Introduction
The installation of this product is intended for adequately trained and experienced persons. You are installing the product at your own risk. If you are not sufficiently trained or experienced, or feel unsure about the installation procedure, please refrain from installing the product yourself and contact EKWB tech support for assistance. EKWB disclaims liability for any damages to the product and incidental, consequential, or indirect damages incurred due to improper or inappropriate installation.
Before you start using this product, please follow these basic guidelines:
- Read this manual carefully before beginning the installation process.
- EK-fittings require only a tiny amount of force to screw them firmly in place, as the rubber O-ring gaskets ensure the liquid seal.
- Corrosion-inhibiting, purpose-made coolants are always recommended for any liquid cooling system. EKWB recommends EK-CryoFuel coolants for worry-free usage.
Box Contents
Image shows the EK-Quantum Reflection² V3000 Plus D5 PWM D-RGB - Plexi distribution plate. Also depicted are the included accessories: an Allen Key 2.5 mm (1 pc), an EK-Loop Multi Allen Key (1 pc), eight M4 0.8 mm Washers, and eight M4 x 5 DIN7984 Screws. The mounting mechanism is identified as Reflection² V3000 Plus D5 PWM with EAN 106804.
- EK-Quantum Reflection² V3000 Plus D5 PWM D-RGB - Plexi (Main Product)
- Mounting mechanism - Reflection² V3000 Plus D5 PWM; EAN 106804
- Allen Key 2.5 mm (1 pc)
- EK-Loop Multi Allen Key (1 pc)
- M4 0.8 mm Washer (8 pcs)
- Screw M4 x 5 DIN7984 (8 pcs)
Distribution Plate Dimensions
Diagrams display the dimensions of the distribution plate from the front, side, and top views, with various measurements indicated in millimeters. Key dimensions include overall height (555 mm), width (157.5 mm), and depth (88.3 mm), along with specific port and mounting hole placements.
- Overall Height: 555 mm
- Overall Width: 157.5 mm
- Overall Depth: 88.3 mm
- Various port and mounting point dimensions are detailed in the diagrams.
Technical Specifications and Product Parts
Technical Specification:
- Dimensions with the attached pump (W x D x H): 157.5 x 88.3 x 555 mm
- Reservoir volume: ~550 ml
- D-RGB LED count: 32
- D-RGB cable length: 800 mm
- D-RGB connector standard: 3-pin (+5V, Data, Blocked, Ground)
An exploded view diagram illustrates all components of the distribution plate assembly, with numbered parts corresponding to the table below.
Position | EAN | Description | Quantity |
---|---|---|---|
1 | 106801 | TOP Plexi (Lid part) | 1 |
2 | 106800 | TOP Plexi (Block part) | 1 |
3 | 105913 | Pump holder | 1 |
4 | 106799 | LED Cover (Black e.) | 1 |
5 | 8311 | Screw M4 x 20 DIN7984 | 4 |
6 | 5154 | OR 52 x3 NBR50 | 1 |
7 | 3831109837597 | EK D5 Pump | 1 |
8 | 104599 | Mylar sticker | 1 |
9 | 100663 | EK - Badge | 1 |
10 | 100815 | LED D-RGB strip 800/600 mm | 1 |
11 | 102639 | EK - Plug G1/4 | 12 |
12 | 3831109834282 | EK-Quantum Torque Plug Cover - Black | 12 |
13 | 106792 | OR-V3000 Plus D5 PWM Set | 1 |
14 | 8312 | Screw M4 x 16 DIN7991 | 71 |
15 | 9051 | Screw M4 x 25 DIN7991 | 6 |
16 | 9054 | Screw M4 x 16 DIN7984 | 8 |
17 | 106803 | Metal mounting Plate (Black) | 1 |
Preparing the Chassis
Step 1: Panel Removal
Diagram shows a PC case with arrows indicating the removal of the front panel, top panel, and side panels.
⚠️ IMPORTANT: Before installing the distribution plate, carefully read your PC case manual.
First, remove the PC case's front panel. After that, you can remove the top and side panels.
Step 2: Internal Component Removal
Diagram shows the interior of a PC case with arrows indicating the removal of internal components, specifically SSD plates and the PSU shroud.
After removing the exterior panels, the inner two (2) SSD plates (located beside the motherboard) and the PSU Shroud also need to be detached.
Step 3: Drive Cage Removal
Diagram shows the interior of a PC case with arrows indicating the removal of drive cages.
To fully utilize the distribution plate's potential, you must also remove the two (2) drive cages.
Note: If you will not use the side radiator configuration, one of the drive cages can still be inserted back into the case.
Installing the Distribution Plate
Step 1: Placement
Diagram shows the inside of a PC chassis with the distribution plate being carefully inserted into its mounting location.
⚠️ IMPORTANT: It is recommended that a distribution plate is installed into the chassis before radiators with fans.
Carefully insert the distribution plate into the PC Chassis.
Step 2: Securing the Plate
Diagram shows the rear of the PC chassis with screws and washers being used to secure the distribution plate. Required tools and parts are also illustrated.
Secure the distribution plate from the backside using eight (8) M4x5 DIN7984 Screws and eight (8) M4 0.8 mm Washers with the provided Allen Key 2.5 mm.
For this step you will need:
- Allen Key 2.5 mm (1 pc)
- M4x5 DIN7984 Screw (8 pcs)
- M4 0.8 mm Washer (8 pcs)
Recommended Distribution Plate Configurations
A diagram of the distribution plate shows the layout of all ports, labeled as: FILL, TOP RADIATOR INLET, TOP RADIATOR OUTLET, CPU OUTLET, CPU INLET, GPU OUTLET, GPU INLET, DRAIN, SIDE RADIATOR INLET, FRONT RADIATOR INLET, and FRONT/SIDE RADIATOR OUTLET.
To complete your loop, all ports must be used as marked in the image.
All remaining unused ports must be closed with supplied plugs, using the EK-Loop Multi Allen Key.
⚠️ IMPORTANT: If one of the prescribed components will not be installed (i.e., side radiator or GPU block), then one INLET and one OUTLET port must still be joined together in order for this distribution plate to function!
⚠️ IMPORTANT: Only one INLET and one OUTLET port for the GPU connection can be used, while all other INLET and OUTLET GPU ports must be closed with G1/4 plugs.
A separate diagram highlights the FILL port on the top and the DRAIN port on the bottom of the distribution plate.
Flow Diagram
The flow diagram illustrates the path of coolant through the distribution plate, showing entry and exit points for radiators, CPU, and GPU, with arrows indicating the direction of flow. The diagram depicts how coolant circulates within the internal channels of the plate.
Connecting Components
D-RGB LED Strip Connection
Diagram shows a 3-pin D-RGB connector and a motherboard header labeled "D-RGB Header" and "RGB Header".
Plug the 3-pin connector of the distribution plate's D-RGB LED light to the D-RGB HEADER on the motherboard. The LED will work if the pin layout on the header is as follows: +5V, Digital, Empty, Ground.
Pump Connection
Diagram shows a SATA power connector labeled "SATA CONNECTOR" and a 4-pin PWM fan connector labeled "4-PIN PWM FAN CONNECTOR".
The EK-D5 PWM pump has two connectors:
- SATA Connector: It must be connected directly to your PSU at all times as it is used to power the pump.
- 4-pin PWM fan: It can be connected to your motherboard's CPU_ Fan or designated water pump header, or to a controller. This cable is used to control and report the rotational speed of the pump. If it's not connected, the pump will run at maximum speed (100% PWM).
Testing the Loop
To ensure the installation of EK components was successful, EKWB recommends performing a leak test for 24 hours.
When your loop is complete and filled with coolant, connect the pump to a PSU outside of your system. Do not connect power to any of the other components. Turn on the PSU and let the pump run continuously. It is normal for the coolant level to drop during this process as air collects in the distribution plate.
Inspect all parts of the loop. In the eventuality that coolant leaks, fix the issue and repeat the testing process. Ensure that all hardware is dry before the system is powered on in order to prevent any damage.
Support and Service
In case you need assistance or wish to order spare parts or a new mounting mechanism, please contact EKWB support:
https://www.ekwb.com/customer-support/
For spare parts orders, refer to the "TECHNICAL SPECIFICATIONS AND PRODUCT PARTS" page where you can find the EAN number of each part you might need. Include the EAN number with quantity in your request. The Mounting Mechanism EAN can be found under "BOX CONTENTS".