EK-Quantum Kinetic³ FLT D5 PWM D-RGB Installation Manual

Basic Guidelines

Before starting, please follow these basic guidelines:

Please carefully read the manual before beginning the installation process.

The EK fittings require only a small amount of force to screw them firmly in place, as the liquid seal is ensured by the rubber o-ring gaskets.

The use of corrosion inhibiting coolants is always recommended for any liquid cooling system. EKWB recommends EK-Cryofuel for worry-free usage.

There are many ways to install your EK-Quantum Kinetic³ FLT Body as it utilizes a standard fan mounting hole pattern with 15 mm spacing, the same as all EK radiators. The mounting holes have standard M4 threads with maximum engagement of 10 mm. Use of longer screws or screws with incorrect threads, such as those intended for fans or radiators, may damage your product!

Box Contents

Diagram showing the EK-Quantum Kinetic³ FLT reservoir body, available in 92/120/140/240/280/360 sizes.

Diagram of L-Side Mount Bracket 120 (1 pc for 92 Version, 2 pcs for 120/240/360 Versions).

Diagram of L-Side Mount Bracket 140 (2 pcs for 140/280 Versions).

Diagram of EK-Loop Multi Allen Key (1 pc).

Diagram of M4 x 8 DIN7984 Screw (4 pcs, 2 pcs for 92 Version).

Diagram of M4 x 4 7984DIN Screw (4 pcs, 2 pcs for 92 Version).

Diagram of M4 x 10 DIN7984 Screw (4 pcs, 2 pcs for 92 Version).

Diagram of M4 Nut (4 pcs, 2 pcs for 92 Version).

Diagram of Allen Key 2.5 mm (1 pc).

Diagram of PVC Washer M4 (4 pcs, 2 pcs for 92 Version).

Mounting Mechanism EANs:

Reservoir Dimensions

92 Version

Dimensions: 92 mm (Width) x 118.5 mm (Height) x 77 mm (Depth)

120 Version

Dimensions: 120 mm (Width) x 118.5 mm (Height) x 77 mm (Depth)

140 Version

Dimensions: 140 mm (Width) x 238.5 mm (Height) x 77 mm (Depth)

240 Version

Dimensions: 120 mm (Width) x 238.5 mm (Height) x 77 mm (Depth)

280 Version

Dimensions: 120 mm (Width) x 278.5 mm (Height) x 77 mm (Depth)

360 Version

Dimensions: 120 mm (Width) x 358.5 mm (Height) x 77 mm (Depth)

Technical Specifications and Product Parts

92 VERSION

Technical Specification:

Diagram showing an exploded view of the 92 Version components with numbered parts.

PositionEANDescriptionQuantity
1107327TOP Plexi - Block FLT 921
2107333TOP Plexi - Lid FLT 921
3107339Mylar Label1
49040Screw M3 x 28 DIN79912
5100663EK Badge1
65154OR 52 x 31
7105913Pump holder1
88311Screw M4 x 20 DIN79844
93831109837597Pump EK-D5 PWM1
10107313Pump holder1
113831109834282Plug Cover5
12102639EK-Plug G1/45
138312Screw M4 x 16 DIN799110
14107341OR - FLT 921
15103155LED Strip1

120 VERSION

Technical Specification:

Diagram showing an exploded view of the 120 Version components with numbered parts.

PositionEANDescriptionQuantity
1107328TOP Plexi - Block FLT 1201
2107334TOP Plexi - Lid FLT 1201
3107339Mylar Label1
49040Screw M3 x 28 DIN79912
5100663EK Badge1
65154OR 52 x 31
7105913Pump holder1
88311Screw M4 x 20 DIN79844
93831109837597Pump EK-D5 PWM1
10107313Pump holder1
113831109834282Plug Cover7
12102639EK-Plug G1/47
138312Screw M4 x 16 DIN799112
14107342OR - FLT 1201
15103155LED Strip1

140 VERSION

Technical Specification:

Diagram showing an exploded view of the 140 Version components with numbered parts.

PositionEANDescriptionQuantity
1107329TOP Plexi - Block FLT 1401
2107335TOP Plexi - Lid FLT 1401
3107339Mylar Label1
49040Screw M3 x 28 DIN79912
5100663EK Badge1
65154OR 52 x 31
7105913Pump holder1
88311Screw M4 x 20 DIN79844
93831109837597Pump EK-D5 PWM1
10107314Pump holder1
113831109834282Plug Cover7
12102639EK-Plug G1/47
138312Screw M4 x 16 DIN799112
14107343OR - FLT 1401
15103155LED Strip1

240 VERSION

Technical Specification:

Diagram showing an exploded view of the 240 Version components with numbered parts.

PositionEANDescriptionQuantity
1107330TOP Plexi - Block FLT 2401
2107336TOP Plexi - Lid FLT 2401
39040Screw M3 x 28 DIN79912
4102639EK-Plug G1/49
53831109834282Plug Cover9
6107318LED Cover1
7107339Mylar Label1
8107347OR - FLT 1201
9100663EK Badge1
103831109837597Pump EK-D5 PWM1
115154OR 52 x 31
12105913Pump holder1
138311Screw M4 x 20 DIN79844
14107344OR - Kinetic³ FLT 2401
158312Screw M4 x 16 DIN799117
16102711LED Strip1

280 VERSION

Technical Specification:

Diagram showing an exploded view of the 280 Version components with numbered parts.

PositionEANDescriptionQuantity
1107331TOP Plexi - Block FLT 2801
2107337TOP Plexi - Lid FLT 2801
39040Screw M3 x 28 DIN79912
4102639EK-Plug G1/49
53831109834282Plug Cover9
6107321LED Cover1
7107339Mylar Label1
8100663EK Badge1
93831109837597Pump EK-D5 PWM1
105154OR 52 x 31
11105913Pump holder1
128311Screw M4 x 20 DIN79844
13107345OR - Kinetic³ FLT 2801
148312Screw M4 x 16 DIN799119
15107360OR - FLT 1401
16102711LED Strip1

360 VERSION

Technical Specification:

Diagram showing an exploded view of the 360 Version components with numbered parts.

PositionEANDescriptionQuantity
1107332TOP Plexi - Block FLT 3601
2107338TOP Plexi - Lid FLT 3601
39040Screw M3 x 28 DIN79912
4102639EK-Plug G1/49
53831109834282Plug Cover9
6107324LED Cover1
7107339Mylar Label1
8107347OR FLT 1201
9100663EK Badge1
103831109837597Pump EK-D5 PWM1
115154OR 52 x 31
12105913Pump holder1
138311Screw M4 x 20 DIN79844
14107346OR - Kinetic³ FLT 3601
158312Screw M4 x 16 DIN799123
16102711LED Strip1

Mounting Orientation

The FLT Reservoir can be mounted in multiple directions. Vertical and horizontal positions are optional.

Do not mount FLT Reservoir when the pump is in dead position. ⚠️

Correct mounting: ✔️

Incorrect mounting:

Installing EK-Quantum Kinetic³ FLT Directly to the Chassis

Using the included M4 screws, you can mount the reservoir directly to your chassis or any other standard fan mounting location.

Diagram showing a PC chassis with arrows indicating mounting points for the reservoir using M4 x 10 DIN7984 screws.

For this step, you will need:

Installing EK-Quantum Kinetic³ FLT with Supplied Mounts

EK provides a Kinetic³ Side Mount Bracket along with M4 nuts, washers, and screws to allow the installation of the reservoir onto fans, radiators, or PC cases. The bracket can be positioned across any pair of mounting holes in various orientations.

Example: EK-Quantum Kinetic³ FLT 240 mounted on a radiator.

STEP 1

Screw the bracket onto the radiator using the supplied four (4) M4x4 DIN7984 screws with the 2.5 mm allen key.

For this step, you will need:

STEP 2

To secure the reservoir, use four (4) M4x8 DIN7984 screws with the 2.5 mm allen key. In this configuration, the ports on the reservoir are aligned with the ports on the radiator.

For this step, you will need:

Attaching the Fittings

92 Version

EK-Quantum Kinetic³ FLT 92 has two inlet and two outlet ports; one of each must be used! All unused ports should be blocked using G1/4 plugs.

Diagram showing the 92 Version reservoir ports labeled: FILL, INLET, OUTLET/DRAIN.

120/140 Version

EK-Quantum Kinetic³ FLT 120/140 has three inlet and three outlet ports; one of each must be used! All unused ports should be blocked using G1/4 plugs.

Diagram showing the 120/140 Version reservoir ports labeled: FILL, INLET, OUTLET/DRAIN.

240/280/360 Version

EK-Quantum Kinetic³ FLT 240/280/360 has three inlet and three outlet ports; one of each must be used! All unused ports should be blocked using G1/4 plugs.

Diagram showing the 240/280/360 Version reservoir ports labeled: FILL, INLET, OUTLET/DRAIN, ROUTING/SPLITTING PORT.

Connecting the D-RGB LED Strip

Plug the 3-pin connector from the water block's D-RGB LED light into the D-RGB HEADER on the motherboard. The LED will work if the pin layout on the header is as follows: +5V, Digital.

⚠️ Please ensure that the arrow indicated on the connector is plugged into the +5V line as indicated on your motherboard. Failure to do so will damage your motherboard or LED strip.

Connecting the Pump

The EK-D5 Pump has two connectors:

  1. SATA Connector: It must be connected directly to your PSU at all times as it is used to power the pump.
  2. 4-pin PWM fan: It can be connected to your motherboard's CPU_ Fan or designated water pump header. It can also be connected to a controller. This cable is used to control and report the rotational speed of the pump. If it's not connected, the pump will run at maximum speed (100% PWM).

Testing the Loop

To ensure the installation of EK components was successful, perform a leak test for 24 hours.

When your loop is complete and filled with coolant, connect the pump to a PSU outside of your system. Do not connect power to any of the other components. Turn on the PSU and let the pump run continuously. It is normal for the coolant level to drop during this process as air collects in the reservoir.

Inspect all parts of the loop. In the eventuality that coolant leaks, fix the issue and repeat the testing process. Ensure that all hardware is dry before the system is powered on to prevent any damage.

Support and Service

For assistance or to order spare parts or a new mounting mechanism, please contact:

https://www.ekwb.com/customer-support/

For spare parts orders, refer to the "TECHNICAL SPECIFICATIONS AND PRODUCT PARTS" section to find the EAN number of each part you might need. Include the EAN number with quantity in your request. Mounting Mechanism EANs can be found under "BOX CONTENTS".

Thermal pads are readily available in the EK shop.

Social Media

PDF preview unavailable. Download the PDF instead.

39ed59ecf70a4a68fa242c71e10785fd0ee143f33353abf62877886dbde2d24e ?v=1731053132 Adobe PDF Library 17.0 Adobe InDesign 19.4 (Windows)

Related Documents

Preview EK-Quantum Inertia D5 PWM Installation Manual
Comprehensive installation guide for the EK-Quantum Inertia D5 PWM pump, detailing unboxing, mounting, connections, and testing for PC liquid cooling systems.
Preview EK-Quantum Reflection² V3000 Plus D5 PWM D-RGB - Plexi Distribution Plate User Guide
This comprehensive user guide provides detailed instructions for the EK-Quantum Reflection² V3000 Plus D5 PWM D-RGB - Plexi distribution plate. Learn about its features, installation, port configuration, and maintenance for your custom PC water cooling loop.
Preview EK-Pro Pump Reservoir Manifold X6 D5 – Acetal User Guide
Comprehensive user guide for the EK-Pro Pump Reservoir Manifold X6 D5 – Acetal, detailing installation, specifications, and usage for PC liquid cooling systems.
Preview EK-Quantum Surface Radiator Setup Configurations - User Guide
Detailed user guide for EK-Quantum Surface Radiators, covering setup configurations, exploded views of components for S, P, and X series, and support information. Learn how to install and configure your EK-Quantum Surface radiator for optimal performance in your custom liquid cooling loop.
Preview EK-Quantum Volume / Kinetic FLT Installation Manual
This manual provides detailed instructions for installing the EK-Quantum Volume / Kinetic FLT reservoir, including direct mounting, using supplied mounts, and connecting D-RGB LED strips.
Preview EK-Quantum Reflection Obsidian 1000D Distribution Plate User Guide
User guide for the EK-Quantum Reflection Obsidian 1000D distribution plate, detailing installation, port configurations, D-RGB LED connection, pump connection, and leak testing for PC liquid cooling systems.
Preview EK-XTOP Revo D5 PWM Installation and Mounting Manual
This manual provides detailed instructions for installing and mounting the EK-XTOP Revo D5 PWM pump top, covering pump preparation, drilling mounting holes, assembling the XTOP with the pump, attaching fittings, and proper priming procedures. It also includes important disclosures regarding leak testing, warranty, and product usage.
Preview EK-Quantum Surface Radiator Setup Configurations - User Guide
This user guide provides detailed setup configurations, flow direction options, and component breakdowns for EKWB's EK-Quantum Surface Radiators, including S, P, and X series. It covers installation guidelines, port usage, and support information.