Features
- Meets IEC 62368-1 & IEC 60950-1 standards
- Meets Energy Efficiency DOE Level VI
- Meets Code of Conduct Version 5 Tier 2
- High Reliability
- EMC Standard: EN55032/ EN55024 Class B
- Over Current Protection
- Over Temperature Protection
- Over Voltage Protection
Safety Standard Approvals
Approvals include CULUS LISTED (E190414), TÜV Rheinland Certified, and compliance with FCC Standards for Home or Office Use.
Description
This product is a 65-watt AC to DC adapter designed for use in IPC Systems, Communication Systems, Embedded Systems, and PoE Systems. It operates at an input voltage range of 90 to 264 VAC. The unit meets CISPR32 EN55032 CLASS B, EN55024, and FCC PART 15B Class B emission limits, and is designed for Information Technology Equipment (ITE) applications.
Input Specifications
Parameter | Value |
---|---|
Input voltage | 90-264 VAC |
Input frequency | 47-63 Hz |
Input current | 100Vac, 240Vac / full load ≤ 1.8A |
No load power consumption | 115Vac, 230Vac ≤ 0.15W |
Touch current | 264Vac / 50Hz ≤ 0.25mA |
Output Specifications
Parameter | Description |
---|---|
Total output power | 65W |
Over voltage protection | The adapter enters shut down mode if output voltage exceeds 63V. Returns to normal state by AC reset. |
Short circuit & Over current protection | The power supply shuts down and enters auto-recovery mode upon internal or external fault. |
Over temperature protection | The power supply enters shut down mode during abnormal thermal rise. Returns to normal state by AC reset. |
Brown-out protection | Set at 65Vac~75Vac |
Environment - Working Temperature | 0~70°C (derating above 40°C) |
Environment - Storage Temperature | -20~+80°C |
Environment - Working Humidity | 20~80% RH non-condensing |
Environment - Storage Humidity | 10~90% RH non-condensing |
Performance Characteristics
Input Voltage Derating Curve
The Input Voltage Derating Curve indicates that the output power capacity remains at 100% across the entire input voltage range from 90 VAC to 264 VAC.
Output Power Derating Curve
The Output Power Derating Curve shows that the maximum load capacity decreases as the ambient temperature increases. It is 100% at 0°C and reduces to approximately 55% at 70°C.
Output Voltage/Current Rating Chart
Model | Output Voltage | Output Current | AC Inlet | Efficiency (DOE Level VI) | Efficiency (CoC V5 Tier 2) |
---|---|---|---|---|---|
FSP065-DWAN3 | 54V | 1.2A | C14 | ≥88% | ≥89% |
FSP065-DFAN3 | 48V | 1.36A | C14 | ≥88% | ≥89% |
Other Specifications
Parameter | Value |
---|---|
Efficiency (Power turn-on time) | At 100Vac / full load, output voltage shall remain regulation ≤ 3Sec |
Hold-up time | At 100Vac or 240Vac / full load, output voltage shall remain regulation ≥8ms |
Inrush current | 100Vac, 240Vac / full load: Shall be less than the rating of adapter critical component (including rectifiers, fuse surge and current limiting device) |
Operating altitude | 5000 meters above sea level |
Withstand voltage | Between AC input and secondary applied DC: 4242V, test time 1 minute, cut off current shall be less than 10mA |
MTBF | 100Vac, 240Vac / full load: 300,000 hours at 25°C, standard SR332 |
EMC Performance | EN55032: Class B conducted, Class B radiated FCC: Class B conducted, Class B radiated VCCI: Class B conducted, Class B radiated EN61000-3-3: Meet regulation EN61000-4-2: Air discharge: ±8 KV, contact discharge: ±4KV, meet criterion A EN61000-4-3: 80~1000 MHz, 3V/m, 80% AM(1kHz), meet criterion A EN61000-4-4: Impulse: ±1kV applied to L,N, meet criterion A EN61000-4-5: ±1kV applied differential mode, ±2kV applied common mode, meet criterion A EN61000-4-6: 0.15~80 MHz, 3Vrms, 80% AM(1kHz), meet criterion A EN61000-4-8: 50 Hz or 60Hz, 1A/m, meet criterion A EN61000-4-11 (Voltage Dips): >95% reduction for 0.5 period, meet criterion B EN61000-4-11 (Voltage Interruptions): >95% reduction for 250 period, meet criterion C |
Power de-rating | Applies to 100Vac or 240Vac input: 0°C-40°C (100% load), 50°C (85% load), 60°C (70% load), 70°C (55% load). Shall be less than the rating of adapter critical component, follow FSP specification. |
Mechanical Specifications
Overall Dimensions: The adapter unit measures approximately 97.0 mm (length) ± 30 mm, 32.8 mm (width) ± 0.5 mm, and 21.8 mm (height) ± 0.5 mm. The output cable is approximately 1200.0 mm (length) ± 20.0 mm, with a wire gauge of 24AWG and black color, featuring a PET plated cable tie.
Connector Specifications: The output connector is a circular type with a diameter of 5.5 mm ± 0.05 mm. Pin 'a' is designated as positive (+) and pin 'b' as negative (-). Detailed pin housing and wire termination measurements are provided in the original diagrams.