R. STAHL Galvanic Isolators: Binary Output without Auxiliary Power Supply, Ex i Field Circuit

Model: 9176/20-16-00s | Article No.: 222184

Product Overview

The R. STAHL 9176A series binary outputs provide binary signals for the operation of Ex i solenoid valves, indicator lamps, or sirens. These devices do not require a separate auxiliary power supply as they are powered by the control circuit. The intrinsically safe outputs are electrically isolated from the inputs. Two-channel variants feature electrically separated channels.

Technical Characteristics

Explosion Protection

Application Area (Zones) 0, 1, 2, 20, 21, 22
Interface Ex Zone IECEx BVS 13.0012 X
IECEx Protection Against Explosion of Gas Ex nA [ia Ga] IIC T4 Gc
Certificates IECEx BVS 13.0012 X, BVS 04 ATEX E 075 X, FM16US0122X, FM16CA0067X, CCS, EU RO MR (DNV), ATEX (EUK), China (CCC)
Certificates for Gas Explosion Protection [Ex ia Da] IIIC
Certificates for Dust Explosion Protection II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
ATEX Protection Against Explosion of Gas II (1) D [Ex ia Da] IIIC
ATEX Protection Against Explosion of Dust Class I, Div. 2, Groups A,B,C,D; Class I, Zone 2, Group IIC; AIS Class I,II,III, Div. 1, Groups A,B,C,D,E,F,G; Class I, Zone 0, [AEx ia]/[Ex ia] IIC
Marine Approval CCS, EU RO MR (DNV)

Safety Values

Maximum Voltage Uo 27.6 V
Maximum Current Io (Ex ia) 110 mA
Maximum Current Io (Ex ib) 50 mA
Maximum Power Po 760 mW
Max. External Capacitance Co for IIC 0.085 μF
Max. External Inductance Lo for IIC 1.2 mH
Max. External Capacitance Co for IIB 0.667 μF
Max. External Inductance Lo for IIB 9 mH
Internal Capacitance 1.1 nF
Internal Inductance Negligible
Max. Parallel Voltage Uo 27.6 V
Max. Parallel Power Po 1520 mW
Max. Parallel Current Io (Ex ia) 220 mA
Max. Parallel Current Io (Ex ib) 100 mA
Parallel Internal Capacitance 2.2 nF
Parallel Internal Inductance Negligible
Maximum Technical Safety Voltage 253 V

Intrinsically Safe Limit Values (Inductance L / Capacitance C) for Connection

Inductance L / Capacitance C Connectable
2 Channels in Parallel
IIC L. [mH]: 1.8 mH
C. [μF]: 0.665 μF
L. [mH]: 1.800 mH
C. [μF]: 0.665 μF

Electrical Characteristics

Number of Channels 2
Internal Resistance R 250 Ω
Auxiliary Power Supply None
Power Consumption of Auxiliary Supply 0.5 W + (I x 37 mW/mA)
Reverse Polarity Protection Yes
Electrical Isolation
Test Voltage (according to standard) Input Ex i to Input Ex i EN IEC 60079-11, 500 V AC
Test Voltage (according to standard) Input to Input EN 50178, 350 V AC

Input

Input (according to EN 61131-2)
Input Voltage for ON 18 – 31.2 V
Input Voltage for OFF 0 – 5 V

Output

Control Power PE 0.5 W + (IA x 37 mW / mA) (with IA = required max. output current)
Output Voltage at No Load Uo 25 V
Maximum Output Current Ia 35 mA
Maximum Output Current Ia (Parallel Channels) 70 mA
Output Internal Resistance R 250 ohms / Parallel: 125 ohms
Output Residual Ripple < 100 mV
Output Switching Frequency ≤ 10 Hz
Switching Delay ON/OFF ≤ 50 ms
Switching Delay OFF/ON ≤ 18 ms
Switching Status Indication Yellow LED "OUT"

Output Characteristic Curve

The output characteristic curve for models 9175/.0-16-11 and 9176/.0-16-00 is provided. Curve A represents the characteristic per channel, and Curve B represents the characteristic for 1 parallel channel (for types 9176/20-...).

Graph Description: The graph displays current (I [mA]) on the x-axis and voltage (U [V]) on the y-axis. The x-axis ranges from 0 to 45 mA, and the y-axis ranges from 0 to 25 V. Curve A shows a characteristic for a single channel, while Curve B shows a characteristic for two parallel channels.

Ambient Conditions

Ambient Temperature (Single Device) -20 °C ... +70 °C (-4 °F ... +158 °F)
Ambient Temperature (Group Assembly) -20 °C ... +60 °C (-4 °F ... +140 °F)
Note on Ambient Conditions Installation conditions influence ambient temperature. Refer to "Installation Instructions - Control Cabinet".
Storage Temperature -40 °C ... +80 °C (-40 °F ... +176 °F)
Maximum Relative Humidity 95%
Altitude Use < 2000 m
Electromagnetic Compatibility Complies with standards and directives: EN 61326-1, use in industrial sector; NAMUR NE 21

Mechanical Characteristics

Degree of Protection (IP) IP30
Degree of Protection (IP) Pins IP20
Fire Resistance (UL 94) V0
Enclosure Material Polyamide
Pitch 17.6 mm (0.69 in)
Width 17.6 mm (0.69 in)
Height 114.5 mm (4.51 in)
Length 108 mm (4.25 in)
Weight 185 g (0.41 lb)
Mounting / Installation Rail DIN NS35/15, NS35/7.5
Mounting Position Vertical, Horizontal
Connection Type Screw Terminal
Rigid Conductor Cross-Section (Min.) 0.2 mm²
Rigid Conductor Cross-Section (Max.) 2.5 mm²
Flexible Conductor Cross-Section (Min.) 0.2 mm²
Flexible Conductor Cross-Section (Max.) 2.5 mm²
AWG Connection Cross-Section 24 ... 14

Accessories

Transparent Cover for ISpac 91xx Modules (Yellow, Transparent) Art. No. 200914
(Packaging unit: 10 pieces)

Spare Parts

Screw Terminals

3-pole plug, screw connection, M3 thread, 7 mm stripping length, green color Art. No. 112817
3-pole plug, screw connection, M3 thread, 7 mm stripping length, black color Art. No. 112816
3-pole plug, screw connection, M3 thread, 7 mm stripping length, blue color Art. No. 112818

Screw Terminals with Control Contact

3-pole plug with control contact, screw connection, M3 thread, 7 mm stripping length, black color Art. No. 113005
3-pole plug with control contact, screw connection, M3 thread, 7 mm stripping length, blue color Art. No. 113004

Spring Terminals

3-pole plug with control contact, spring terminal, 10 mm stripping length, green color Art. No. 112825
3-pole plug with control contact, spring terminal, 10 mm stripping length, black color Art. No. 112824
3-pole plug with control contact, spring terminal, 10 mm stripping length, blue color Art. No. 112826

Subject to technical modifications, dimensions, weights, construction types, and delivery possibilities. Figures are for illustrative purposes only.

PDF preview unavailable. Download the PDF instead.

ex-single-data-sheet-loop-powered-binary-output-ex-i-field-circuit-9176-20-16-00s-222184-fr-fr-rstahl Adobe PDF Library 17.0

Related Documents

Preview R. STAHL 9176A Galvanic Isolator: Ex i Field Circuit Output
Technical specifications and features of the R. STAHL 9176A loop-powered binary output Ex i field circuit isolator, including safety, electrical, and mechanical characteristics.
Preview R. STAHL 9176A Galvanic Isolator: Ex i Field Circuit Output
Technical specifications and features of the R. STAHL 9176A loop-powered binary output galvanic isolator for Ex i field circuits. Details on safety, electrical characteristics, environmental conditions, and mechanical specifications.
Preview R. STAHL 9176A Galvanic Isolator: Technical Specifications and Features
Detailed technical specifications, safety features, and application information for the R. STAHL 9176A loop-powered binary output galvanic isolator for Ex i field circuits. Includes ATEX, IECEx, and cFM certifications.
Preview R. STAHL 9176/20-16-00s Loop-Powered Binary Output Isolator Barrier
Technical data and specifications for the R. STAHL 9176/20-16-00s loop-powered binary output isolator barrier for Ex i field circuits. Features include intrinsic safety, galvanic separation, and suitability for solenoid valves and signaling devices.
Preview R. STAHL 9176/20-16-00s Loop-Powered Binary Output Isolator for Ex i Field Circuits
Technical specifications and data for the R. STAHL 9176/20-16-00s loop-powered binary output isolator, designed for intrinsically safe operation of Ex i solenoid valves, indicator lamps, and horns in hazardous areas.
Preview R. STAHL 9176A Series: Loop-Powered Binary Output Ex i Field Circuit Isolators
Technical data and specifications for the R. STAHL 9176A series of loop-powered binary output isolators for Ex i field circuits. Details include safety data, electrical characteristics, environmental conditions, mechanical data, and accessories.
Preview R. STAHL 9176/20-16-00k Galvanic Isolator: Technical Specifications and Features
Detailed technical specifications, safety features, and electrical characteristics of the R. STAHL 9176/20-16-00k loop-powered binary output Ex i field circuit galvanic isolator. Includes ATEX and IECEx certifications, environmental conditions, and mechanical data.
Preview R. STAHL 9176A/20-15-00k Galvanic Isolator: Ex i Field Circuit Output
Technical specifications and features of the R. STAHL 9176A/20-15-00k loop-powered binary output Ex i field circuit isolator. Details on safety, electrical characteristics, mechanical properties, and accessories.