Legrand DMX³ 2500 Circuit Breakers and DMX³-I 2500 Trip-Free Switches

Technical Data Sheet

1. Use

DMX³ air circuit breakers provide optimal solutions for protection requirements in low voltage electrical installations (IEC/EN 60364-1) up to 6300 A. Their electric and mechanical robustness, breaking capacity, and accessorizing options make them suitable for demanding applications. The DMX³ series also includes trip-free switches (I series) offering high performance in insulation, robustness, closing, and withstand capability. Both series are designed for increased continuity of service, energy efficiency, and environmental considerations.

2. Range

2.1 DMX³ 2500 Fixed Version (PU MP2.10/MP4.10)

Tables detailing available models for 50 kA, 65 kA, and 100 kA breaking capacities, with 3-pole and 4-pole options.

2.2 DMX³ 2500 Draw-out Version (PU MP2.10/MP4.10)

Tables detailing available models for 50 kA, 65 kA, and 100 kA breaking capacities, with 3-pole and 4-pole options.

2.3 DMX³-I 2500 Trip-Free Switches (Fixed/Draw-out Version with PU MP2.10/MP4.10)

Tables detailing available models for fixed and draw-out versions with 3-pole and 4-pole options for DMX³-I 2500.

2.4 Composition

Diagrams illustrating the main parts of the circuit breaker for both fixed and draw-out versions. Key components include:

3. Technical Characteristics

3.1 Electrical Characteristics

Detailed tables provide electrical specifications for the DMX³ 2500 circuit breaker, including:

Similar tables are provided for the DMX³-I 2500 trip-free switches.

3.2 Phases Limit Trip Current

Table detailing thermal (Ir) and magnetic (Isd) trip current settings for various rated currents.

3.3 Mechanical Characteristics

Information on endurance (mechanical and electrical cycles) and electrodynamic forces.

3.4 Power Losses per Pole at In/Ie

Tables showing power losses for both fixed and draw-out versions of DMX³ 2500 and DMX³-I 2500.

3.5 Electronic Protection Unit

Details on the MP2.10 and MP4.10 electronic protection units, including features, protective functions (overloads, short-circuits, earth faults), and configuration options. Information on optional power supplies and accessories is also provided.

4. Installation Rules

Temperature Derating

Tables provide temperature derating factors for DMX³ 2500 and DMX³-I 2500 (fixed and draw-out versions) at various ambient temperatures, indicating maximum allowable current (Imax) and the ratio Ir/In.

Altitude Derating

Table shows altitude derating for rated current and voltage for DMX³ and DMX³-I.

5. Dimensions and Weights

5.1 Dimensions

Detailed dimension drawings and tables for DMX³ 2500 and DMX³-I 2500 (fixed and draw-out versions), showing height, depth, and width for 3-pole and 4-pole configurations.

5.2 Weights

Tables listing the weights for DMX³ 2500 and DMX³-I 2500 (fixed and draw-out versions).

5.3 Fixed Version Dimensions

Frontal, rear, and lateral views with dimensions for fixed versions (DMX³ with Icu=50 kA, 65 kA, and DMX³-I).

5.4 Draw-out Version Dimensions

Frontal, rear, and lateral views with dimensions for draw-out versions (DMX³ with Icu=50 kA, 65 kA, and DMX³-I).

5.5 Fixed Version Dimensions (Icu=100 kA)

Frontal, rear, and lateral views with dimensions for fixed versions (DMX³ with Icu=100 kA).

5.6 Draw-out Version Dimensions (Icu=100 kA)

Frontal, rear, and lateral views with dimensions for draw-out versions (DMX³ with Icu=100 kA).

6. Electrical Connections

Guidelines for selecting products and connecting busbars. Tables specify minimum cross-sections of copper busbars for various rated currents and configurations (fixed and draw-out versions).

7. Equipments and Accessories

7.1 Terminals and Spreaders

Details and Cat.Nos for various terminals and spreaders, including rear terminals for fixed and draw-out versions, spreaders for flat and vertical connections, and aluminium rear terminals.

7.2 Control Auxiliaries

Information on shunt trips, undervoltage releases, motor operators, and modules for delayed tripping, including their specifications and Cat.Nos.

7.3 Signalling Auxiliaries

Details on signalling contacts for draw-out versions and auxiliary signalling contacts.

7.4 Locking

Information on universal key locks, key locking supports, and door locking mechanisms.

7.5 Mechanical Operations Counter

Details on the mechanical operations counter.

7.6 Rating Mis-insertion Device

Information on the device to prevent mis-insertion of draw-out circuit breakers.

7.7 Lifting Plate

Details on the lifting plate.

7.8 Fixing Devices

Information on fixing devices for DMX³ and DMX³-I 2500.

7.9 Equipment for Conversion

Details on bases for draw-out devices and transformation kits for draw-out versions.

7.10 Equipment for Interlocking

Information on mechanical interlock systems for DMX³ 2500.

7.11 Interlock Cables

Details on available interlock cable lengths and their Cat.Nos.

7.12 Insulating Shields

Details on insulating shields for fixed and draw-out versions.

8. Marking

Information on product marking, including laser labels on the front and side, packaging sticker labels, and conformity marks.

9. Curves

9.1 Tripping Curve for DMX³ 2500 MPx.10 Protection Units (L-T Protection Detail)

Graph illustrating the tripping time versus current for long-time delay protection.

9.2 Tripping Curve for DMX³ 2500 MPx.10 Protection Units (Short Time Trip Protection Detail)

Graph illustrating the tripping time versus current for short-time trip protection.

9.3 Tripping Curve for DMX³ 2500 MPx.10 Protection Units (Instantaneous Trip Protection Detail)

Graph illustrating the tripping time versus current for instantaneous trip protection.

9.4 Ground Fault Curve for DMX³ 2500 MPx.10 Protection Units

Graph illustrating the tripping time versus ground fault current.

9.5 Pass-through Specific Energy Curve (at 415 V)

Graph illustrating pass-through energy versus short-circuit current.

10. Conformity

Information on compliance with IEC/EN standards (60947-2, 60947-3), certifications (IECEE CB-scheme, LOVAG), and compliance with RoHS, REACH, and WEEE directives. Packaging compliance with European Directive 94/62/CE is also mentioned.

11. Other Information

Details on Legrand software tools like XLPro Calcul, XLPro³ Tool Selectivity and backup, and XLPro Panels. Information on workshop books, instruction sheets, and PEP documents available on e-catalog. Contact information for technical support is provided.

PDF preview unavailable. Download the PDF instead.

F03884EN 01 Adobe PDF Library 17.0 Adobe InDesign 20.4 (Windows)

Related Documents

Preview Legrand DMX³ 2500 Open Circuit Breakers and Switches Technical Data
Technical data sheet for Legrand DMX³ 2500 open circuit breakers and DMX³-I 2500 open switches, covering specifications, installation rules, dimensions, weights, electrical connections, accessories, tripping curves, and compliance with standards.
Preview Legrand DMX³ 4000 & DMX³-I 4000 Circuit Breakers & Trip Free Switches - Technical Data Sheet
Comprehensive technical data sheet for Legrand DMX³ 4000 circuit breakers and DMX³-I 4000 trip free switches, covering specifications, installation, accessories, and conformity. Includes MP2.10 and MP4.10 protection units.
Preview Legrand S10MPX.10 Bluetooth BLE Dongle: Installation, Features, and Compliance
Technical data sheet for the Legrand S10MPX.10 Bluetooth BLE Dongle. This device interfaces with DPX3 and DMX3 switches, enabling advanced functions via the EnerUp+ Project app. Details include dimensions, installation, power, features, and compliance information.
Preview Legrand DPX³ 160 Thermal Magnetic Circuit Breakers with Earth Leakage - Technical Data
Comprehensive technical data sheet for Legrand DPX³ 160 thermal magnetic circuit breakers and DPX³-I 160 trip-free switches with earth leakage, covering specifications, installation, dimensions, and performance curves.
Preview Legrand DPX³ 250 Thermal-Magnetic Circuit Breakers - Technical Data
Technical data sheet for Legrand DPX³ 250 thermal-magnetic circuit breakers and DPX³-I 250 trip-free circuit breakers, covering electrical and mechanical characteristics, installation guidelines, dimensions, and accessories.
Preview Legrand DPX³ 250 Thermal Magnetic Circuit Breakers with Earth Leakage - Technical Data
Comprehensive technical data for Legrand DPX³ 250 thermal magnetic circuit breakers and DPX³-I 250 trip-free switches with earth leakage, covering specifications, installation rules, dimensions, accessories, and tripping curves.
Preview Legrand DPX³ 160 Magnetic Thermal Circuit Breakers and Free Release Miniature Circuit Breakers
Technical datasheet for Legrand DPX³ 160 magnetic thermal circuit breakers and DPX³-I 160 free release miniature circuit breakers, covering technical specifications, installation guidelines, dimensions, accessories, and standards compliance.
Preview Legrand DPX³ 160 Thermal Magnetic Circuit Breakers and DPX³-I 160 Trip-Free Switches - Technical Data
Comprehensive technical data for Legrand DPX³ 160 thermal magnetic circuit breakers and DPX³-I 160 trip-free switches, covering specifications, installation, dimensions, accessories, and standards.