AprilAire Healthy Air Solutions

Quick Reference | May 2023

AprilAire Healthy Air Solutions

AprilAire provides professional-grade Healthy Air solutions. The company's mission is to enhance people's health by improving the air in their homes, recognizing that Healthy Air is essential to a healthy lifestyle and overall well-being. Solutions are inspired by consumer needs and the expertise of professional contractors.

AprilAire is Healthy Air.

Features a 5-year warranty on all installed products.

Key Solution Areas: Radon Mitigation, Air Filtration, UVC, Fresh Air Ventilation, Humidification, Dehumidification, Zone Control.

Radon Mitigation Fans

AprilAire Radon Mitigation Fans are specifically designed for radon mitigation, offering superb performance and ultra-quiet operation.

Features

  • Energy efficient
  • Ultra-quiet operation
  • Meets all electrical code requirements
  • Housing that stays white
  • Water-hardened motorized impeller
  • Seams sealed to inhibit radon leakage (ARN15F/ARN25F double snap sealed)
  • ETL Listed - for indoor or outdoor use
  • Thermally protected motor
  • Rated for commercial and residential use
  • Patent pending design
  • Optimal for moderate to tight soils (ARNHPF Only)
  • Technology to inhibit radon and soil gas leakage
  • ETL listed by Intertek to UL507 and CSA C22.2 Standards

Models and Specifications

Dimensions:

  • ARN15F: 9.7" H x 8.5" W
  • ARN25F: 11.75" H x 8.6" W
  • ARNHPF: 11.9" H x 10.9" W
MODELFAN DIAMETERRECOMMENDED DUCTWATTSTYPICAL CFM vs. STATIC PRESSURE " WC
0.20.51.01.52.02.53.03.54.0
ARN15F4"41-721.716612682413----
ARN25F6"70-1702.337534028220414070---
ARNHPF3"70-1704.0-11097887968543614

Mitigation Kits

MODELSlab sizeFan TypeDimensions DxHColorFan Duct DiameterPressure
ARN15K<1500 sq. ft.RF1, RF29.7 x 8.5White4"1.7 WC
ARN25K1500-2500 sq. ft.-11.75 x 8.6White6"2.3 WC
ARNHPKModerate to Tight Soil-11.9 x 10.9White3"4.0 WC

Radon Accessories

ACCESSORYDESCRIPTION
Manometer P/N ARN05MMounts to the outside of PVC pipe on a radon mitigation system and measures vacuum pressure in real time, helping to indicate potential issues with the fan. It can serve as a secondary indicator that vacuum pressure has changed in the event of a system alarm going off, helping to confirm that it's not a false alarm.
Transition Fitting P/N ARNTF4Consolidates the number of fittings needed in outdoor radon mitigation system installations. Connects a 4" fan pipe to a 4" exhaust pipe with a weir (not included) for capturing and draining condensate. Weir is included in the Condensate Bypass Kit.
Condensate Bypass Kit P/N ARNCBKDesigned to drain condensation around the fan in outdoor installs.
Radon-T Fitting P/N ARNSITDesigned for use in adding radon mitigation to new construction and crawl spaces. Provides 4-way airflow, allowing moisture and soil gases to be drawn from all angles.
System Alarm P/N ARNALMAdvanced vacuum monitoring device utilizing piezoresistive pressure sensor (PPS) technology. It provides homeowners with an easy-to-read, easy-to-use system alarm that requires no interpretation.

Humidity Control - Humidifiers

Humidifiers are part of the AprilAire Healthy Air System.

Types of Humidification

HUMIDIFIERSTYPE OF HUMIDIFICATIONUNIT SIZE (W x H x D)PLENUM OPENINGCAPACITY (GPD)ELECTRICAL DATA
#800*Steam10 1/8" x 20 7/8" x 7 1/8"-11.5 GPD120 VAC 60HZ 11.5A
#801***Fan Pack: 14" x 6 29/32" x 3 15/16"
Finished Grille: 16 3/16" x 9" x 1 3/32"
-16.0 GPD120 VAC 60HZ 16.0A
#865**15 29/32" x 18" x 10 11/32"-20.5 GPD208 VAC 60HZ 11.5A
#866***-30.0 GPD208 VAC 60HZ 16.0A
#700*Fan Powered Evaporative23.3 GPD240 VAC 60HZ 11.5A
#700M**34.6 GPD240 VAC 60HZ 16.0A
#600*Large Bypass EvaporativeW: 14 3/4" H: 14 31/100"18 GPD120 VAC 60HZ 0.8A
#600M**
#500*Small Bypass EvaporativeW: 10" H: 12 3/4"6" dia. round opening17 GPD24 VAC 60HZ 0.5A
#500M**W: 9 1/2" H: 9 1/2"6" dia. round opening12 GPD24 VAC 60HZ 0.5A
#400*Water Saver Bypass EvaporativeW: 10" H: 12 3/4"6" dia. round opening17 GPD24 VAC 60HZ 0.5A
#400M**See note on heat pumps13 GPD120 VAC 60HZ 0.7A
#300Self-Contained Evaporative14 3/8" x 12 1/2" x 22 3/32"

*Automatic Digital Control (shown)
**Manual Control - For those rare occurrences where an automatic control is not practical, AprilAire offers the same great humidifiers with a manual control.
***801 & 866 Modulating Steam Humidifier - For precise RH control. Controls are sold separately.

Heat Pumps: Model 400 can be installed in heat pump applications. Due to lower temperature air from heat pumps, evaporation is approximately 60% of rated capacity. Consult your dealer for sizing considerations.

Model 800LC: Available with 80LC canister for less conductive water (75-300 µS/cm) and 120VAC applications.

GPD: Gallons Per Day, as recommended by AHRI. Evaporative capacities assume blower is active 100% of the time, plenum temperature is at 120°F and water is cold.

Water Usage Rate: Model 300 is 6 gph; Models 500, 600 and 700 are 3 gph; Model 400 is 0.7 gph; Model 800 is 0.6 to 1.8 gph depending on voltage, amp draw and water quality.

Humidifier Sizing Guidelines

GPD Needed Per Square Foot Based on Building Structure Tightness

VOLUME OF BUILDING (FT³)BUILDING FLOOR AREA (FT²) WITH 8 FT CEILINGSGPD NEEDED
TightAverageLoose
800010003.36.710.0
1200015005.010.015.0
1600020006.713.420.0
2000025008.316.725.0
24000300010.020.030.1
32000400013.426.740.1
40000500016.733.450.1

Regional Humidifier Applications

AprilAire humidifiers can be installed on many different types of HVAC equipment. This application guide assists in selecting the appropriate AprilAire product based upon geography and heating equipment. It is important to consider plenum temperature, air flow (fan speed) and run time (heat call primary, fan only call secondary) when selecting products.

Automatic humidity controls have an integrated blower activation feature. Installations with a manual humidifier control can increase capacity by turning the thermostat fan to "ON". When installing evaporative humidifiers, it is recommended they are plumbed to hot water.

CLIMATE ZONE/RECOMMENDED APRILAIRE HUMIDIFIER SOLUTION BY MODELMIDWEST/ NORTHEASTMID-ATLANTIC/ MID-SOUTHERNMOUNTAINSOUTHDESERT (SOUTHWEST)
Gas/Oil Furnace-Single Stage or Multi Stage*400/500/600/700/800400/500/600/700/800400/500/600/700/800500/600/700/800800
Gas/Oil Modulating Furnace**700/800700/800700/800700/800800
Heat Pump/Geo-Single Stage or Multi Stage*400/500/600/700/800400/500/600/700/800400/500/600/700/800500/600/700/800800
Heat Pump/Geo-Modulating**700/800700/800700/800700/800800
Boiler With AHU (No Heat Source)800800800800800
Boiler With AHU and Hot Water Coil/ Hydro Air Unit700/800700/800800800800
Boiler300/865300/865300/865300/865300/865
Electric Baseboard Heating300/865300/865300/865300/865300/865
Humidifying with A/C Unit800800800800800

*PSC, constant torque ECM
**Variable speed ECM
Evaporative performance of bypass humidifiers decreases with lower airflow volume and lower air temperature. Bypass models can be used in these applications if the HVAC system pressure differential between supply and return ducts is at least 0.08 in. wg and air temperature, hot water and continuous fan in the supply duct is at least 100°F.

Humidity Control - Dehumidifiers

Dehumidifiers are part of the AprilAire Healthy Air System.

MODELUNIT SIZE (W x H x L)CAPACITY (PPD)AIRFLOW @ VARYING E.S.P. (EXTERNAL STATIC PRESSURE - DRY COIL)UNIT WEIGHT (LBS.)
@80°F/60%RH@73°F/60%RH0.0" w.c.0.2" w.c.0.4" w.c.
#E07012½" x 12½" x 25"70 ppd53 ppd200 CFM170 CFM140 CFM56
#E08014" x 15" x 26"80 ppd65 ppd185 CFM135 CFM85 CFM63
#E080H1
#E10014" x 15" x 26"100 ppd85 ppd280 CFM245 CFM210 CFM64
#E100C2
#E13019½" x 18½" x 30"130 ppd105 ppd310 CFM270 CFM225 CFM98
#E130H1
#E130C2

Note: E080H1, E100H and E130H are hardwired units. E100C2 and E130C are on casters.

Dehumidifier Sizing Guidelines

The recommended home floor area (ft²) that each listed dehumidifier can dehumidify is for sizing guidelines only. Actual home size depends on location, ventilation rate, occupant habits, AC system moisture removal, and comfort conditions.

REGIONMODELRECOMMENDED HOME FLOOR AREA (FT²)
LOOSETIGHT
REGION A (Most Humid)MODEL E0803,200 Ft²4,400 Ft²
MODEL E1004,000 Ft²5,500 Ft²
MODEL E1305,200 Ft²7,200 Ft²
REGION B (Moderately Humid)MODEL E0802,600 Ft²3,900 Ft²
MODEL E1003,200 Ft²5,000 Ft²
MODEL E1303,900 Ft²6,500 Ft²
REGION C (Less Humid)MODEL E0801,600 Ft²2,300 Ft²
MODEL E1002,000 Ft²3,000 Ft²
MODEL E1302,300 Ft²3,600 Ft²

Provide on-demand sizing recommendations using the Dehumidifier Selection Assistant at AprilAirepartners.com/dsa.

Air Filtration - Air Cleaners

Air Cleaners are part of the AprilAire Healthy Air System.

AIR CLEANERSNOMINAL SIZE (IN INCHES)CABINET SIZE (W x H x D)SHIPPING WEIGHT (LBS)INCLUDED FILTERCOMPATIBLE FILTERS*
#221620 x 256 3/4" x 22 1/16" x 27 3/8"20MERV 16 (216)216, 213CBN, 210
#241616 x 256 3/4" x 17 3/4" x 30 1/16"19.25MERV 16 (416)416, 413CBN, 410
#251631 x 286 3/4" x 31" x 30 1/16"24.9MERV 16 (516)516, 513CBN, 510
#221020 x 256 3/4" x 22 1/16" x 27 3/8"19MERV 10 (210)210, 213CBN, 213
#231020 x 206 3/4" x 20 3/8" x 22 1/16"17MERV 10 (310)310, 313
#241016 x 256 3/4" x 17 3/4" x 30 1/16"19MERV 10 (410)410, 413CBN, 413
#111016 x 206 3/4" x 17 3/4" x 22 1/16"13MERV 10 (110)110, 113
#121020 x 256 3/4" x 22 1/16" x 27 3/8"20MERV 10 (210)210, 213CBN, 213
#131020 x 206 3/4" x 20 3/8" x 22 1/16"15MERV 10 (310)310, 313
#141016 x 256 3/4" x 17 3/4" x 30 1/16"19MERV 10 (410)410, 413CBN, 413
#151031 x 286 3/4" x 31" x 30 1/16"28MERV 10 (510)510, 513CBN, 513
#191025 x 206 3/4" x 25 1/16" x 22 1/16"18MERV 10 (910)910, 913
#161016 x 2515 11/16" x 17 13/16" x 30 3/16"31MERV 10 (610)610, 613
#162020 x 2515 11/16" x 22 1/8" x 27 3/8"32.4MERV 10 (810)810, 813
#500016 x 2512" W x 18 3/8" H (front) x 17 3/4" H (back) x 31" D35ELECTRONIC AIR CLEANER (501)501

*Included filter is always available as a replacement.

Air Sanitization - UVC

MODEL #CONTAINSAIR CLEANER SIZE INCLUDED (H x L x W)FILTER
AUV24VUVC Coil Cleaner20" x 25" x 4"210 MERV 11
AUVRPBReplacement UVC Lamp16" x 25" x 4"410 MERV 11
UV121210 Air Cleaner AUV24V UV-C Coil Cleaner20" x 25" x 4"213 MERV 13
UV141410 Air Cleaner AUV24V UV-C Coil Cleaner16" x 25" x 4"413 MERV 13
UV222210 Air Cleaner AUV24V UV-C Coil Cleaner20" x 25" x 4"213 MERV 13
UV242410 Air Cleaner AUV24V UV-C Coil Cleaner16" x 25" x 4"413 MERV 13

Air Filtration - Air Filters

Air Filters are part of the AprilAire Healthy Air System.

Static Pressures at Variable CFM (in. w.c.)

FILTER NO.20040060080010001200140016001800200022002400260028003000
2160.060.090.130.170.230.290.36
4160.070.100.130.180.240.31
5160.040.050.070.090.100.130.150.180.210.240.270.31
1130.030.070.110.160.220.29
2130.020.040.060.090.120.150.190.230.270.31
3130.030.050.090.130.170.23
4130.020.050.070.100.140.170.220.260.310.37
5130.010.020.040.050.050.070.080.100.110.130.150.170.180.200.23
6130.020.050.070.100.140.170.220.260.310.37
8130.020.040.060.090.120.150.190.230.270.31
913-0.030.050.070.090.120.150.180.220.27
213CBN0.040.070.100.130.170.210.250.300.35
413CBN0.040.070.100.140.190.240.290.360.43
513CBN0.030.040.050.070.080.100.120.150.170.200.220.250.290.32
1100.020.050.060.100.140.20
2100.020.030.040.060.080.110.130.160.190.22
3100.020.040.060.100.140.19
4100.020.030.050.070.090.120.150.190.220.27
5100.020.020.030.040.040.050.060.070.090.100.120.140.150.170.19
6100.020.030.050.070.090.120.150.190.220.27
8100.020.030.040.060.080.110.130.160.190.22
910-0.030.050.070.090.120.150.180.220.27
2010.020.040.050.080.100.120.150.180.210.25
4010.020.040.050.080.100.140.170.210.250.29
5010.020.040.050.080.100.140.170.210.250.29

*Highest value shown is maximum recommended airflow capacity.

Removal Efficiency (Based on Particle Size)

MERV RATING0.3 µm - 1.0 µm1.0 µm - 3.0 µm3.0 µm - 10.0 µm
MERV 1695%98%99%
MERV 1363%88%93%
MERV 1137%67%92%
MERV 1022%56%92%
EAC - 500089%95%98%

Test Method: MERV 10-16 ASHRAE 52.2.2012, EAC AHRI 680-2009

Upgrade Kits

NOMINAL SIZE (IN INCHES)COMPATIBLE WITHINCLUDED FILTERRAILS MODEL NUMBERSTATIC PRESSURE DROP (in. w.c.) @ 1200 CFMMAXIMUM AIRFLOW CAPACITY (CFM)
#121320 x 25AprilAire or Space-Gard 2200213 MERV 1348930.152000
#141316 x 25AprilAire or Space-Gard 2400413 MERV 1348940.172000

Upgrade Rails

Nominal Size (in inches)Compatible WithUses Filter ModelMaximum Airflow Capacity (in CFM)
20x25AprilAire or Space-Gard 2200210, 213, 213CBN2000
16x25AprilAire or Space-Gard 2400410, 413, 413CBN2000
16x2516x25 Competitive Cabinets610, 6132000
20x2520x25 Competitive Cabinets810, 8132000
16x2016x20 Competitive Cabinets110, 1131200
20x2020x20 Competitive Cabinets310, 3131200

Replacement Filters

FILTER NO.USED WITH APRILAIRE AIR CLEANER MODELSNOMINAL SIZE (IN INCHES)STATIC PRESSURE DROP (in. w.c.) @ 1200 CFMMAXIMUM AIRFLOW CAPACITY (CFM)
201AprilAire or Space-Gard 2200**20 x 250.122000
401AprilAire or Space-Gard 2400**16 x 250.142000

**Air Cleaner models no longer available.

Healthy Air Controls - Thermostats

Thermostats are part of the AprilAire Healthy Air System.

RESIDENTIAL MODEL NUMBERSTAGESHOME AUTOMATION MODEL NO.Dimensions (W x H x D)FEATURES
S84N1H1C1H/1CProgrammable and Non-Programmable, Easy to Read Display, Temperature Control, Air Cleaning, Simple Setup, Displays Outdoor Temperature (if equipped), Adjustable Differential, Progressive Recovery, Heat Blast, Event-Based™ Air Cleaning, Air Cleaning Notice, Change Filter Alert, Automatic or Manual Humidifier Control, "Humidifier On" Notice
S84NSU1H/1C, 2H/1CProgrammable and Non-Programmable, Easy to Read Display, Temperature Control, Air Cleaning, Simple Setup, Displays Outdoor Temperature (if equipped), Adjustable Differential, Progressive Recovery, Heat Blast, Event-Based™ Air Cleaning, Air Cleaning Notice, Change Filter Alert, Automatic or Manual Humidifier Control, "Humidifier On" Notice
S86NMU2H/2C, 4H/2C HPProgrammable and Non-Programmable, Easy to Read Display, Temperature Control, Air Cleaning, Simple Setup, Displays Outdoor Temperature (if equipped), Adjustable Differential, Progressive Recovery, Heat Blast, Event-Based™ Air Cleaning, Air Cleaning Notice, Change Filter Alert, Automatic or Manual Humidifier Control, "Humidifier On" Notice
S86NMUPR2H/2C, 4H/2C HPProgrammable and Non-Programmable, Easy to Read Display, Temperature Control, Air Cleaning, Simple Setup, Displays Outdoor Temperature (if equipped), Adjustable Differential, Progressive Recovery, Heat Blast, Event-Based™ Air Cleaning, Air Cleaning Notice, Change Filter Alert, Automatic or Manual Humidifier Control, "Humidifier On" Notice
S86WMUPR **2H/2C, 4H/2C HP3.75" x 3.75" x 1.00"Wi-Fi, Programmable and Non-Programmable, Easy to Read Display, Temperature Control, Air Cleaning, Simple Setup, Displays Outdoor Temperature (if equipped), Adjustable Differential, Progressive Recovery, Heat Blast, Event-Based™ Air Cleaning, Air Cleaning Notice, Change Filter Alert, Automatic or Manual Humidifier Control, "Humidifier On" Notice, Displays Indoor RH
8910 8910W**3H/3C, 4H/2C HP4.38" x 4.38" x 0.8"Wi-Fi, Programmable and Non-Programmable, Easy to Read Display, Temperature Control, Air Cleaning, Simple Setup, Displays Outdoor Temperature (if equipped), Adjustable Differential, Progressive Recovery, Heat Blast, Event-Based™ Air Cleaning, Air Cleaning Notice, Change Filter Alert, Automatic or Manual Humidifier Control, "Humidifier On" Notice, Displays Indoor RH
8920W**3H/3C, 4H/2C HP6" x 4.85" x 1.25"Wi-Fi, Programmable and Non-Programmable, Easy to Read Display, Temperature Control, Air Cleaning, Simple Setup, Displays Outdoor Temperature (if equipped), Adjustable Differential, Progressive Recovery, Heat Blast, Event-Based™ Air Cleaning, Air Cleaning Notice, Change Filter Alert, Automatic or Manual Humidifier Control, "Humidifier On" Notice, Displays Indoor RH
IAQ Control Equipment Control Module 8 3/5" x 9 3/5" x 1 9/10"7.1" x 4.85" x 1"Humidifier Control, Energizes HVAC Blower for Humidity, Controls Humidifier with 24 VAC Dry Contact, Dehumidifier Control, Controls Whole-Home Dehumidifier, Controls A/C Equipment for Dehumidification, Senses and Displays Indoor RH, "Dehumidifier On" Notice, Energizes HVAC Blower for Dehumidification, Controls Dehumidifier with 24 VAC Dry Contact, Ventilation Control, Programmable for Timed Ventilation, Programmable for ASHRAE 62.2 Ventilation, Configurable Temperature and Humidity Limits, "Ventilation On" Notice, Controls Air Cleaner and Humid or Dehumid or Vent, Controls Air Cleaner and Humid, Dehumid and Vent, Wired Outdoor Product Configuration, Temperature Sensor Included, Two-Part Design—Only 3 Wires to the Living Space

**Compatible with Wireless Indoor and Outdoor Temperature/RH sensors.

Sensors for Model S86WMUPR only.

Wireless Sensors

MODEL #TYPE OF SENSORCOMMUNICATIONSWIRELESS RANGETEMPERATURE MEASUREMENTHUMIDITY MEASUREMENT RANGE/ ACCURACYBATTERY LIFEBATTERY TYPE
#Z10IDTIndoor Wireless Temperature and Humidity Sensor2.4 GHz35+ feet in typical application*Accuracy: ±2°F (40°F to 105°F), ±5°F outside of this rangeRange: 0.5% to 99.5% RH
Accuracy: ±5% RH between 20% and 80% RH
1 yearLithium CR2032 type
#Z10ODTOutdoor Wireless Temperature and Humidity Sensor2.4 GHz35+ feet in typical application*Range: -40°F to 125°FRange: 0.5% to 99.5% RH
Accuracy: ±5% RH between 20% and 80% RH
2 yearsLithium CR2477 type

*Actual distance varies dependent on number and type of interferences. Refer to signal strength for best results.

Features: Get precise temperature control, reducing hot/cold spots, by averaging an installed thermostat with wireless indoor sensors. Temperature/event scheduling for specific areas of the house possible with wireless sensor installation (indoor sensor only).

Zone Control Panels

MODELSPECIFICATIONSUNIVERSAL ZONED COMFORT CONTROL™ KITS** AVAILABLEHEAT PUMP ONLYCONVENTIONAL ONLY
64044 Zone Universal Multistage (Can be expanded to 12 zones with Model 6401)
2 Heat 2 Cool or 4 Heat 2 Cool (Heat Pump)
Compatible with Model 8056 wireless outdoor sensor
Overall Dimensions: 8 63/100" W x 14 18/25" H x 1 43/50" D
Humidity: 5%-90% RH, non-condensing
Operating Temperature: 32°F–158°F
Shipping Temperature: -40°F–180°F
Voltage: 18-30VAC 50/60 Hz
Maximum Current: Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; zone panel consumption: 4VA max
Note: Use 18 or 20 AWG solid (non-stranded) wire
6404K
64033 Zone Universal Multistage
2 Heat 2 Cool or 4 Heat 2 Cool (Heat Pump)
Compatible with Model 8056 wireless outdoor sensor
Overall Dimensions: 8 63/100" W x 9 33/50" H x 1 43/50" D
Humidity: 5%-90% RH, non-condensing
Operating Temperature: 32°F–158°F
Shipping Temperature: -40°F–180°F
Voltage: 18-30VAC 50/60 Hz
Maximum Current: Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; zone panel consumption: 4VA max
Note: Use 18 or 20 AWG solid (non-stranded) wire
6403K
63033 Zone Heat Pump
2 Heat 1 Cool Single Stage
Overall Dimensions: 8 63/100" W x 9 33/50" H x 1 43/50" D
Humidity: 5% - 90% RH, non-condensing
Operating Temperature: 32°F–158°F
Shipping Temperature: -40°F–180°F
Voltage: 18-30VAC 50/60 Hz
Maximum Current: Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; zone panel consumption: 4VA max
Note: Use 18 or 20 AWG solid (non-stranded) wire
6303K
63022 Zone Heat Pump
2 Heat 1 Cool Single Stage
Overall Dimensions: 8 63/100" W x 9 33/50" H x 1 43/50" D
Humidity: 5% - 90% RH, non-condensing
Operating Temperature: 32°F–158°F
Shipping Temperature: -40°F–180°F
Voltage: 18-30VAC 50/60 Hz
Maximum Current: Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; zone panel consumption: 4VA max
Note: Use 18 or 20 AWG solid (non-stranded) wire
6302K
62033 Zone Heat/Cool
1 Heat 1 Cool Single Stage
Overall Dimensions: 8 63/100" W x 9 33/50" H x 1 43/50" D
Humidity: 5%–90% RH, non-condensing
Operating Temperature: 32°F–158°F
Shipping Temperature: -40°F–180°F
Voltage: 18-30VAC 50/60 Hz
Maximum Current: Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; zone panel consumption: 4VA max
Note: Use 18 or 20 AWG solid (non-stranded) wire
6203K
62022 Zone Heat/Cool
1 Heat 1 Cool Single Stage
Overall Dimensions: 8 63/100" W x 9 33/50" H x 1 43/50" D
Humidity: 5%–90% RH, non-condensing
Operating Temperature: 32°F–158°F
Shipping Temperature: -40°F–180°F
Voltage: 18-30VAC 50/60 Hz
Maximum Current: Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; zone panel consumption: 4VA max
Note: Use 18 or 20 AWG solid (non-stranded) wire
6202K

**Zoned Comfort Control Kits include: Zone panel, 6" duct probe and 24VAC 40VA universal transformer.

Healthy Air Controls - Zone Dampers

RECTANGULAR DAMPER SIZE & STOCK NO.*
NOMINAL WIDTH (IN INCHES)8" (203MM)10" (254MM)12" (305MM)14" (356MM)16" (406MM)18" (457MM)20" (508MM)22" (559MM)24" (610MM)26" (660MM)28" (711MM)30" (762MM)
Side Mount (Motor on short dimension)672167226723672467256726672767286729673067316753
W3 indicates power open/power closed6721W36722W36723W36724W36725W36726W36727W36728W36729W36730W36731W36753W3
10" (254MM)67326733673467356736673767386739674067416742
W3 indicates power open/power closed6732W36733W36734W36735W36736W36737W36738W36739W36740W36741W36742W3
12" (305MM)6743674467456746674767486749675067516752
W3 indicates power open/power closed6743W36744W36745W36746W36747W36748W36749W36750W36751W36752W3
14" (356MM)675467556756675767586759676067616762
W3 indicates power open/power closed6754W36755W36756W36757W36758W36759W36760W36761W36762W3
16" (406MM)67636764676567666767676867696770
W3 indicates power open/power closed6763W36764W36765W36766W36767W36768W36769W36770W3
18" (457MM)6771677267736774677567766777
20" (508MM)677867796780678167826783
22" (559MM)67846785678667876788
24" (610MM)6789679067916792
26" (660MM)679367946795
28" (711MM)67966797
30" (762MM)6798
Bottom Mount (Motor on long dimension)
8" (203MM)672168126813681468156816681768186819
W3 indicates power open/power closed6721W36812W36813W36814W36815W36816W36817W36818W36819W3
10" (254MM)67326823682468256826682768286829
W3 indicates power open/power closed6732W36823W36824W36825W36826W36827W36828W36829W3
12" (305MM)6743683468356836683768386839
W3 indicates power open/power closed6743W36834W36835W36836W36837W36838W36839W3
14" (356MM)6754675567566757675867596760
W3 indicates power open/power closed6754W36755W36756W36757W36758W36759W36760W3
16" (406MM)6763676467656766676767686769
W3 indicates power open/power closed6763W36764W36765W36766W36767W36768W36769W3
18" (457MM)6771677267736774677567766777
20" (508MM)677867796780678167826783
22" (559MM)67846785678667876788
24" (610MM)6789679067916792
26" (660MM)679367946795
28" (711MM)67966797
30" (762MM)6798

*Rectangular Damper Dimension = Nominal width + 3.5"
10 day lead time for shaded items

ROUND DAMPER SIZE & STOCK NO.*
NOMINAL DIAMETER (IN INCHES)4" (102MM)5" (127MM)6" (152MM)7" (178MM)8" (203MM)9" (229MM)10" (254MM)12" (305MM)14" (356MM)16" (406MM)18" (457MM)20" (508MM)
Zone Damper (Normally open/power closed)6606660766086609661066126614
W3 indicates power open/power closed6606W36607W36608W36609W36610W36612W36614W3
Ventilation Damper (Normally closed/power opened)6506650865106512
Barometric Pressure Relief (Air flow activated)61086110611261146116
Static Pressure Relief (Power activated)6208621062126214621662186220
Round Slip-In Damper (Normally open/ power closed)670467056706670767086710
Dimensions (W x H x D)3 4/5" x 12 3/5" x 7 3/10"3 4/5" x 12 3/5" x 8 3/10"3 4/5" x 12 3/5" x 9 3/10"3 4/5" x 12 3/5" x 10 3/10"3 4/5" x 12 3/5" x 11 3/10"3 4/5" x 12 3/5" x 13 3/10"

*Round Damper Dimension = Nominal diameter + 4.5"
10 day lead time for shaded items

Fresh Air Ventilation

Ventilators and Ventilating Dehumidifiers

Ventilators and Ventilating Dehumidifiers are part of the AprilAire Healthy Air System.

VENTILATION SYSTEMSUNIT SIZE (W x H x L)SHIPPING WEIGHT LBS.AIRFLOW @ 0.2 IN. W.C. (CFM)DESCRIPTION
VENTILATING DEHUMIDIFIERS
#E100V + 8190FF14 ½" x 23 ½" x 48 ¼"82.00 (E100V)
16.80 (8190FF)
100 ppd*The Ventilating Dehumidifier (Models E100V + 8190FF) brings in fresh air to meet ventilation needs while removing excess humidity from the incoming outdoor air. Fresh air is brought in whenever the HVAC system or dehumidifier is running. If the required time is not met, the unit will bring in fresh air and remove excess humidity.
#8192A15" x 14" x 26"82.00150The 8192A features an integrated ventilation control. It draws fresh air into the home by energizing its fan and opening its vent damper. If the incoming air is above a set relative humidity percentage point, the outside air is dehumidified by the 8192A.
*Dehumidification Capacity 100 Pints Per Day
FRESH AIR VENTILATORS
#8145A12 ¼" x 11 ¾" x 23 2/5"15.00210The 8145A or 8142A delivers fresh air into the return or supply duct by energizing its fan and opening its integrated damper. Both models feature an 8120A ventilation controller integrated into the unit.
#8145NC13 1/5" x 6 7/10" x 11 9/10"14.50210NC models do not include an on-board controller so that ventilation can be controlled via thermostat.
#8145K21.00The 8145K comes with 8145NC, 8120A control, inlet hood and start collar for adding ventilation to existing homes and systems.
#8142A11.50
#8142NC10.75
#8144NC10 ¼" x 18 1/8" x 10 ¼"20.50130The 8144NC provides continuous low-volume ventilation for smaller single- and multi-family homes. A separate 8120A ventilation controller can be added to set the unit to operate by the controller's Code or Comfort functions.
VENTILATION CONTROLLER
#8120A4 11/100" W x 3 3/5" H x 1 59/100" D0.50The 8120A engages a fan or damper on ventilation solutions to deliver fresh air to return duct. It can provide fresh air within set high/low outdoor temperature and indoor RH limits.
VENTILATION SYSTEM
#8126A10 8/25" W x 10 3/4" H x 6" D6.50185The 8126A includes a powered damper, ventilation controller, and installation accessories. The controller energizes the damper, mounted on the return side of the HVAC blower. When the HVAC blower energizes, negative pressure draws fresh air into the home.
#KV088" W x 10 3/4" H x 12 1/3" D6.00390KITCHEN VENTILATION KITS: The KV08, KV10 Kitchen Ventilation Kits provide make-up air locally to areas where high-CFM range hoods (typically near 400 CFM or above) are used to prevent home depressurization and its undesired side effects.
#KV1010" W x 10 3/4" H x 14 1/3" D6.70390
#810037 3/8" W x 20 23/40" H x 12 3/4" D87.00130FRESH AIR EXCHANGER (ERV): The 8100 draws in fresh outdoor air and exhausts stale indoor air, transferring energy (heating or cooling) between the two air sources, as well as transferring moisture. A ventilation controller or thermostat energizes blowers within the ventilator.

Accessories

ACCESSORIESPRODUCT DESCRIPTIONUNIT SIZETYPE OF WIRECOMPATIBLE MODELS
#8051Flush Mount Sensor: Ideal for residential or light commercial applications where customer requires nothing to be seen on the wall.Disk: 1 1/2" dia. Friction fit in a 1" opening. Air gap of 1/4" required.All thermostats, 8800, 8840
#8052Outdoor/Duct Sensor: Designed for outdoor or duct installation including with use of zone control panels.Probe: 1/4" dia. x 1 3/4" L
Bracket: 3/4" x 3/4"
18-24 gauge 2 conductor wire (or more conductors)All thermostats, 8800, 8840
#8053Surface Mount Sensor: Perfect for light indoor commercial applications to prevent tampering.W: 3 1/2" H: 2 1/2" D: 7/8"All thermostats, 8800, 8840
#80223-Wire to 4-Wire Adapter: Used to add a wire to a thermostat, fix a broken wire or add a common wire to a 4-wire system.W: 2 7/8" H: 1 3/4" D: 1 47/50"All thermostats
#8028Damper Power Distribution Panel: For applications where needed dampers outnumber control capability of any AprilAire Zone Control Panel.W: 10 1/2" H: 5" D: 1 7/10"18-22 gauge stranded or solid thermostat wire can be used for all wire runsAll zone control panels
#6401Expansion Panel: Two-zone expansion panel that supports 2-wire or 3-wire dampers.W: 10 1/2" H: 5" D: 1 7/10"6404 With LCD screen
AUTOMATION MODULES
#8082Temperature and RH Support Module: Averages four temperatures (on-board or offboard) and four humidity values (on-board only).W: 3 1/2" H: 2 1/2" D: 7/8"Cat 6 or greater8800 8840
#8083Flush Temperature and RH Support Module: Averages four temperature and four RH values.Disk: 1 1/2" dia. Cylinder Hole: 1" off wall, 1/4" air gapCat 6 or greater8800 8840

Ventilation Climate Zones

Managing the quality of ventilated air delivered into the home is critical to providing a healthy indoor environment. The requirements change significantly based on climate. AprilAire ventilation solutions work with the HVAC equipment to remove moisture, harmful particulates and other contaminants such as VOCs. It's critical to use intelligent ventilation controls and application guidance to properly ventilate rather than relying on exhaust ventilation which simply pulls air through walls.

Source: 2012 & 2015 International Residential Code § N1101.10 (R301.1). Zones are by county, based on factors including mean temperature, warmest month, precipitation and wet bulb temperature.

Use this map and the adjoining application guide to determine the recommended product solution for your climate. These recommendations are based on moisture removal demands, energy savings and integration with the HVAC equipment.

Ventilation Supply Solutions - AprilAire Ventilation Application Matrix

ZONECLIMATE TYPEMAJOR CITIESPRIMARY SOLUTION¹FRESH AIR DUCTED²ECONOMY- OR COMFORT-FOCUSED SOLUTIONMULTI-FAMILY NEW CONSTRUCTION SOLUTION
1Hot & MoistMiamiE100V + 8190FF or 8192A (Dehumidifies incoming ventilation air)HVAC Return8145A or 8126A8144NC
2Hot & MoistOrlando, Mobile, New Orleans, Houston, Austin, San AntonioE100V + 8190FF or 8192A (Dehumidifies incoming ventilation air)HVAC Return8145A or 8126A8144NC
2Hot & DryPhoenix, Tucson8142A (Mixes ventilation air after cooling or heating)HVAC Supply8142A
3Warm & MoistCharlotte, Charleston, Atlanta, Little Rock, Oklahoma City, DFWE100V + 8190FF or 8192A (Dehumidifies incoming ventilation air)HVAC Return8145A or 8126A8144NC
3Warm & DryEl Paso, Las Vegas, Los Angeles, Sacramento8142A (Mixes ventilation air after cooling or heating)HVAC Supply8142A8144NC
3Warm & MarineSan Francisco, San Jose8142A (Mixes ventilation air after cooling or heating)HVAC Supply8145A or 8126A8144NC
4Mixed & MoistPhiladelphia, Washington DC, Baltimore, Nashville, St. Louis, Wichita, Louisville8145A (Mixes ventilation air prior to cooling or heating)HVAC ReturnE100V + 8190FF, 8192A or 8126A8144NC
4Mixed & DryAlbuquerque, Amarillo8142A (Mixes ventilation air after cooling or heating)HVAC Supply8145A or 8126A8144NC
4Mixed & MarinePortland, Seattle8142A (Mixes ventilation air after cooling or heating)HVAC Supply8142A or 8126A8144NC
5Cool & MoistBoston, Pittsburgh, Columbus, Indianapolis, Detroit, Chicago, Des Moines, Omaha8145A (Mixes ventilation air prior to cooling or heating)HVAC Return8145A or 8126A8144NC
5Cool & DryDenver, Salt Lake City, Boise, Reno8145A (Mixes ventilation air prior to cooling or heating)HVAC Supply or Return8126A8144NC
6Cold & MoistToronto, Vancouver, Milwaukee, Madison, Minneapolis-St Paul, Sioux Falls8145A (Mixes ventilation air prior to cooling or heating)HVAC Return8126A8144NC
6Cold & DryHelena, Cheyenne8145A (Mixes ventilation air prior to cooling or heating)HVAC Return8126A8144NC
7Extreme Cold & MoistFargo, Duluth, Calgary, Edmonton8145A (Mixes ventilation air prior to cooling or heating)HVAC Return8126A8144NC

¹ Primary AprilAire recommended supply ventilation solution for optimal performance and building code adherence.
² HVAC application considerations based upon moist versus dry air, and proper mixing into the ductwork.

Control & Sanitize

The AprilAire Healthy Air System aims to provide greater health, virus protection, fewer allergens, more productivity, and better sleep by filling homes with Healthy Air.

Download the APP

The AprilAire Healthy Air App works with AprilAire connected devices, providing control from anywhere. It is compatible with AprilAire Wi-Fi thermostats.

Note: AprilAire makes no representations or warranties with respect to specific applications. AprilAire reserves the right to change specifications without notice.

Models: ARN15F Healthy Air Solutions, ARN15F, Healthy Air Solutions, Air Solutions, Solutions

File Info : application/pdf, 11 Pages, 7.89MB

PDF preview unavailable. Download the PDF instead.

aprilaire-all-products-specification-reference-guide-2210

References

Adobe PDF Library 17.0 Adobe InDesign 18.2 (Macintosh)

Related Documents

Preview AprilAire Humidifier Parts Lists and Diagrams
Comprehensive parts lists and diagrams for various AprilAire humidifier models, including 700, 800, 300, 400, 500, 600, 720, 350, 360, 1150, 1160, and 1180 series. This document provides part numbers and ordering information for replacement parts.
Preview Aprilaire Humidifier Control Installation and Safety Guide
Comprehensive safety and installation instructions for the Aprilaire Humidifier Control, covering wiring, setup, and troubleshooting for optimal home humidity management.
Preview Aprilaire Fresh Air Ventilation: Product & Application Guide
A comprehensive guide to Aprilaire's range of fresh air ventilation products, including whole-home ventilators, controllers, and energy recovery ventilators (ERVs), designed for enhanced indoor air quality, comfort, and energy efficiency in residential and light commercial applications.
Preview AprilAire Air Cleaner Installation and Owner's Manual: Models 1110-2416
This AprilAire Installation & Owner's Manual provides comprehensive guidance for AprilAire Whole-House Air Cleaners, covering models 1110, 1210, 1310, 1410, 1910, 2210, 2216, 2310, 2410, and 2416. It details safety instructions, specifications, dimensions, installation procedures, operation, maintenance, filter replacement, and warranty information to ensure optimal performance and healthy air in your home.
Preview AprilAire Model 8120X Digital Ventilation Controller Installation and Operating Instructions
Comprehensive guide for installing, operating, and troubleshooting the AprilAire Model 8120X Digital Ventilation Controller, covering wiring, setup, and system verification for optimal home ventilation.
Preview Aprilaire Series 800 Steam Humidifier Installation and Maintenance Instructions
Comprehensive guide for installing and maintaining the Aprilaire Series 800 Steam Humidifier. Covers safety precautions, materials list, operational principles, specifications, installation steps, and troubleshooting.
Preview AprilAire 720 Humidifier Wiring Instructions for Various Applications
Detailed wiring instructions for the AprilAire 720 Humidifier, covering standard wiring with Model 60, Model 4655 wired to HUM terminal, Model 4655 wired to EAC, Model 4655 with Current Sensing Relay, Model 4655 with Blower Activation Relay, and Model 4655 with Air Flow Proving Switch.
Preview AprilAire 720 Humidifier Wiring Instructions for Various Applications
Comprehensive wiring diagrams and instructions for AprilAire 720 series humidifiers, covering standard installations, Model 60 controls, Model 4655 with HUM terminal, EAC, current sensing relay, blower activation relay, and air flow proving switch.