Aprilaire Healthy Air System Product Guide

Quick Reference | September 2021

For more product information, refer to individual product guides at AprilairePartners.com or call 800.334.6011.

Humidifiers

Aprilaire offers a range of humidifiers designed to maintain optimal indoor humidity levels.

SeriesType of HumidificationUnit Size (Width x Height x Depth)OpeningGallons Per Day (GPD)Electrical Data
800 SERIESSteam10" x 20" x 7"--11.5 GPD120V 60Hz 0.8 AMP
800 SERIESDuctless Steam10" x 20" x 7"--11.5 GPD120V 60Hz 0.8 AMP
865Fan Powered Evaporative10" x 20" x 7"10" dia. round opening18 GPD120V 60Hz 0.8 AMP
866Fan Powered Evaporative10" x 20" x 7"10" dia. round opening18 GPD120V 60Hz 0.8 AMP
400 SERIESLarge Bypass Evaporative15" x 15.5" x 6"15" dia. round opening17 GPD24V 60Hz 0.5 AMP
500 SERIESSmall Bypass Evaporative9.5" x 9.5"6" dia. round opening12 GPD24V 60Hz 0.5 AMP
300 SERIESSelf-Contained Evaporative15" x 15.5" x 6"6" dia. round opening13 GPD120V 60Hz 0.7 AMP

Humidifier Sizing Guidelines (GPD Needed Per Square Foot Based on Building Structure Tightness):

Structure Tightness1000 Ft²1500 Ft²2000 Ft²2500 Ft²3000 Ft²4000 Ft²5000 Ft²
Tight3.3 GPD5.0 GPD6.7 GPD8.3 GPD10.0 GPD13.4 GPD16.7 GPD
Average3.3 GPD5.0 GPD6.7 GPD8.3 GPD10.0 GPD13.4 GPD16.7 GPD
Loose3.3 GPD5.0 GPD6.7 GPD8.3 GPD10.0 GPD13.4 GPD16.7 GPD

Note on Heat Pumps: Models 801 & 866 Steam Humidifiers can be installed on heat pumps. Model 400 can be installed on heat pumps. When heat pumps deliver lower temperature air than gas furnaces, evaporation will be approximately 60% of rated capacity.

Water Usage Rate: Models 300 is 6 gph; Models 500, 600 and 700 are 3 gph; Model 400 is 0.7 gph; Model 800 is 0.6 to 1.8 gph depending on voltage, amp draw and water quality.

Warranty: 5 Year Warranty on most models.

Regional Humidifier Applications

Aprilaire humidifiers can be installed on various HVAC systems. Selection depends on geography and heating equipment.

CLIMATE ZONE/RECOMMENDED APRILAIRE HUMIDIFIER SOLUTION BY MODELMIDWEST/ NORTHEASTMID-ATLANTIC/ MID-SOUTHERNMOUNTAINSOUTHDESERT (SOUTHWEST)
Equipment
Gas/Oil Furnace-Single Stage or Multi Stage*400/500/600/700/800400/500/600/700/800400/500/600/700/800500/600/700/800800
Gas/Oil Modulating Furnace**700/800700/800700/800700/800800
Heat Pump/Geo-Single Stage or Multi Stage*400/500/600/700/800400/500/600/700/800400/500/600/700/800500/600/700/800800
Heat Pump/Geo-Modulating**700/800700/800700/800700/800800
Boiler With AHU (No Heat Source)800800800800800
Boiler With AHU and Hot Water Coil/Hydro Air Unit Boiler700/800700/800800800800
Electric Baseboard Heating300/865300/865300/865300/865300/865
Humidifying with A/C Unit800800800800800

*PSC, constant torque ECM **Variable speed ECM

Evaporative performance of bypass humidifiers decreases with lower airflow volume and lower air temperature. Bypass models can be used in these applications if the HVAC system pressure differential between supply and return ducts is at least 0.08 in. wg and air temperature, hot water and continuous fan in the supply duct is at least 100°F.

Dehumidifiers

Aprilaire dehumidifiers are part of the Aprilaire Healthy Air System, designed to manage humidity levels.

ModelUnit Size (W x H x L)Capacity (ppd = Pints Per Day)Airflow @ 0.0" w.c. (CFM)Airflow @ 0.2" w.c. (CFM)Airflow @ 0.4" w.c. (CFM)Unit Weight (lbs.)Warranty
E07012.5" x 12.5" x 25"70 ppd200 CFM170 CFM140 CFM565 Year
E08014" x 15" x 26"80 ppd185 CFM135 CFM85 CFM635 Year
E10014" x 15" x 26"100 ppd280 CFM245 CFM210 CFM645 Year
E13019.75" x 18.75" x 30"130 ppd310 CFM270 CFM225 CFM985 Year

Dehumidifier Sizing Guidelines (Recommended home floor area in ft²):

ModelStructure TightnessRegion A (Most Humid)Region BRegion C (Less Humid)
E080Loose2,600 Ft²3,900 Ft²2,300 Ft²
Tight3,200 Ft²4,400 Ft²4,000 Ft²
E100Loose3,200 Ft²5,000 Ft²3,900 Ft²
Tight4,000 Ft²5,500 Ft²5,200 Ft²
E130Loose1,600 Ft²3,000 Ft²2,300 Ft²
Tight2,300 Ft²3,600 Ft²3,200 Ft²

Actual home size depends on location, ventilation rate, occupant habits, AC system moisture removal, and comfort conditions. For on-demand sizing recommendations, use the Dehumidifier Selection Assistant at aprilaires.com/dsa.

Air Filtration

Aprilaire offers a range of air cleaners and filters as part of the Healthy Air System.

Air Cleaners

SeriesModelNominal Size (in Inches)Cabinet Size (W x H x D)Shipping Weight (lbs)Included Filter
2000 Series#221620 x 256.75" x 22.06" x 27.38"20MERV 16
2000 Series#241616 x 256.75" x 17.75" x 30.06"19.25MERV 16
2000 Series#251631 x 286.75" x 31" x 30.06"24.9MERV 16
2000 Series#221020 x 256.75" x 22.06" x 27.38"19MERV 13
2000 Series#231020 x 206.75" x 20.38" x 22.06"17MERV 13
2000 Series#241016 x 256.75" x 17.75" x 30.06"19MERV 13
1000 Series#111016 x 206.75" x 17.75" x 22.06"13MERV 11
1000 Series#121020 x 256.75" x 22.06" x 27.38"20MERV 11
1000 Series#131020 x 206.75" x 20.38" x 22.06"15MERV 11
1000 Series#141016 x 256.75" x 17.75" x 30.06"19MERV 11
1000 Series#151031 x 286.75" x 31" x 30.06"28MERV 11
1000 Series#191025 x 206.75" x 25.06" x 22.06"18MERV 11
5000 SeriesELECTRONIC Air Cleaner 50116 x 2515.94" x 17.81" x 30.19"31MERV 11
5000 SeriesELECTRONIC Air Cleaner 500020 x 2515.94" x 22.13" x 27.38"32.4MERV 11

Filter Grille Air Cleaners

Model No.Nominal Size (in Inches)Filter ModelShipping WeightWarranty
1625FG1116 x 2561016 lbs.5 Year
1625FG1316 x 2561318 lbs.5 Year
2025FG1120 x 2581016 lbs.5 Year
2025FG1320 x 2581318 lbs.5 Year

Note: Recommended grille face velocity is 300-450 fpm. For systems over 3.5 tons, use two filter grilles to minimize noise risk.

Air Cleaner Filters

Aprilaire offers various filters for their air cleaners.

Pressure Drop Chart (Static Pressures at Variable CFM in. w.c.)

Filter No.MERV Rating200 CFM400 CFM600 CFM800 CFM1000 CFM1200 CFM1400 CFM1600 CFM1800 CFM2000 CFM2200 CFM2400 CFM2600 CFM2800 CFM3000 CFM
216MERV 16 ALLERGY & ASTHMA0.060.090.130.170.230.290.36
4160.070.100.130.180.240.31
5160.040.050.070.090.100.130.150.180.210.240.270.31
113MERV 13 HEALTHY HOME0.030.070.110.160.220.29
2130.020.040.060.090.120.150.190.230.270.31
3130.030.050.090.130.170.23
4130.020.050.070.100.140.170.220.260.310.37
5130.010.020.040.050.050.070.080.100.110.130.150.170.180.200.23
6130.020.050.070.100.140.170.220.260.310.37
8130.020.040.060.090.120.150.190.230.270.31
913MERV 13 ODOR REDUCTION0.040.070.100.130.170.220.250.300.35
213CBN0.040.070.100.130.170.210.250.300.35
413CBN0.040.070.100.140.190.240.290.360.43
513CBN0.030.040.050.070.080.100.120.150.170.200.220.250.290.32
110MERV 11 CLEAN AIR0.020.050.060.100.140.20
2100.020.030.040.060.080.110.130.160.190.22
3100.020.040.060.100.140.19
4100.020.030.050.070.090.120.150.190.220.27
5100.020.020.030.040.040.050.060.070.090.100.120.140.150.170.19
6100.020.030.050.070.090.120.150.190.220.27
8100.020.030.040.060.080.110.130.160.190.22
910-0.030.050.070.090.120.150.180.220.27
EAC MERV 102010.020.040.050.080.100.120.150.180.210.25
4010.020.040.050.080.100.140.170.210.250.29
5010.020.040.050.080.100.140.170.210.250.29

Removal Efficiency (Based on Particle Size)

MERV Rating0.3-1.0 Microns1.0-3.0 Microns3.0-10.0 Microns
MERV 1695%98%99%
MERV 1363%88%93%
MERV 1137%67%92%
MERV 1022%56%92%
EAC (Model 5000)89%95%98%

Test Method: MERV 10-16 = ASHRAE 52.2.2012, EAC = AHRI 680-2009

Upgrade Kits

ModelNominal Size (in inches)Compatible WithIncluded FilterRails Model NumberStatic Pressure Drop (in. w.c.) @ 1200 CFMMaximum Airflow Capacity (in CFM)
#121320 x 25Aprilaire/Space-Gard 220021348930.152000
#141316 x 25Aprilaire/Space-Gard 240041348940.172000

Upgrade Rails

ModelNominal Size (in inches)Compatible WithUses Filter ModelMaximum Airflow Capacity (in CFM)
#489320x25Aprilaire/Space-Gard 2200 or 2120210, 213, 213CBN2000
#489416x25Aprilaire/Space-Gard 2400 or 2140410, 413, 413CBN2000
#489716x25Models by (but not limited to): Carrier®, Honeywell®, Lennox®, Ultravation®, General®, Trion®610, 6132000
#489820x25Models by (but not limited to): Carrier®, Honeywell®, Lennox®, Ultravation®, General®, Trion®810, 8132000

Replacement Filters

Filter No.Used with Aprilaire Air Cleaner ModelsNominal Size (in inches)Static Pressure Drop (in. w.c.) @ 1200 CFMMaximum Airflow Capacity (in CFM)
201Aprilaire/Space-Gard* 220020 x 250.122000
401Aprilaire/Space-Gard* 240016 x 250.142000

*Air Cleaner models no longer available.

Healthy Air Controls (Thermostats)

Aprilaire offers a range of thermostats for controlling your home's climate and air quality.

TypeResidential Model No.StagesHome Automation Model No.Dimensions (W x H x D)Key Features
NonProgrammable84441H/1C-5.25" x 4.5" x 1"Easy to Read Display, Simple Setup, Displays Outdoor Temperature (if equipped), Adjustable Differential, Progressive Recovery, Heat Blast
84462H/1C HP-
84482H/2C, 4H/2C HP-
Programmable84631H/1C-5.25" x 4.5" x 1"Easy to Read Display, Simple Setup, Displays Outdoor Temperature (if equipped), Adjustable Differential, Progressive Recovery, Heat Blast
84652H/1C HP-
84662H/2C, 4H/2C HP-
Programmable with Event-BasedTM Air Cleaning84762H/2C, 4H/2C HP8476W**5.25" x 4.5" x 1"Event-Based™ Air Cleaning, Air Cleaning Notice, Change Filter Alert
Programmable Touch Screen86002H/2C, 4H/2C HP88006" x 4.94" x 1.94"Displays Indoor RH, Energizes HVAC Blower for Humidity Controls, Humidifier with 24 VAC Dry Contact Controls, Whole-Home Dehumidifier Controls, A/C Equipment for Dehumidification
86202H/2C, 4H/2C HP8620W**6" x 4.94" x 1.94"Displays Indoor RH, Energizes HVAC Blower for Humidity Controls, Humidifier with 24 VAC Dry Contact Controls, Whole-Home Dehumidifier Controls, A/C Equipment for Dehumidification
Programmable Touch Screen with Humidity Control89103H/3C, 4H/2C HP8910W**6" x 4.94" x 1.19"Displays Indoor RH, "Dehumidifier On" Notice, Energizes HVAC Blower for Dehumidification, Humidifier with 24 VAC Dry Contact Controls, Dehumidifier Controls, Ventilation Control
89203H/3C, 4H/2C HP8920W**7.1" x 4.94" x 1"Programmable for Timed Ventilation, Programmable for ASHRAE 62.2 Ventilation, Configurable Temperature and Humidity Limits, "Ventilation On" Notice

** Wi-Fi compatible and compatible

IAQ Control Equipment Module: Controls Air Cleaner and Humid or Dehumid or Vent. Wired Outdoor Temperature Sensor Included.

Zone Control Systems

Aprilaire offers zone control systems to manage comfort in different areas of the home.

6000 Series Product Configurations

TypeModelDescription
Kits60102-Zone Complete Kit* (Black)
60152-Zone Complete Kit* (White)
60203-Zone Complete Kit* (Black)
60253-Zone Complete Kit* (White)
Individual Components60302-Zone Base
60403-Zone Base
6050Secondary Zone UI
60352-Zone Base
60453-Zone Base
6055Secondary Zone UI

* Kits include outdoor temperature sensor along with duct probe.

Zone Control Panels

ModelSpecificationsOverall Dimensions (W x H x D)HumidityOperating TemperatureShipping TemperatureVoltageMaximum Current
Universal64044 Zone Universal Multistage (Can be expanded to 12 zones with Model 6401) + Compatible with Model 8056 wireless outdoor sensor8.63" W x 14.81" H x 1.4" D5%-90% RH, non-condensing32°F–158°F-40°F–180°F18-30VAC 50/60 HzDamper output per zone (fused): 18VA at 158°F, 30VA at 90°F; Zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; Zone panel consumption: 4VA max
64033 Zone Universal Multistage + 2 Heat 2 Cool or 4 Heat 2 Cool (Heat Pump) + Compatible with Model 8056 wireless outdoor sensor8.63" W x 9.94" H x 1.4" D5%-90% RH, non-condensing32°F–158°F-40°F–180°F18-30VAC 50/60 HzDamper output per zone (fused): 18VA at 158°F, 30VA at 90°F; Zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; Zone panel consumption: 4VA max
Heat Pump Only63033 Zone Heat Pump + 2 Heat 1 Cool Single Stage8.63" W x 9.94" H x 1.4" D5%-90% RH, non-condensing32°F–158°F-40°F–180°F18-30VAC 50/60 HzDamper output per zone (fused): 18VA at 158°F, 30VA at 90°F; Zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; Zone panel consumption: 4VA max
63022 Zone Heat Pump + 2 Heat 1 Cool Single Stage8.63" W x 9.94" H x 1.4" D5%-90% RH, non-condensing32°F–158°F-40°F–180°F18-30VAC 50/60 HzDamper output per zone (fused): 18VA at 158°F, 30VA at 90°F; Zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; Zone panel consumption: 4VA max
Conventional Only62033 Zone Heat/Cool + 1 Heat 1 Cool Single Stage8.63" W x 9.94" H x 1.4" D5%-90% RH, non-condensing32°F–158°F-40°F–180°F18-30VAC 50/60 HzDamper output per zone (fused): 18VA at 158°F, 30VA at 90°F; Zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; Zone panel consumption: 4VA max
62022 Zone Heat/Cool + 1 Heat 1 Cool Single Stage8.63" W x 9.94" H x 1.4" D5%-90% RH, non-condensing32°F–158°F-40°F–180°F18-30VAC 50/60 HzDamper output per zone (fused): 18VA at 158°F, 30VA at 90°F; Zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; Zone panel consumption: 4VA max

Note: Use 18 or 20 AWG solid (non-stranded) wire. Zoned Comfort Control™ Kits include: Zone panel, 6" duct probe and 24V 40VA universal transformer.

Zone Dampers

Rectangular Damper Size & Stock No.

Nominal Width (in inches)8"10"12"14"16"18"20"22"24"26"28"30"
8" (Side Mount)672167226723672467256726672767286729673067316753
8" (Side Mount W3)6721W36722W36723W36724W36725W36726W36727W36728W36729W36730W36731W36753W3
10" (Side Mount)67326733673467356736673767386739674067416742
10" (Side Mount W3)6732W36733W36734W36735W36736W36737W36738W36739W36740W36741W36742W3
12" (Side Mount)6743674467456746674767486749675067516752
12" (Side Mount W3)6743W36744W36745W36746W36747W36748W36749W36750W36751W36752W3
14" (Side Mount)675467556756675767586759676067616762
14" (Side Mount W3)6754W36755W36756W36757W36758W36759W36760W36761W36762W3
16" (Side Mount)67636764676567666767676867696770
16" (Side Mount W3)6763W3
18" (Side Mount)6771677267736774677567766777
20" (Side Mount)677867796780678167826783
22" (Side Mount)67846785678667876788
24" (Side Mount)6789679067916792
26" (Side Mount)679367946795
28" (Side Mount)67966797
30" (Side Mount)6798
8" (Bottom Mount)672168126813681468156816681768186819
8" (Bottom Mount W3)6721W36812W36813W36814W36815W36816W36817W36818W36819W3
10" (Bottom Mount)67326823682468256826682768286829
10" (Bottom Mount W3)6732W36823W36824W36825W36826W36827W36828W36829W3
12" (Bottom Mount)6743683468356836683768386839
12" (Bottom Mount W3)6743W36834W36835W36836W36837W36838W36839W3

Round Damper Size & Stock No.

Nominal Diameter (in inches)4"5"6"7"8"9"10"12"14"16"18"20"
Zone Damper (Normally open/power closed)6606660766086609661066126614661666186620
Zone Damper (Normally open/power closed W3)6606W36607W36608W36609W36610W36612W36614W36616W36618W36620W3
Ventilation Damper (Normally closed/ power opened)650665086510
Barometric Pressure Relief (Air flow activated)61086110611261146116
Static Pressure Relief (Power activated)6208621062126214621662186220
Round Slip-In Damper (Normally open/power closed)670467056706670767086710

Note: Rectangular Damper Dimension = Nominal width + 3.5". Round Damper Dimension = Nominal diameter + 4.5". 10 day lead time for shaded items.

Fresh Air Ventilation

Aprilaire offers ventilators and ventilating dehumidifiers for fresh air intake.

Ventilating Dehumidifiers

ModelUnit Size (W x H x L)Shipping Weight (lbs.)Airflow @ 0.2 in. w.c. (CFM)Description
#E100V + 8190FFE100V: 14.5" x 23.5" x 48.25"82.00 (E100V)100The Ventilating Dehumidifier brings in fresh air to meet ventilation needs while removing excess humidity from the incoming outdoor air.
#8192AW: 15" H: 14" L: 26"16.80150Features an integrated ventilation control. Draws fresh air into the home by energizing its fan and opening its vent damper. If incoming air is above a set relative humidity percentage, the outside air is dehumidified. *Dehumidification Capacity 100 Pints Per Day.

Fresh Air Ventilators

ModelUnit Size (W x H x L/D)Shipping Weight (lbs.)Airflow (CFM)Description
#8145W: 12.25" H: 11.75" L: 23.4"14.50210Delivers fresh air into the return or supply duct by energizing its fan and opening its integrated damper. Features an 8120X ventilation controller.
#8145NCW: 13.2" H: 6.7" L: 11.9"21.00210No on-board controller; ventilation controlled via thermostat.
#8145KW: 13.2" H: 6.7" L: 11.9"11.50210Includes 8145NC, 8120X control, inlet hood, and start collar for adding ventilation to existing homes.
#8142W: 10.25" H: 18.13" D: 10.25"20.50130Delivers fresh air into the return or supply duct. Features an 8120X ventilation controller.
#8142NCW: 10.25" H: 18.13" D: 10.25"10.75130No on-board controller; ventilation controlled via thermostat.
#8144NCW: 10.25" H: 18.13" D: 10.25"20.50130Provides continuous low-volume ventilation for smaller homes. A separate 8120X controller can be added.

Ventilation Controller

ModelUnit Size (W x H x D)Description
#8120XW: 4.11" H: 3.6" D: 1.59"Engages a fan or damper on ventilation solutions to deliver fresh air. Programmable for code requirements or set high/low outdoor temperature and indoor RH limits.
#8126XW: 10.8" H: 10.75" D: 6"Includes a powered damper, ventilation controller, and installation accessories. Mounts on the return side of the HVAC blower.

Kitchen Ventilation Kits

ModelUnit Size (W x H x D)Airflow (CFM)
#6508KVW: 8" H: 10.75" D: 12.25"185
#6510KVW: 10" H: 10.75" D: 14.25"390

Fresh Air Exchanger (ERV)

ModelUnit Size (W x H x D)Shipping Weight (lbs.)Airflow (CFM)Description
#8100W: 37.38" H: 20.7" D: 12.75"87.00130Draws in fresh outdoor air and exhausts stale indoor air, transferring energy (heating or cooling) and moisture between air streams. Requires a separate ventilation controller or thermostat.

Accessories

Aprilaire offers various accessories for their systems.

ModelProduct DescriptionUnit SizeType of WireCompatible Models
#8051Flush Mount SensorDisk: 1.5" dia. Friction fit in a 1" opening. Air gap of 0.25" required.18-24 gauge 2 conductor wire (or more conductors)8600, 8620, 8620W, 8910, 8910W, 8920W, 8800, 8820, 8830, 8840
#8052Outdoor/Duct SensorProbe: 0.25" dia. x 1.75" L Bracket: 0.75" x 0.75"18-24 gauge 2 conductor wire (or more conductors)All thermostats
#8053Surface Mount SensorW: 3.75" H: 2.5" D: 0.875"18-24 gauge 2 conductor wire (or more conductors)All thermostats
#80223-Wire to 4-Wire AdapterW: 2.875" H: 1.75" D: 1.475"18-22 gauge stranded or solid thermostat wireAll thermostats
#8028Damper Power Distribution PanelW: 10.5" H: 5" D: 1.7"All zone control panels
#6401Expansion PanelW: 10.5" H: 5" D: 1.7"Supports 2-wire or 3-wire dampers6404 With LCD screen
#8081Temperature Support ModuleW: 3.5" H: 2.5" D: 0.875"Cat 6 or greater8800, 8820, 8830, 8840
#8082Temperature and RH Support ModuleW: 3.5" H: 2.5" D: 0.875"Cat 6 or greater8800, 8820, 8830, 8840
#8083Flush Temperature and RH Support ModuleDisk: 1.5" dia. Cylinder Hole: 1" off wall, 0.25" air gapCat 6 or greater8800, 8820, 8830, 8840

Ventilation Climate Zones & Application Matrix

Managing the quality of ventilated air is critical for a healthy indoor environment, with requirements varying by climate. Aprilaire ventilation solutions work with HVAC equipment to remove moisture, particulates, and contaminants.

Ventilation Climate Zones

SOURCE: 2012 & 2015 International Residential Code §N1101.10 (R301.1). Zones are by county, based on factors including mean temperature, warmest month, precipitation and wet bulb temperature.

Use the map and application guide to determine the recommended product solution for your climate, considering moisture removal, energy savings, and HVAC integration.

Ventilation Supply Solutions: Aprilaire Ventilation Application Matrix

ZONECLIMATE TYPEMAJOR CITIESPRIMARY SOLUTION¹FRESH AIR DUCTED²ECONOMY- OR COMFORTFOCUSED SOLUTIONMULTI-FAMILY NEW CONSTRUCTION SOLUTION
1Hot & MoistMiamiE100V + 8190FF or 8192A (Dehumidifies incoming ventilation air)HVAC Return8145 or 8126X8144NC
2Hot & MoistOrlando, Mobile, New Orleans, Houston, Austin, San AntonioE100V + 8190FF or 8192A (Dehumidifies incoming ventilation air)HVAC Return8145 or 8126X8144NC
2Hot & DryPhoenix, Tucson8142 (Mixes ventilation air after cooling or heating)HVAC Supply8126X8144NC
3Warm & MoistCharlotte, Charleston, Atlanta, Little Rock, Oklahoma City, DFWE100V + 8190FF or 8192A (Dehumidifies incoming ventilation air)HVAC Supply8145 or 8126X8144NC
3Warm & DryEl Paso, Las Vegas, Los Angeles, Sacramento8142 (Mixes ventilation air after cooling or heating)HVAC Supply8145 or 8126X8144NC
3Warm & MarineSan Francisco, San Jose8142 (Mixes ventilation air after cooling or heating)HVAC Return8126X8144NC
4Mixed & MoistPhiladelphia, Washington DC, Baltimore, Nashville, St. Louis, Wichita, Louisville8145 (Mixes ventilation air prior to cooling or heating)HVAC Supply8145 or 8126X8144NC
4Mixed & DryAlbuquerque, Amarillo8142 (Mixes ventilation air after cooling or heating)HVAC Return8126X8144NC
4Mixed & MarinePortland, Seattle8142 (Mixes ventilation air after cooling or heating)HVAC Return8126X8144NC
5Cool & MoistBoston, Pittsburgh, Columbus, Indianapolis, Detroit, Chicago, Des Moines, Omaha8145 (Mixes ventilation air prior to cooling or heating)HVAC Return8126X8144NC
5Cool & DryDenver, Salt Lake City, Boise, Reno8145 (Mixes ventilation air prior to cooling or heating)HVAC Return8126X8144NC
6Cold & MoistToronto, Vancouver, Milwaukee, Madison, Minneapolis-St Paul, Sioux Falls8145 (Mixes ventilation air prior to cooling or heating)HVAC Return8126X8144NC
6Cold & DryHelena, Cheyenne8145 (Mixes ventilation air prior to cooling or heating)HVAC Return8126X8144NC
7Extreme Cold & MoistFargo, Duluth, Calgary, Edmonton8145 (Mixes ventilation air prior to cooling or heating)HVAC Return8126X8144NC

¹ Primary Aprilaire recommended supply ventilation solution for optimal performance and building code adherence. ² HVAC application considerations based upon moist versus dry air, and proper mixing into the ductwork.

Effective Virus Protection

Install the Aprilaire Healthy Air System™ today!

Visit AprilairePartners.com for more information.

PDF preview unavailable. Download the PDF instead.

400-A-Broc Adobe PDF Library 15.0 Adobe InDesign 16.3 (Macintosh)

Related Documents

Preview AprilAire Healthy Air Solutions Product Guide
Comprehensive product guide for AprilAire's Healthy Air solutions, including radon mitigation, humidification, dehumidification, air filtration, ventilation, and smart controls for residential and commercial applications.
Preview Aprilaire Indoor Air Quality Systems: Humidifiers, Dehumidifiers, Air Cleaners, and Ventilation
Comprehensive guide to Aprilaire's range of indoor air quality products, including humidifiers, dehumidifiers, air cleaners, thermostats, zone control systems, and ventilation solutions, with detailed specifications and application guidance.
Preview AprilAire Healthy Air Solutions Product Guide
Comprehensive guide to AprilAire's range of healthy air solutions including radon mitigation, humidification, dehumidification, air filtration, ventilation, and zone control systems, with detailed product specifications and application guidance.
Preview AprilAire E100V/8190FF Ventilating Dehumidifier Specification Sheet
Detailed specifications and benefits of the AprilAire E100V/8190FF Ventilating Dehumidifier, designed to improve indoor air quality by removing excess moisture and providing ventilation.
Preview AprilAire Healthy Air Solutions Product Guide
A comprehensive quick reference guide to AprilAire's Healthy Air solutions, detailing products for radon mitigation, humidification, dehumidification, air filtration, ventilation, and zone control systems. Includes specifications, sizing guidelines, and application recommendations.
Preview Aprilaire Fresh Air Ventilation: Product & Application Guide
A comprehensive guide to Aprilaire's range of fresh air ventilation products, including whole-home ventilators, controllers, and energy recovery ventilators (ERVs), designed for enhanced indoor air quality, comfort, and energy efficiency in residential and light commercial applications.
Preview Aprilaire 8400 Series Thermostats: Features and Comparisons
Explore the full-featured, contractor-exclusive Aprilaire 8400 Series thermostats. Compare models 8463, 8465, 8466, and 8476 with key features like large backlit displays, dual power, 5-year warranties, and advanced IAQ circulation modes. Includes a detailed product comparison table.
Preview AprilAire Air Cleaners: Superior Filtration, Airflow, and IAQ
Explore the benefits of AprilAire whole-home air cleaners, focusing on reduced static pressure, improved airflow, high particle removal efficiency (MERV 11, 13, 16), and long-term system protection. Learn about AprilAire's advanced filtration technologies and product specifications.