SECOP KLE.5.6GFTX Compressor Technical Data

Model Designation: KLE.5.6GFTX

Sales Code: 106G5613

Compressor Design

Designation KLE.5.6GFTX
Voltage/Frequency 220-240V/50Hz 1~   |   208-230V/60Hz 1~
Oil type Polyolester
Oil viscosity 19,2cSt
Oil quantity 240cm³ / 8,1fl.oz
Refrigerant charge - tech. limit 250g / 8,8oz
Free gas volume comp. 1535cm³ / 51,9fl.oz
Weight 9,5kg / 20,9lbs
Motor protection external
Winding resistance main 10,7Ω (at 25°C)
Winding resistance aux 17Ω (at 25°C)
Max. winding temp. 125°C / 257°F
Max. discharge temp. 130°C / 266°F
Additional note Good robustness against liquid intake. Ice-cube maker optimization - indirect suction intake.
Refrigerant(s) R134a, R513A, 0
Displacement 5,6cm³ / 0,34cu.in
Compressors on pallet 100

Image Description: A black SECOP KL-Series compressor is shown, featuring a silver label and various ports. The image provides a visual representation of the compressor unit.

General Configurations with KLE.5.6GFTX

Parameter Conf. 1 Conf. 2
Motor configuration CSIR CSIR
Power supply (nominal) 220-240V/50Hz 208-230V/60Hz
Number of phases 1 1
Voltage range 187-254V 198-253V
Approvals VDE, CB, UL VDE, CB, UL
Starting torque HST HST
Note Electrical equipment is included and pre-assembled to compressor.

Applications with KLE.5.6GFTX

Parameter Conf. 1 Conf. 2
Refrigerant R134a R134a
Application LBP+MBP+HBP LBP+MBP
System cooling fan 3m/s ? fan 3m/s ?
Hot gas defrost OK ✔️ OK ✔️
Long interval pull down OK ✔️ OK ✔️

Electrical Data - Configurations with KLE.5.6GFTX

Parameter Conf. 1 Conf. 2
Starting device type relay ⚙️ relay ⚙️
Run capacitor -/- -/-
Start capacitor 80µF 80µF
LRA (locked rotor amps / 4s/ U(N)) 11,4A
RLA (rated load amps / 1s/ U(N)) 1,2A
Cut in current (U(N)) 10,7A

Compressor Dimensions

Dimension Value
A Height 182mm / 7,17in
B Height 175mm / 6,89in
C Length shell 198mm / 7,8in
D Length w. cover 238mm / 9,37in
E Width 160mm / 6,3in

Diagram Description (Compressor Dimensions): A schematic illustrates the external dimensions of the compressor, labeled A (Height), B (Height - alternative), C (Length shell), D (Length with cover), and E (Width), with measurements provided in millimeters and inches.

Connectors

Parameter Configuration
Suction (X) Discharge (Y) Process (Z)
Diameter [mm] (i:inside, o:outside) ⌀i 8,11-8,29 ⌀i 6,11-6,29 ⌀i 6,11-6,29
Diameter [in] (i:inside, o:outside) ⌀i 0,32-0,33 ⌀i 0,24-0,25 ⌀i 0,24-0,25
Material copper copper copper
Horizontal angle +2° 35°
Vertical angle +2° 30° 145°
Position l/h/w [mm] 119/73/59 117/107/66 -88/101/71
Position l/h/w [in] 4,7/2,9/2,3 4,6/4,2/2,6 -3,5/4/2,8
Straight tube l. [mm] 14 14 14
Straight tube l. [in] 0,5 0,5 0,5

Diagram Description (Connectors): A diagram illustrates the three main ports: Suction (X), Discharge (Y), and Process (Z). It details their diameters in mm and inches, material (copper), and angular positions (horizontal and vertical). It also shows the position (l/h/w) and straight tube length for each connector.

Compressor Fixation

Baseplate [mm] Baseplate [inch]
BI Bw E BI Bw E
204 132 ⌀ 9.7 8.03 5.2 ⌀ 0.38
Large holes [mm] Large holes [inch]
Ll Lw ⌀L Ll Lw ⌀L
165 101.6 ⌀ 19 6.5 4 ⌀ 0.75
Small holes [mm] Small holes [inch]
Sl Sw ⌀S Sl Sw ⌀S
170 70 ⌀ 16 6.7 2.76 ⌀ 0.63

Diagram Description (Compressor Fixation): A diagram shows the compressor baseplate with dimensions for large and small mounting holes, indicated by Bl, Bw, E, Ll, Lw, ØL, Sl, Sw, and ØS. It also illustrates bolt joint and snap-on mounting methods, detailing components like washers, nuts, sleeves, clips, and steel pins used to secure the compressor to a cabinet base.

Mounting Accessories

Accessory Type One Comp. Multi Pack
Bolt joint | M6 | Ø16mm 118-1917 118-1918
Bolt joint | Ø1/4" | Ø16mm 118-1946
Bolt joint | Ø1/4" | Ø19mm 118-1949
Snap-on | Ø7,3 | Ø16mm 118-1947 118-1919

Application Notes

Optimization + Standard Conditions

Refrigerant: R134a, Voltage/Frequency: 220V/50Hz, Motor Type: CSIR, Cooling: fan 3m/s, Approvals: VDE, CB, UL

Evaporating Pressure (Saturation Temperature) Condensing Pressure (Saturation Temperature) Return Gas Temp. Liquid Temp. Cooling Capacity COP EER Power Consumption Current Consumption Ref. Mass Flow [kg/h]
[W] [Btu/h] [kcal/h] [W/W] [Btu/Wh] [kcal/Wh] [W] P1 I [A]
pe [°C] -23
[°F] -10
pc 54
130
RGT 32
90
Tliq 32
90
156,4 534 134,6 1,32 4,51 1,14 118,5 1,22 3,04 ASHRAE LBP
pe [°C] -7
[°F] 20
pc 54
130
RGT 35
95
Tliq 46
115
335,5 1146 288,7 1,92 6,55 1,65 174,9 1,37 7,32 ASHRAE MBP
pe [°C] 7,2
[°F] 45
pc 54
130
RGT 35
95
Tliq 46
115
601,5 2054 517,6 2,74 9,35 2,36 219,7 1,53 13,34 ASHRAE HBP
pe [°C] -35
[°F] -31
pc 40
104
RGT 20
68
Tliq 40
104
81,5 278 70,1 0,98 3,36 0,85 82,8 1,15 1,79 EN12900 LBP
pe [°C] -10
[°F] 14
pc 45
113
RGT 20
68
Tliq 45
113
289,8 990 249,4 1,92 6,56 1,65 150,8 1,30 6,78 EN12900 MBP
pe [°C] 5
[°F] 41
pc 50
122
RGT 20
68
Tliq 50
122
513,1 1752 441,6 2,52 8,62 2,17 203,2 1,47 12,93 EN12900 HBP

Performance Tables (R134a, 220V/50Hz, CSIR, fan 3m/s, VDE, CB, UL)

Condition Cooling Capacity COP EER Power Consumption Current Consumption Ref. Mass Flow [kg/h]
[W] [Btu/h] [kcal/h] [W/W] [Btu/Wh] [kcal/Wh] [W] P1 I [A]
Cond. pressure pc= 45/113
Return gas temp. RGT= 32/90
Liquid temp. Tliq= 45/113
76,7 262 66,0 0,93 3,18 0,80 82,3 1,15 1,65
135,0 461 116,2 1,23 4,21 1,06 109,5 1,20 2,93
234,2 800 201,5 1,71 5,84 1,47 137,0 1,26 5,10
300,6 1027 258,7 1,99 6,81 1,72 150,8 1,30 6,58
470,6 1607 405,0 2,64 9,00 2,27 178,5 1,38 10,41
575,3 1965 495,1 2,99 10,21 2,57 192,4 1,43 12,81
827,6 2827 712,3 3,76 12,85 3,24 220,0 1,54 18,75
Cond. pressure pc= 55/131
Return gas temp. RGT= 32/90
Liquid temp. Tliq= 55/131
62,9 215 54,1 0,81 2,78 0,70 77,2 1,13 1,50
114,7 392 98,7 1,02 3,47 0,88 112,7 1,20 2,74
201,0 686 173,0 1,36 4,66 1,17 147,4 1,29 4,84
258,7 883 222,6 1,57 5,37 1,35 164,4 1,34 6,25
406,4 1388 349,7 2,06 7,02 1,77 197,7 1,45 9,94
497,7 1700 428,3 2,33 7,95 2,00 213,9 1,51 12,26
718,4 2453 618,2 2,93 10,00 2,52 245,3 1,64 18,04

General Configurations with KLE.5.6GFTX (Conf. 2)

Voltage/Frequency: 208-230V/60Hz

Parameter Conf. 2
Motor configuration CSIR
Power supply (nominal) 208-230V/60Hz 1~
Refrigerant R134a
Application LBP+MBP
Voltage range 198-253V
Starting torque HST
Approvals VDE, CB, UL

Ambient/Machine Room Temperatures Minimum/Maximum

Operation Pressure Range

Diagram Description (Operation Pressure Range): This graph plots Condensing Pressure (sat. temp.) in bar against Evaporation Pressure (sat. temp.) in bar. It displays the operating envelopes for "continuous operation" and "transitory operation" across various temperature ranges, indicated by lines and shaded areas.

Evaporation Pressure Range

Diagram Description (Evaporation Pressure Graph): A smaller graph showing Condensing Pressure (sat. temp.) in bar against Evaporation Pressure (sat. temp.) in bar, focusing on lower pressure ranges for operational assessment.

Electrical Accessories / Wiring Diagram

Diagram Description (Electrical Accessories / Wiring Diagram): This diagram illustrates the electrical components and their connections for the compressor. It includes a current relay (a5), a start capacitor (c), and a cover/clamp/screws assembly (b, d), showing how they are wired together.

Components (incl. and pre. assembl.)

Component Part Number
a5 current relay (T0089/L6-S2) 117U7070
c start capacitor (80µF, 6.3mm) 117U5001
b, d cover + clamp + screws(5VA-compl.) 103N0600

Alternative Components

Component Part Number
b, d 100x cover + clamp + screws(5VA) 103N2060
b, d cover + clamp + screws(5VA) in bag 103N1060

Optimization + Standard Conditions (Conf. 2)

Refrigerant: R134a, Voltage/Frequency: 230V/60Hz, Motor Type: CSIR, Cooling: fan 3m/s, Approvals: VDE, CB, UL

Evaporating Pressure (Saturation Temperature) Condensing Pressure (Saturation Temperature) Return Gas Temp. Liquid Temp. Cooling Capacity COP EER Power Consumption Current Consumption Ref. Mass Flow [kg/h]
[W] [Btu/h] [kcal/h] [W/W] [Btu/Wh] [kcal/Wh] [W] P1 I [A]
pe [°C] -23
[°F] -10
pc 54
130
RGT 32
90
Tliq 32
90
192,7 658 165,9 1,37 4,69 1,18 140,3 1,18 3,74 ASHRAE LBP
pe [°C] -7
[°F] 20
pc 54
130
RGT 35
95
Tliq 46
115
396,6 1354 341,3 1,95 6,65 1,68 203,6 1,35 8,65 ASHRAE MBP
pe [°C] 7,2
[°F] 45
pc 54
130
RGT 35
95
Tliq 46
115
702,9 2401 605,0 2,73 9,31 2,35 257,8 1,53 15,59 ASHRAE HBP
pe [°C] -35
[°F] -31
pc 40
104
RGT 20
68
Tliq 40
104
99,0 338 85,2 1,07 3,66 0,92 92,3 1,09 2,17 EN12900 LBP
pe [°C] -10
[°F] 14
pc 45
113
RGT 20
68
Tliq 45
113
340,9 1164 293,4 1,91 6,54 1,65 178,1 1,27 7,98 EN12900 MBP
pe [°C] 5
[°F] 41
pc 50
122
RGT 20
68
Tliq 50
122
598,3 2043 514,9 2,48 8,46 2,13 241,6 1,47 15,08 EN12900 HBP

Performance Tables (R134a, 230V/60Hz, CSIR, fan 3m/s, VDE, CB, UL)

Condition Cooling Capacity COP EER Power Consumption Current Consumption Ref. Mass Flow [kg/h]
[W] [Btu/h] [kcal/h] [W/W] [Btu/Wh] [kcal/Wh] [W] P1 I [A]
Cond. pressure pc= 45/113
Return gas temp. RGT= 32/90
Liquid temp. Tliq= 45/113
92,3 315 79,4 1,01 3,46 0,87 91,2 1,08 1,99
165,3 565 142,3 1,30 4,43 1,12 127,3 1,15 3,58
278,6 951 239,7 1,73 5,90 1,49 161,3 1,23 6,07
353,6 1208 304,3 1,99 6,78 1,71 178,1 1,27 7,74
547,6 1870 471,2 2,57 8,79 2,21 212,8 1,38 12,11
669,1 2285 575,8 2,89 9,88 2,49 231,2 1,44 14,90
968,2 3307 833,3 3,57 12,18 3,07 271,5 1,57 21,93
Cond. pressure pc= 55/131
Return gas temp. RGT= 32/90
Liquid temp. Tliq= 55/131
72,1 246 62,1 0,78 2,66 0,67 92,6 1,08 1,72
141,6 484 121,9 1,05 3,60 0,91 134,3 1,16 3,39
242,5 828 208,7 1,40 4,79 1,21 172,9 1,26 5,84
308,1 1052 265,1 1,61 5,49 1,38 191,8 1,31 7,45
476,4 1627 410,0 2,07 7,08 1,78 229,8 1,43 11,65
581,9 1987 500,8 2,33 7,96 2,01 249,6 1,50 14,34
842,3 2877 724,9 2,88 9,85 2,48 292,0 1,65 21,16

PDF preview unavailable. Download the PDF instead.

kle56gftx 106g5613 r134a 220v 208v 50hz 60hz 08-2025 ds Microsoft Excel für Microsoft 365

Related Documents

Preview SECOP KLE.6GFTX Compressor Technical Data Sheet
Detailed technical specifications, performance data, dimensions, and configuration options for the SECOP KLE.6GFTX compressor, designed for R134a refrigerant.
Preview SECOP KLE.6.6GFTX Compressor Technical Data Sheet - R134a, 220V/50Hz & 208V/60Hz
Detailed technical specifications, performance data, dimensions, and electrical information for the SECOP KLE.6.6GFTX compressor, compatible with R134a refrigerant and operating at 220V/50Hz and 208V/60Hz.
Preview SECOP KLE8.6GFTX Compressor Technical Data Sheet
Detailed technical specifications, configurations, performance data, and dimensions for the SECOP KLE8.6GFTX compressor, supporting R134a and R513A refrigerants for various voltage and frequency combinations.
Preview Secop KLE-GFTX Compressors: Robust and Efficient Solutions for Light Commercial Refrigeration
Discover the Secop KLE-GFTX series of compressors, offering premium robustness, excellent efficiency, and reduced noise and vibration for high-efficiency cabinets in food retail and food service applications. Learn about their technical specifications, performance data, and applications.
Preview SECOP KLE5.6GFTX Compressor Technical Data Sheet
Detailed technical specifications, configurations, electrical data, dimensions, and performance tables for the SECOP KLE5.6GFTX compressor, covering operating ranges and electrical accessories for 220-240V/50Hz and 208-230V/60Hz configurations.
Preview SECOP KLE6.6GFTX Compressor Technical Data Sheet
Detailed technical specifications, dimensions, electrical data, and performance tables for the SECOP KLE6.6GFTX compressor, compatible with R134a and R513A refrigerants. Includes configuration options and operating parameters.
Preview SECOP KLE8.6GFTX Compressor Technical Data Sheet
Comprehensive technical specifications, performance data, dimensions, and configuration details for the SECOP KLE8.6GFTX compressor, including R134a and R513A refrigerant compatibility.
Preview SECOP FRK11G Compressor Technical Data Sheet - Specifications and Performance
Detailed technical data sheet for the SECOP FRK11G compressor, including specifications, performance tables, and application details for R134a and R513A refrigerants across various voltage and frequency configurations.