FSP018(24)-DHXN3 Series
18W / 24W 12V AC to DC Adapter
Features
- USA, Europe, UK, Australia, China plug ready
- Meets IEC 62368-1 & IEC 60950-1
- Meets Energy Efficiency DOE Level VI
- Meets Code of Conduct Version 5 Tier 2
- High Reliability
- EMC Standard: EN55032/ EN55024 Class B
- Over Current Protection
- Over Voltage Protection
Safety Standard Approvals
- CULUS LISTED E190414
- TÜVRheinland Certified Safety
- AFC Tested to Comply With FCC Standards
- FOR HOME OR OFFICE USE
Description
This product is an 18-24 watt fixed plug AC to DC adapter designed for consumer electronic systems with small wattage demands. It operates at 90 to 264 VAC input voltage. The unit meets CISPR32 EN55032 CLASS B, EN55024, and FCC PART 15B Class B emission limits, and is intended for ITE (Information Technology Equipment) applications.
Input Specifications
Parameter | Value |
---|---|
Input voltage | 90-264 VAC |
Input frequency | 47-63 Hz |
Input current | 100Vac, 240Vac / full load ≤ 0.65A |
No load power consumption | 115Vac, 230Vac ≤ 0.075W |
Touch current | 264Vac / 50Hz ≤ 0.25mA |
Output Specifications
Parameter | Details |
---|---|
Output voltage/current | See rating chart |
Total output power | See rating chart |
Protection: Over voltage | The adapter will enter shut down with no output if over voltage occurs at the output terminal due to an internal fault. The output trip voltage shall not exceed 16V. Normal operation will resume after an AC reset. |
Protection: Short circuit & Over current | When an internal fault occurs, or an external fault is applied to the output, the power supply shall shut down and enter auto-recovery mode. |
Environment
Parameter | Value |
---|---|
Working Temperature | 0~70°C (derating required above 40°C) |
Storage Temperature | -20~+80°C |
Working Humidity | 20~80% RH non-condensing |
Storage Humidity | 10~90% RH non-condensing |
Input Specifications (Continued)
Parameter | Value |
---|---|
Power factor | N/A |
Efficiency | See rating chart. |
Power turn-on time | At 115Vac / full load, output voltage shall remain regulation ≤ 3 seconds. |
Hold-up time | At 115Vac or 230Vac / full load, output voltage shall remain regulation ≥ 10ms. |
Inrush current | At 115Vac, 230Vac / full load, shall be less than the rating of the adapter's critical component (including rectifiers, fuse surge, and current limiting device). |
Operating altitude | 5000 meters above sea level. |
Withstand voltage | Between AC input and secondary applied DC: 4242V, test time 1 minute, cut-off current shall be less than 10mA. |
MTBF | 230Vac / full load, 300,000 hours at 25°C, standard SR332. |
EMC Performance
Standard | Performance |
---|---|
EN55032 | Class B conducted, Class B radiated |
FCC | Class B conducted, Class B radiated |
VCCI | Class B conducted, Class B radiated |
EN61000-3-2 | Meets Class D |
EN61000-3-3 | Meets regulation |
EN61000-4-2 | Air discharge: ±8 KV, contact discharge: ±4KV, meets criterion A. |
EN61000-4-3 | 80-1000 MHz, 3V/m, 80% AM (1kHz), meets criterion A. |
EN61000-4-4 | Impulse: ±1kV applied to L,N, meets criterion A. |
EN61000-4-5 | ±1kV applied differential mode, ±2kV applied common mode, meets criterion A. |
EN61000-4-6 | 0.15-80 MHz, 3Vrms, 80% AM (1kHz), meets criterion A. |
EN61000-4-8 | 50 Hz or 60Hz, 1A/m, meets criterion A. |
EN61000-4-11 | Voltage Dips: >95% reduction for 0.5 period, meets criterion B; 30% reduction for 25 period, meets criterion C. Voltage Interruptions: >95% reduction for 250 period, meets criterion C. |
Power De-rating
For 100Vac or 240Vac input:
- 0°C to 40°C: 100% load
- 50°C: 85% load
- 60°C: 70% load
- 70°C: 55% load
De-rating shall be less than the rating of the adapter's critical component, following FSP specifications.
Performance Curves
Input Voltage Derating Curve
This curve illustrates the output power percentage relative to input voltage. The adapter maintains stable output power across the input voltage range of 90 VAC to 264 VAC.
Output Power Derating Curve
This curve shows the output power percentage relative to ambient temperature. The adapter operates at full capacity up to 40°C. Above 40°C, output power is derated, reaching approximately 55% of maximum load at 70°C.
Output Voltage/Current Rating Chart
Model | Output Voltage | Output Current | AC Inlet | Efficiency (DOE Level VI) | Efficiency (CoC V5 Tier 2) |
---|---|---|---|---|---|
FSP018-DHXN3 | 12V | 1.5A | C14 | ≥85% | ≥85.45% |
FSP024-DHXN3 | 12V | 2A | C14 | ≥86.2% | ≥86.8% |
Mechanical Specifications
Detailed dimensions and connector specifications are provided for the adapter units. Key dimensions include overall case size and cable length. The DC output connector typically features a 5.5 mm outer diameter and a 2.5 mm inner diameter. Cables are 24 AWG and meet VW-1 flame retardant standards. The units are housed in black cases.
General Dimensions (Example for one model type):
- Overall Length (including cable): Approximately 1500 mm ± 20 mm
- Cable Length (from case to connector): Approximately 970 mm ± 30 mm
- Case Dimensions (approximate): 77.0 mm (L) x 44.8 mm (W) x 34.0 mm (H)
- DC Output Connector Outer Diameter: 5.5 mm ± 0.05 mm
- DC Output Connector Inner Diameter: 2.5 mm ± 0.1 mm
Cable Specifications:
- Wire Gauge: 24 AWG
- Wire Type: 2468
- Flame Retardant Rating: VW-1
- Cable Tie: PET Plated
Labeling: Includes P/N, S/N, D/C information.
Case Color: Black.