COLDZONE
A2L R-SERIES NEXT-GEN MINICON
1/2 to 6 HP Air Cooled Condensing Units
The Next-Gen MiniCon R-Series units, ranging from 1/2 to 6 HP, are engineered for increased efficiency, enhanced features, improved serviceability, and a wider selection of cataloged options. These units are well-suited for various commercial applications, including cafeterias, convenience stores, restaurants, and fast food outlets, offering versatility for numerous other applications. Constructed from high-quality materials, they provide increased flexibility and significantly improve efficiency, leading to lower long-term operating costs. The compact product line is designed to utilize refrigerants R454A, R454C, and R455A. Available with scroll compressors, the standard Next-Gen R-Series is rated for operation in ambient air temperatures up to 110° F.
Integral Sub-Cooling Circuit
All Next-Gen MiniCon units feature an integral sub-cooling circuit. This design allows saturated liquid refrigerant to flow from the receiver to the condenser, where it is sub-cooled by ambient air. This process provides an average of 3 to 5° F of sub-cooling, which enhances efficiency and ensures optimal expansion device operation.
The sub-cooling circuit involves the flow of saturated liquid from the receiver to the condenser coil, where it is cooled by ambient air. The resulting subcooled liquid then proceeds to the expansion valve.
Features and Options
The following table details the features and options available for the Next-Gen MiniCon units, indicating whether they are Standard, Optional, or Not Available for Medium & Low Temperature configurations.
DESCRIPTION | MEDIUM & LOW TEMPERATURE |
---|---|
Scroll Compressors | ● |
Generously Sized High Efficiency Condenser, Enhanced Copper Tubes/Aluminum Fins | ● |
Suction Line Piping | ● |
Larger Electrical Panel With Hinged/Removable Door | ● |
Crankcase Heater | ● |
Fixed High/Adjustable Low-Pressure Control | ● |
Liquid Line With Components: Sealed Filter & Sight Glass | ● |
All-Weather Galvanized Steel Painted Housing | ● |
Refrigerant Receiver With Isolation Valve And Pressure Relief Plug | ● |
Integral Liquid Sub-Cooling Circuit | ● |
Quick Access Shut Off Valves | ● |
Easy Access Control Panel Door | ● |
Color-Coded/Numbered Point-To-Point Wiring | ● |
Flooded Head Pressure Control | Flooded Models ● |
Pressure Fan Cycle Control | Non-Flooded Models ● |
EC Fan Motors | ● |
Dual Pressure Control | ● |
Adjustable Head Pressure Control Valve | FM1 - FM3 ● |
Liquid Line Without Components: Pipe Only | FM4 Cabinet ● |
Liquid Line With Premium Components: Replaceable Core Filter/Drier & Sight Glass | ● |
Suction Line Components: Sealed Filter | FM4 Cabinet ● |
Suction Line Components: Replaceable Core Filter | ● |
Suction Line Accumulator | ● |
Additional compressor cooling (Medium Temp): Dual pressure control, insulated suction line components and piping, liquid injection, and suction accumulator. | ● |
Additional compressor cooling (Low Temp): Dual pressure control, insulated suction line components and piping. | ● |
Oil Separator | FM4 Cabinet ● |
Oversized Receiver | ● |
Pump-Down Toggle Switch | ● |
Heated & Insulated Receiver | ● |
Phase Loss Monitor | ● |
Single Point Power | ● |
Thru-The-Door Non-Fused Disconnect Switch | ● |
Copper Fins Or Electro Fin/Bronze Glow Coated Coil | ● |
316 Stainless Steel Cabinet | ● |
^ See dimensional drawings on pages 23-26.
Factory Installed Options // Common Defrost Components
The following table outlines factory-installed options for defrost components, indicating availability for Medium and Low Temperature models.
DESCRIPTION | MEDIUM TEMPERATURE | LOW TEMPERATURE |
---|---|---|
Electronic Air Defrost Timer | ● | ● |
Mechanical Air Defrost Timer | ● | ● |
Defrost Kit | ● | ● |
* See Electrical Data Tables on pages 12-13 for Low Temperature Standard Defrost Kits and Medium Temperature Most Common Defrost Kits detail. Consult Price Book for complete offering of Defrost Kit Options and Standard Defrost Component Deductions.
Shipped Loose Accessories
The following accessories are available for separate purchase and installation:
DESCRIPTION | MEDIUM & LOW TEMPERATURE |
---|---|
External Fused Disconnect | ● |
Snow/Hail Guards | ● |
Snow Legs | ● |
Crankcase Pressure Regulating Valve | ● |
Two-Tiered Stacking Rack | ● |
Visuals highlight key design features for ease of use and maintenance:
- Easy access/removable control panel door for convenient maintenance.
- Color-coded & numbered point-to-point wiring for simplified troubleshooting.
- Quick access to shut-off valves located on the cabinet exterior.
- Optional replaceable core liquid and suction filters available for FM4 flooded and non-flooded models.
Model Nomenclature
The model nomenclature system allows for configuration of the condensing units. The base model is structured as follows:
C | F | O | N | 150 | E | 4A | D | A | NT |
---|---|---|---|---|---|---|---|---|---|
Brand | Style | Compressor Style | Compressor Configuration | Horsepower | Temperature Range | Refrigerant | Voltage | Vintage | Pre-Config. Codes |
C - Coldzone | F - Flooded | O - Scroll | N - Single Horizontal (small) | 150 = 1.5 HP | E - Extended Medium | 4A - R454A, R454C, or R455A | D - 208-230/1/60 | A | NT - No Defrost Timer/Kit |
B - Non-Flooded | L - Low | E - 208-230/3/60 | |||||||
M - Medium | G - 460/3/60 | ||||||||
M - 200-220/1/50¹ | |||||||||
N - 200-220/3/50¹ | |||||||||
Q - 380/3/50¹ |
¹ 50 Hz available. See electrical tables for specific model availability or contact factory for additional information.
² Pre-Configuration Codes are used to show common factory mounted options. Pre-Configuration Codes are not available for every model. For specific model availability, see the respective Pre-Configuration pricing tables in the current Price Book or contact your local Coldzone sales representative.
³ "NT" Pre-Configuration Code is available on Flooded Models with 208-230/1/60 or 208-230/3/60 voltage.
Capacity Data (BTUH)
Extensive capacity data tables are provided for various refrigerants (R454A, R454C, R455A) across different ambient and suction temperatures for both Medium/Extended Medium and Low Temperature models. These tables detail performance metrics for a wide range of configurations, including specific model numbers, compressor model numbers, and corresponding BTUH outputs under varying conditions.
Additional Compressor Cooling
Graphs illustrate the conditions under which additional compressor cooling is recommended.
Medium Temperature Models
A graph plots Ambient Temperature against Suction Temperature, showing distinct lines for R454A, R454C, and R455A refrigerants. The text "Additional compressor cooling is recommended for ambients above the lines shown." advises users on optimal operating parameters. This option typically includes dual pressure control, insulated suction line components and piping, liquid injection (TREV), and a suction accumulator.
Low Temperature Models
A similar graph for Low Temperature models displays Ambient Temperature versus Suction Temperature for R454A, R454C, and R455A refrigerants. The recommendation "Additional compressor cooling is recommended for ambients above the lines shown." applies here as well. This option typically includes dual pressure control and insulated suction line components and piping.
Electrical Data
Detailed electrical data tables are presented for various voltage configurations (208-230V/1/60 HZ, 200-220V/1/50 HZ, 208-230V/3/60 HZ, 200-220V/3/50 HZ, 460V/3/60 HZ, 380V/3/50 HZ) and refrigerants. These tables include compressor RLA, LRA, Condenser Fan FLA, MCA, MOPD, Evaporator Fan Amps, and Defrost Amps, along with electric defrost kit information. Key definitions such as RLA (Rated Load Amps), LRA (Locked Rotor Amps), MCA (Minimum Circuit Ampacity), and MOPD (Maximum Overcurrent Protection) are provided.
Specifications
Comprehensive specifications are provided for all models, categorized by temperature range.
Medium/Extended Medium Temperature Scroll
Model No. | Comp. Model No. | HP | Connections (In.) Liquid |
Connections (In.) Suction |
Pump Down Capacity (lbs) 90% R454A |
Pump Down Capacity (lbs) 90% R454C |
Pump Down Capacity (lbs) 90% R455A |
Pump Down Capacity (lbs) Oversized Receiver 90% R454A |
Pump Down Capacity (lbs) Oversized Receiver 90% R454C |
Pump Down Capacity (lbs) Oversized Receiver 90% R455A |
Cabinet Size | Fan Qty | Dimensions (In.) D | Dimensions (In.) W | Dimensions (In.) H | Approx. Ship Wt. (Lbs) | Sound dBA |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C*ON060M4A** | YB06KAE | 1/2 | 3/8 | 5/8 | 10.8 | 11 | 10.9 | 13.3 | 13.6 | 13.5 | FM1 | 1 | 28-1/4 | 27-7/8 | 18-3/4 | 195 | 70 |
C*ON080M4A** | YB07KAE | 3/4 | 3/8 | 5/8 | 10.8 | 11 | 10.9 | 13.3 | 13.6 | 13.5 | FM1 | 1 | 28-1/4 | 27-7/8 | 18-3/4 | 195 | 70 |
C*ON100M4A** | YB08KAE | 1 | 3/8 | 5/8 | 10.8 | 11 | 10.9 | 13.3 | 13.6 | 13.5 | FM1 | 1 | 28-1/4 | 27-7/8 | 18-3/4 | 195 | 70 |
C*ON130E4A** | YS09KAE | 1 | 3/8 | 5/8 | 10.8 | 11 | 10.9 | 13.3 | 13.6 | 13.5 | FM1 | 1 | 28-1/4 | 27-7/8 | 18-3/4 | 195 | 70 |
C*ON150E4A** | YS11KAE | 1-1/4 | 1/2 | 7/8 | 13.3 | 13.6 | 13.5 | 17 | 17.4 | 17.2 | FM2 | 2 | 28-1/4 | 39-7/8 | 18-3/4 | 205 | 71 |
C*ON180E4A** | YS12KAE | 1-1/2 | 1/2 | 7/8 | 13.3 | 13.6 | 13.5 | 17 | 17.4 | 17.2 | FM2 | 2 | 28-1/4 | 39-7/8 | 18-3/4 | 210 | 71 |
C*ON200E4A** | YS14KAE | 2 | 1/2 | 7/8 | 14.9 | 15.2 | 15 | 20.5 | 20.9 | 20.7 | FM3 | 2 | 28-1/4 | 39-7/8 | 21-1/4 | 215 | 71 |
C*ON250E4A** | YS16KAE | 2-1/2 | 1/2 | 7/8 | 14.9 | 15.2 | 15 | 20.5 | 20.9 | 20.7 | FM3 | 2 | 28-1/4 | 39-7/8 | 21-1/4 | 230 | 72 |
C*ON280E4A** | YS19KAE | 2-3/4 | 5/8 | 1-1/8 | 27.4 | 27.9 | 27.7 | 37.1 | 37.8 | 37.5 | FM4 | 1 | 33 | 43-7/8 | 35 | 305 | 72 |
C*ON300E4A** | YS21KAE | 3 | 5/8 | 1-1/8 | 27.4 | 27.9 | 27.7 | 37.1 | 37.8 | 37.5 | FM4 | 1 | 33 | 43-7/8 | 35 | 305 | 72 |
C*ON350E4A** | YS24KAE | 3-1/2 | 5/8 | 1-1/8 | 27.4 | 27.9 | 27.7 | 37.1 | 37.8 | 37.5 | FM4 | 1 | 33 | 43-7/8 | 35 | 325 | 72 |
C*ON400E4A** | YS26KAE | 4 | 5/8 | 1-1/8 | 27.4 | 27.9 | 27.7 | 37.1 | 37.8 | 37.5 | FM4 | 1 | 33 | 43-7/8 | 35 | 352 | 74 |
C*ON450E4A** | YS30KAE | 4-1/2 | 5/8 | 1-1/8 | 27.4 | 27.9 | 27.7 | 37.1 | 37.8 | 37.5 | FM4 | 1 | 33 | 43-7/8 | 35 | 375 | 74 |
C*ON500E4A** | YS33KAE | 5 | 5/8 | 1-1/8 | 27.4 | 27.9 | 27.7 | 37.1 | 37.8 | 37.5 | FM4 | 1 | 33 | 43-7/8 | 35 | 383 | 74 |
C*ON600E4A** | YS40KAE | 6 | 5/8 | 1-1/8 | 27.4 | 27.9 | 27.7 | 37.1 | 37.8 | 37.5 | FM4 | 1 | 33 | 43-7/8 | 35 | 405 | 76 |
Low Temperature Scroll
Model No. | Comp. Model No. | HP | Connections (In.) Liquid |
Connections (In.) Suction |
Pump Down Capacity (lbs) 90% R454A |
Pump Down Capacity (lbs) 90% R454C |
Pump Down Capacity (lbs) 90% R455A |
Pump Down Capacity (lbs) Oversized Receiver 90% R454A |
Pump Down Capacity (lbs) Oversized Receiver 90% R454C |
Pump Down Capacity (lbs) Oversized Receiver 90% R455A |
Cabinet Size | Fan Qty | Dimensions (In.) D | Dimensions (In.) W | Dimensions (In.) H | Approx. Ship Wt. (Lbs) | Sound dBA |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C*ON100L4A** | YF03KAE | 1 | 3/8 | 5/8 | 10.8 | 11 | 10.9 | 13.3 | 13.6 | 13.5 | FM1 | 1 | 28-1/4 | 27-7/8 | 18-3/4 | 195 | 70 |
C*ON130L4A** | YF04KAE | 1-1/3 | 3/8 | 5/8 | 10.8 | 11 | 10.9 | 13.3 | 13.6 | 13.5 | FM1 | 1 | 28-1/4 | 27-7/8 | 18-3/4 | 195 | 70 |
C*ON160L4A** | YF05KAE | 1-1/2 | 3/8 | 5/8 | 10.8 | 11 | 10.9 | 13.3 | 13.6 | 13.5 | FM1 | 1 | 28-1/4 | 27-7/8 | 18-3/4 | 195 | 70 |
C*ON230L4A** | YF07KAE | 2-1/3 | 3/8 | 7/8 | 13.3 | 13.6 | 13.5 | 17 | 17.4 | 17.2 | FM2 | 2 | 28-1/4 | 39-7/8 | 18-3/4 | 230 | 71 |
C*ON250L4A** | YF06KSE | 2-1/2 | 3/8 | 7/8 | 14.9 | 15.2 | 15 | 20.5 | 20.9 | 20.7 | FM3 | 2 | 28-1/4 | 39-7/8 | 21-1/4 | 240 | 73 |
C*ON300L4A** | YF07KSE | 3 | 3/8 | 7/8 | 14.9 | 15.2 | 15 | 20.5 | 20.9 | 20.7 | FM3 | 2 | 28-1/4 | 39-7/8 | 21-1/4 | 245 | 73 |
C*ON350L4A** | YF09KSE | 3-1/2 | 3/8 | 7/8 | 14.9 | 15.2 | 15 | 20.5 | 20.9 | 20.7 | FM3 | 2 | 28-1/4 | 39-7/8 | 21-1/4 | 255 | 73 |
C*ON400L4A** | YF10KAE | 4 | 1/2 | 11/8 | 27.4 | 27.9 | 27.7 | 37.1 | 37.8 | 37.5 | FM4 | 1 | 33 | 43-7/8 | 35 | 352 | 73 |
C*ON500L4A** | YF13KAE | 5 | 1/2 | 11/8 | 27.4 | 27.9 | 27.7 | 37.1 | 37.8 | 37.5 | FM4 | 1 | 33 | 43-7/8 | 35 | 367 | 74 |
C*ON600L4A** | YF15KAE | 6 | 1/2 | 11/8 | 27.4 | 27.9 | 27.7 | 37.1 | 37.8 | 37.5 | FM4 | 1 | 33 | 43-7/8 | 35 | 383 | 76 |
Dimensional Drawings
Detailed dimensional drawings are provided for each cabinet size, illustrating the unit's physical layout and key measurements.
Cabinet Size FM1
Depth View: Shows dimensions of 28-1/4 (Depth) x 18-3/4 (Height). Key features indicated are AIR inlet, LIQUID OUT, SUCTION connection, CONTROL PANEL, and 3/8" MOUNTING HOLES (4).
Width View: Shows dimensions of 26-1/4 (Width). Key features indicated are LIQUID OUT, SUCTION connection, CONTROL PANEL, and 3/8" MOUNTING HOLES (4).
Cabinet Size FM2
Depth View: Shows dimensions of 28-1/4 (Depth) x 18-3/4 (Height). Key features indicated are AIR inlet, LIQUID OUT, SUCTION connection, CONTROL PANEL, and 3/8" MOUNTING HOLES (4).
Width View: Shows dimensions of 38-1/4 (Width). Key features indicated are LIQUID OUT, SUCTION connection, CONTROL PANEL, and 3/8" MOUNTING HOLES (4).
Cabinet Size FM3
Depth View: Shows dimensions of 28-1/4 (Depth) x 21-1/4 (Height). Key features indicated are AIR inlet, LIQUID OUT, SUCTION connection, CONTROL PANEL, and 3/8" MOUNTING HOLES (4).
Width View: Shows dimensions of 38-1/4 (Width). Key features indicated are LIQUID OUT, SUCTION connection, CONTROL PANEL, and 3/8" MOUNTING HOLES (4).
Cabinet Size FM4
Depth View: Shows dimensions of 33 (Depth) x 35 (Height). Key features indicated are AIR inlet, LIQUID OUT, SUCTION connection, CONTROL PANEL, and 3/8" MOUNTING HOLES (4).
Width View: Shows dimensions of 42-1/4 (Width). Key features indicated are LIQUID OUT, SUCTION connection, CONTROL PANEL, and 3/8" MOUNTING HOLES (4).
All dimensions are in inches.
Department of Energy Annual Walk-In Energy Factor (AWEF) Ratings
Medium/Extended Medium Temperature Scroll
Base Model No. | Cabinet Size | AWEF R454A | AWEF R454C | AWEF R455A |
---|---|---|---|---|
C*ON060M4A** | FM1 | 7.60 | 7.60 | 7.60 |
C*ON080M4A** | FM1 | 7.60 | 7.60 | 7.60 |
C*ON100M4A** | FM1 | 7.60 | 7.60 | 7.60 |
C*ON130E4A** | FM1 | 7.60 | 7.60 | 7.60 |
C*ON150E4A** | FM2 | 7.60 | 7.60 | 7.60 |
C*ON180E4A** | FM2 | 7.60 | 7.60 | 7.60 |
C*ON200E4A** | FM3 | 7.60 | 7.60 | 7.60 |
C*ON250E4A** | FM3 | 7.60 | 7.60 | 7.60 |
C*ON280E4A** | FM4 | 7.60 | 7.60 | 7.60 |
C*ON300E4A** | FM4 | 7.60 | 7.60 | 7.60 |
C*ON350E4A** | FM4 | 7.60 | 7.60 | 7.60 |
C*ON400E4A** | FM4 | 7.60 | 7.60 | 7.60 |
C*ON450E4A** | FM4 | 7.60 | 7.60 | 7.60 |
C*ON500E4A** | FM4 | 7.60 | 7.60 | 7.60 |
C*ON600E4A** | FM4 | 7.60 | 7.60 | 7.60 |
If the medium temperature model has a numerical value in the table above, the following statement applies: "This refrigeration system is designed and certified for use in walk-in cooler applications."
Low Temperature Scroll
Base Model No. | Cabinet Size | AWEF R454A | AWEF R454C | AWEF R455A |
---|---|---|---|---|
C*ON100L4A** | FM1 | 2.89 | 2.89 | 2.89 |
C*ON130L4A** | FM1 | 2.94 | 2.94 | 2.94 |
C*ON160L4A** | FM1 | 2.98 | 2.98 | 2.98 |
C*ON230L4A** | FM2 | 3.14 | 3.14 | 3.14 |
C*ON250L4A** | FM3 | 3.15 | 3.15 | 3.15 |
C*ON300L4A** | FM3 | 3.15 | 3.15 | 3.15 |
C*ON350L4A** | FM3 | 3.15 | 3.15 | 3.15 |
C*ON400L4A** | FM4 | 3.15 | 3.15 | 3.15 |
C*ON500L4A** | FM4 | 3.15 | 3.15 | 3.15 |
C*ON600L4A** | FM4 | 3.15 | 3.15 | 3.15 |
If the low temperature model has a numerical value in the table above, the following statement applies: "This refrigeration system is designed and certified for use in walk-in cooler applications."
* Each asterisk represents a variable character based upon model, refrigerant, voltage, and vintage ordered. See page 5 for nomenclature.