AprilAire All Product Guide

Quick Reference | January 2022

Healthy Air in every home.

AprilAire Healthy Air Solutions

Legend: ? Radon | ? Unfiltered air | ?️ Ventilated air | ? Dry air | ♨️ Humid air | ?️ Temperature controlled spaces

A diagram illustrates a house with different zones representing radon presence, unfiltered air, ventilated air, dry air, humid air, and temperature-controlled spaces. Arrows indicate airflow and temperature distribution within the home, showing temperatures of 72°F in some rooms and 68°F in others.

AprilAire provides professional-grade Healthy Air solutions. Our mission is to enhance people's health by improving the air in their homes. Healthy Air is essential to living a healthy lifestyle and improving overall well-being. We are inspired by the needs of consumers and the expertise of professional contractors to create, design, and build innovative solutions.

AprilAire is Healthy Air.

Features: 5-year warranty on all installed products, Designed & Engineered in the USA.

Radon Mitigation

Mitigation Fans

AprilAire Radon Mitigation Fans are specifically designed for radon mitigation, providing superb performance and ultra-quiet operation.

Features:

MODEL FAN DUCT DIAMETER RECOMMENDED WATTS MAXIMUM OPERATING PRESSURE "WC 9.7" 11.75" 11.9" 8.5" 8.6" 10.9"
ARN15F 4" 41-72 1.7 166 126 82 41 3 -
ARN25F 6" 70-170 2.3 375 340 282 204 140 70
ARNHPF 3" 70-170 4.0 - 110 97 88 79 68 54 36 14

TYPICAL CFM vs. STATIC PRESSURE WC:

0" 0.2" 0.5" 1.0" 1.5" 2.0" 2.5" 3.0" 3.5" 4.0"
ARN15F 166 126 82 41 3 - - - - -
ARN25F 375 340 282 204 140 70 - - - -
ARNHPF 110 97 88 79 68 54 36 14 - -

Mitigation Kits

Kits include: fan, manometer, couplings, and radon system alarm.

Application RRNC 2.0 Radon Fan Type Dimensions DxH Color Fan Duct Diameter Pressure
ARN15K (Slab size <1500 sq. ft.) RF1, RF2 9.7" x 8.5" White 4" 1.7" WC
ARN25K (Slab size 1500-2500 sq. ft.) - 11.75" x 8.6" White 6" 2.3" WC
ARNHPK (Moderate to Tight Soil) - 11.9" x 10.9" White 3" 4.0" WC

Radon Accessories

ACCESSORY DESCRIPTION
Manometer P/N ARN05M Mounts to the outside of PVC pipe on a radon mitigation system and measures vacuum pressure in real time, helping to indicate potential issues with the fan. It can serve as a secondary indicator that vacuum pressure has changed in the event of a system alarm going off, helping to confirm that it's not a false alarm.
Transition Fitting P/N ARNTF4 Consolidates the number of fittings needed in outdoor radon mitigation system installations. Connects a 4" fan pipe to a 4" exhaust pipe with a weir (not included) for capturing and draining condensate. Weir is included in the Condensate Bypass Kit.
Condensate Bypass Kit P/N ARNCBK This kit is designed to drain condensation around the fan in outdoor installs.
Radon-T Fitting P/N ARNSIT Designed for use in adding radon mitigation to new construction and crawl spaces. Provides 4-way airflow, allowing moisture and soil gases to be drawn from all angles.
Radon System Alarm P/N ARNALM Advanced vacuum monitoring device utilizing piezoresistive pressure sensor (PPS) technology. It provides homeowners with an easy-to-read, easy-to-use system alarm that requires no interpretation.

Warranty: 5-year warranty on all AprilAire Radon Mitigation Fans.

Humidity Control

Humidifiers

Humidifiers - Part of the AprilAire Healthy Air System.

HUMIDIFIERS TYPE OF HUMIDIFICATION UNIT SIZE (WIDTH X HEIGHT X DEPTH) PLENUM OPENING CAPACITY (GPD= GALLONS PER DAY) ELECTRICAL DATA WATER PANEL/CANISTER
#800, #801 Steam - - 11.5 GPD 120V 60HZ, 11.5 AMP -
#865, #866*** Ductless Steam Fan Pack: 14" x 6 29/32" x 3 15/16"
Finished Grille: 16 3/16" x 9" x 1 3/32"
- 16.0 GPD 120V 60HZ, 16.0 AMP -
#700*, #700M** Fan Powered Evaporative 15 29/32" x 18" x 10 11/32" - 20.5 GPD / 30.0 GPD 208V 60HZ, 11.5 AMP / 16.0 AMP 80
#600*, #600M** Large Bypass Evaporative 15 3/8" x 15 3/4" x 10 1/4"
6" dia. round opening
W: 10"
H: 12 3/4"
18 GPD 120V 60HZ, 0.8 AMP 35
#500*, #500M** Small Bypass Evaporative 15 5/8" x 13" x 10 1/4"
6" dia. round opening
W: 9 1/2"
H: 9 1/2"
12 GPD 24V 60HZ, 0.5 AMP 10
#400*, #400M** Water Saver Bypass Evaporative 15 3/8" x 15 3/4" x 10 1/4"*
6" dia. round opening
W: 10"
H: 12 3/4"
17 GPD 24V 60HZ, 0.5 AMP 45
#300 Self-Contained Evaporative 14 3/8" x 12 1/2" x 22 3/32" - 13 GPD 120V 60HZ, 0.7 AMP 35

Humidifier Sizing Guidelines (GPD Needed Per Square Foot** Based on Building Structure Tightness):

STRUCTURE TIGHTNESS VOLUME OF BUILDING (FT3) BUILDING FLOOR AREA (FT2) WITH 8 FT CEILINGS
8000 12000 16000 20000 24000 32000 40000
1000 Ft2 1500 Ft2 2000 Ft2 2500 Ft2 3000 Ft2 4000 Ft2 5000 Ft2
Tight 3.3 GPD 5.0 GPD 6.7 GPD 8.3 GPD 10.0 GPD 13.4 GPD 16.7 GPD
Average 6.7 GPD 10.0 GPD 13.4 GPD 16.7 GPD 20.0 GPD 26.7 GPD 33.4 GPD
Loose 10.0 GPD 15.0 GPD 20.0 GPD 25.0 GPD 30.1 GPD 40.1 GPD 50.1 GPD

Regional Humidifier Applications: AprilAire humidifiers can be installed on many types of HVAC equipment and controlled for optimal humidity. This guide assists in selecting the appropriate product based on geography and heating equipment. The portfolio includes evaporative flow-through, fan-powered, and steam humidifiers. Considerations include plenum temperature, airflow, and run time. AprilAire's control strategy maximizes humidifier run time/capacity. Automatic controls have an integrated blower activation relay. Installations with manual controls can increase capacity by setting the thermostat fan to 'ON'. Plumb evaporative humidifiers to hot water where recommended.

Climate Zones Map Description: A map of the United States is divided into climate zones (e.g., Mountain, Midwest/Northeast, Desert (Southwest), Mid-Atlantic/Mid-Southern, South) with color coding.

Dehumidifiers

Dehumidifiers - Part of the AprilAire Healthy Air System.

DEHUMIDIFIERS UNIT SIZE (WIDTH X HEIGHT X LENGTH) CAPACITY (PPD = PINTS PER DAY) AIRFLOW @ VARYING E.S.P. (EXTERNAL STATIC PRESSURE - DRY COIL) UNIT WEIGHT (LBS.)
#E070 12 1/2" x 12 1/2" x 25" 70 ppd 200 CFM @ 0.0" w.c.
170 CFM @ 0.2" w.c.
140 CFM @ 0.4" w.c.
56
#E080, #E080H1 14" x 15" x 26" 80 ppd 185 CFM @ 0.0" w.c.
135 CFM @ 0.2" w.c.
85 CFM @ 0.4" w.c.
63
#E100, #E100C2 14" x 15" x 26" 100 ppd 280 CFM @ 0.0" w.c.
245 CFM @ 0.2" w.c.
210 CFM @ 0.4" w.c.
64
#E130, #E130H1, #E130C2 19 1/2" x 18 1/2" x 30" 130 ppd 310 CFM @ 0.0" w.c.
270 CFM @ 0.2" w.c.
225 CFM @ 0.4" w.c.
98

Dehumidifier Sizing Guidelines: Recommended home floor area (ft²) is for sizing guidance only. Actual size depends on location, ventilation rate, occupant habits, AC system moisture removal, and environmental conditions. Values are for the most humid locations within each region. Use the Dehumidifier Selection Assistant at AprilAirepartners.com/dsa for on-demand recommendations.

MODEL E080 MODEL E100 MODEL E130
LOOSE TIGHT LOOSE TIGHT LOOSE TIGHT
REGION A 3,200 Ft² 4,400 Ft² 4,000 Ft² 5,500 Ft² 5,200 Ft² 7,200 Ft²
REGION B 2,600 Ft² 3,900 Ft² 3,200 Ft² 5,000 Ft² 3,900 Ft² 6,500 Ft²
REGION C 1,600 Ft² 2,300 Ft² 2,000 Ft² 3,000 Ft² 2,300 Ft² 3,600 Ft²

Air Filtration

Air Cleaners

Air Cleaners - Part of the AprilAire Healthy Air System.

AIR CLEANERS NOMINAL SIZE (IN INCHES) CABINET SIZE (IN INCHES) SHIPPING WEIGHT (LBS) INCLUDED FILTER COMPATIBLE FILTERS*
#2216, #2416, #2516 20 x 25
16 x 25
31 x 28
W: 6 3/4" H: 22 1/16" D: 27 3/8"
W: 6 3/4" H: 17 3/4" D: 30 1/16"
W: 6 3/4" H: 31" D: 30 1/16"
20
19.25
24.9
MERV 16
MERV 13
MERV 11
213CBN, 213, 210
413CBN, 413, 410
513CBN, 513, 510
#2210 20 x 25 W: 6 3/4" H: 22 1/16" D: 27 3/8" 19 MERV 13 216, 213CBN, 210
#2310 20 x 20 W: 6 3/4" H: 20 3/8" D: 22 1/16" 17 MERV 11 313
#2410 16 x 25 W: 6 3/4" H: 17 3/4" D: 30 1/16" 19 MERV 11 416, 413CBN, 410
#1110, #1210, #1310, #1410, #1510, #1910, #1610, #1620 16 x 20
20 x 25
20 x 20
16 x 25
31 x 28
25 x 20
16 x 25
20 x 25
W: 6 3/4"H: 17 3/4" D: 22 1/16"
W: 6 3/4" H: 22 1/16" D: 27 3/8"
W: 6 3/4" H: 20 3/8" D: 22 1/16"
W: 6 3/4" H: 17 3/4" D: 30 1/16"
W: 6 3/4" H: 31" D: 30 1/16"
W: 6 3/4" H: 25 1/16" D: 22 1/16"
W: 15 11/16" H: 17 13/16" D: 30 3/16"
W: 15 11/16" H: 22 1/8" D: 27 3/8"
13
20
15
19
28
18
31
32.4
MERV 11
MERV 13
MERV 13
MERV 13
MERV 13
MERV 13
MERV 13
MERV 13
113, 213, 213CBN, 210
216, 213CBN, 213
313, 413, 410
416, 413CBN, 413
513CBN, 513, 510
913
410
210
ELECTRONIC AIR CLEANER #5000 16 x 25 W: 12" H (front): 18 3/8"
H (back): 17 3/4" D: 31"
35 501 -

Filter Grille Air Cleaners**

APRILAIRE FILTER GRILLE NOMINAL SIZE (IN INCHES) FILTER MODEL SHIPPING WEIGHT
1625FG11 16 x 25 610 16 lbs.
1625FG13 16 x 25 613 16 lbs.
2025FG11 20 x 25 810 18 lbs.
2025FG13 20 x 25 813 18 lbs.

Air Filters

Air Filters - Part of the AprilAire Healthy Air System.

Pressure Drop Chart

STATIC PRESSURES AT VARIABLE CFM (IN. W.C.)*

FILTER NO. 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000
MERV 16 (ALLERGY & ASTHMA) 0.06 0.09 0.13 0.17 0.23 0.29 0.36 - - - - - - - -
416 0.07 0.10 0.13 0.18 0.24 0.31 - - - - - - - - -
516 0.04 0.05 0.07 0.09 0.10 0.13 0.15 0.18 0.21 0.24 0.27 0.31 - - -
MERV 13 (HEALTHY HOME) 0.03 0.07 0.11 0.16 0.22 0.29 - - - - - - - - -
213 0.02 0.04 0.06 0.09 0.12 0.15 0.19 0.23 0.27 0.31 - - - - -
313 0.03 0.05 0.09 0.13 0.17 0.23 - - - - - - - - -
413 0.02 0.05 0.07 0.10 0.14 0.17 0.22 0.26 0.31 0.37 - - - - -
513 0.01 0.02 0.04 0.05 0.05 0.07 0.08 0.10 0.11 0.13 0.15 0.17 0.18 0.20 0.23
613 0.02 0.05 0.07 0.10 0.14 0.17 0.22 0.26 0.31 0.37 - - - - -
813 0.02 0.04 0.06 0.09 0.12 0.15 0.19 0.23 0.27 0.31 - - - - -
913 - 0.04 0.07 0.10 0.13 0.17 0.22 0.25 0.30 0.35 - - - - -
213CBN 0.04 0.07 0.10 0.13 0.17 0.21 0.25 0.30 0.35 - - - - - -
413CBN 0.04 0.07 0.10 0.14 0.19 0.24 0.29 0.36 0.43 - - - - - -
513CBN 0.03 0.04 0.05 0.07 0.08 0.10 0.12 0.15 0.17 0.20 0.22 0.25 0.29 0.32 -
MERV 11 (CLEAN AIR) 0.02 0.05 0.06 0.10 0.14 0.20 - - - - - - - - -
210 0.02 0.03 0.04 0.06 0.08 0.11 0.13 0.16 0.19 0.22 - - - - -
310 0.02 0.04 0.06 0.10 0.14 0.19 - - - - - - - - -
410 0.02 0.03 0.05 0.07 0.09 0.12 0.15 0.19 0.22 0.27 - - - - -
510 0.02 0.02 0.03 0.04 0.04 0.05 0.06 0.07 0.09 0.10 0.12 0.14 0.15 0.17 0.19
610 0.02 0.03 0.05 0.07 0.09 0.12 0.15 0.19 0.22 0.27 - - - - -
810 0.02 0.03 0.04 0.06 0.08 0.11 0.13 0.16 0.19 0.22 - - - - -
910 - 0.03 0.05 0.07 0.09 0.12 0.15 0.18 0.22 0.27 - - - - -
201 0.02 0.04 0.05 0.08 0.10 0.12 0.15 0.18 0.21 0.25 - - - - -
401 0.02 0.04 0.05 0.08 0.10 0.14 0.17 0.21 0.25 0.29 - - - - -
501 0.02 0.04 0.05 0.08 0.10 0.14 0.17 0.21 0.25 0.29 - - - - -

*Highest value shown is maximum recommended airflow capacity.

Removal Efficiency

0.3-1.0 MICRONS 1.0-3.0 MICRONS 3.0-10.0 MICRONS
MERV 16 95% 98% 99%
MERV 13 63% 88% 93%
MERV 11 37% 67% 92%
MERV 10 22% 56% 92%
EAC (MODEL 5000) 89% 95% 98%

Test Method: MERV 10-16 - ASHRAE 52.2.2012, EAC - AHRI 680-2009

Upgrade Kits

UPGRADE KITS NOMINAL SIZE (IN INCHES) COMPATIBLE WITH INCLUDED FILTER RAILS MODEL NUMBER STATIC PRESSURE DROP (IN. W.C.) @ 1200 CFM MAXIMUM AIRFLOW CAPACITY (IN CFM)
#1213 20 x 25 AprilAire or Space-Gard 2200 213 4893 0.15 2000
#1413 16 x 25 AprilAire or Space-Gard 2400 413 4894 0.17 2000
UPGRADE RAILS Nominal Size (in inches) Compatible With Uses Filter Model Maximum Airflow Capacity (in CFM)
#4893 20x25 2200 Space-Gard Units 210, 213, 213CBN 2000
#4894 16x25 2400 Space-Gard Units 410, 413, 413CBN 2000
#4897 16x25 16x25 Competitive Cabinets 610, 613 2000
#4898 20x25 20x25 Competitive Cabinets 810, 813 2000
16x20 16x20 Competitive Cabinets 110, 113 1200
20x20 20x20 Competitive Cabinets 310, 313 1200

Replacement Filters

FILTER NO. USED WITH APRILAIRE AIR CLEANER MODELS NOMINAL SIZE (IN INCHES) STATIC PRESSURE DROP (IN. W.C.) @ 1200 CFM MAXIMUM AIRFLOW CAPACITY (IN CFM)
201 AprilAire/Space-Gard* 2200 20 x 25 0.12 2000
401 AprilAire/Space-Gard* 2400 16 x 25 0.14 2000
501 - - - -

*Air Cleaner models no longer available.

Healthy Air Controls

Thermostats

Thermostats - Part of the AprilAire Healthy Air System.

RESIDENTIAL MODEL NO. STAGES Non-Programmable Programmable Programmable with Event-Based™ Air Cleaning Programmable Touch Screen IAQ Control Touch Screen Equipment Control Module
HOME AUTOMATION MODEL NO. 83/5" x 93/5" x 19/10"
8444 - 1H/1C
8446 - 2H/1C HP
8448 - 2H/2C, 4H/2C HP
✔️
8463 - 1H/1C
8465 - 2H/1C HP
8466 - 2H/2C, 4H/2C HP
✔️
8476W**
8476 - 2H/2C, 4H/2C HP
✔️
8600 - 2H/2C, 4H/2C HP ✔️
8620W**
8620 - 2H/2C, 4H/2C HP
✔️
8910W**
8910 - 3H/3C, 4H/2C HP
8920W** - 3H/3C, 4H/2C HP
✔️
8810, 8800, 8820, 8830, 8840

Features: Easy to Read Display ✔️, Simple Setup ✔️, Displays Outdoor Temperature (if equipped) ✔️, Adjustable Temperature Differential ✔️, Progressive Recovery ✔️, Heat Blast ✔️, Event-Based™ Air Cleaning ✔️.

Control Functions: Air Cleaning Notice ✔️, Change Filter Alert ✔️, Automatic or Manual Humidifier Control ✔️, "Humidifier On" Notice ✔️, Displays Indoor RH ✔️, Energizes HVAC Blower for Humidity ✔️, Controls Humidifier with 24 VAC Dry Contact ✔️, Controls Whole-Home Dehumidifier ✔️, Controls A/C Equipment for Dehumidification ✔️, Displays Indoor RH ✔️, "Dehumidifier On" Notice ✔️, Energizes HVAC Blower for Dehumidification ✔️, Controls Dehumidifier with 24 VAC Dry Contact ✔️, Programmable for Timed Ventilation ✔️, Programmable for ASHRAE 62.2 Ventilation ✔️, Configurable Temperature and Humidity Limits ✔️, "Ventilation On" Notice ✔️.

Product Configuration: Controls Air Cleaner and Humid or Dehumid or Vent ✔️, Controls Air Cleaner and Humid, Dehumid and Vent ✔️, Wired Outdoor Temperature Sensor Included ✔️, Two-Part Design - Only 3 Wires to the Living Space ✔️.

Zone Control Systems

6000 SERIES PRODUCT CONFIGURATIONS

KITS BLACK WHITE
2-ZONE Model 6010: 2-Zone Complete Kit* Model 6015: 2-Zone Complete Kit*
3-ZONE Model 6020: 3-Zone Complete Kit* Model 6025: 3-Zone Complete Kit*
INDIVIDUAL COMPONENTS BLACK WHITE
Model 6030: 2-Zone Base
Model 6040: 3-Zone Base
Model 6050: Secondary Zone UI
Model 6035: 2-Zone Base
Model 6045: 3-Zone Base
Model 6055: Secondary Zone UI

* Kits include outdoor temperature sensor along with duct probe.

Zone Control Panels

MODEL SPECIFICATIONS
UNIVERSAL
6404 Zone Universal Multistage
(Can be expanded to 12 zones with Model 6401)
6403 Zone Universal Multistage
2 Heat 2 Cool or 4 Heat 2 Cool (Heat Pump)
Compatible with Model 8056 wireless outdoor sensor
Overall Dimensions: 8 63/100" W x 14 18/25" H x 1 43/50" D
Humidity: 5%-90% RH, non-condensing
Operating Temperature: 32°F-158°F
Shipping Temperature: -40°F-180°F
Voltage: 18-30VAC 50/60 Hz
Maximum Current: Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; zone panel consumption: 4VA max.
Note: Use 18 or 20 AWG solid (non-stranded) wire.
ZONED COMFORT CONTROL™ KITS** AVAILABLE: 6404K & 6403K
HEAT PUMP ONLY
6303 Zone Heat Pump
6302 Zone Heat Pump
2 Heat 1 Cool Single Stage
Overall Dimensions: 8 63/100" W x 9 33/50" H x 1 43/50" D
Humidity: 5% - 90% RH, non-condensing
Operating Temperature: 32°F-158°F
Shipping Temperature: -40°F-180°F
Voltage: 18-30VAC 50/60 Hz
Maximum Current: Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; zone panel consumption: 4VA max.
Note: Use 18 or 20 AWG solid (non-stranded) wire.
ZONED COMFORT CONTROL™ KITS** AVAILABLE: 6303K & 6302K
CONVENTIONAL ONLY
6203 Zone Heat/Cool
6202 Zone Heat/Cool
1 Heat 1 Cool Single Stage
Overall Dimensions: 8 63/100" W x 9 33/50" H x 1 43/50" D
Humidity: 5%-90% RH, non-condensing
Operating Temperature: 32°F-158°F
Shipping Temperature: -40°F-180°F
Voltage: 18-30VAC 50/60 Hz
Maximum Current: Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; zone panel consumption: 4VA max.
Note: Use 18 or 20 AWG solid (non-stranded) wire.
ZONED COMFORT CONTROL™ KITS** AVAILABLE: 6303K & 6302K

** Zoned Comfort Control Kits include: Zone panel, 6" duct probe and 24V 40VA universal transformer.

Zone Dampers

Rectangular Dampers

NOMINAL WIDTH (IN INCHES) 8" (203MM) 10" (254MM) 12" (305MM) 14" (356MM) 16" (406MM) 18" (457MM) 20" (508MM) 22" (559MM) 24" (610MM) 26" (660MM) 28" (711MM) 30" (762MM)
Side Mount
(Motor mounted on short dimension)
W3 indicates power open/power closed
6721
6721W3
6722
6722W3
6723
6723W3
6724
6724W3
6725
6725W3
6726
6726W3
6727
6727W3
6728
6728W3
6729
6729W3
6730
6730W3
6731
6731W3
6753
6753W3
Bottom Mount
(Motor mounted on long dimension)
6732
6732W3
6733
6733W3
6734
6734W3
6735
6735W3
6736
6736W3
6737
6737W3
6738
6738W3
6739
6739W3
6740
6740W3
6741
6741W3
6742
6742W3
NOMINAL HEIGHT (IN INCHES) 10 3/4" 10 3/4" 10 3/4" 10 3/4" 10 3/4" 12 3/4" 14 3/4" 16 3/4" 19 31/50" 22"
6743
6743W3
6744
6744W3
6745
6745W3
6746
6746W3
6747
6747W3
6748
6748W3
6749
6749W3
6750 6751 6752
6754
6754W3
6755
6755W3
6756
6756W3
6757
6757W3
6758
6758W3
6759
6759W3
6760 6761 6762
6763
6763W3
6764
6764W3
6765
6765W3
6766
6766W3
6767
6767W3
6768
6768W3
6769
6769W3
6770 6771 6772 6773 6774
6775 6776 6777

* Rectangular Damper Dimension = Nominal width + 3.5"

Round Dampers

NOMINAL DIAMETER (IN INCHES) 4" (102MM) 5" (127MM) 6" (152MM) 7" (178MM) 8" (203MM) 9" (229MM) 10" (254MM) 12" (305MM) 14" (356MM) 16" (406MM) 18" (457MM) 20" (508MM)
Zone Damper
(Normally open/power closed)
W3 indicates power open/power closed
6606
6606W3
6607
6607W3
6608
6608W3
6609
6609W3
6610
6610W3
6612
6612W3
6614
6614W3
6616
6616W3
6618 6620
NOMINAL HEIGHT (IN INCHES) 10 3/4" 10 3/4" 10 3/4" 10 3/4" 10 3/4" 12 3/4" 14 3/4" 16 3/4" 19 31/50" 22"
6506 6508 6510
Ventilation Damper
(Normally closed/power opened)
6108 6110 6112 6114 6116
Barometric Pressure Relief
(Air flow activated)
6208 6210 6212 6214 6216 6218 6220
Static Pressure Relief
(Power activated)
6704 6705 6706 6707 6708 6710
Round Slip-In Damper
(Normally open/power closed)
W: 3 4/5"
H: 12 3/5"
D: 7 3/10"
W: 3 4/5"
H: 12 3/5"
D: 8 3/10"
W: 3 4/5"
H: 12 3/5"
D: 9 3/10"
W: 3 4/5"
H: 12 3/5"
D: 10 3/10"
W: 3 4/5"
H: 12 3/5"
D: 11 3/10"
W: 3 4/5"
H: 12 3/5"
D: 13 3/10"

* Round Damper Dimension = Nominal diameter + 4.5"

Fresh Air Ventilation

Ventilators and Ventilating Dehumidifiers

Part of the AprilAire Healthy Air System.

VENTILATION SYSTEMS UNIT SIZE SHIPPING WEIGHT (LBS.) AIRFLOW @ 0.2 IN. W.C. (CFM) DESCRIPTION
VENTILATING DEHUMIDIFIERS
#E100V + 8190FF W: 14 1/2"
H: 23 1/2"
L: 48 1/4"
82.00 (E100V)
16.80 (8190FF)
150 The Ventilating Dehumidifier (Models E100V + 8190FF) brings in fresh air to meet ventilation needs while removing excess humidity from the incoming outdoor air. Fresh air is brought in whenever the HVAC system or dehumidifier is running to meet that need. If the required time is not met through these run cycles, the ventilating dehumidifier will bring in fresh air and remove any excess humidity.
#8192A W: 15"
H: 14"
L: 26"
82.00 245 The 8192A features an integrated ventilation control. It draws fresh air into the home by energizing its fan and opening its vent damper. If the incoming air is above a set relative humidity percentage point, the outside air is dehumidified by the 8192A.
FRESH AIR VENTILATORS
#8145A, #8145NC, #8145K
#8142A, #8142NC
W: 12 1/4" H: 11 3/4" L: 23 2/5"
W: 13 1/5" H: 6 7/10" L: 11 9/10"
15.00 (8145A)
14.50 (8145NC)
21.00 (8145K)
11.50
10.75
210 The 8145A or 8142A delivers fresh air into the return or supply duct by energizing its fan and opening its integrated damper. Both models feature an 8120A ventilation controller integrated into the unit. NC models do not include an on-board controller so that ventilation can be controlled via thermostat. The 8145K comes with 8145NC, 8120A control, inlet hood and start collar for adding ventilation to existing homes and systems.
#8144NC W: 10 1/4" H: 18 1/8" D: 10 1/4" 20.50 130 The 8144NC provides continuous low-volume ventilation for smaller single- and multi-family homes. A separate 8120A ventilation controller can be added to set the unit to operate by the controller's Code or Comfort functions.
#8120A (VENTILATION CONTROLLER) W: 4 11/100" H: 3 3/5" D: 1 59/100" 0.50 - The 8120A engages a fan or damper on ventilation solutions to deliver fresh air to return duct. It can provide fresh air within set high/low outdoor temperature and indoor RH limits.
#8126A (VENTILATION SYSTEM) W: 10 8/25" H: 10 3/4" D: 6" 6.50 - The 8126A includes a powered damper, ventilation controller, and installation accessories. The controller energizes the damper, mounted on the return side of the HVAC blower. When the HVAC blower energizes, negative pressure draws fresh air into the home.
KITCHEN VENTILATION KITS
#KV08
#KV10
W: 8" H: 10 3/4" D: 12 1/3"
W: 10" H: 10 3/4" D: 14 1/3"
6.00
6.70
185
390
The KV08, KV10 Kitchen Ventilation Kits provide make-up air locally to areas where high-CFM range hoods (typically near 400 CFM or above) are used to prevent home depressurization and its undesired side effects.
FRESH AIR EXCHANGER (ERV)
#8100
W: 37 3/8" H: 20 23/40" D: 12 3/4" 87.00 130 The 8100 draws in fresh outdoor air and exhausts stale indoor air, transferring energy (heating or cooling) between the two air sources, as well as transferring moisture from the higher moisture airstream to the airstream with lower moisture. This creates a balanced airflow and eliminates pressure. A ventilation controller or thermostat (both sold separately) energizes blowers within the ventilator.

Accessories

ACCESSORIES PRODUCT DESCRIPTION UNIT SIZE TYPE OF WIRE COMPATIBLE MODELS
#8051 Flush Mount Sensor: Ideal for residential or light commercial applications where customer requires nothing to be seen on the wall. Friction fit in a 1" opening. Air gap of 1/4" required. Disk: 1 1/2" dia. 18-24 gauge 2 conductor wire (or more conductors) 8600, 8620, 8620W, 8910, 8910W, 8920W, 8800, 8820, 8830, 8840
#8052 Outdoor/Duct Sensor: Designed for outdoor or duct installation including with use of zone control panels. Probe: 1/4" dia. x 1 3/4" L
Bracket: 3/4" x 3/4"
18-24 gauge 2 conductor wire (or more conductors) 8600, 8620, 8620W, 8910, 8910W, 8920W, 8800, 8820, 8830, 8840
#8053 Surface Mount Sensor: Perfect for light indoor commercial applications to prevent tampering. W: 3 1/2" H: 2 1/2" D: 7/8" 18-24 gauge 2 conductor wire (or more conductors) 8600, 8620, 8620W, 8910, 8910W, 8920W, 8800, 8820, 8830, 8840
#8022 3-Wire to 4-Wire Adapter: Used to add a wire to a thermostat, fix a broken wire or add a common wire to a 4-wire system. W: 2 7/8" H: 1 3/4" D: 1 47/50" 18-22 gauge stranded or solid thermostat wire can be used for all wire runs All thermostats
#8028 Damper Power Distribution Panel: For applications where needed dampers outnumber control capability of any AprilAire Zone Control Panel. W: 10 1/2" H: 5" D: 1 7/10" - All zone control panels

Automation Modules

#6401 Expansion Panel: Two-zone expansion panel that supports 2-wire or 3-wire dampers. W: 10 1/2" H: 5" D: 1 7/10" Cat 6 or greater 6404
#8081 Temperature Support Module: Averages up to eight temperature locations per thermostat. W: 10 1/2" H: 5" D: 1 7/10" Cat 6 or greater 8800, 8820, 8830, 8840
#8082 Temperature and RH Support Module: Averages four temperatures (on-board or off-board) and four humidity values (on-board only). W: 3 1/2" H: 2 1/2" D: 7/8" Cat 6 or greater 8800, 8820, 8830, 8840
#8083 Flush Temperature and RH Support Module: Averages four temperature and four RH values. Disk: 1 1/2" dia. Cylinder Hole: 1" off wall, 1/4" air gap Cat 6 or greater 8800, 8820, 8830, 8840

Ventilation Climate Zones

Managing the quality of ventilated air delivered into the home is critical to providing a healthy indoor environment. Requirements change significantly based on climate. AprilAire ventilation solutions work with HVAC equipment to remove moisture, harmful particulates, and other contaminants like VOCs. It's critical to use intelligent ventilation controls and application guidance to properly ventilate rather than relying on exhaust ventilation which simply pulls air through walls.

Map Description: A map of the United States is divided into climate zones (numbered 1-7) with color coding, indicating regions like Marine, Dry, Moist, Warm & Moist, Warm & Dry, Cold & Moist, Cold & Dry, and Extreme Cold & Moist. Source: 2012 & 2015 International Residential Code N1101.10 (R301.1).

Use this map and the adjoining application guide to determine the recommended product solution for your climate. Recommendations are based on moisture removal demands, energy savings, and integration with HVAC equipment.

Ventilation Supply Solutions - AprilAire Ventilation Application Matrix

ZONE CLIMATE TYPE MAJOR CITIES PRIMARY SOLUTION¹ FRESH AIR DUCTED² ECONOMY- OR COMFORT- FOCUSED SOLUTION MULTI-FAMILY NEW CONSTRUCTION SOLUTION
1 Hot & Moist Miami E100V + 8190FF or 8192A
Dehumidifies incoming ventilation air
HVAC Return 8145A or 8126A 8144NC
2 Hot & Moist Orlando, Mobile, New Orleans, Houston, Austin, San Antonio E100V + 8190FF or 8192A
Dehumidifies incoming ventilation air
HVAC Return 8145A or 8126A 8144NC
2 Hot & Dry Phoenix, Tucson 8142A
Mixes ventilation air after cooling or heating
HVAC Supply 8126A 8144NC
3 Warm & Moist Charlotte, Charleston, Atlanta, Little Rock, Oklahoma City, DFW E100V + 8190FF or 8192A
Dehumidifies incoming ventilation air
HVAC Return 8145A or 8126A 8144NC
3 Warm & Dry El Paso, Las Vegas, Los Angeles, Sacramento 8142A
Mixes ventilation air after cooling or heating
HVAC Supply 8126A 8144NC
3 Warm & Marine San Francisco, San Jose Mixes ventilation air after cooling or heating HVAC Supply 8145A or 8126A 8144NC
4 Mixed & Moist Philadelphia, Washington DC, Baltimore, Nashville, St. Louis, Wichita, Louisville 8145A
Mixes ventilation air prior to cooling or heating
HVAC Return E100V + 8190FF, 8192A or 8126A 8144NC
4 Mixed & Dry Albuquerque, Amarillo 8142A
Mixes ventilation air after cooling or heating
HVAC Supply 8145A or 8126A 8144NC
4 Mixed & Marine Portland, Seattle 8142A
Mixes ventilation air after cooling or heating
HVAC Supply 8145A or 8126A 8144NC
5 Cool & Moist Boston, Pittsburgh, Columbus, Indianapolis, Detroit, Chicago, Des Moines, Omaha 8145A
Mixes ventilation air prior to cooling or heating
HVAC Return 8126A 8144NC
5 Cool & Dry Denver, Salt Lake City, Boise, Reno 8145A
Mixes ventilation air prior to cooling or heating
HVAC Supply or Return 8142A or 8126A 8144NC
6 Cold & Moist Toronto, Vancouver, Milwaukee, Madison, Minneapolis-St Paul, Sioux Falls 8145A
Mixes ventilation air prior to cooling or heating
HVAC Return 8126A 8144NC
6 Cold & Dry Helena, Cheyenne 8145A
Mixes ventilation air prior to cooling or heating
HVAC Return 8126A 8144NC
7 Extreme Cold & Moist Fargo, Duluth, Calgary, Edmonton 8126A
Mixes ventilation air prior to cooling or heating
HVAC Return 8144NC

¹ Primary AprilAire recommended supply ventilation solution for optimal performance and building code adherence.

² HVAC application considerations based upon moist versus dry air, and proper mixing into the ductwork.

PDF preview unavailable. Download the PDF instead.

aprilaire-all-products-specification-reference-guide-2210 1667837562 Adobe InDesign 17.0 (Macintosh) Adobe PDF Library 16.0.3

Related Documents

Preview AprilAire All Product Guide: Quick Reference - Healthy Air Solutions
Comprehensive quick reference guide to AprilAire's range of healthy air solutions, including radon mitigation, air filtration, humidity control, IAQ control, and ventilation systems. Features product specifications, sizing guides, and application information.
Preview AprilAire Healthy Air Solutions Product Guide
Comprehensive guide to AprilAire's range of healthy air solutions including radon mitigation, humidification, dehumidification, air filtration, ventilation, and zone control systems, with detailed product specifications and application guidance.
Preview Aprilaire Wi-Fi Thermostats with IAQ Control: Smart Home Comfort & Air Quality
Explore Aprilaire's advanced Wi-Fi thermostats offering intuitive control over temperature, humidity, air purity, and fresh air. Enhance home comfort, energy savings, and indoor air quality with smart features and easy app management. View product portfolio and specifications.
Preview Aprilaire Air Cleaners: Product Guide for Enhanced Indoor Air Quality
Discover the Aprilaire Air Cleaners Product Guide, detailing advanced HVAC filtration solutions that improve indoor air quality, reduce system resistance, and protect equipment with longer-lasting, high-efficiency filters.
Preview Aprilaire Healthy Air System Product Guide: Humidifiers, Dehumidifiers, Air Filtration, Controls & Ventilation
Comprehensive product guide for Aprilaire's Healthy Air System, featuring humidifiers, dehumidifiers, air cleaners, thermostats, zone control systems, and ventilation products. Includes specifications, sizing, and application guidance for residential HVAC systems.
Preview AprilAire Humidifier Parts Lists and Diagrams
Comprehensive parts lists and diagrams for various AprilAire humidifier models, including 700, 800, 300, 400, 500, 600, 720, 350, 360, 1150, 1160, and 1180 series. This document provides part numbers and ordering information for replacement parts.
Preview Aprilaire Product Specifications Quick Reference Guide
Comprehensive quick reference guide for Aprilaire HVAC products including humidifiers, dehumidifiers, air cleaners, ventilation systems, thermostats, zone controls, and dampers. Find product specifications, sizing guidelines, and application information.
Preview Aprilaire Fresh Air Ventilation: Product & Application Guide
A comprehensive guide to Aprilaire's range of fresh air ventilation products, including whole-home ventilators, controllers, and energy recovery ventilators (ERVs), designed for enhanced indoor air quality, comfort, and energy efficiency in residential and light commercial applications.