FSP045-RXXN3 Series: 45W AC to DC Adapter
Technical Datasheet
Features
- Certified IEC 62368-1 & CB 60950-1
- Peak current function
- Meets Energy Efficiency DOE Level VI
- Meets Code of Conduct Version 5 Tier 2
- High Reliability
- Low Profile
- Over Current Protection
- Over Temperature Protection
- Over Voltage Protection
- With PFC Circuit
Safety Standard Approval
Approvals include CULUS LISTED I.T.E. POWER SUPPLY (E190414), TÜVRheinland ZERTIFIZIERT, CE, and FCC compliance for home or office use.
Description
This product is a 45-watt AC to DC adapter designed for use in IPC systems, embedded systems, printers, monitors, charging systems, and POS systems requiring high wattage demands. It operates at a 90 to 264 VAC input voltage. The unit meets CISPR32 EN55032 CLASS B, EN55024, and FCC PART 15B Class B emission limits and is designed for ITE applications.
Input Specifications
Electrical
- Input voltage: 90-264 VAC
- Input frequency: 47-63 Hz
- Input current: ≤ 1.5A at 100Vac/240Vac full load
- No load power consumption: ≤ 0.075W at 115Vac/230Vac
- Touch current: ≤ 0.25mA at 264Vac/50Hz
Performance
- Power factor: N/A
- Efficiency: See rating chart
- Power turn-on time: Shall remain regulation ≤ 3Sec at 100Vac/full load
- Hold-up time: Shall remain regulation ≥ 5ms at 100Vac or 240Vac/full load
- Inrush current: Shall be less than the rating of adapter critical components (rectifiers, fuse, surge, current limiting device) at 100Vac/240Vac/full load
- Operating altitude: 5000 meters above sea level
- Withstand voltage: 4000V DC between AC input and secondary (1 minute, cut off current < 10mA)
- MTBF: 300,000 hours at 25°C, 100Vac/240Vac/full load (standard SR332)
Output Specifications
- Output voltage/current: See rating chart
- Total output power: See rating chart
- Protection:
- Over voltage: Adapter enters shut down if output terminal voltage exceeds normal due to internal fault. Output trip voltage shall not exceed 28.5V. Returns to normal state by AC reset.
- Short circuit & Over current: Power supply shuts down and enters auto-recovery mode upon internal or external fault at the output.
- Over temperature: Adapter enters shut down upon abnormal thermal rise. Returns to normal state by AC reset.
- Brown-out: Shutdown and no damage.
EMC Performance
- EN55032: Class B conducted, Class B radiated
- FCC: Class B conducted, Class B radiated
- VCCI: Class B conducted, Class B radiated
- EN61000-3-2: N/A (<75W)
- EN61000-3-3: Meets regulation
- EN61000-4-2 (ESD): Air discharge: ±15 KV, contact discharge: ±8KV (meets criterion A)
- EN61000-4-3 (RS): 80-1000 MHz, 3V/m, 80% AM (1kHz) (meets criterion A)
- EN61000-4-4 (EFT): Impulse: ±1kV applied to L,N (meets criterion A)
- EN61000-4-5 (Surge): ±1kV applied differential mode, ±2kV applied common mode (meets criterion A)
- EN61000-4-6 (CS): 0.15-80 MHz, 3Vrms, 80% AM (1kHz) (meets criterion A)
- EN61000-4-8 (MS): 50 Hz or 60Hz, 1A/m (meets criterion A)
- EN61000-4-11 (Flicker/FDIS):
- Voltage Dips: >95% reduction for 0.5 period (meets criterion A)
- Voltage Dips: 30% reduction for 25 period (meets criterion B)
- Voltage Interruptions: >95% reduction for 250 period (meets criterion B)
Power De-rating
De-rating applies for temperatures above 40°C. At 100Vac or 240Vac, the load is 100% at 0-40°C, 80% at 50°C, 60% at 60°C, and 50% at 70°C. De-rating should be less than the rating of adapter critical components, following FSP specifications.
Environment
- Working TEMP.: 0~70°C (de-rating above 40°C)
- Storage TEMP.: -20~+80°C
- Working Humidity: 20~80% RH (non-condensing)
- Storage Humidity: 10~90% RH (non-condensing)
Performance Curves
Input Voltage Derating Curve
A line graph showing the relationship between input voltage (Vac) on the x-axis (ranging from 90 to 264) and output power (% of maximum) on the y-axis (ranging from 0 to 100). The curve indicates that output power remains at 100% across the typical input voltage range.
Output Power Derating Curve
A line graph showing the relationship between ambient temperature (°C) on the x-axis (ranging from 0 to 70) and output power (% of maximum load) on the y-axis (ranging from 0 to 100). The curve shows a gradual decrease in maximum load capacity as temperature increases, starting to de-rate significantly after 40°C.
Output Voltage/Current Rating Chart
Model | Output Voltage | Output Current | AC Inlet | Efficiency (DOE Level VI) | Efficiency (CoC V5 Tier 2) |
---|---|---|---|---|---|
FSP045-RBBN3 | 19V | 2.37A | C6 | 87.73% | 88.97% |
FSP045-RBCN3 | 19V | 2.37A | C8 | 87.73% | 88.97% |
FSP045-RABN3 | 24V | 1.87A | C6 | 87.73% | 88.97% |
FSP045-RACN3 | 24V | 1.87A | C8 | 87.73% | 88.97% |
Mechanical Specifications
The adapter is available in two main physical configurations, corresponding to different AC inlet types (C6, C8) and output connector types.
FSP045-RACN3 & FSP045-RBCN3 Series
Adapter Body Dimensions: Approximately 108.3mm (length) x 46.3mm (width) x 30.0mm (height).
Cable: Features UL1185 20AWG wire, with a total length of 1200±30mm. Includes a cable tie.
Output Connector: A barrel type connector, specified as 5.5*2.5*9.5mm, with a "tuning fork groove" design. The ground wire heat shrink tube extends 4.5mm into the SR (Strain Relief) component.
FSP045-RABN3 & FSP045-RBBN3 Series
Adapter Body Dimensions: Similar to the above, approximately 108.3mm (length) x 46.3mm (width) x 30.0mm (height).
Cable: Features UL1185 20AWG wire, with a total length of 1200±30mm. Includes a cable tie.
Output Connector: A barrel type connector, specified as 5.5*2.5*9.5mm, with a "tuning fork groove" design. The ground wire heat shrink tube extends 4.5mm into the SR (Strain Relief) component.
Connector Specifications
Detailed views of the connector and cable assembly are provided. The output connector is a standard barrel type with specific dimensions (5.5*2.5*9.5mm) and a unique "tuning fork groove" design. The cable is 20AWG (UL1185) and approximately 1.2 meters long. Wire color coding is indicated: Black for negative (-), White for positive (+). The ground wire is secured with a heat shrink tube.