 1,27 | 4,32 | 1,09 | 222,8 | 1,41 | 6,87 | |
return gas temp. RGT= 32/90 | -15 | 5 | 466,6 | 1594 | 401,6 | 1,63 | 5,56 | 1,40 | 286,8 | 1,63 | 11,43 |
-10 | 14 | 586,6 | 2003 | 504,8 | 1,84 | 6,29 | 1,59 | 318,5 | 1,75 | 14,42 | |
-5 | 23 | 726,1 | 2480 | 624,9 | 2,07 | 7,08 | 1,78 | 350,2 | 1,87 | 17,93 | |
liquid temp Tliq= 45/113 | 0 | 32 | 886,2 | 3026 | 762,6 | 2,32 | 7,92 | 2,00 | 382,2 | 2,00 | 21,98 |
7,2 | 45 | 1154,3 | 3942 | 993,4 | 2,69 | 9,19 | 2,31 | 429,1 | 2,19 | 28,87 | |
[°C/°F] | |||||||||||
cond. pressure pc= 55/131 | -35 | -31 | 132,2 | 451 | 113,8 | 0,82 | 2,82 | 0,71 | 160,3 | 1,22 | 3,60 |
-25 | -13 | 236,1 | 806 | 203,2 | 1,02 | 3,48 | 0,88 | 231,5 | 1,44 | 6,46 | |
return gas temp RGT= 32/90 | -15 | 5 | 394,8 | 1348 | 339,8 | 1,29 | 4,40 | 1,11 | 306,2 | 1,70 | 10,87 |
-10 | 14 | 496,9 | 1697 | 427,6 | 1,44 | 4,91 | 1,24 | 345,3 | 1,85 | 13,74 | |
liquid temp | -5 | 23 | 615,3 | 2101 | 529,5 | 1,59 | 5,45 | 1,37 | 385,9 | 2,02 | 17,09 |
Tliq= 55/131 | 0 | 32 | 750,9 | 2564 | 646,2 | 1,75 | 5,99 | 1,51 | 428,2 | 2,19 | 20,97 |
7,2 | 45 | 978,0 | 3340 | 841,7 | 1,99 | 6,78 | 1,71 | 492,3 | 2,46 | 27,57 |
Electrical Accessories / Wiring Diagram
Diagram showing electrical accessories including a current relay (a5) and start capacitor (c), along with cover and clamp components (b, d).
Component | Part Number |
---|---|
Current relay (T0377/L6-S1) | 117U7071 |
Start capacitor (80μF, 6.3mm) | 117U5001 |
Cover + clamp + screws (5VA-compl.) | 103N0600 |
100x cover + clamp + screws (5VA) | 103N2060 |
Cover + clamp + screws (5VA) in bag | 103N1060 |
Ambient/Machine Room Temperatures
Parameter | Value |
---|---|
Ambient temperature range | 10 - 43°C / 50 - 110°F |
Machine room temperature range | 10 - 48°C / 50 - 119°F |
Compressor cooling | fan 3m/s |
Operation Pressure Range
Graph showing the operation pressure range. The Y-axis represents condensing pressure (sat. temp.) in bar and °C/°F. The X-axis represents evaporation pressure (sat. temp.) in bar and °C/°F. Two lines indicate continuous and transitory operation zones.