FSP180-AxxN3 Series 180W Adapter
Technical Datasheet
Features
- Certified IEC 62368-1 & CB 60950-1
- Meets USA EISA 2007
- Meets Energy Efficiency DOE Level VI
- Meets Code of Conduct Version 5 Tier 2
- High Reliability
- Low Profile
- Over Current Protection
- Over Temperature Protection
- Over Voltage Protection
- With PFC Circuit
Safety Standard Approval
Approvals include TÜV Rheinland, cULus, CE, FCC, and CCC. Tested to comply with FCC Standards for Home or Office Use.
Description
This product is an 180-watt AC to DC adapter designed for applications requiring high wattage, such as IPC systems, embedded systems, printers, monitors, POS systems, and PoE applications. It operates with an input voltage range of 90 to 264 VAC. The unit complies with CISPR32 EN55032 CLASS B, EN55024, and FCC PART 15B Class B emission limits, making it suitable for ITE applications.
Input Specifications
Parameter | Value |
---|---|
Input voltage | 90-264 VAC |
Input frequency | 47-63 Hz |
Input current (100/240Vac, full load) | ≤ 1.2A |
No load power consumption (115/230Vac) | ≤ 0.5W |
Touch current (264Vac / 50Hz) | ≤ 0.25mA |
Power factor (115/230Vac, full load) | ≥ 0.9 |
Harmonic reduction | Provisions for adding harmonic reduction per EN 61000-3-2 must be present. |
Power turn-on time | ≤ 3 seconds (at 100Vac / full load, output voltage regulation) |
Hold-up time | ≥ 10ms (at 100Vac or 240Vac / full load, output voltage regulation) |
Inrush current | Shall be less than the rating of adapter critical components (rectifiers, fuse, surge, current limiting device) at 100Vac, 240Vac / full load. |
Operating altitude | 5000 meters above sea level |
Withstand voltage | 4242V DC between AC input and secondary applied DC, test time 1 minute, cut-off current ≤ 10mA. |
MTBF | ≥ 300,000 hours at 100Vac, 240Vac / full load, 25°C (standard SR332). |
Output Specifications
Parameter | Value |
---|---|
Total output power | 180W |
Over voltage protection | Adapter enters shut down when over voltage occurs due to internal fault. Output trip voltage shall not exceed 19/29/35/66* volts. Returns to normal state by AC reset. |
Short circuit & Over current protection | When an internal fault occurs, or an external fault causes overload or short circuit at the output, the power supply shall shut down and enter auto-recovery mode. |
Over temperature protection | Adapter enters shut down when abnormal thermal rise occurs. Returns to normal state by AC reset. Set at 60Vac~70Vac. |
Brown-out protection | Set at 60Vac~70Vac. |
Environment
Parameter | Value |
---|---|
Working Temperature | 0~70°C (derating required above 40°C) |
Storage Temperature | -20~+80°C |
Working Humidity | 20~80% RH non-condensing |
Storage Humidity | 10~90% RH non-condensing |
Derating Curves
Input Voltage Derating Curve
This graph illustrates the adapter's performance across different input voltages. The output power remains stable across the input voltage range of 90 VAC to 264 VAC.
Output Power Derating Curve
This graph shows how output power is affected by ambient temperature. The adapter operates at 100% of its rated output power up to 40°C. Beyond 40°C, output power is derated, reaching zero at approximately 70°C.
Output Voltage/Current Rating Chart
Model | Output Voltage | Output Current | AC Inlet | Efficiency (DOE Level VI) | Efficiency (CoC V5, Tier 2) | Over Voltage Protection |
---|---|---|---|---|---|---|
FSP180-AHAN3 | 12V | 15A | C14 | ≥88% | ≥89% | 19 Volts |
FSP180-AHBN3 | 12V | 15A | C6 | 29 Volts | ||
FSP180-AJAN3 | 19.5V | 9.23A | C14 | 35 Volts | ||
FSP180-AJBN3 | 19.5V | 9.23A | C6 | 66 Volts | ||
FSP180-AAAN3 | 24V | 7.5A | C14 | 19 Volts | ||
FSP180-AABN3 | 24V | 7.5A | C6 | 29 Volts | ||
FSP180-AWAN3 | 54V | 3.34A | C14 | 35 Volts | ||
FSP180-AWBN3 | 54V | 3.34A | C6 | 66 Volts |
EMC Performance
Standard | Performance |
---|---|
EN55032 | Class B conducted, Class B radiated |
FCC | Class B conducted, Class B radiated |
VCCI | Class B conducted, Class B radiated |
EN61000-3-2 | Meets Class D |
EN61000-3-3 | Meets regulation |
EN61000-4-2 (ESD) | Air discharge: ±15 KV, contact discharge: ±8KV, meets criterion A |
EN61000-4-3 (Radiated Immunity) | 80~1000 MHz, 3V/m, 80% AM(1kHz), meets criterion A |
EN61000-4-4 (EFT) | Impulse: ±1kV applied to L, N, meets criterion A |
EN61000-4-5 (Surge) | ±1kV applied differential mode, ±2kV applied common mode, meets criterion A |
EN61000-4-6 (Conducted Immunity) | 0.15~80 MHz, 3Vrms, 80% AM(1kHz), meets criterion A |
EN61000-4-8 (Magnetic Field) | 50 Hz or 60Hz, 1A/m, meets criterion A |
EN61000-4-11 (Voltage Dips/Interruptions) | Voltage Dips: >95% reduction for 0.5 period, meets criterion B; 30% reduction for 25 period, meets criterion C. Voltage Interruptions: >95% reduction for 250 period, meets criterion C. |
Power De-rating
Applies to 100Vac or 240Vac input, 0°C to 40°C ambient temperature. The adapter operates at 100% load from 0-40°C. Beyond 40°C, derating is applied: 85% load at 50°C, 70% load at 60°C, and 55% load at 70°C. This derating must be less than the rating of the adapter's critical components, following FSP specifications.
Mechanical Specifications
Detailed dimensions and connector types are provided for various models.
FSP180-AxAN3 / FSP180-AxBN3 Series
General Dimensions: Length: 151.3±0.5 mm, Width: 75.6±0.5 mm, Height: 40.0 mm.
AC Input Connector: Type is a 4-pin power molding with nickel plating or equivalent.
DC Output Cable: Length approximately 1800±50 mm. Features a cable tie made of steel wire, PE plated.
FSP180-AHAN3 Model Specifics
Dimensions: Length: 177±0.5 mm, Width: 85.6±0.5 mm, Height: 32.2±0.5 mm.
DC Output Cable: Length approximately 1500±50 mm (UL11352, #14 AWG). Features a cable tie made of steel wire, PE plated.
Connector Specifications (FSP180-AHAN3)
The DC output connector is a 4-pin power molding. The pin assignments are:
- P1: VO(+) (RED wire)
- P2: (WHITE wire)
- P3: (WHITE wire)
- P4: GND(-) (BLACK wire)
- Shield: (BLACK wire)
Details include heat-shrink tubing (H.S. TUBE) for positive and negative connections.
Notes
*Volts express by order of 120-AHxN3/ ABxN3/ AAxN3 / AFxN3/ AWxN3