FSP180-AxxN3 Series 180W Adapter

Technical Datasheet

Features

Safety Standard Approval

Approvals include TÜV Rheinland, cULus, CE, FCC, and CCC. Tested to comply with FCC Standards for Home or Office Use.

Description

This product is an 180-watt AC to DC adapter designed for applications requiring high wattage, such as IPC systems, embedded systems, printers, monitors, POS systems, and PoE applications. It operates with an input voltage range of 90 to 264 VAC. The unit complies with CISPR32 EN55032 CLASS B, EN55024, and FCC PART 15B Class B emission limits, making it suitable for ITE applications.

Input Specifications

ParameterValue
Input voltage90-264 VAC
Input frequency47-63 Hz
Input current (100/240Vac, full load)≤ 1.2A
No load power consumption (115/230Vac)≤ 0.5W
Touch current (264Vac / 50Hz)≤ 0.25mA
Power factor (115/230Vac, full load)≥ 0.9
Harmonic reductionProvisions for adding harmonic reduction per EN 61000-3-2 must be present.
Power turn-on time≤ 3 seconds (at 100Vac / full load, output voltage regulation)
Hold-up time≥ 10ms (at 100Vac or 240Vac / full load, output voltage regulation)
Inrush currentShall be less than the rating of adapter critical components (rectifiers, fuse, surge, current limiting device) at 100Vac, 240Vac / full load.
Operating altitude5000 meters above sea level
Withstand voltage4242V DC between AC input and secondary applied DC, test time 1 minute, cut-off current ≤ 10mA.
MTBF≥ 300,000 hours at 100Vac, 240Vac / full load, 25°C (standard SR332).

Output Specifications

ParameterValue
Total output power180W
Over voltage protectionAdapter enters shut down when over voltage occurs due to internal fault. Output trip voltage shall not exceed 19/29/35/66* volts. Returns to normal state by AC reset.
Short circuit & Over current protectionWhen an internal fault occurs, or an external fault causes overload or short circuit at the output, the power supply shall shut down and enter auto-recovery mode.
Over temperature protectionAdapter enters shut down when abnormal thermal rise occurs. Returns to normal state by AC reset. Set at 60Vac~70Vac.
Brown-out protectionSet at 60Vac~70Vac.

Environment

ParameterValue
Working Temperature0~70°C (derating required above 40°C)
Storage Temperature-20~+80°C
Working Humidity20~80% RH non-condensing
Storage Humidity10~90% RH non-condensing

Derating Curves

Input Voltage Derating Curve

This graph illustrates the adapter's performance across different input voltages. The output power remains stable across the input voltage range of 90 VAC to 264 VAC.

Output Power Derating Curve

This graph shows how output power is affected by ambient temperature. The adapter operates at 100% of its rated output power up to 40°C. Beyond 40°C, output power is derated, reaching zero at approximately 70°C.

Output Voltage/Current Rating Chart

ModelOutput VoltageOutput CurrentAC InletEfficiency (DOE Level VI)Efficiency (CoC V5, Tier 2)Over Voltage Protection
FSP180-AHAN312V15AC14≥88%≥89%19 Volts
FSP180-AHBN312V15AC629 Volts
FSP180-AJAN319.5V9.23AC1435 Volts
FSP180-AJBN319.5V9.23AC666 Volts
FSP180-AAAN324V7.5AC1419 Volts
FSP180-AABN324V7.5AC629 Volts
FSP180-AWAN354V3.34AC1435 Volts
FSP180-AWBN354V3.34AC666 Volts

EMC Performance

StandardPerformance
EN55032Class B conducted, Class B radiated
FCCClass B conducted, Class B radiated
VCCIClass B conducted, Class B radiated
EN61000-3-2Meets Class D
EN61000-3-3Meets regulation
EN61000-4-2 (ESD)Air discharge: ±15 KV, contact discharge: ±8KV, meets criterion A
EN61000-4-3 (Radiated Immunity)80~1000 MHz, 3V/m, 80% AM(1kHz), meets criterion A
EN61000-4-4 (EFT)Impulse: ±1kV applied to L, N, meets criterion A
EN61000-4-5 (Surge)±1kV applied differential mode, ±2kV applied common mode, meets criterion A
EN61000-4-6 (Conducted Immunity)0.15~80 MHz, 3Vrms, 80% AM(1kHz), meets criterion A
EN61000-4-8 (Magnetic Field)50 Hz or 60Hz, 1A/m, meets criterion A
EN61000-4-11 (Voltage Dips/Interruptions)Voltage Dips: >95% reduction for 0.5 period, meets criterion B; 30% reduction for 25 period, meets criterion C. Voltage Interruptions: >95% reduction for 250 period, meets criterion C.

Power De-rating

Applies to 100Vac or 240Vac input, 0°C to 40°C ambient temperature. The adapter operates at 100% load from 0-40°C. Beyond 40°C, derating is applied: 85% load at 50°C, 70% load at 60°C, and 55% load at 70°C. This derating must be less than the rating of the adapter's critical components, following FSP specifications.

Mechanical Specifications

Detailed dimensions and connector types are provided for various models.

FSP180-AxAN3 / FSP180-AxBN3 Series

General Dimensions: Length: 151.3±0.5 mm, Width: 75.6±0.5 mm, Height: 40.0 mm.

AC Input Connector: Type is a 4-pin power molding with nickel plating or equivalent.

DC Output Cable: Length approximately 1800±50 mm. Features a cable tie made of steel wire, PE plated.

FSP180-AHAN3 Model Specifics

Dimensions: Length: 177±0.5 mm, Width: 85.6±0.5 mm, Height: 32.2±0.5 mm.

DC Output Cable: Length approximately 1500±50 mm (UL11352, #14 AWG). Features a cable tie made of steel wire, PE plated.

Connector Specifications (FSP180-AHAN3)

The DC output connector is a 4-pin power molding. The pin assignments are:

Details include heat-shrink tubing (H.S. TUBE) for positive and negative connections.

Notes

*Volts express by order of 120-AHxN3/ ABxN3/ AAxN3 / AFxN3/ AWxN3

PDF preview unavailable. Download the PDF instead.

FSP180-AAAN3 datasheet Neevia Converter Pro v7.2.0.131 (http://neevia.com)

Related Documents

Preview FSP180-AxxN3 Series 180W AC-DC Adapter Datasheet | FSP
FSP180-AxxN3 Series 180W AC-DC Adapter Datasheet: Comprehensive technical specifications, features, safety approvals, and mechanical details for FSP's high-wattage power supply, suitable for IPC, embedded systems, and industrial applications. Includes efficiency ratings, protection features, and compliance information.
Preview FSP180-AxxN3 Series 180W AC to DC Adapter Datasheet
Technical datasheet for the FSP180-AxxN3 Series 180W AC to DC adapter, detailing features, specifications, safety approvals, and mechanical dimensions for industrial and embedded applications.
Preview FSP180-AxxN3 Series 180W AC-DC Adapter Datasheet | FSP
Technical datasheet for the FSP180-AxxN3 Series 180W AC-DC adapter. Features include IEC 62368-1 certification, DOE Level VI efficiency, and over-voltage/current protection. Specifications, performance curves, and mechanical details.
Preview FSP180-AxxN3 Series 180W AC-DC Power Adapter Datasheet
Technical datasheet for the FSP180-AxxN3 Series 180W AC-DC power adapter, detailing features, specifications, safety approvals, and mechanical dimensions for industrial and embedded systems.
Preview FSP Switching Power Adapter CB Test Certificate | IEC IECEE Compliance
CB Test Certificate for FSP Switching Power Adapters, detailing compliance with IEC 62368-1. Includes product specifications, model numbers, and factory information.
Preview FSP Switching Power Adapter CB Test Certificate
Official CB Test Certificate issued by TÜV Rheinland for FSP Group Inc. switching power adapters, confirming conformity with IEC 62368-1:2018. Includes model numbers and technical specifications.
Preview FSP Switching Power Adapter CB Test Certificate - Models FSP180-ABAN3 Series
Official CB Test Certificate for FSP Switching Power Adapters, including models FSP180-ABAN3, FSP180-ABBN3, FSP180-AJAN3, FSP180-AJBN3, FSP180-ACAN3, FSP180-ACBN3, FSP180-AAAN3, FSP180-AABN3, FSP180-AWAN3, FSP180-AWBN3, certified under IEC 62368-1.
Preview FSP Switching Power Adapter CB Test Certificate
Official CB Test Certificate issued by TÜV Rheinland Japan Ltd. for FSP Group Inc. Switching Power Adapters. This document confirms compliance with IEC 62368-1:2018 for models including FSP180-ABAN3, FSP180-ABBN3, FSP180-AJAN3, FSP180-AJBN3, FSP180-ACAN3, FSP180-ACBN3, FSP180-AAAN3, FSP180-AABN3, FSP180-AWAN3, and FSP180-AWBN3. Details include input/output ratings and multiple manufacturing locations.