AprilAire All Product Guide
Quick Reference | January 2022
Healthy Air in every home.
AprilAire Healthy Air Solutions
Legend: ? Radon | ? Unfiltered air | ?️ Ventilated air | ? Dry air | ♨️ Humid air | ?️ Temperature controlled spaces
A diagram illustrates a house with different zones representing radon presence, unfiltered air, ventilated air, dry air, humid air, and temperature-controlled spaces. Arrows indicate airflow and temperature distribution within the home, showing temperatures of 72°F in some rooms and 68°F in others.
AprilAire provides professional-grade Healthy Air solutions. Our mission is to enhance people's health by improving the air in their homes. Healthy Air is essential to living a healthy lifestyle and improving overall well-being. We are inspired by the needs of consumers and the expertise of professional contractors to create, design, and build innovative solutions.
AprilAire is Healthy Air.
Features: 5-year warranty on all installed products, Designed & Engineered in the USA.
Radon Mitigation
Mitigation Fans
AprilAire Radon Mitigation Fans are specifically designed for radon mitigation, providing superb performance and ultra-quiet operation.
Features:
- Energy efficient
- Ultra-quiet operation
- Meets all electrical code requirements
- Housing that stays white
- Water-hardened motorized impeller
- Seams sealed to inhibit radon leakage (ARN15F/ARN25F double snap sealed)
- ETL Listed - for indoor or outdoor use
- Thermally protected motor
- Rated for commercial and residential use
- Patent pending design
- Optimal for moderate to tight soils (ARNHPF Only)
- Technology to inhibit radon and soil gas leakage
- ETL listed by Intertek to UL507 and CSA C22.2 Standards
MODEL | FAN DUCT DIAMETER | RECOMMENDED WATTS | MAXIMUM OPERATING PRESSURE "WC | 9.7" | 11.75" | 11.9" | 8.5" | 8.6" | 10.9" | |||
---|---|---|---|---|---|---|---|---|---|---|---|---|
ARN15F | 4" | 41-72 | 1.7 | 166 | 126 | 82 | 41 | 3 | - | |||
ARN25F | 6" | 70-170 | 2.3 | 375 | 340 | 282 | 204 | 140 | 70 | |||
ARNHPF | 3" | 70-170 | 4.0 | - | 110 | 97 | 88 | 79 | 68 | 54 | 36 | 14 |
TYPICAL CFM vs. STATIC PRESSURE WC:
0" | 0.2" | 0.5" | 1.0" | 1.5" | 2.0" | 2.5" | 3.0" | 3.5" | 4.0" | |
---|---|---|---|---|---|---|---|---|---|---|
ARN15F | 166 | 126 | 82 | 41 | 3 | - | - | - | - | - |
ARN25F | 375 | 340 | 282 | 204 | 140 | 70 | - | - | - | - |
ARNHPF | 110 | 97 | 88 | 79 | 68 | 54 | 36 | 14 | - | - |
Mitigation Kits
Kits include: fan, manometer, couplings, and radon system alarm.
Application | RRNC 2.0 Radon Fan Type | Dimensions DxH | Color | Fan Duct Diameter | Pressure |
---|---|---|---|---|---|
ARN15K (Slab size <1500 sq. ft.) | RF1, RF2 | 9.7" x 8.5" | White | 4" | 1.7" WC |
ARN25K (Slab size 1500-2500 sq. ft.) | - | 11.75" x 8.6" | White | 6" | 2.3" WC |
ARNHPK (Moderate to Tight Soil) | - | 11.9" x 10.9" | White | 3" | 4.0" WC |
Radon Accessories
ACCESSORY | DESCRIPTION |
---|---|
Manometer P/N ARN05M | Mounts to the outside of PVC pipe on a radon mitigation system and measures vacuum pressure in real time, helping to indicate potential issues with the fan. It can serve as a secondary indicator that vacuum pressure has changed in the event of a system alarm going off, helping to confirm that it's not a false alarm. |
Transition Fitting P/N ARNTF4 | Consolidates the number of fittings needed in outdoor radon mitigation system installations. Connects a 4" fan pipe to a 4" exhaust pipe with a weir (not included) for capturing and draining condensate. Weir is included in the Condensate Bypass Kit. |
Condensate Bypass Kit P/N ARNCBK | This kit is designed to drain condensation around the fan in outdoor installs. |
Radon-T Fitting P/N ARNSIT | Designed for use in adding radon mitigation to new construction and crawl spaces. Provides 4-way airflow, allowing moisture and soil gases to be drawn from all angles. |
Radon System Alarm P/N ARNALM | Advanced vacuum monitoring device utilizing piezoresistive pressure sensor (PPS) technology. It provides homeowners with an easy-to-read, easy-to-use system alarm that requires no interpretation. |
Warranty: 5-year warranty on all AprilAire Radon Mitigation Fans.
Humidity Control
Humidifiers
Humidifiers - Part of the AprilAire Healthy Air System.
HUMIDIFIERS | TYPE OF HUMIDIFICATION | UNIT SIZE (WIDTH X HEIGHT X DEPTH) | PLENUM OPENING | CAPACITY (GPD= GALLONS PER DAY) | ELECTRICAL DATA | WATER PANEL/CANISTER |
---|---|---|---|---|---|---|
#800, #801 | Steam | - | - | 11.5 GPD | 120V 60HZ, 11.5 AMP | - |
#865, #866*** | Ductless Steam | Fan Pack: 14" x 6 29/32" x 3 15/16" Finished Grille: 16 3/16" x 9" x 1 3/32" |
- | 16.0 GPD | 120V 60HZ, 16.0 AMP | - |
#700*, #700M** | Fan Powered Evaporative | 15 29/32" x 18" x 10 11/32" | - | 20.5 GPD / 30.0 GPD | 208V 60HZ, 11.5 AMP / 16.0 AMP | 80 |
#600*, #600M** | Large Bypass Evaporative | 15 3/8" x 15 3/4" x 10 1/4" 6" dia. round opening |
W: 10" H: 12 3/4" |
18 GPD | 120V 60HZ, 0.8 AMP | 35 |
#500*, #500M** | Small Bypass Evaporative | 15 5/8" x 13" x 10 1/4" 6" dia. round opening |
W: 9 1/2" H: 9 1/2" |
12 GPD | 24V 60HZ, 0.5 AMP | 10 |
#400*, #400M** | Water Saver Bypass Evaporative | 15 3/8" x 15 3/4" x 10 1/4"* 6" dia. round opening |
W: 10" H: 12 3/4" |
17 GPD | 24V 60HZ, 0.5 AMP | 45 |
#300 | Self-Contained Evaporative | 14 3/8" x 12 1/2" x 22 3/32" | - | 13 GPD | 120V 60HZ, 0.7 AMP | 35 |
Humidifier Sizing Guidelines (GPD Needed Per Square Foot** Based on Building Structure Tightness):
STRUCTURE TIGHTNESS | VOLUME OF BUILDING (FT3) | BUILDING FLOOR AREA (FT2) WITH 8 FT CEILINGS | |||||
---|---|---|---|---|---|---|---|
8000 | 12000 | 16000 | 20000 | 24000 | 32000 | 40000 | |
1000 Ft2 | 1500 Ft2 | 2000 Ft2 | 2500 Ft2 | 3000 Ft2 | 4000 Ft2 | 5000 Ft2 | |
Tight | 3.3 GPD | 5.0 GPD | 6.7 GPD | 8.3 GPD | 10.0 GPD | 13.4 GPD | 16.7 GPD |
Average | 6.7 GPD | 10.0 GPD | 13.4 GPD | 16.7 GPD | 20.0 GPD | 26.7 GPD | 33.4 GPD |
Loose | 10.0 GPD | 15.0 GPD | 20.0 GPD | 25.0 GPD | 30.1 GPD | 40.1 GPD | 50.1 GPD |
Regional Humidifier Applications: AprilAire humidifiers can be installed on many types of HVAC equipment and controlled for optimal humidity. This guide assists in selecting the appropriate product based on geography and heating equipment. The portfolio includes evaporative flow-through, fan-powered, and steam humidifiers. Considerations include plenum temperature, airflow, and run time. AprilAire's control strategy maximizes humidifier run time/capacity. Automatic controls have an integrated blower activation relay. Installations with manual controls can increase capacity by setting the thermostat fan to 'ON'. Plumb evaporative humidifiers to hot water where recommended.
Climate Zones Map Description: A map of the United States is divided into climate zones (e.g., Mountain, Midwest/Northeast, Desert (Southwest), Mid-Atlantic/Mid-Southern, South) with color coding.
Dehumidifiers
Dehumidifiers - Part of the AprilAire Healthy Air System.
DEHUMIDIFIERS | UNIT SIZE (WIDTH X HEIGHT X LENGTH) | CAPACITY (PPD = PINTS PER DAY) | AIRFLOW @ VARYING E.S.P. (EXTERNAL STATIC PRESSURE - DRY COIL) | UNIT WEIGHT (LBS.) |
---|---|---|---|---|
#E070 | 12 1/2" x 12 1/2" x 25" | 70 ppd | 200 CFM @ 0.0" w.c. 170 CFM @ 0.2" w.c. 140 CFM @ 0.4" w.c. |
56 |
#E080, #E080H1 | 14" x 15" x 26" | 80 ppd | 185 CFM @ 0.0" w.c. 135 CFM @ 0.2" w.c. 85 CFM @ 0.4" w.c. |
63 |
#E100, #E100C2 | 14" x 15" x 26" | 100 ppd | 280 CFM @ 0.0" w.c. 245 CFM @ 0.2" w.c. 210 CFM @ 0.4" w.c. |
64 |
#E130, #E130H1, #E130C2 | 19 1/2" x 18 1/2" x 30" | 130 ppd | 310 CFM @ 0.0" w.c. 270 CFM @ 0.2" w.c. 225 CFM @ 0.4" w.c. |
98 |
Dehumidifier Sizing Guidelines: Recommended home floor area (ft²) is for sizing guidance only. Actual size depends on location, ventilation rate, occupant habits, AC system moisture removal, and environmental conditions. Values are for the most humid locations within each region. Use the Dehumidifier Selection Assistant at AprilAirepartners.com/dsa for on-demand recommendations.
MODEL E080 | MODEL E100 | MODEL E130 | ||||
---|---|---|---|---|---|---|
LOOSE | TIGHT | LOOSE | TIGHT | LOOSE | TIGHT | |
REGION A | 3,200 Ft² | 4,400 Ft² | 4,000 Ft² | 5,500 Ft² | 5,200 Ft² | 7,200 Ft² |
REGION B | 2,600 Ft² | 3,900 Ft² | 3,200 Ft² | 5,000 Ft² | 3,900 Ft² | 6,500 Ft² |
REGION C | 1,600 Ft² | 2,300 Ft² | 2,000 Ft² | 3,000 Ft² | 2,300 Ft² | 3,600 Ft² |
Air Filtration
Air Cleaners
Air Cleaners - Part of the AprilAire Healthy Air System.
AIR CLEANERS | NOMINAL SIZE (IN INCHES) | CABINET SIZE (IN INCHES) | SHIPPING WEIGHT (LBS) | INCLUDED FILTER | COMPATIBLE FILTERS* |
---|---|---|---|---|---|
#2216, #2416, #2516 | 20 x 25 16 x 25 31 x 28 |
W: 6 3/4" H: 22 1/16" D: 27 3/8" W: 6 3/4" H: 17 3/4" D: 30 1/16" W: 6 3/4" H: 31" D: 30 1/16" |
20 19.25 24.9 |
MERV 16 MERV 13 MERV 11 |
213CBN, 213, 210 413CBN, 413, 410 513CBN, 513, 510 |
#2210 | 20 x 25 | W: 6 3/4" H: 22 1/16" D: 27 3/8" | 19 | MERV 13 | 216, 213CBN, 210 |
#2310 | 20 x 20 | W: 6 3/4" H: 20 3/8" D: 22 1/16" | 17 | MERV 11 | 313 |
#2410 | 16 x 25 | W: 6 3/4" H: 17 3/4" D: 30 1/16" | 19 | MERV 11 | 416, 413CBN, 410 |
#1110, #1210, #1310, #1410, #1510, #1910, #1610, #1620 | 16 x 20 20 x 25 20 x 20 16 x 25 31 x 28 25 x 20 16 x 25 20 x 25 |
W: 6 3/4"H: 17 3/4" D: 22 1/16" W: 6 3/4" H: 22 1/16" D: 27 3/8" W: 6 3/4" H: 20 3/8" D: 22 1/16" W: 6 3/4" H: 17 3/4" D: 30 1/16" W: 6 3/4" H: 31" D: 30 1/16" W: 6 3/4" H: 25 1/16" D: 22 1/16" W: 15 11/16" H: 17 13/16" D: 30 3/16" W: 15 11/16" H: 22 1/8" D: 27 3/8" |
13 20 15 19 28 18 31 32.4 |
MERV 11 MERV 13 MERV 13 MERV 13 MERV 13 MERV 13 MERV 13 MERV 13 |
113, 213, 213CBN, 210 216, 213CBN, 213 313, 413, 410 416, 413CBN, 413 513CBN, 513, 510 913 410 210 |
ELECTRONIC AIR CLEANER #5000 | 16 x 25 | W: 12" H (front): 18 3/8" H (back): 17 3/4" D: 31" |
35 | 501 | - |
Filter Grille Air Cleaners**
APRILAIRE FILTER GRILLE | NOMINAL SIZE (IN INCHES) | FILTER MODEL | SHIPPING WEIGHT |
---|---|---|---|
1625FG11 | 16 x 25 | 610 | 16 lbs. |
1625FG13 | 16 x 25 | 613 | 16 lbs. |
2025FG11 | 20 x 25 | 810 | 18 lbs. |
2025FG13 | 20 x 25 | 813 | 18 lbs. |
Air Filters
Air Filters - Part of the AprilAire Healthy Air System.
Pressure Drop Chart
STATIC PRESSURES AT VARIABLE CFM (IN. W.C.)*
FILTER NO. | 200 | 400 | 600 | 800 | 1000 | 1200 | 1400 | 1600 | 1800 | 2000 | 2200 | 2400 | 2600 | 2800 | 3000 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MERV 16 (ALLERGY & ASTHMA) | 0.06 | 0.09 | 0.13 | 0.17 | 0.23 | 0.29 | 0.36 | - | - | - | - | - | - | - | - |
416 | 0.07 | 0.10 | 0.13 | 0.18 | 0.24 | 0.31 | - | - | - | - | - | - | - | - | - |
516 | 0.04 | 0.05 | 0.07 | 0.09 | 0.10 | 0.13 | 0.15 | 0.18 | 0.21 | 0.24 | 0.27 | 0.31 | - | - | - |
MERV 13 (HEALTHY HOME) | 0.03 | 0.07 | 0.11 | 0.16 | 0.22 | 0.29 | - | - | - | - | - | - | - | - | - |
213 | 0.02 | 0.04 | 0.06 | 0.09 | 0.12 | 0.15 | 0.19 | 0.23 | 0.27 | 0.31 | - | - | - | - | - |
313 | 0.03 | 0.05 | 0.09 | 0.13 | 0.17 | 0.23 | - | - | - | - | - | - | - | - | - |
413 | 0.02 | 0.05 | 0.07 | 0.10 | 0.14 | 0.17 | 0.22 | 0.26 | 0.31 | 0.37 | - | - | - | - | - |
513 | 0.01 | 0.02 | 0.04 | 0.05 | 0.05 | 0.07 | 0.08 | 0.10 | 0.11 | 0.13 | 0.15 | 0.17 | 0.18 | 0.20 | 0.23 |
613 | 0.02 | 0.05 | 0.07 | 0.10 | 0.14 | 0.17 | 0.22 | 0.26 | 0.31 | 0.37 | - | - | - | - | - |
813 | 0.02 | 0.04 | 0.06 | 0.09 | 0.12 | 0.15 | 0.19 | 0.23 | 0.27 | 0.31 | - | - | - | - | - |
913 | - | 0.04 | 0.07 | 0.10 | 0.13 | 0.17 | 0.22 | 0.25 | 0.30 | 0.35 | - | - | - | - | - |
213CBN | 0.04 | 0.07 | 0.10 | 0.13 | 0.17 | 0.21 | 0.25 | 0.30 | 0.35 | - | - | - | - | - | - |
413CBN | 0.04 | 0.07 | 0.10 | 0.14 | 0.19 | 0.24 | 0.29 | 0.36 | 0.43 | - | - | - | - | - | - |
513CBN | 0.03 | 0.04 | 0.05 | 0.07 | 0.08 | 0.10 | 0.12 | 0.15 | 0.17 | 0.20 | 0.22 | 0.25 | 0.29 | 0.32 | - |
MERV 11 (CLEAN AIR) | 0.02 | 0.05 | 0.06 | 0.10 | 0.14 | 0.20 | - | - | - | - | - | - | - | - | - |
210 | 0.02 | 0.03 | 0.04 | 0.06 | 0.08 | 0.11 | 0.13 | 0.16 | 0.19 | 0.22 | - | - | - | - | - |
310 | 0.02 | 0.04 | 0.06 | 0.10 | 0.14 | 0.19 | - | - | - | - | - | - | - | - | - |
410 | 0.02 | 0.03 | 0.05 | 0.07 | 0.09 | 0.12 | 0.15 | 0.19 | 0.22 | 0.27 | - | - | - | - | - |
510 | 0.02 | 0.02 | 0.03 | 0.04 | 0.04 | 0.05 | 0.06 | 0.07 | 0.09 | 0.10 | 0.12 | 0.14 | 0.15 | 0.17 | 0.19 |
610 | 0.02 | 0.03 | 0.05 | 0.07 | 0.09 | 0.12 | 0.15 | 0.19 | 0.22 | 0.27 | - | - | - | - | - |
810 | 0.02 | 0.03 | 0.04 | 0.06 | 0.08 | 0.11 | 0.13 | 0.16 | 0.19 | 0.22 | - | - | - | - | - |
910 | - | 0.03 | 0.05 | 0.07 | 0.09 | 0.12 | 0.15 | 0.18 | 0.22 | 0.27 | - | - | - | - | - |
201 | 0.02 | 0.04 | 0.05 | 0.08 | 0.10 | 0.12 | 0.15 | 0.18 | 0.21 | 0.25 | - | - | - | - | - |
401 | 0.02 | 0.04 | 0.05 | 0.08 | 0.10 | 0.14 | 0.17 | 0.21 | 0.25 | 0.29 | - | - | - | - | - |
501 | 0.02 | 0.04 | 0.05 | 0.08 | 0.10 | 0.14 | 0.17 | 0.21 | 0.25 | 0.29 | - | - | - | - | - |
*Highest value shown is maximum recommended airflow capacity.
Removal Efficiency
0.3-1.0 MICRONS | 1.0-3.0 MICRONS | 3.0-10.0 MICRONS | |
---|---|---|---|
MERV 16 | 95% | 98% | 99% |
MERV 13 | 63% | 88% | 93% |
MERV 11 | 37% | 67% | 92% |
MERV 10 | 22% | 56% | 92% |
EAC (MODEL 5000) | 89% | 95% | 98% |
Test Method: MERV 10-16 - ASHRAE 52.2.2012, EAC - AHRI 680-2009
Upgrade Kits
UPGRADE KITS | NOMINAL SIZE (IN INCHES) | COMPATIBLE WITH | INCLUDED FILTER | RAILS MODEL NUMBER | STATIC PRESSURE DROP (IN. W.C.) @ 1200 CFM | MAXIMUM AIRFLOW CAPACITY (IN CFM) |
---|---|---|---|---|---|---|
#1213 | 20 x 25 | AprilAire or Space-Gard 2200 | 213 | 4893 | 0.15 | 2000 |
#1413 | 16 x 25 | AprilAire or Space-Gard 2400 | 413 | 4894 | 0.17 | 2000 |
UPGRADE RAILS | Nominal Size (in inches) | Compatible With | Uses Filter Model | Maximum Airflow Capacity (in CFM) |
---|---|---|---|---|
#4893 | 20x25 | 2200 Space-Gard Units | 210, 213, 213CBN | 2000 |
#4894 | 16x25 | 2400 Space-Gard Units | 410, 413, 413CBN | 2000 |
#4897 | 16x25 | 16x25 Competitive Cabinets | 610, 613 | 2000 |
#4898 | 20x25 | 20x25 Competitive Cabinets | 810, 813 | 2000 |
16x20 | 16x20 Competitive Cabinets | 110, 113 | 1200 | |
20x20 | 20x20 Competitive Cabinets | 310, 313 | 1200 |
Replacement Filters
FILTER NO. | USED WITH APRILAIRE AIR CLEANER MODELS | NOMINAL SIZE (IN INCHES) | STATIC PRESSURE DROP (IN. W.C.) @ 1200 CFM | MAXIMUM AIRFLOW CAPACITY (IN CFM) |
---|---|---|---|---|
201 | AprilAire/Space-Gard* 2200 | 20 x 25 | 0.12 | 2000 |
401 | AprilAire/Space-Gard* 2400 | 16 x 25 | 0.14 | 2000 |
501 | - | - | - | - |
*Air Cleaner models no longer available.
Healthy Air Controls
Thermostats
Thermostats - Part of the AprilAire Healthy Air System.
RESIDENTIAL MODEL NO. | STAGES | Non-Programmable | Programmable | Programmable with Event-Based™ Air Cleaning | Programmable Touch Screen | IAQ Control | Touch Screen Equipment Control Module |
---|---|---|---|---|---|---|---|
HOME AUTOMATION MODEL NO. | 83/5" x 93/5" x 19/10" | ||||||
8444 - 1H/1C 8446 - 2H/1C HP 8448 - 2H/2C, 4H/2C HP |
✔️ | ||||||
8463 - 1H/1C 8465 - 2H/1C HP 8466 - 2H/2C, 4H/2C HP |
✔️ | ||||||
8476W** 8476 - 2H/2C, 4H/2C HP |
✔️ | ||||||
8600 - 2H/2C, 4H/2C HP | ✔️ | ||||||
8620W** 8620 - 2H/2C, 4H/2C HP |
✔️ | ||||||
8910W** 8910 - 3H/3C, 4H/2C HP 8920W** - 3H/3C, 4H/2C HP |
✔️ | ||||||
8810, 8800, 8820, 8830, 8840 |
Features: Easy to Read Display ✔️, Simple Setup ✔️, Displays Outdoor Temperature (if equipped) ✔️, Adjustable Temperature Differential ✔️, Progressive Recovery ✔️, Heat Blast ✔️, Event-Based™ Air Cleaning ✔️.
Control Functions: Air Cleaning Notice ✔️, Change Filter Alert ✔️, Automatic or Manual Humidifier Control ✔️, "Humidifier On" Notice ✔️, Displays Indoor RH ✔️, Energizes HVAC Blower for Humidity ✔️, Controls Humidifier with 24 VAC Dry Contact ✔️, Controls Whole-Home Dehumidifier ✔️, Controls A/C Equipment for Dehumidification ✔️, Displays Indoor RH ✔️, "Dehumidifier On" Notice ✔️, Energizes HVAC Blower for Dehumidification ✔️, Controls Dehumidifier with 24 VAC Dry Contact ✔️, Programmable for Timed Ventilation ✔️, Programmable for ASHRAE 62.2 Ventilation ✔️, Configurable Temperature and Humidity Limits ✔️, "Ventilation On" Notice ✔️.
Product Configuration: Controls Air Cleaner and Humid or Dehumid or Vent ✔️, Controls Air Cleaner and Humid, Dehumid and Vent ✔️, Wired Outdoor Temperature Sensor Included ✔️, Two-Part Design - Only 3 Wires to the Living Space ✔️.
Zone Control Systems
6000 SERIES PRODUCT CONFIGURATIONS
KITS | BLACK | WHITE |
---|---|---|
2-ZONE | Model 6010: 2-Zone Complete Kit* | Model 6015: 2-Zone Complete Kit* |
3-ZONE | Model 6020: 3-Zone Complete Kit* | Model 6025: 3-Zone Complete Kit* |
INDIVIDUAL COMPONENTS | BLACK | WHITE |
---|---|---|
Model 6030: 2-Zone Base Model 6040: 3-Zone Base Model 6050: Secondary Zone UI |
Model 6035: 2-Zone Base Model 6045: 3-Zone Base Model 6055: Secondary Zone UI |
* Kits include outdoor temperature sensor along with duct probe.
Zone Control Panels
MODEL | SPECIFICATIONS |
---|---|
UNIVERSAL 6404 Zone Universal Multistage (Can be expanded to 12 zones with Model 6401) 6403 Zone Universal Multistage 2 Heat 2 Cool or 4 Heat 2 Cool (Heat Pump) Compatible with Model 8056 wireless outdoor sensor |
Overall Dimensions: 8 63/100" W x 14 18/25" H x 1 43/50" D Humidity: 5%-90% RH, non-condensing Operating Temperature: 32°F-158°F Shipping Temperature: -40°F-180°F Voltage: 18-30VAC 50/60 Hz Maximum Current: Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; zone panel consumption: 4VA max. Note: Use 18 or 20 AWG solid (non-stranded) wire. ZONED COMFORT CONTROL™ KITS** AVAILABLE: 6404K & 6403K |
HEAT PUMP ONLY 6303 Zone Heat Pump 6302 Zone Heat Pump 2 Heat 1 Cool Single Stage |
Overall Dimensions: 8 63/100" W x 9 33/50" H x 1 43/50" D Humidity: 5% - 90% RH, non-condensing Operating Temperature: 32°F-158°F Shipping Temperature: -40°F-180°F Voltage: 18-30VAC 50/60 Hz Maximum Current: Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; zone panel consumption: 4VA max. Note: Use 18 or 20 AWG solid (non-stranded) wire. ZONED COMFORT CONTROL™ KITS** AVAILABLE: 6303K & 6302K |
CONVENTIONAL ONLY 6203 Zone Heat/Cool 6202 Zone Heat/Cool 1 Heat 1 Cool Single Stage |
Overall Dimensions: 8 63/100" W x 9 33/50" H x 1 43/50" D Humidity: 5%-90% RH, non-condensing Operating Temperature: 32°F-158°F Shipping Temperature: -40°F-180°F Voltage: 18-30VAC 50/60 Hz Maximum Current: Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; zone panel consumption: 4VA max. Note: Use 18 or 20 AWG solid (non-stranded) wire. ZONED COMFORT CONTROL™ KITS** AVAILABLE: 6303K & 6302K |
** Zoned Comfort Control Kits include: Zone panel, 6" duct probe and 24V 40VA universal transformer.
Zone Dampers
Rectangular Dampers
NOMINAL WIDTH (IN INCHES) | 8" (203MM) | 10" (254MM) | 12" (305MM) | 14" (356MM) | 16" (406MM) | 18" (457MM) | 20" (508MM) | 22" (559MM) | 24" (610MM) | 26" (660MM) | 28" (711MM) | 30" (762MM) |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Side Mount (Motor mounted on short dimension) W3 indicates power open/power closed |
6721 6721W3 |
6722 6722W3 |
6723 6723W3 |
6724 6724W3 |
6725 6725W3 |
6726 6726W3 |
6727 6727W3 |
6728 6728W3 |
6729 6729W3 |
6730 6730W3 |
6731 6731W3 |
6753 6753W3 |
Bottom Mount (Motor mounted on long dimension) |
6732 6732W3 |
6733 6733W3 |
6734 6734W3 |
6735 6735W3 |
6736 6736W3 |
6737 6737W3 |
6738 6738W3 |
6739 6739W3 |
6740 6740W3 |
6741 6741W3 |
6742 6742W3 |
|
NOMINAL HEIGHT (IN INCHES) | 10 3/4" | 10 3/4" | 10 3/4" | 10 3/4" | 10 3/4" | 12 3/4" | 14 3/4" | 16 3/4" | 19 31/50" | 22" | ||
6743 6743W3 |
6744 6744W3 |
6745 6745W3 |
6746 6746W3 |
6747 6747W3 |
6748 6748W3 |
6749 6749W3 |
6750 | 6751 | 6752 | |||
6754 6754W3 |
6755 6755W3 |
6756 6756W3 |
6757 6757W3 |
6758 6758W3 |
6759 6759W3 |
6760 | 6761 | 6762 | ||||
6763 6763W3 |
6764 6764W3 |
6765 6765W3 |
6766 6766W3 |
6767 6767W3 |
6768 6768W3 |
6769 6769W3 |
6770 | 6771 | 6772 | 6773 | 6774 | |
6775 | 6776 | 6777 |
* Rectangular Damper Dimension = Nominal width + 3.5"
Round Dampers
NOMINAL DIAMETER (IN INCHES) | 4" (102MM) | 5" (127MM) | 6" (152MM) | 7" (178MM) | 8" (203MM) | 9" (229MM) | 10" (254MM) | 12" (305MM) | 14" (356MM) | 16" (406MM) | 18" (457MM) | 20" (508MM) |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Zone Damper (Normally open/power closed) W3 indicates power open/power closed |
6606 6606W3 |
6607 6607W3 |
6608 6608W3 |
6609 6609W3 |
6610 6610W3 |
6612 6612W3 |
6614 6614W3 |
6616 6616W3 |
6618 | 6620 | ||
NOMINAL HEIGHT (IN INCHES) | 10 3/4" | 10 3/4" | 10 3/4" | 10 3/4" | 10 3/4" | 12 3/4" | 14 3/4" | 16 3/4" | 19 31/50" | 22" | ||
6506 | 6508 | 6510 | ||||||||||
Ventilation Damper (Normally closed/power opened) |
6108 | 6110 | 6112 | 6114 | 6116 | |||||||
Barometric Pressure Relief (Air flow activated) |
6208 | 6210 | 6212 | 6214 | 6216 | 6218 | 6220 | |||||
Static Pressure Relief (Power activated) |
6704 | 6705 | 6706 | 6707 | 6708 | 6710 | ||||||
Round Slip-In Damper (Normally open/power closed) |
W: 3 4/5" H: 12 3/5" D: 7 3/10" |
W: 3 4/5" H: 12 3/5" D: 8 3/10" |
W: 3 4/5" H: 12 3/5" D: 9 3/10" |
W: 3 4/5" H: 12 3/5" D: 10 3/10" |
W: 3 4/5" H: 12 3/5" D: 11 3/10" |
W: 3 4/5" H: 12 3/5" D: 13 3/10" |
* Round Damper Dimension = Nominal diameter + 4.5"
Fresh Air Ventilation
Ventilators and Ventilating Dehumidifiers
Part of the AprilAire Healthy Air System.
VENTILATION SYSTEMS | UNIT SIZE | SHIPPING WEIGHT (LBS.) | AIRFLOW @ 0.2 IN. W.C. (CFM) | DESCRIPTION |
---|---|---|---|---|
VENTILATING DEHUMIDIFIERS | ||||
#E100V + 8190FF | W: 14 1/2" H: 23 1/2" L: 48 1/4" |
82.00 (E100V) 16.80 (8190FF) |
150 | The Ventilating Dehumidifier (Models E100V + 8190FF) brings in fresh air to meet ventilation needs while removing excess humidity from the incoming outdoor air. Fresh air is brought in whenever the HVAC system or dehumidifier is running to meet that need. If the required time is not met through these run cycles, the ventilating dehumidifier will bring in fresh air and remove any excess humidity. |
#8192A | W: 15" H: 14" L: 26" |
82.00 | 245 | The 8192A features an integrated ventilation control. It draws fresh air into the home by energizing its fan and opening its vent damper. If the incoming air is above a set relative humidity percentage point, the outside air is dehumidified by the 8192A. |
FRESH AIR VENTILATORS | ||||
#8145A, #8145NC, #8145K #8142A, #8142NC |
W: 12 1/4" H: 11 3/4" L: 23 2/5" W: 13 1/5" H: 6 7/10" L: 11 9/10" |
15.00 (8145A) 14.50 (8145NC) 21.00 (8145K) 11.50 10.75 |
210 | The 8145A or 8142A delivers fresh air into the return or supply duct by energizing its fan and opening its integrated damper. Both models feature an 8120A ventilation controller integrated into the unit. NC models do not include an on-board controller so that ventilation can be controlled via thermostat. The 8145K comes with 8145NC, 8120A control, inlet hood and start collar for adding ventilation to existing homes and systems. |
#8144NC | W: 10 1/4" H: 18 1/8" D: 10 1/4" | 20.50 | 130 | The 8144NC provides continuous low-volume ventilation for smaller single- and multi-family homes. A separate 8120A ventilation controller can be added to set the unit to operate by the controller's Code or Comfort functions. |
#8120A (VENTILATION CONTROLLER) | W: 4 11/100" H: 3 3/5" D: 1 59/100" | 0.50 | - | The 8120A engages a fan or damper on ventilation solutions to deliver fresh air to return duct. It can provide fresh air within set high/low outdoor temperature and indoor RH limits. |
#8126A (VENTILATION SYSTEM) | W: 10 8/25" H: 10 3/4" D: 6" | 6.50 | - | The 8126A includes a powered damper, ventilation controller, and installation accessories. The controller energizes the damper, mounted on the return side of the HVAC blower. When the HVAC blower energizes, negative pressure draws fresh air into the home. |
KITCHEN VENTILATION KITS #KV08 #KV10 |
W: 8" H: 10 3/4" D: 12 1/3" W: 10" H: 10 3/4" D: 14 1/3" |
6.00 6.70 |
185 390 |
The KV08, KV10 Kitchen Ventilation Kits provide make-up air locally to areas where high-CFM range hoods (typically near 400 CFM or above) are used to prevent home depressurization and its undesired side effects. |
FRESH AIR EXCHANGER (ERV) #8100 |
W: 37 3/8" H: 20 23/40" D: 12 3/4" | 87.00 | 130 | The 8100 draws in fresh outdoor air and exhausts stale indoor air, transferring energy (heating or cooling) between the two air sources, as well as transferring moisture from the higher moisture airstream to the airstream with lower moisture. This creates a balanced airflow and eliminates pressure. A ventilation controller or thermostat (both sold separately) energizes blowers within the ventilator. |
Accessories
ACCESSORIES | PRODUCT DESCRIPTION | UNIT SIZE | TYPE OF WIRE | COMPATIBLE MODELS |
---|---|---|---|---|
#8051 | Flush Mount Sensor: Ideal for residential or light commercial applications where customer requires nothing to be seen on the wall. Friction fit in a 1" opening. Air gap of 1/4" required. | Disk: 1 1/2" dia. | 18-24 gauge 2 conductor wire (or more conductors) | 8600, 8620, 8620W, 8910, 8910W, 8920W, 8800, 8820, 8830, 8840 |
#8052 | Outdoor/Duct Sensor: Designed for outdoor or duct installation including with use of zone control panels. | Probe: 1/4" dia. x 1 3/4" L Bracket: 3/4" x 3/4" |
18-24 gauge 2 conductor wire (or more conductors) | 8600, 8620, 8620W, 8910, 8910W, 8920W, 8800, 8820, 8830, 8840 |
#8053 | Surface Mount Sensor: Perfect for light indoor commercial applications to prevent tampering. | W: 3 1/2" H: 2 1/2" D: 7/8" | 18-24 gauge 2 conductor wire (or more conductors) | 8600, 8620, 8620W, 8910, 8910W, 8920W, 8800, 8820, 8830, 8840 |
#8022 | 3-Wire to 4-Wire Adapter: Used to add a wire to a thermostat, fix a broken wire or add a common wire to a 4-wire system. | W: 2 7/8" H: 1 3/4" D: 1 47/50" | 18-22 gauge stranded or solid thermostat wire can be used for all wire runs | All thermostats |
#8028 | Damper Power Distribution Panel: For applications where needed dampers outnumber control capability of any AprilAire Zone Control Panel. | W: 10 1/2" H: 5" D: 1 7/10" | - | All zone control panels |
Automation Modules
#6401 | Expansion Panel: Two-zone expansion panel that supports 2-wire or 3-wire dampers. | W: 10 1/2" H: 5" D: 1 7/10" | Cat 6 or greater | 6404 |
#8081 | Temperature Support Module: Averages up to eight temperature locations per thermostat. | W: 10 1/2" H: 5" D: 1 7/10" | Cat 6 or greater | 8800, 8820, 8830, 8840 |
#8082 | Temperature and RH Support Module: Averages four temperatures (on-board or off-board) and four humidity values (on-board only). | W: 3 1/2" H: 2 1/2" D: 7/8" | Cat 6 or greater | 8800, 8820, 8830, 8840 |
#8083 | Flush Temperature and RH Support Module: Averages four temperature and four RH values. | Disk: 1 1/2" dia. Cylinder Hole: 1" off wall, 1/4" air gap | Cat 6 or greater | 8800, 8820, 8830, 8840 |
Ventilation Climate Zones
Managing the quality of ventilated air delivered into the home is critical to providing a healthy indoor environment. Requirements change significantly based on climate. AprilAire ventilation solutions work with HVAC equipment to remove moisture, harmful particulates, and other contaminants like VOCs. It's critical to use intelligent ventilation controls and application guidance to properly ventilate rather than relying on exhaust ventilation which simply pulls air through walls.
Map Description: A map of the United States is divided into climate zones (numbered 1-7) with color coding, indicating regions like Marine, Dry, Moist, Warm & Moist, Warm & Dry, Cold & Moist, Cold & Dry, and Extreme Cold & Moist. Source: 2012 & 2015 International Residential Code N1101.10 (R301.1).
Use this map and the adjoining application guide to determine the recommended product solution for your climate. Recommendations are based on moisture removal demands, energy savings, and integration with HVAC equipment.
Ventilation Supply Solutions - AprilAire Ventilation Application Matrix
ZONE | CLIMATE TYPE | MAJOR CITIES | PRIMARY SOLUTION¹ | FRESH AIR DUCTED² | ECONOMY- OR COMFORT- FOCUSED SOLUTION | MULTI-FAMILY NEW CONSTRUCTION SOLUTION |
---|---|---|---|---|---|---|
1 | Hot & Moist | Miami | E100V + 8190FF or 8192A Dehumidifies incoming ventilation air |
HVAC Return | 8145A or 8126A | 8144NC |
2 | Hot & Moist | Orlando, Mobile, New Orleans, Houston, Austin, San Antonio | E100V + 8190FF or 8192A Dehumidifies incoming ventilation air |
HVAC Return | 8145A or 8126A | 8144NC |
2 | Hot & Dry | Phoenix, Tucson | 8142A Mixes ventilation air after cooling or heating |
HVAC Supply | 8126A | 8144NC |
3 | Warm & Moist | Charlotte, Charleston, Atlanta, Little Rock, Oklahoma City, DFW | E100V + 8190FF or 8192A Dehumidifies incoming ventilation air |
HVAC Return | 8145A or 8126A | 8144NC |
3 | Warm & Dry | El Paso, Las Vegas, Los Angeles, Sacramento | 8142A Mixes ventilation air after cooling or heating |
HVAC Supply | 8126A | 8144NC |
3 | Warm & Marine | San Francisco, San Jose | Mixes ventilation air after cooling or heating | HVAC Supply | 8145A or 8126A | 8144NC |
4 | Mixed & Moist | Philadelphia, Washington DC, Baltimore, Nashville, St. Louis, Wichita, Louisville | 8145A Mixes ventilation air prior to cooling or heating |
HVAC Return | E100V + 8190FF, 8192A or 8126A | 8144NC |
4 | Mixed & Dry | Albuquerque, Amarillo | 8142A Mixes ventilation air after cooling or heating |
HVAC Supply | 8145A or 8126A | 8144NC |
4 | Mixed & Marine | Portland, Seattle | 8142A Mixes ventilation air after cooling or heating |
HVAC Supply | 8145A or 8126A | 8144NC |
5 | Cool & Moist | Boston, Pittsburgh, Columbus, Indianapolis, Detroit, Chicago, Des Moines, Omaha | 8145A Mixes ventilation air prior to cooling or heating |
HVAC Return | 8126A | 8144NC |
5 | Cool & Dry | Denver, Salt Lake City, Boise, Reno | 8145A Mixes ventilation air prior to cooling or heating |
HVAC Supply or Return | 8142A or 8126A | 8144NC |
6 | Cold & Moist | Toronto, Vancouver, Milwaukee, Madison, Minneapolis-St Paul, Sioux Falls | 8145A Mixes ventilation air prior to cooling or heating |
HVAC Return | 8126A | 8144NC |
6 | Cold & Dry | Helena, Cheyenne | 8145A Mixes ventilation air prior to cooling or heating |
HVAC Return | 8126A | 8144NC |
7 | Extreme Cold & Moist | Fargo, Duluth, Calgary, Edmonton | 8126A Mixes ventilation air prior to cooling or heating |
HVAC Return | 8144NC |
¹ Primary AprilAire recommended supply ventilation solution for optimal performance and building code adherence.
² HVAC application considerations based upon moist versus dry air, and proper mixing into the ductwork.