R. STAHL 9176A Galvanic Isolator

Loop-powered binary output for Ex i field circuits

Article Number: 222182

Product Overview

The R. STAHL 9176A series galvanic isolators provide binary signals for intrinsically safe operation of Ex i solenoid valves, indicator lamps, or sirens. These devices are powered by the control circuit, eliminating the need for a separate auxiliary power supply. The intrinsic safety outputs are electrically isolated from the inputs. Two-channel variants feature electrical channel separation.

Technical Characteristics

Explosion Protection

Application Domain (Zones) 0, 1, 2, 20, 21, 22
Interface Ex Zone IECEx BVS 13.0012 X
IECEx Protection Against Explosion of Gas Ex nA [ia Ga] IIC T4 Gc
IECEx Protection Against Explosion of Dust [Ex ia Da] IIIC
ATEX Gas Certificate BVS 04 ATEX E 075 X
ATEX Protection Against Explosion of Gas II 3 (1) G Ex nA [ia Ga] IIC T4 Gc
ATEX Dust Certificate BVS 04 ATEX E 075 X
ATEX Protection Against Explosion of Dust II (1) D [Ex ia Da] IIIC
FM16US0122X FM16US0122X
FM16CA0067X FM16CA0067X
cFMus Marking Class I, Div. 2, Groups A,B,C,D; Class I, Zone 2, Group IIC
AIS Class I,II,III, Div. 1, Groups A,B,C,D,E,F,G; Class I, Zone 0, [AEx ia]/[Ex ia] IIC
T4 Mounting vert. at Ta = 70°C, or horizontal Ta = 60°C

Certifications

ATEX (BVS) Brazil (ULB) Canada (FM) China (NEPSI) Korea (KTL) USA (FM) IECEx (BVS) SIL (exida)
Marine Approval: CCS, EU RO MR (DNV)
Conformity Certificate: ATEX (EUK), China (CCC)

Safety Values

Maximum Voltage Uo 27.6 V
Maximum Current Io (Ex ia) 110 mA
Maximum Current Io (Ex ib) 50 mA
Maximum Power Po 760 mW
Max. External Capacitance Co for IIC 0.085 μF
Max. External Inductance Lo for IIC 1.2 mH
Max. External Capacitance Co for IIB 0.667 μF
Max. External Inductance Lo for IIB 9 mH
Internal Capacitance 1.1 nF
Internal Inductance Negligible
Max. Voltage Uo Parallel 27.6 V
Max. Current Io (Ex ia) Parallel 220 mA
Maximum Technical Safety Voltage 253 V

Electrical Characteristics

Number of Channels 1
Auxiliary Power None
Auxiliary Power Consumption 0.5 W + (I x 37 mW/mA)
Reverse Polarity Protection Yes

Electrical Isolation

Test Voltage According to Standard EN IEC 60079-11
Test Voltage According to Standard EN 50178
Input to Input 350 V AC

Input

Input Voltage for SWITCH ON 18-31.2 V
Input Voltage for SWITCH OFF 0-5 V
Control Power PE 0.5 W + (I x 37 mW / mA) (with IA = required max. output current)

Output

Output Voltage Under No Load U 25 V
Maximum Output Current Io 35 mA
Output Internal Resistance R 250 Ω
Output Residual Ripple < 100 mV
Output Switching Frequency ≤ 10 Hz
Switching Delay SWITCH ON/OFF ≤ 50 ms
Switching Delay SWITCH OFF/ON ≤ 18 ms
Switching Status Indication Yellow LED "OUT"

Environmental Conditions

Ambient Temperature (Single Device) -20 °C ... 70 °C (-4 °F ... +158 °F)
Ambient Temperature (Group Mounting) -20 °C ... 60 °C (-4 °F ... +140 °F)
Storage Temperature -40 °C ... 80 °C (-40 °F ... +176 °F)
Maximum Relative Humidity 950%
Usage at Altitude < 2000 m
Electromagnetic Compatibility Complies with standards and directives: EN 61326-1, industrial sector use; NAMUR NE 21

Mechanical Characteristics

Degree of Protection (IP) IP30
Degree of Protection (IP) Pins IP20
Fire Resistance (UL 94) V0
Housing Material Polyamide
Pitch 17.6 mm (0.69 in)
Width 17.6 mm (0.69 in)
Height 114.5 mm (4.51 in)
Length 108 mm (4.25 in)
Weight 170 g (0.37 lb)

Mounting / Installation

Mounting Type DIN Rail NS35/15, NS35/7.5
Mounting Position Horizontal, Vertical
Connection Type Screw terminal
Solid Conductor Cross-Section Minimum 0.2 mm²
Solid Conductor Cross-Section Maximum 2.5 mm²
Flexible Conductor Cross-Section Minimum 0.2 mm²
Flexible Conductor Cross-Section Maximum 2.5 mm²
AWG Connection Cross-Section 24 ... 14

Accessories

Transparent Cover For ISpac 91xx modules, yellow, transparent. Precise device marking for SIL applications. (Packaging unit: 10 pieces) 200914

Spare Parts

Screw Terminal

3-pole plug, screw connection M3 thread, stripping length: 7 mm, Color: Green 112817
3-pole plug, screw connection M3 thread, stripping length: 7 mm, Color: Black 112816
3-pole plug, screw connection M3 thread, stripping length: 7 mm, Color: Blue 112818

Screw Terminal with Control Tap

3-pole plug with control tap, screw connection M3 thread, stripping length: 7 mm, Color: Black 113005
3-pole plug with control tap, screw connection M3 thread, stripping length: 7 mm, Color: Blue 113004

Spring Clamp Terminal

3-pole plug with control tap, spring clamp terminal Stripping length: 10 mm, Color: Green 112825
3-pole plug with control tap, spring clamp terminal Stripping length: 10 mm, Color: Black 112824
3-pole plug with control tap, spring clamp terminal Stripping length: 10 mm, Color: Blue 112826

PDF preview unavailable. Download the PDF instead.

ex-single-data-sheet-loop-powered-binary-output-ex-i-field-circuit-9176-10-16-00s-222182-fr-fr-rstahl Adobe PDF Library 17.0

Related Documents

Preview R. STAHL 9176A Series: Loop-Powered Binary Output Ex i Field Circuit Isolators
Technical data and specifications for the R. STAHL 9176A series of loop-powered binary output isolators for Ex i field circuits. Details include safety data, electrical characteristics, environmental conditions, mechanical data, and accessories.
Preview R. STAHL 9176/10-16-00s Loop-Powered Binary Output Isolator for Ex i Field Circuits
Technical data sheet for the R. STAHL 9176/10-16-00s loop-powered binary output isolator. This device is designed for the intrinsically safe operation of Ex i solenoid valves, indicator lamps, and horns, requiring no separate auxiliary power supply. It features galvanically separated inputs and outputs, with two-channel variants offering separated channels. The isolator is suitable for various hazardous area classifications including ATEX, IECEx, and cFMus.
Preview R. STAHL 9176 Series Loop-Powered Binary Output Isolator Barriers for Ex i Field Circuits
Technical data and specifications for the R. STAHL 9176 series loop-powered binary output isolator barriers, designed for intrinsically safe operation of Ex i solenoid valves, indicator lamps, and horns in hazardous locations.
Preview R. STAHL 9176A Galvanic Isolator: Ex i Field Circuit Output
Technical specifications and features of the R. STAHL 9176A galvanic isolator, a binary output for Ex i field circuits. Details include safety values, electrical characteristics, environmental conditions, and mechanical specifications.
Preview R. STAHL 9176/10-16-00s: Loop-Powered Binary Output for Ex i Field Circuits
Technical data and specifications for the R. STAHL 9176/10-16-00s loop-powered binary output module, designed for intrinsically safe operation of Ex i solenoid valves, signaling devices, and horns. Features include no separate auxiliary power requirement, galvanic isolation, and various safety certifications.
Preview R. STAHL 9176A Galvanic Isolator: Ex i Field Circuit Output
Technical specifications and features of the R. STAHL 9176A loop-powered binary output Ex i field circuit isolator, including safety, electrical, and mechanical characteristics.
Preview R. STAHL 9176A Galvanic Isolator: Ex i Field Circuit Output
Technical specifications and features of the R. STAHL 9176A loop-powered binary output galvanic isolator for Ex i field circuits. Details on safety, electrical characteristics, environmental conditions, and mechanical specifications.
Preview R. STAHL 9176/20-16-00k Galvanic Isolator: Technical Specifications and Features
Detailed technical specifications, safety features, and electrical characteristics of the R. STAHL 9176/20-16-00k loop-powered binary output Ex i field circuit galvanic isolator. Includes ATEX and IECEx certifications, environmental conditions, and mechanical data.