FSP065-RBBN3 65W AC-DC Adapter
Technical Datasheet
Product Description
This product is a 65-watt AC to DC adapter designed for use in IPC systems, embedded systems, printers, monitors, POS systems, and PoE applications requiring mid-range wattage. The adapter operates from a 90 to 264 VAC input voltage and meets CISPR32 EN55032 CLASS B, EN55024, and FCC PART 15B Class B emission limits, making it suitable for ITE applications.
Features
- Certified to IEC 62368-1 & CB 60950-1 standards
- Peak current function
- Meets Energy Efficiency DOE Level VI
- Meets Code of Conduct Version 5 Tier 2
- High Reliability
- Low Profile design
- Over Current Protection
- Over Temperature Protection
- Over Voltage Protection
- Includes PFC (Power Factor Correction) Circuit
Safety Standard Approvals
The adapter is approved and tested to comply with the following standards:
- UL Listed (I.T.E. POWER SUPPLY)
- TÜV Rheinland Certified
- CE Marked
- FCC Tested to Comply With FCC Standards (For Home or Office Use)
Specifications
Input Specifications
Parameter | Value |
---|---|
Input voltage | 90-264 VAC |
Input frequency | 47-63 Hz |
Input current (full load) | ≤ 1.5A (at 100/240 VAC) |
No load power consumption | ≤ 0.15W (at 115/230 VAC) |
Touch current | ≤ 0.25mA (at 264 VAC / 50Hz) |
Power factor (full load) | ≥ 0.9 (at 115/230 VAC) |
Efficiency | DOE Level VI: 88%; CoC v5 Tier 2: 89% |
Power turn-on time | ≤ 3 Sec (at 100 VAC / full load) |
Hold-up time | ≥ 5 ms (at 100/240 VAC / full load) |
Inrush current | Shall be less than the rating of adapter critical components (at 100/240 VAC / full load) |
Operating altitude | 5000 meters above sea level |
Withstand voltage | 4000V DC (Between AC input and secondary, 1 min test, < 10mA cutoff) |
MTBF (Mean Time Between Failures) | ≥ 300,000 hours (at 100/240 VAC / full load, 25°C) |
Output Specifications
Parameter | Value |
---|---|
Output voltage/current | 19V / 3.42A |
Total output power | 65W |
Over voltage protection | Adapter enters shut down if output exceeds 25V (due to internal fault). Returns to normal state by AC reset. |
Short circuit & Over current protection | Adapter shuts down and enters auto-recovery mode upon detection of internal or external faults. |
Over temperature protection | Adapter enters shut down if abnormal thermal rise occurs. Returns to normal state by AC reset. |
Brown-out protection | Shutdown with no damage. |
Environmental Specifications
Parameter | Value |
---|---|
Working Temperature | 0~70°C (Derating required above 40°C) |
Storage Temperature | -20~+80°C |
Working Humidity | 20~80% RH (non-condensing) |
Storage Humidity | 10~90% RH (non-condensing) |
EMC Performance
Standard/Test | Description |
---|---|
EN55032 | Class B conducted, Class B radiated |
FCC | Class B conducted, Class B radiated |
VCCI | Class B conducted, Class B radiated |
EN61000-4-2 (ESD) | Air discharge: ±15KV, Contact discharge: ±8KV (Criterion A) |
EN61000-4-3 (Radiated Immunity) | 80~1000 MHz, 3V/m, 80% AM (Criterion A) |
EN61000-4-4 (EFT) | Impulse: ±1kV (applied to L, N) (Criterion A) |
EN61000-4-5 (Surge) | ±1kV (differential mode), ±2kV (common mode) (Criterion A) |
EN61000-4-6 (Conducted Immunity) | 0.15~80 MHz, 3Vrms, 80% AM (Criterion A) |
EN61000-4-8 (Magnetic Field) | 50 Hz or 60Hz, 1A/m (Criterion A) |
Voltage Dips | >95% reduction for 0.5 period (Criterion B), 30% reduction for 25 period (Criterion C) |
Voltage Interruptions | >95% reduction for 250 period (Criterion C) |
Power De-rating
Power de-rating is applied based on ambient temperature and load conditions. For example, at 100Vac or 240Vac input:
- 0°C to 40°C: 100% load
- 50°C: 85% load
- 60°C: 70% load
- 70°C: 55% load
The de-rated load must remain within the rating of critical adapter components.
Performance Curves
Input Voltage Derating Curve
The Input Voltage Derating Curve graph indicates that the adapter maintains 100% of its maximum output power across the entire specified input voltage range, from 90 VAC to 264 VAC.
Output Power Derating Curve
The Output Power Derating Curve graph shows the relationship between maximum load percentage and ambient temperature. The adapter can operate at 100% maximum load up to approximately 40°C. Above 40°C, the maximum load capacity is progressively reduced as the temperature increases.
Mechanical Specifications
Approximate dimensions:
- Length: 108.3 mm [4.264 inches]
- Width: 46.3 mm [1.823 inches]
- Height: 30.0 mm [1.181 inches]
Wire specifications: UL1185, 18AWG gauge.
Placeholder labels for D/C, S/N, P/N, and a general LABEL area are indicated on the diagram.
Connector Specifications
The output connector is a DC barrel plug with dimensions 5.5mm outer diameter, 2.5mm inner diameter, and 11mm length. The cable is approximately 1500mm [59.055 inches] long.
Connector Pinout: Positive (+) is White (WHT), Negative (-) is Black (BLK).