Aprilaire Healthy Air System Product Guide
Quick Reference | September 2021
For more product information, refer to individual product guides at AprilairePartners.com or call 800.334.6011.
Humidifiers
Aprilaire offers a range of humidifiers designed to maintain optimal humidity levels in homes. These include steam, fan-powered, and bypass evaporative models, catering to various HVAC system types and household needs.
Series | Type of Humidification | Unit Size | Electrical | Opening | Gallons Per Day (GPD) | Width x Height x Depth | Data |
---|---|---|---|---|---|---|---|
800 SERIES | Steam | #8080 | 120V 60Hz 11.5A 1400W | 10" x 20" x 7" | 34.6 GPD | 11.5" x 16" x 10.5" | Ductless Steam. Included: Fan Pack, Finished Grille. For applications when a forced-air heating source is not present. |
800 SERIES | Steam | #801* | 120V 60Hz 11.5A 1400W | 10" x 20" x 7" | 34.6 GPD | 11.5" x 16" x 10.5" | Ductless Steam. Included: Fan Pack, Finished Grille. For applications when a forced-air heating source is not present. |
800 SERIES | Steam | #865* #88665* | 120V 60Hz 11.5A 1400W | 10" x 20" x 7" | 34.6 GPD | 11.5" x 16" x 10.5" | Ductless Steam. Included: Fan Pack, Finished Grille. For applications when a forced-air heating source is not present. |
800 SERIES | Steam | #700* | 120V 60Hz 11.5A 1400W | 10" x 20" x 7" | 34.6 GPD | 11.5" x 16" x 10.5" | Ductless Steam. Included: Fan Pack, Finished Grille. For applications when a forced-air heating source is not present. |
400 SERIES | Fan Powered Evaporative | #4028 | 120V 60Hz 0.8A 100W | 14" x 14" | 18 GPD | 14" x 14" x 7" | Built-in fan that pulls air directly from the furnace. |
500 SERIES | Large Bypass Evaporative | #500* #500M** | 24V 60Hz 0.5A | 15" x 15" opening | 17 GPD | 10" x 12.5" | Uses the furnace blower to move air through a Water Panel. |
500 SERIES | Small Bypass Evaporative | #500* #500M** | 24V 60Hz 0.5A | 6" dia. round opening | 12 GPD | 9.5" x 9.5" | Designed for smaller homes. Uses 100% of water and evaporative technology. Conserves water. |
600 SERIES | Large Bypass Evaporative | #600* #600M** | 24V 60Hz 0.5A | 15" x 15" opening | 17 GPD | 10" x 12.5" | Uses the furnace blower to move air through a Water Panel. |
700 SERIES | Fan Powered Evaporative | #700* #700M** | 120V 60Hz 0.8A 100W | 14" x 14" | 18 GPD | 14" x 14" x 7" | Built-in fan that pulls air directly from the furnace. |
300 SERIES | Small Bypass Evaporative | #300* #300M** | 24V 60Hz 0.5A | 6" dia. round opening | 12 GPD | 9.5" x 9.5" | Designed for smaller homes. Uses 100% of water and evaporative technology. Conserves water. |
300 SERIES | Self-Contained Evaporative | #300* | 120V 60Hz 0.7A | See note on heat pumps | 13 GPD | - | For boilers, mini-splits, radiant heat and ductless systems. Conserves water. |
Structure Tightness (8 Ft Ceilings) | 1000 Ft² | 1500 Ft² | 2000 Ft² | 2500 Ft² | 3000 Ft² | 4000 Ft² | 5000 Ft² |
---|---|---|---|---|---|---|---|
Tight | 3.3 GPD | 5.0 GPD | 6.7 GPD | 8.3 GPD | 10.0 GPD | 13.4 GPD | 16.7 GPD |
Average | 5.0 GPD | 7.5 GPD | 10.0 GPD | 12.5 GPD | 15.0 GPD | 20.0 GPD | 25.0 GPD |
Loose | 6.7 GPD | 10.0 GPD | 13.4 GPD | 16.7 GPD | 20.0 GPD | 26.7 GPD | 33.4 GPD |
*Automatic Digital Control (shown). **Manual Control.
Model 800LC available with 80LC canister for less conductive water 75-300 S/cm and 120VAC applications.
A family of 4 will add 2 gallons of humidity per day through everyday activities like breathing, cooking, bathing and washing. Evaporative capacities assume blower is active 100% of the time, plenum temperature is at 120°F and water is cold.
By-pass Humidifiers can be installed on the supply or return plenum.
Water Usage Rate Models 350 and 360 are 6 gph (gallons per hour); Models 500, 600 and 700 are 3 gph; Model 400 is 0.7 gph; Model 800 is 0.6 to 1.8 gph depending on voltage, amp draw and water quality.
Regional Humidifier Applications
Aprilaire humidifiers can be installed on many different types of HVAC equipment and controlled to provide optimal humidity levels. This application guide is to assist in the selection of the appropriate Aprilaire product based upon geography and heating equipment. The Aprilaire humidifier product portfolio consists of evaporative flow through, fan-powered products and residential steam. It's important to consider the plenum temperature, air flow (fan speed) and run time (heat call primary, fan only call secondary) when selecting products.
Aprilaire's control strategy will maximize the humidifier run time/capacity. The automatic humidity controls have an integrated blower activation relay. This relay is factory set to "ON". It will turn on the humidifier and the HVAC blower for humidification without a heat call. This will dramatically increase the capacity of the humidifier. Installations with a manual humidifier control can increase capacity by turning the thermostat fan to "ON". When installing evaporative humidifiers, it's recommended they are plumbed to hot water.
Equipment | CLIMATE ZONE | ||||
---|---|---|---|---|---|
MIDWEST/ NORTHEAST | MID-ATLANTIC/ MID-SOUTHERN | MOUNTAIN | SOUTH | DESERT (SOUTHWEST) | |
Gas/Oil Furnace-Single Stage or Multi Stage* | 400/500/600/700/800 | 400/500/600/700/800 | 400/500/600/700/800 | 500/600/700/800 | 800 |
Gas/Oil Modulating Furnace** | 700/800 | 700/800 | 700/800 | 700/800 | 800 |
Heat Pump/Geo-Single Stage or Multi Stage* | 400/500/600/700/800 | 400/500/600/700/800 | 400/500/600/700/800 | 500/600/700/800 | 800 |
Heat Pump/Geo-Modulating** | 700/800 | 700/800 | 700/800 | 700/800 | 800 |
Boiler With AHU (No Heat Source) | 800 | 800 | 800 | 800 | 800 |
Boiler With AHU and Hot Water Coil/ Hydro Air Unit Boiler | 700/800 | 700/800 | 800 | 800 | 800 |
Electric Baseboard Heating | 300/865 | 300/865 | 300/865 | 300/865 | 300/865 |
Humidifying with A/C Unit | 800 | 800 | 800 | 800 | 800 |
*PSC, constant torque ECM **Variable speed ECM Evaporative performance of bypass humidifiers decreases with lower airflow volume and lower air temperature. Bypass models can be used in these applications if the HVAC system pressure differential between supply and return ducts is at least 0.08 in. wg and air temperature, hot water and continuous fan in the supply duct is at least 100°F.
Dehumidifiers
Dehumidifiers are an integral part of the Aprilaire Healthy Air System, designed to manage excess moisture and improve indoor air quality.
Model | Unit Size (W x H x L) | Capacity (ppd = Pints Per Day) | Airflow @ Varying E.S.P. (in. w.c.) | Unit Weight (lbs.) | Warranty |
---|---|---|---|---|---|
#E070 | 12.5" x 12.5" x 25" | 70 ppd | 0.0" w.c. 200 CFM 0.2" w.c. 170 CFM 0.4" w.c. 140 CFM |
56 | 5 YEAR |
#E080 #E080H1 |
14" x 15" x 26" | 80 ppd | 0.0" w.c. 185 CFM 0.2" w.c. 135 CFM 0.4" w.c. 85 CFM |
63 | 5 YEAR |
#E100 #E100H1 #E100C2 |
14" x 15" x 26" | 100 ppd | 0.0" w.c. 280 CFM 0.2" w.c. 245 CFM 0.4" w.c. 210 CFM |
64 | 5 YEAR |
#E130 #E130H1 #E130C2 |
19½" x 18½" x 30" | 130 ppd | 0.0" w.c. 310 CFM 0.2" w.c. 270 CFM 0.4" w.c. 225 CFM |
98 | 5 YEAR |
#E080H, E100H and E130H are hardwired units. #E100C and E130C are on casters.
Region | Structure Tightness | |||||
---|---|---|---|---|---|---|
Loose | Tight | Loose | Tight | Loose | Tight | |
Region A | Region A | Region B | Region B | Region C | Region C | |
Model E080 | 3,200 Ft² | 4,400 Ft² | 4,000 Ft² | 5,500 Ft² | 5,200 Ft² | 7,200 Ft² |
Model E100 | 2,600 Ft² | 3,900 Ft² | 3,200 Ft² | 5,000 Ft² | 3,900 Ft² | 6,500 Ft² |
Model E130 | 1,600 Ft² | 2,300 Ft² | 2,000 Ft² | 3,000 Ft² | 2,300 Ft² | 3,600 Ft² |
The recommended home floor area that each listed dehumidifier can dehumidify is for sizing guidelines only. Actual home size is dependent on location, ventilation rate, occupant habits, A/C moisture removal, and environmental conditions. Values are for the most humid locations within each region. Provide on-demand sizing recommendations using the Dehumidifier Selection Assistant at aprilairepartners.com/dsa.
Air Filtration
Aprilaire offers a comprehensive range of air cleaners and filters designed to remove airborne particles, allergens, and odors, contributing to a healthier indoor environment.
Air Cleaners
Model | Nominal Size (in Inches) | Cabinet Size (W x H x D) | Shipping Weight (lbs) | Included Filter | Compatible Filters* |
---|---|---|---|---|---|
#2216 | 20 x 25 | 6⅝" x 22¹⁄₁₆" x 27⅜" | 20 | MERV 16 | 216, 213CBN, 210 |
#2416 | 16 x 25 | 6⅝" x 17¾" x 30¹⁄₁₆" | 19.25 | MERV 16 | 416, 413CBN, 410 |
#2516 | 31 x 28 | 6⅝" x 31" x 30¹⁄₁₆" | 24.9 | MERV 16 | 516, 513CBN, 510 |
#2210 | 20 x 25 | 6⅝" x 22¹⁄₁₆" x 27⅜" | 19 | MERV 13 | 213, 213CBN, 210 |
#2310 | 20 x 20 | 6⅝" x 20⅜" x 22¹⁄₁₆" | 17 | MERV 13 | 313, 310 |
#2410 | 16 x 25 | 6⅝" x 17¾" x 30¹⁄₁₆" | 19 | MERV 13 | 413, 413CBN, 410 |
#1110 | 16 x 20 | 6⅝" x 17¾" x 22¹⁄₁₆" | 13 | MERV 11 | 113, 110 |
#1210 | 20 x 25 | 6⅝" x 22¹⁄₁₆" x 27⅜" | 20 | MERV 11 | 213, 213CBN, 210 |
#1310 | 20 x 20 | 6⅝" x 20⅜" x 22¹⁄₁₆" | 15 | MERV 11 | 313, 310 |
#1410 | 16 x 25 | 6⅝" x 17¾" x 30¹⁄₁₆" | 19 | MERV 11 | 413, 413CBN, 410 |
#1510 | 31 x 28 | 6⅝" x 31" x 30¹⁄₁₆" | 28 | MERV 11 | 510, 513CBN, 513 |
#1910 | 25 x 20 | 6⅝" x 25¹⁄₁₆" x 22¹⁄₁₆" | 18 | MERV 11 | 910, 913 |
#1610 | 16 x 25 | 6" x 17½" x 30¼" | 31 | MERV 11 | 610, 613 |
#1620 | 20 x 25 | 6" x 22⅛" x 27⅜" | 32.4 | MERV 13 | 410, 416, 413CBN, 413 |
*Included filter model is also available as a replacement option.
Model No. | Nominal Size (in Inches) | Filter Model | Shipping Weight |
---|---|---|---|
1625FG11 | 16 x 25 | 610 | 16 lbs. |
1625FG13 | 16 x 25 | 613 | 18 lbs. |
2025FG11 | 20 x 25 | 810 | 18 lbs. |
2025FG13 | 20 x 25 | 813 | 18 lbs. |
*Recommended grille face velocity is 300-450 fpm. To minimize risk of noise, use two filter grilles on systems over 3.5 tons.
Air Cleaner Filters
Filter No. | MERV Rating | CFM Values |
---|---|---|
216 | MERV 16 ALLERGY & ASTHMA | 200: 0.06, 400: 0.09, 600: 0.13, 800: 0.17, 1000: 0.23, 1200: 0.29, 1400: 0.36 |
416 | 200: 0.07, 400: 0.10, 600: 0.13, 800: 0.18, 1000: 0.24, 1200: 0.31 | |
516 | 200: 0.04, 400: 0.05, 600: 0.07, 800: 0.09, 1000: 0.10, 1200: 0.13, 1400: 0.15, 1600: 0.18, 1800: 0.21, 2000: 0.24, 2200: 0.27, 2400: 0.31 | |
113 | MERV 13 HEALTHY HOME | 200: 0.03, 400: 0.07, 600: 0.11, 800: 0.16, 1000: 0.22, 1200: 0.29 |
213 | 200: 0.02, 400: 0.04, 600: 0.06, 800: 0.09, 1000: 0.12, 1200: 0.15, 1400: 0.19, 1600: 0.23, 1800: 0.27, 2000: 0.31 | |
313 | 200: 0.03, 400: 0.05, 600: 0.09, 800: 0.13, 1000: 0.17, 1200: 0.23 | |
413 | MERV 13 HEALTHY HOME | 200: 0.02, 400: 0.05, 600: 0.07, 800: 0.10, 1000: 0.14, 1200: 0.17, 1400: 0.22, 1600: 0.26, 1800: 0.31, 2000: 0.37 |
513 | 200: 0.01, 400: 0.02, 600: 0.04, 800: 0.05, 1000: 0.05, 1200: 0.07, 1400: 0.08, 1600: 0.10, 1800: 0.11, 2000: 0.13, 2200: 0.15, 2400: 0.17, 2600: 0.18, 2800: 0.20, 3000: 0.23 | |
613 | MERV 13 HEALTHY HOME | 200: 0.02, 400: 0.05, 600: 0.07, 800: 0.10, 1000: 0.14, 1200: 0.17, 1400: 0.22, 1600: 0.26, 1800: 0.31, 2000: 0.37 |
813 | 200: 0.02, 400: 0.04, 600: 0.06, 800: 0.09, 1000: 0.12, 1200: 0.15, 1400: 0.19, 1600: 0.23, 1800: 0.27, 2000: 0.31 | |
913 | MERV 13 HEALTHY HOME | 200: 0.04, 400: 0.07, 600: 0.10, 800: 0.13, 1000: 0.17, 1200: 0.22, 1400: 0.25, 1600: 0.30, 1800: 0.35 |
213CBN | MERV 13 ODOR REDUCTION | 200: 0.04, 400: 0.07, 600: 0.10, 800: 0.13, 1000: 0.17, 1200: 0.21, 1400: 0.25, 1600: 0.30, 1800: 0.35 |
413CBN | 200: 0.04, 400: 0.07, 600: 0.10, 800: 0.14, 1000: 0.19, 1200: 0.24, 1400: 0.29, 1600: 0.36, 1800: 0.43 | |
513CBN | MERV 11 CLEAN AIR | 200: 0.03, 400: 0.04, 600: 0.05, 800: 0.07, 1000: 0.08, 1200: 0.10, 1400: 0.12, 1600: 0.15, 1800: 0.17, 2000: 0.20, 2200: 0.22, 2400: 0.25, 2600: 0.29, 2800: 0.32 |
110 | 200: 0.02, 400: 0.05, 600: 0.06, 800: 0.10, 1000: 0.14, 1200: 0.20 | |
210 | 200: 0.02, 400: 0.03, 600: 0.04, 800: 0.06, 1000: 0.08, 1200: 0.11, 1400: 0.13, 1600: 0.16, 1800: 0.19, 2000: 0.22 | |
310 | 200: 0.02, 400: 0.04, 600: 0.06, 800: 0.10, 1000: 0.14, 1200: 0.19 | |
410 | MERV 11 CLEAN AIR | 200: 0.02, 400: 0.03, 600: 0.05, 800: 0.07, 1000: 0.09, 1200: 0.12, 1400: 0.15, 1600: 0.19, 1800: 0.22, 2000: 0.27 |
510 | 200: 0.02, 400: 0.02, 600: 0.03, 800: 0.04, 1000: 0.04, 1200: 0.05, 1400: 0.06, 1600: 0.07, 1800: 0.09, 2000: 0.10, 2200: 0.12, 2400: 0.14, 2600: 0.15, 2800: 0.17, 3000: 0.19 | |
610 | MERV 11 CLEAN AIR | 200: 0.02, 400: 0.03, 600: 0.05, 800: 0.07, 1000: 0.09, 1200: 0.12, 1400: 0.15, 1600: 0.19, 1800: 0.22, 2000: 0.27 |
810 | 200: 0.02, 400: 0.03, 600: 0.04, 800: 0.06, 1000: 0.08, 1200: 0.11, 1400: 0.13, 1600: 0.16, 1800: 0.19, 2000: 0.22 | |
910 | MERV 11 CLEAN AIR | 200: -, 400: 0.03, 600: 0.05, 800: 0.07, 1000: 0.09, 1200: 0.12, 1400: 0.15, 1600: 0.18, 1800: 0.22, 2000: 0.27 |
201 | EAC MERV 10 | 200: 0.02, 400: 0.04, 600: 0.05, 800: 0.08, 1000: 0.10, 1200: 0.12, 1400: 0.15, 1600: 0.18, 1800: 0.21, 2000: 0.25 |
401 | 200: 0.02, 400: 0.04, 600: 0.05, 800: 0.08, 1000: 0.10, 1200: 0.14, 1400: 0.17, 1600: 0.21, 1800: 0.25, 2000: 0.29 | |
501 | EAC MERV 10 | 200: 0.02, 400: 0.04, 600: 0.05, 800: 0.08, 1000: 0.10, 1200: 0.14, 1400: 0.17, 1600: 0.21, 1800: 0.25, 2000: 0.29 |
* Highest value shown is maximum recommended airflow capacity.
0.3-1.0 Microns | 1.0-3.0 Microns | 3.0-10.0 Microns | |
---|---|---|---|
MERV 16 | 95% | 98% | 99% |
MERV 13 | 63% | 88% | 93% |
MERV 11 | 37% | 67% | 92% |
MERV 10 | 22% | 56% | 92% |
EAC (Model 5000) | 89% | 95% | 98% |
Test Method MERV 10-16 ASHRAE 52.2.2012, EAP AHRI 680-2009
Upgrade Kits & Rails
Model No. | Nominal Size (in inches) | Compatible With | Included Filter | Rails Model Number | Static Pressure Drop (in. w.c.) @ 1200 CFM | Maximum Airflow Capacity (in CFM) |
---|---|---|---|---|---|---|
#1213 | 20 x 25 | Aprilaire/Space-Gard 2200 | 213 | 4893 | 0.15 | 2000 |
#1413 | 16 x 25 | Aprilaire/Space-Gard 2400 | 413 | 4894 | 0.17 | 2000 |
MERV 13
Model No. | Nominal Size (in inches) | Compatible With | Uses Filter Model | Maximum Airflow Capacity (in CFM) |
---|---|---|---|---|
#4893 | 20x25 | Aprilaire/Space-Gard 2200 or 2120 | 210, 213, 213CBN | 2000 |
#4894 | 16x25 | Aprilaire/Space-Gard 2400 or 2140 | 410, 413, 413CBN | 2000 |
#4897 | 16x25 | Models by (but not limited to): Carrier®, Honeywell®, Lennox®, Ultravation®, General®, Trion® | 610, 613 | 2000 |
#4898 | 20x25 | Models by (but not limited to): Carrier®, Honeywell®, Lennox®, Ultravation®, General®, Trion® | 810, 813 | 2000 |
- | 16x20 | Models by (but not limited to): Carrier®, Honeywell®, Lennox®, Ultravation®, General®, Trion® | 110, 113 | 1200 |
- | 20x20 | Models by (but not limited to): Carrier®, Honeywell®, Lennox®, Ultravation®, General®, Trion® | 310, 313 | 1200 |
Replacement Filters
Filter No. | Used with Aprilaire Air Cleaner Models | Nominal Size (in inches) | Static Pressure Drop (in. w.c.) @ 1200 CFM | Maximum Airflow Capacity (in CFM) |
---|---|---|---|---|
201 | Aprilaire/Space-Gard* 2200 | 20 x 25 | 0.12 | 2000 |
401 | Aprilaire/Space-Gard* 2400 | 16 x 25 | 0.14 | 2000 |
*Air Cleaner models no longer available.
Healthy Air Controls
Aprilaire offers a range of thermostats and control modules designed to manage HVAC systems, humidity, air cleaning, and ventilation for optimal indoor air quality and comfort.
Thermostats
Type | Model No. | Stages | Dimensions (W x H x D) | Features |
---|---|---|---|---|
NonProgrammable | 8444 | 1H/1C | 5¼" x 4½" x 1" | Easy to Read Display, Simple Setup, Displays Outdoor Temperature (if equipped), Adjustable Differential, Progressive Recovery, Heat Blast |
NonProgrammable | 8446 | 2H/1C HP | 5¼" x 4½" x 1" | Easy to Read Display, Simple Setup, Displays Outdoor Temperature (if equipped), Adjustable Differential, Progressive Recovery, Heat Blast |
NonProgrammable | 8448 | 2H/2C, 4H/2C HP | 5¼" x 4½" x 1" | Easy to Read Display, Simple Setup, Displays Outdoor Temperature (if equipped), Adjustable Differential, Progressive Recovery, Heat Blast |
Programmable | 8463 | 1H/1C | 6" x 4¹⁵⁄₁₆" x 1¹⁵⁄₁₆" | Easy to Read Display, Simple Setup, Displays Outdoor Temperature (if equipped), Adjustable Differential, Progressive Recovery, Heat Blast, Event-Based™ Air Cleaning, Air Cleaning Notice, Change Filter Alert, Automatic or Manual Humidifier Control, "Humidifier On" Notice, Displays Indoor RH, Energizes HVAC Blower for Humidity Controls, Humidifier with 24 VAC Dry Contact Controls |
Programmable | 8465 | 2H/1C HP | 6" x 4¹⁵⁄₁₆" x 1¹⁵⁄₁₆" | Easy to Read Display, Simple Setup, Displays Outdoor Temperature (if equipped), Adjustable Differential, Progressive Recovery, Heat Blast, Event-Based™ Air Cleaning, Air Cleaning Notice, Change Filter Alert, Automatic or Manual Humidifier Control, "Humidifier On" Notice, Displays Indoor RH, Energizes HVAC Blower for Humidity Controls, Humidifier with 24 VAC Dry Contact Controls |
Programmable | 8466 | 2H/2C, 4H/2C HP | 6" x 4¹⁵⁄₁₆" x 1¹⁵⁄₁₆" | Easy to Read Display, Simple Setup, Displays Outdoor Temperature (if equipped), Adjustable Differential, Progressive Recovery, Heat Blast, Event-Based™ Air Cleaning, Air Cleaning Notice, Change Filter Alert, Automatic or Manual Humidifier Control, "Humidifier On" Notice, Displays Indoor RH, Energizes HVAC Blower for Humidity Controls, Humidifier with 24 VAC Dry Contact Controls |
Programmable with Event-Based™ Air Cleaning | 8476W** 8476 |
2H/2C, 4H/2C HP | 6" x 4¹⁵⁄₁₆" x 1¹⁵⁄₁₆" | Easy to Read Display, Simple Setup, Displays Outdoor Temperature (if equipped), Adjustable Differential, Progressive Recovery, Heat Blast, Event-Based™ Air Cleaning, Air Cleaning Notice, Change Filter Alert, Automatic or Manual Humidifier Control, "Humidifier On" Notice, Displays Indoor RH, Energizes HVAC Blower for Humidity Controls, Humidifier with 24 VAC Dry Contact Controls, Controls Air Cleaner and Humid, Dehumid or Vent |
Programmable Touch Screen | 8600 | 2H/2C, 4H/2C HP | 6" x 4¹⁵⁄₁₆" x 1¹⁵⁄₁₆" | Easy to Read Display, Simple Setup, Displays Outdoor Temperature (if equipped), Adjustable Differential, Progressive Recovery, Heat Blast, Event-Based™ Air Cleaning, Air Cleaning Notice, Change Filter Alert, Automatic or Manual Humidifier Control, "Humidifier On" Notice, Displays Indoor RH, Energizes HVAC Blower for Humidity Controls, Humidifier with 24 VAC Dry Contact Controls, Controls Air Cleaner and Humid, Dehumid or Vent |
Programmable Touch Screen | 8620W** 8620 |
2H/2C, 4H/2C HP | 6" x 4¹⁵⁄₁₆" x 1¹⁵⁄₁₆" | Easy to Read Display, Simple Setup, Displays Outdoor Temperature (if equipped), Adjustable Differential, Progressive Recovery, Heat Blast, Event-Based™ Air Cleaning, Air Cleaning Notice, Change Filter Alert, Automatic or Manual Humidifier Control, "Humidifier On" Notice, Displays Indoor RH, Energizes HVAC Blower for Humidity Controls, Humidifier with 24 VAC Dry Contact Controls, Controls Air Cleaner and Humid, Dehumid or Vent |
Programmable Touch Screen with Humidity Control | 8910W** 8910 |
3H/3C, 4H/2C HP | 7¹⁄₁₀" x 4¹⁷⁄₂₀" x 1" | Easy to Read Display, Simple Setup, Displays Outdoor Temperature (if equipped), Adjustable Differential, Progressive Recovery, Heat Blast, Event-Based™ Air Cleaning, Air Cleaning Notice, Change Filter Alert, Automatic or Manual Humidifier Control, "Humidifier On" Notice, Displays Indoor RH, Energizes HVAC Blower for Humidity Controls, Humidifier with 24 VAC Dry Contact Controls, Controls Air Cleaner and Humid, Dehumid or Vent, Wired Outdoor Temperature Sensor Included |
Programmable Touch Screen with Humidity Control | 8920W** 8920 |
3H/3C, 4H/2C HP | 7¹⁄₁₀" x 4¹⁷⁄₂₀" x 1" | Easy to Read Display, Simple Setup, Displays Outdoor Temperature (if equipped), Adjustable Differential, Progressive Recovery, Heat Blast, Event-Based™ Air Cleaning, Air Cleaning Notice, Change Filter Alert, Automatic or Manual Humidifier Control, "Humidifier On" Notice, Displays Indoor RH, Energizes HVAC Blower for Humidity Controls, Humidifier with 24 VAC Dry Contact Controls, Controls Air Cleaner and Humid, Dehumid or Vent, Wired Outdoor Temperature Sensor Included |
** Wi-Fi, compatible
Zone Control Systems
Type | Model | Description |
---|---|---|
Kits | 6010: 2-Zone Complete Kit* | Black |
Kits | 6015: 2-Zone Complete Kit* | White |
Kits | 6020: 3-Zone Complete Kit* | Black |
Kits | 6025: 3-Zone Complete Kit* | White |
Individual Components | 6030: 2-Zone Base | - |
Individual Components | 6035: 2-Zone Base | - |
Individual Components | 6040: 3-Zone Base | - |
Individual Components | 6045: 3-Zone Base | - |
Individual Components | 6050: Secondary Zone UI | - |
Individual Components | 6055: Secondary Zone UI | - |
* Kits include outdoor temperature sensor along with duct probe
Model | Specifications |
---|---|
6404 | 4 Zone Universal Multistage (Can be expanded to 12 zones with Model 6401) Dimensions: 8⁶⁄₁₀" W x 14²⁵⁄₃₂" H x 1⁴⁵⁄₅₀" D Humidity: 5%-90% RH, non-condensing Operating Temperature: 32°F–158°F Shipping Temperature: -40°F–180°F Voltage: 18-30VAC 50/60 Hz Maximum Current: Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; zone panel consumption: 4VA max Note: Use 18 or 20 AWG solid (non-stranded) wire |
6403 | 3 Zone Universal Multistage + 2 Heat 2 Cool or 4 Heat 2 Cool (Heat Pump) Dimensions: 8⁶⁄₁₀" W x 9³⁄₅₀" H x 1⁴⁵⁄₅₀" D Humidity: 5%-90% RH, non-condensing Operating Temperature: 32°F–158°F Shipping Temperature: -40°F–180°F Voltage: 18-30VAC 50/60 Hz Maximum Current: Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; zone panel consumption: 4VA max Note: Use 18 or 20 AWG solid (non-stranded) wire |
Zoned Comfort Control™ Kits Available: 6404K & 6403K
Model | Specifications |
---|---|
6303 | 3 Zone Heat Pump Dimensions: 8⁶⁄₁₀" W x 9³⁄₅₀" H x 1⁴⁵⁄₅₀" D Humidity: 5% - 90% RH, non-condensing Operating Temperature: 32°F–158°F Shipping Temperature: -40°F–180°F Voltage: 18-30VAC 50/60 Hz Maximum Current: Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; zone panel consumption: 4VA max Note: Use 18 or 20 AWG solid (non-stranded) wire |
6302 | 2 Zone Heat Pump + 2 Heat 1 Cool Single Stage Dimensions: 8⁶⁄₁₀" W x 9³⁄₅₀" H x 1⁴⁵⁄₅₀" D Humidity: 5% - 90% RH, non-condensing Operating Temperature: 32°F–158°F Shipping Temperature: -40°F–180°F Voltage: 18-30VAC 50/60 Hz Maximum Current: Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; zone panel consumption: 4VA max Note: Use 18 or 20 AWG solid (non-stranded) wire |
Zoned Comfort Control™ Kits Available: 6303K & 6302K
Model | Specifications |
---|---|
6203 | 3 Zone Heat/Cool Dimensions: 8⁶⁄₁₀" W x 9³⁄₅₀" H x 1⁴⁵⁄₅₀" D Humidity: 5%–90% RH, non-condensing Operating Temperature: 32°F–158°F Shipping Temperature: -40°F–180°F Voltage: 18-30VAC 50/60 Hz Maximum Current: Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; zone panel consumption: 4VA max Note: Use 18 or 20 AWG solid (non-stranded) wire |
6202 | 2 Zone Heat/Cool + 1 Heat 1 Cool Single Stage Dimensions: 8⁶⁄₁₀" W x 9³⁄₅₀" H x 1⁴⁵⁄₅₀" D Humidity: 5%–90% RH, non-condensing Operating Temperature: 32°F–158°F Shipping Temperature: -40°F–180°F Voltage: 18-30VAC 50/60 Hz Maximum Current: Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; zone panel consumption: 4VA max Note: Use 18 or 20 AWG solid (non-stranded) wire |
Zoned Comfort Control™ Kits Available: 6303K & 6302K ** Zoned Comfort Control Kits include: Zone panel, 6" duct probe and 24V 40VA universal transformer
Zone Dampers
Aprilaire zone dampers are used in conjunction with zone control systems to regulate airflow to specific areas of a building.
Nominal Width (in inches) | Nominal Height (in inches) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
8" (203mm) | 10" (254mm) | 12" (305mm) | 14" (356mm) | 16" (406mm) | 18" (457mm) | 20" (508mm) | 22" (559mm) | 24" (610mm) | 26" (660mm) | 28" (711mm) | 30" (762mm) | |
8" (203mm) | 6721 6721W3 |
6722 6722W3 |
6723 6723W3 |
6724 6724W3 |
6725 6725W3 |
6726 6726W3 |
6727 6727W3 |
6728 6728W3 |
6729 6729W3 |
6730 6730W3 |
6731 6731W3 |
6753 6753W3 |
10" (254mm) | 6732 6732W3 |
6733 6733W3 |
6734 6734W3 |
6735 6735W3 |
6736 6736W3 |
6737 6737W3 |
6738 6738W3 |
6739 6739W3 |
6740 6740W3 |
6741 6741W3 |
6742 6742W3 |
- |
12" (305mm) | 6743 6743W3 |
6744 6744W3 |
6745 6745W3 |
6746 6746W3 |
6747 6747W3 |
6748 6748W3 |
6749 6749W3 |
6750 6750W3 |
6751 6751W3 |
6752 6752W3 |
- | - |
14" (356mm) | 6754 6754W3 |
6755 6755W3 |
6756 6756W3 |
6757 6757W3 |
6758 6758W3 |
6759 6759W3 |
6760 - |
6761 - |
6762 - |
- | - | - |
16" (406mm) | 6763 6763W3 |
6764 6764W3 |
6765 - |
6766 - |
6767 - |
6768 - |
6769 - |
6770 - |
- | - | - | - |
18" (457mm) | 6771 - |
6772 - |
6773 - |
6774 - |
6775 - |
6776 - |
6777 - |
- | - | - | - | - |
20" (508mm) | 6778 - |
6779 - |
6780 - |
6781 - |
6782 - |
6783 - |
- | - | - | - | - | - |
22" (559mm) | 6784 - |
6785 - |
6786 - |
6787 - |
6788 - |
- | - | - | - | - | - | - |
24" (610mm) | 6789 - |
6790 - |
6791 - |
6792 - |
- | - | - | - | - | - | - | - |
26" (660mm) | 6793 - |
6794 - |
6795 - |
- | - | - | - | - | - | - | - | - |
28" (711mm) | 6796 - |
6797 - |
- | - | - | - | - | - | - | - | - | - |
30" (762mm) | 6798 - |
- | - | - | - | - | - | - | - | - | - | - |
Rectangular Damper Dimension = Nominal width + 3.5"
W3 indicates power open/ power closed. 10 day lead time for shaded items.
Nominal Diameter (in inches) | Height (H) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
4" (102mm) | 5" (127mm) | 6" (152mm) | 7" (178mm) | 8" (203mm) | 9" (229mm) | 10" (254mm) | 12" (305mm) | 14" (356mm) | 16" (406mm) | 18" (457mm) | 20" (508mm) | |
Zone Damper (Normally open/power closed) | 6606 6606W3 |
6607 6607W3 |
6608 6608W3 |
6609 6609W3 |
6610 6610W3 |
6612 6612W3 |
6614 6614W3 |
6616 6616W3 |
6618 - |
6620 - |
- | - |
Ventilation Damper (Normally closed/ power opened) | 6506 H: 10¾" |
- | 6508 H: 10¾" |
- | 6510 H: 10¾" |
- | - | - | - | - | - | - |
Barometric Pressure Relief (Air flow activated) | - | - | 6108 H: 10¾" |
- | 6110 H: 10¾" |
- | 6112 H: 12¾" |
6114 H: 14¾" |
6116 H: 16¾" |
- | - | - |
Static Pressure Relief (Power activated) | - | - | 6208 H: 8" |
- | 6210 H: 10" |
- | 6212 H: 12" |
6214 H: 14" |
6216 H: 16" |
6218 H: 18" |
6220 H: 20" |
- |
Round Slip-In Damper (Normally open/power closed) | 6704 W: 3¾" H: 12¾" D: 7³⁄₁₀" |
6705 W: 3¾" H: 12¾" D: 8³⁄₁₀" |
6706 W: 3¾" H: 12¾" D: 9³⁄₁₀" |
6707 W: 3¾" H: 12¾" D: 10³⁄₁₀" |
6708 W: 3¾" H: 12¾" D: 11³⁄₁₀" |
- | 6710 W: 3¾" H: 12¾" D: 13³⁄₁₀" |
- | - | - | - | - |
Round Damper Dimension = Nominal diameter + 4.5"
W3 indicates power open/ power closed. 10 day lead time for shaded items.
Fresh Air Ventilation
Aprilaire ventilation systems, including ventilators and ventilating dehumidifiers, ensure fresh air intake while managing indoor air quality and humidity.
Model | Unit Size | Shipping Weight (lbs.) | Airflow @ 0.2 in. w.c. (CFM) | Description |
---|---|---|---|---|
#E100V + 8190FF | (E100V): W: 14½" H: 23½" L: 48¼" (8190FF): W: 15" H: 14" L: 26" |
82.00 (E100V) 16.80 (8190FF) |
100 (E100V) 150 (8190FF) |
The Ventilating Dehumidifier (Models E100V + 8190FF) brings in fresh air to meet ventilation needs while removing excess humidity from the incoming outdoor air. Fresh air is brought in whenever the HVAC system or dehumidifier is running to meet that need. If the required time is not met through these run cycles, the ventilating dehumidifier will bring in fresh air and remove any excess humidity. |
#8192A | W: 15" H: 14" L: 26" | 82.00 | 150 | The 8192A features an integrated ventilation control. It draws fresh air into the home by energizing its fan and opening its vent damper. If the incoming air is above a set relative humidity percentage point, the outside air is dehumidified by the 8192A. *Dehumidification Capacity 100 Pints Per Day |
#8145 #8145NC #8145K |
(8145): W: 12¼" H: 11¾" L: 23⅖" (8145NC): W: 13⅛" H: 6⁷⁄₁₀" L: 11⁹⁄₁₀" (8145K): W: 10¼" H: 18⅛" D: 10¼" |
15.00 (8145) 14.50 (8145NC) 21.00 (8145K) |
210 | The 8145 or 8142 delivers fresh air into the return or supply duct by energizing its fan and opening its integrated damper. Both models feature an 8120X ventilation controller integrated into the unit. NC models do not include an on-board controller so that ventilation can be controlled via thermostat. The 8145K comes with 8145NC, 8120X control, inlet hood and start collar for adding ventilation to existing homes and systems. |
#8142 #8142NC |
W: 10¼" H: 18⅛" D: 10¼" | 20.50 (8142) 11.50 (8142NC) |
130 | The 8144NC provides continuous low-volume ventilation for smaller single- and multi-family homes. A separate 8120X ventilation controller can be added to set the unit to operate by the controller's Code or Comfort functions. |
#8144NC | W: 10¼" H: 18⅛" D: 10¼" | 11.50 | 130 | The 8144NC provides continuous low-volume ventilation for smaller single- and multi-family homes. A separate 8120X ventilation controller can be added to set the unit to operate by the controller's Code or Comfort functions. |
#8120X | W: 4¹¹⁄₁₀₀" H: 3⁵⁄₁₀" D: 1⁵⁹⁄₁₀₀" | 0.50 | - | The 8120X engages a fan or damper on ventilation solutions to deliver fresh air to return or supply duct. The control can be programmed to deliver the correct amount of fresh air required by code, or it can provide fresh air within set high/low outdoor temperature and indoor RH limits. |
#8126X | W: 10⁸⁄₂₅" H: 10¾" D: 6" | 6.50 | 185 | The 8126X includes a powered damper, ventilation controller, and installation accessories. The controller energizes the damper, mounted on the return side of the HVAC blower. When the HVAC blower energizes, negative pressure draws fresh air into the home. |
#6508KV | W: 8" H: 10¾" D: 12⅓" | 6.00 | 390 | The 6508KV, 6510KV Kitchen Ventilation Kits provide make-up air locally to areas where high-CFM range hoods (typically near 400 CFM or above) are used to prevent home depressurization and its undesired side effects. |
#6510KV | W: 10" H: 10¾" D: 14⅓" | 6.70 | 390 | The 6508KV, 6510KV Kitchen Ventilation Kits provide make-up air locally to areas where high-CFM range hoods (typically near 400 CFM or above) are used to prevent home depressurization and its undesired side effects. |
#8100 | W: 37⅜" H: 20²⁷⁄₄₀" D: 12¾" | 87.00 | 130 | The 8100 draws in fresh outdoor air and exhausts stale indoor air, transferring energy (heating or cooling) between the two air sources, as well as transferring moisture from the higher moisture airstream to the airstream with lower moisture. This creates a balanced airflow and eliminates pressure. A ventilation controller or thermostat (both sold separately) energizes blowers within the ventilator. |
*Dehumidification Capacity 100 Pints Per Day
Accessories
Aprilaire offers various accessories to enhance the functionality and installation of their Healthy Air System components.
Model | Product Description | Unit Size | Type of Wire | Compatible Models |
---|---|---|---|---|
#8051 | Flush Mount Sensor Ideal for residential or light commercial applications where customer requires nothing to be seen on the wall. | Disk: 1½" dia. Friction fit in a 1" opening. Air gap of ¼" required. | 18-24 gauge 2 conductor wire (or more conductors) | 8600, 8620, 8620W, 8910, 8910W, 8920W, 8800, 8820, 8830, 8840 |
#8052 | Outdoor/Duct Sensor Designed for outdoor or duct installation including with use of zone control panels. | Probe: ¼" dia. x 1¾" L Bracket: ¾" x ¾" |
18-24 gauge 2 conductor wire (or more conductors) | All thermostats |
#8053 | Surface Mount Sensor Perfect for light indoor commercial applications to prevent tampering. | W: 3½" H: 2½" D: ⅞" | 18-24 gauge 2 conductor wire (or more conductors) | All thermostats |
#8022 | 3-Wire to 4-Wire Adapter Used to add a wire to a thermostat, fix a broken wire or add a common wire to a 4-wire system. | W: 2⁷⁄₈" H: 1¾" D: 1⁴⁷⁄₅₀" | 18-22 gauge stranded or solid thermostat wire can be used for all wire runs | All thermostats |
#8028 | Damper Power Distribution Panel For applications where needed dampers outnumber control capability of any Aprilaire Zone Control Panel. | W: 10½" H: 5" D: 1⁷⁄₁₀" | - | All zone control panels |
#6401 | Expansion Panel Two-zone expansion panel that supports 2-wire or 3-wire dampers. | W: 10½" H: 5" D: 1⁷⁄₁₀" | - | 6404 With LCD screen |
Automation Modules
Model | Product Description | Unit Size | Compatible Models |
---|---|---|---|
#8081 | Temperature Support Module Averages up to eight temperature locations per thermostat. | W: 3½" H: 2½" D: ⅞" | 8800, 8820, 8830, 8840 |
#8082 | Temperature and RH Support Module Averages four temperatures (on-board or off-board) and four humidity values (on-board only). | W: 3½" H: 2½" D: ⅞" | 8800, 8820, 8830, 8840 |
#8083 | Flush Temperature and RH Support Module Averages four temperature and four RH values. | Disk: 1½" dia. Cylinder Hole: 1" off wall, ¼" air gap | 8800, 8820, 8830, 8840 |
Ventilation Climate Zones & Application Matrix
Managing the quality of ventilated air delivered into the home is critical to providing a healthy indoor environment. The requirements change significantly based on climate. Aprilaire ventilation solutions work with the HVAC equipment to remove moisture, harmful particulates and other contaminants such as VOCs. It's critical to use intelligent ventilation controls and application guidance to properly ventilate rather than relying on exhaust ventilation which simply pulls air through walls.
Climate Zones Map Description: The map displays seven climate zones (1-7) across North America, categorized by factors including mean temperature, warmest month, precipitation, and wet bulb temperature. Zones are labeled as Hot & Moist, Hot & Dry, Warm & Moist, Warm & Dry, Warm & Marine, Mixed & Moist, Mixed & Dry, Mixed & Marine, Cool & Moist, Cool & Dry, Cold & Moist, Cold & Dry, and Extreme Cold & Moist. These zones help determine ventilation strategies based on local environmental conditions.
ZONE | CLIMATE TYPE | MAJOR CITIES | PRIMARY SOLUTION¹ | FRESH AIR DUCTED² | ECONOMY- OR COMFORTFOCUSED SOLUTION | MULTI-FAMILY NEW CONSTRUCTION SOLUTION | ||
---|---|---|---|---|---|---|---|---|
DEHUMIDIFIES INCOMING VENTILATION AIR | MIXES VENTILATION AIR AFTER COOLING OR HEATING | MIXES VENTILATION AIR PRIOR TO COOLING OR HEATING | ||||||
1 | Hot & Moist | Miami | E100V + 8190FF or 8192A | - | - | HVAC Return | 8145 or 8126X | 8144NC |
2 | Hot & Moist | Orlando, Mobile, New Orleans, Houston, Austin, San Antonio | E100V + 8190FF or 8192A | - | - | HVAC Return | 8145 or 8126X | 8144NC |
2 | Hot & Dry | Phoenix, Tucson | - | 8142 | - | HVAC Supply | 8126X | 8144NC |
3 | Warm & Moist | Charlotte, Charleston, Atlanta, Little Rock, Oklahoma City, DFW | E100V + 8190FF or 8192A | - | - | HVAC Supply | 8145 or 8126X | 8144NC |
3 | Warm & Dry | El Paso, Las Vegas, Los Angeles, Sacramento | - | 8142 | - | HVAC Supply | 8145 or 8126X | 8144NC |
3 | Warm & Marine | San Francisco, San Jose | - | 8142 | - | HVAC Return | 8126X | 8144NC |
4 | Mixed & Moist | Philadelphia, Washington DC, Baltimore, Nashville, St. Louis, Wichita, Louisville | - | - | 8145 | HVAC Supply | 8126X | 8144NC |
4 | Mixed & Dry | Albuquerque, Amarillo | - | 8142 | - | HVAC Return | 8126X | 8144NC |
4 | Mixed & Marine | Portland, Seattle | - | 8142 | - | HVAC Return | 8126X | 8144NC |
5 | Cool & Moist | Boston, Pittsburgh, Columbus, Indianapolis, Detroit, Chicago, Des Moines, Omaha | - | - | 8145 | HVAC Return | 8126X | 8144NC |
5 | Cool & Dry | Denver, Salt Lake City, Boise, Reno | - | - | 8145 | HVAC Return | 8126X | 8144NC |
6 | Cold & Moist | Toronto, Vancouver, Milwaukee, Madison, Minneapolis-St Paul, Sioux Falls | - | - | 8145 | HVAC Return | 8126X | 8144NC |
6 | Cold & Dry | Helena, Cheyenne | - | - | 8145 | HVAC Return | 8126X | 8144NC |
7 | Extreme Cold & Moist | Fargo, Duluth, Calgary, Edmonton | - | - | 8145 | HVAC Return | 8126X | 8144NC |
¹ Primary Aprilaire recommended supply ventilation solution for optimal performance and building code adherence.
² HVAC application considerations based upon moist versus dry air, and proper mixing into the ductwork.