AprilAire Healthy Air Solutions
AprilAire provides professional-grade Healthy Air solutions. The company's mission is to enhance people's health by improving the air in their homes, recognizing that Healthy Air is essential to a healthy lifestyle and overall well-being. Solutions are inspired by consumer needs and the expertise of professional contractors.
AprilAire is Healthy Air.
Features a 5-year warranty on all installed products.
Key Solution Areas: Radon Mitigation, Air Filtration, UVC, Fresh Air Ventilation, Humidification, Dehumidification, Zone Control.
Radon Mitigation Fans
AprilAire Radon Mitigation Fans are specifically designed for radon mitigation, offering superb performance and ultra-quiet operation.
Features
- Energy efficient
- Ultra-quiet operation
- Meets all electrical code requirements
- Housing that stays white
- Water-hardened motorized impeller
- Seams sealed to inhibit radon leakage (ARN15F/ARN25F double snap sealed)
- ETL Listed - for indoor or outdoor use
- Thermally protected motor
- Rated for commercial and residential use
- Patent pending design
- Optimal for moderate to tight soils (ARNHPF Only)
- Technology to inhibit radon and soil gas leakage
- ETL listed by Intertek to UL507 and CSA C22.2 Standards
Models and Specifications
Dimensions:
- ARN15F: 9.7" H x 8.5" W
- ARN25F: 11.75" H x 8.6" W
- ARNHPF: 11.9" H x 10.9" W
MODEL | FAN DIAMETER | RECOMMENDED DUCT | WATTS | TYPICAL CFM vs. STATIC PRESSURE " WC | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
0.2 | 0.5 | 1.0 | 1.5 | 2.0 | 2.5 | 3.0 | 3.5 | 4.0 | ||||
ARN15F | 4" | 41-72 | 1.7 | 166 | 126 | 82 | 41 | 3 | - | - | - | - |
ARN25F | 6" | 70-170 | 2.3 | 375 | 340 | 282 | 204 | 140 | 70 | - | - | - |
ARNHPF | 3" | 70-170 | 4.0 | - | 110 | 97 | 88 | 79 | 68 | 54 | 36 | 14 |
Mitigation Kits
MODEL | Slab size | Fan Type | Dimensions DxH | Color | Fan Duct Diameter | Pressure |
---|---|---|---|---|---|---|
ARN15K | <1500 sq. ft. | RF1, RF2 | 9.7 x 8.5 | White | 4" | 1.7 WC |
ARN25K | 1500-2500 sq. ft. | - | 11.75 x 8.6 | White | 6" | 2.3 WC |
ARNHPK | Moderate to Tight Soil | - | 11.9 x 10.9 | White | 3" | 4.0 WC |
Radon Accessories
ACCESSORY | DESCRIPTION |
---|---|
Manometer P/N ARN05M | Mounts to the outside of PVC pipe on a radon mitigation system and measures vacuum pressure in real time, helping to indicate potential issues with the fan. It can serve as a secondary indicator that vacuum pressure has changed in the event of a system alarm going off, helping to confirm that it's not a false alarm. |
Transition Fitting P/N ARNTF4 | Consolidates the number of fittings needed in outdoor radon mitigation system installations. Connects a 4" fan pipe to a 4" exhaust pipe with a weir (not included) for capturing and draining condensate. Weir is included in the Condensate Bypass Kit. |
Condensate Bypass Kit P/N ARNCBK | Designed to drain condensation around the fan in outdoor installs. |
Radon-T Fitting P/N ARNSIT | Designed for use in adding radon mitigation to new construction and crawl spaces. Provides 4-way airflow, allowing moisture and soil gases to be drawn from all angles. |
System Alarm P/N ARNALM | Advanced vacuum monitoring device utilizing piezoresistive pressure sensor (PPS) technology. It provides homeowners with an easy-to-read, easy-to-use system alarm that requires no interpretation. |
Humidity Control - Humidifiers
Humidifiers are part of the AprilAire Healthy Air System.
Types of Humidification
HUMIDIFIERS | TYPE OF HUMIDIFICATION | UNIT SIZE (W x H x D) | PLENUM OPENING | CAPACITY (GPD) | ELECTRICAL DATA |
---|---|---|---|---|---|
#800* | Steam | 10 1/8" x 20 7/8" x 7 1/8" | - | 11.5 GPD | 120 VAC 60HZ 11.5A |
#801*** | Fan Pack: 14" x 6 29/32" x 3 15/16" Finished Grille: 16 3/16" x 9" x 1 3/32" | - | 16.0 GPD | 120 VAC 60HZ 16.0A | |
#865** | 15 29/32" x 18" x 10 11/32" | - | 20.5 GPD | 208 VAC 60HZ 11.5A | |
#866*** | - | 30.0 GPD | 208 VAC 60HZ 16.0A | ||
#700* | Fan Powered Evaporative | 23.3 GPD | 240 VAC 60HZ 11.5A | ||
#700M** | 34.6 GPD | 240 VAC 60HZ 16.0A | |||
#600* | Large Bypass Evaporative | W: 14 3/4" H: 14 31/100" | 18 GPD | 120 VAC 60HZ 0.8A | |
#600M** | |||||
#500* | Small Bypass Evaporative | W: 10" H: 12 3/4" | 6" dia. round opening | 17 GPD | 24 VAC 60HZ 0.5A |
#500M** | W: 9 1/2" H: 9 1/2" | 6" dia. round opening | 12 GPD | 24 VAC 60HZ 0.5A | |
#400* | Water Saver Bypass Evaporative | W: 10" H: 12 3/4" | 6" dia. round opening | 17 GPD | 24 VAC 60HZ 0.5A |
#400M** | See note on heat pumps | 13 GPD | 120 VAC 60HZ 0.7A | ||
#300 | Self-Contained Evaporative | 14 3/8" x 12 1/2" x 22 3/32" |
*Automatic Digital Control (shown)
**Manual Control - For those rare occurrences where an automatic control is not practical, AprilAire offers the same great humidifiers with a manual control.
***801 & 866 Modulating Steam Humidifier - For precise RH control. Controls are sold separately.
Heat Pumps: Model 400 can be installed in heat pump applications. Due to lower temperature air from heat pumps, evaporation is approximately 60% of rated capacity. Consult your dealer for sizing considerations.
Model 800LC: Available with 80LC canister for less conductive water (75-300 µS/cm) and 120VAC applications.
GPD: Gallons Per Day, as recommended by AHRI. Evaporative capacities assume blower is active 100% of the time, plenum temperature is at 120°F and water is cold.
Water Usage Rate: Model 300 is 6 gph; Models 500, 600 and 700 are 3 gph; Model 400 is 0.7 gph; Model 800 is 0.6 to 1.8 gph depending on voltage, amp draw and water quality.
Humidifier Sizing Guidelines
GPD Needed Per Square Foot Based on Building Structure Tightness
VOLUME OF BUILDING (FT³) | BUILDING FLOOR AREA (FT²) WITH 8 FT CEILINGS | GPD NEEDED | ||
---|---|---|---|---|
Tight | Average | Loose | ||
8000 | 1000 | 3.3 | 6.7 | 10.0 |
12000 | 1500 | 5.0 | 10.0 | 15.0 |
16000 | 2000 | 6.7 | 13.4 | 20.0 |
20000 | 2500 | 8.3 | 16.7 | 25.0 |
24000 | 3000 | 10.0 | 20.0 | 30.1 |
32000 | 4000 | 13.4 | 26.7 | 40.1 |
40000 | 5000 | 16.7 | 33.4 | 50.1 |
Regional Humidifier Applications
AprilAire humidifiers can be installed on many different types of HVAC equipment. This application guide assists in selecting the appropriate AprilAire product based upon geography and heating equipment. It is important to consider plenum temperature, air flow (fan speed) and run time (heat call primary, fan only call secondary) when selecting products.
Automatic humidity controls have an integrated blower activation feature. Installations with a manual humidifier control can increase capacity by turning the thermostat fan to "ON". When installing evaporative humidifiers, it is recommended they are plumbed to hot water.
CLIMATE ZONE/RECOMMENDED APRILAIRE HUMIDIFIER SOLUTION BY MODEL | MIDWEST/ NORTHEAST | MID-ATLANTIC/ MID-SOUTHERN | MOUNTAIN | SOUTH | DESERT (SOUTHWEST) |
---|---|---|---|---|---|
Gas/Oil Furnace-Single Stage or Multi Stage* | 400/500/600/700/800 | 400/500/600/700/800 | 400/500/600/700/800 | 500/600/700/800 | 800 |
Gas/Oil Modulating Furnace** | 700/800 | 700/800 | 700/800 | 700/800 | 800 |
Heat Pump/Geo-Single Stage or Multi Stage* | 400/500/600/700/800 | 400/500/600/700/800 | 400/500/600/700/800 | 500/600/700/800 | 800 |
Heat Pump/Geo-Modulating** | 700/800 | 700/800 | 700/800 | 700/800 | 800 |
Boiler With AHU (No Heat Source) | 800 | 800 | 800 | 800 | 800 |
Boiler With AHU and Hot Water Coil/ Hydro Air Unit | 700/800 | 700/800 | 800 | 800 | 800 |
Boiler | 300/865 | 300/865 | 300/865 | 300/865 | 300/865 |
Electric Baseboard Heating | 300/865 | 300/865 | 300/865 | 300/865 | 300/865 |
Humidifying with A/C Unit | 800 | 800 | 800 | 800 | 800 |
*PSC, constant torque ECM
**Variable speed ECM
Evaporative performance of bypass humidifiers decreases with lower airflow volume and lower air temperature. Bypass models can be used in these applications if the HVAC system pressure differential between supply and return ducts is at least 0.08 in. wg and air temperature, hot water and continuous fan in the supply duct is at least 100°F.
Humidity Control - Dehumidifiers
Dehumidifiers are part of the AprilAire Healthy Air System.
MODEL | UNIT SIZE (W x H x L) | CAPACITY (PPD) | AIRFLOW @ VARYING E.S.P. (EXTERNAL STATIC PRESSURE - DRY COIL) | UNIT WEIGHT (LBS.) | |||
---|---|---|---|---|---|---|---|
@80°F/60%RH | @73°F/60%RH | 0.0" w.c. | 0.2" w.c. | 0.4" w.c. | |||
#E070 | 12½" x 12½" x 25" | 70 ppd | 53 ppd | 200 CFM | 170 CFM | 140 CFM | 56 |
#E080 | 14" x 15" x 26" | 80 ppd | 65 ppd | 185 CFM | 135 CFM | 85 CFM | 63 |
#E080H1 | |||||||
#E100 | 14" x 15" x 26" | 100 ppd | 85 ppd | 280 CFM | 245 CFM | 210 CFM | 64 |
#E100C2 | |||||||
#E130 | 19½" x 18½" x 30" | 130 ppd | 105 ppd | 310 CFM | 270 CFM | 225 CFM | 98 |
#E130H1 | |||||||
#E130C2 |
Note: E080H1, E100H and E130H are hardwired units. E100C2 and E130C are on casters.
Dehumidifier Sizing Guidelines
The recommended home floor area (ft²) that each listed dehumidifier can dehumidify is for sizing guidelines only. Actual home size depends on location, ventilation rate, occupant habits, AC system moisture removal, and comfort conditions.
REGION | MODEL | RECOMMENDED HOME FLOOR AREA (FT²) | |
---|---|---|---|
LOOSE | TIGHT | ||
REGION A (Most Humid) | MODEL E080 | 3,200 Ft² | 4,400 Ft² |
MODEL E100 | 4,000 Ft² | 5,500 Ft² | |
MODEL E130 | 5,200 Ft² | 7,200 Ft² | |
REGION B (Moderately Humid) | MODEL E080 | 2,600 Ft² | 3,900 Ft² |
MODEL E100 | 3,200 Ft² | 5,000 Ft² | |
MODEL E130 | 3,900 Ft² | 6,500 Ft² | |
REGION C (Less Humid) | MODEL E080 | 1,600 Ft² | 2,300 Ft² |
MODEL E100 | 2,000 Ft² | 3,000 Ft² | |
MODEL E130 | 2,300 Ft² | 3,600 Ft² |
Provide on-demand sizing recommendations using the Dehumidifier Selection Assistant at AprilAirepartners.com/dsa.
Air Filtration - Air Cleaners
Air Cleaners are part of the AprilAire Healthy Air System.
AIR CLEANERS | NOMINAL SIZE (IN INCHES) | CABINET SIZE (W x H x D) | SHIPPING WEIGHT (LBS) | INCLUDED FILTER | COMPATIBLE FILTERS* |
---|---|---|---|---|---|
#2216 | 20 x 25 | 6 3/4" x 22 1/16" x 27 3/8" | 20 | MERV 16 (216) | 216, 213CBN, 210 |
#2416 | 16 x 25 | 6 3/4" x 17 3/4" x 30 1/16" | 19.25 | MERV 16 (416) | 416, 413CBN, 410 |
#2516 | 31 x 28 | 6 3/4" x 31" x 30 1/16" | 24.9 | MERV 16 (516) | 516, 513CBN, 510 |
#2210 | 20 x 25 | 6 3/4" x 22 1/16" x 27 3/8" | 19 | MERV 10 (210) | 210, 213CBN, 213 |
#2310 | 20 x 20 | 6 3/4" x 20 3/8" x 22 1/16" | 17 | MERV 10 (310) | 310, 313 |
#2410 | 16 x 25 | 6 3/4" x 17 3/4" x 30 1/16" | 19 | MERV 10 (410) | 410, 413CBN, 413 |
#1110 | 16 x 20 | 6 3/4" x 17 3/4" x 22 1/16" | 13 | MERV 10 (110) | 110, 113 |
#1210 | 20 x 25 | 6 3/4" x 22 1/16" x 27 3/8" | 20 | MERV 10 (210) | 210, 213CBN, 213 |
#1310 | 20 x 20 | 6 3/4" x 20 3/8" x 22 1/16" | 15 | MERV 10 (310) | 310, 313 |
#1410 | 16 x 25 | 6 3/4" x 17 3/4" x 30 1/16" | 19 | MERV 10 (410) | 410, 413CBN, 413 |
#1510 | 31 x 28 | 6 3/4" x 31" x 30 1/16" | 28 | MERV 10 (510) | 510, 513CBN, 513 |
#1910 | 25 x 20 | 6 3/4" x 25 1/16" x 22 1/16" | 18 | MERV 10 (910) | 910, 913 |
#1610 | 16 x 25 | 15 11/16" x 17 13/16" x 30 3/16" | 31 | MERV 10 (610) | 610, 613 |
#1620 | 20 x 25 | 15 11/16" x 22 1/8" x 27 3/8" | 32.4 | MERV 10 (810) | 810, 813 |
#5000 | 16 x 25 | 12" W x 18 3/8" H (front) x 17 3/4" H (back) x 31" D | 35 | ELECTRONIC AIR CLEANER (501) | 501 |
*Included filter is always available as a replacement.
Air Sanitization - UVC
MODEL # | CONTAINS | AIR CLEANER SIZE INCLUDED (H x L x W) | FILTER |
---|---|---|---|
AUV24V | UVC Coil Cleaner | 20" x 25" x 4" | 210 MERV 11 |
AUVRPB | Replacement UVC Lamp | 16" x 25" x 4" | 410 MERV 11 |
UV12 | 1210 Air Cleaner AUV24V UV-C Coil Cleaner | 20" x 25" x 4" | 213 MERV 13 |
UV14 | 1410 Air Cleaner AUV24V UV-C Coil Cleaner | 16" x 25" x 4" | 413 MERV 13 |
UV22 | 2210 Air Cleaner AUV24V UV-C Coil Cleaner | 20" x 25" x 4" | 213 MERV 13 |
UV24 | 2410 Air Cleaner AUV24V UV-C Coil Cleaner | 16" x 25" x 4" | 413 MERV 13 |
Air Filtration - Air Filters
Air Filters are part of the AprilAire Healthy Air System.
Static Pressures at Variable CFM (in. w.c.)
FILTER NO. | 200 | 400 | 600 | 800 | 1000 | 1200 | 1400 | 1600 | 1800 | 2000 | 2200 | 2400 | 2600 | 2800 | 3000 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
216 | 0.06 | 0.09 | 0.13 | 0.17 | 0.23 | 0.29 | 0.36 | ||||||||
416 | 0.07 | 0.10 | 0.13 | 0.18 | 0.24 | 0.31 | |||||||||
516 | 0.04 | 0.05 | 0.07 | 0.09 | 0.10 | 0.13 | 0.15 | 0.18 | 0.21 | 0.24 | 0.27 | 0.31 | |||
113 | 0.03 | 0.07 | 0.11 | 0.16 | 0.22 | 0.29 | |||||||||
213 | 0.02 | 0.04 | 0.06 | 0.09 | 0.12 | 0.15 | 0.19 | 0.23 | 0.27 | 0.31 | |||||
313 | 0.03 | 0.05 | 0.09 | 0.13 | 0.17 | 0.23 | |||||||||
413 | 0.02 | 0.05 | 0.07 | 0.10 | 0.14 | 0.17 | 0.22 | 0.26 | 0.31 | 0.37 | |||||
513 | 0.01 | 0.02 | 0.04 | 0.05 | 0.05 | 0.07 | 0.08 | 0.10 | 0.11 | 0.13 | 0.15 | 0.17 | 0.18 | 0.20 | 0.23 |
613 | 0.02 | 0.05 | 0.07 | 0.10 | 0.14 | 0.17 | 0.22 | 0.26 | 0.31 | 0.37 | |||||
813 | 0.02 | 0.04 | 0.06 | 0.09 | 0.12 | 0.15 | 0.19 | 0.23 | 0.27 | 0.31 | |||||
913 | - | 0.03 | 0.05 | 0.07 | 0.09 | 0.12 | 0.15 | 0.18 | 0.22 | 0.27 | |||||
213CBN | 0.04 | 0.07 | 0.10 | 0.13 | 0.17 | 0.21 | 0.25 | 0.30 | 0.35 | ||||||
413CBN | 0.04 | 0.07 | 0.10 | 0.14 | 0.19 | 0.24 | 0.29 | 0.36 | 0.43 | ||||||
513CBN | 0.03 | 0.04 | 0.05 | 0.07 | 0.08 | 0.10 | 0.12 | 0.15 | 0.17 | 0.20 | 0.22 | 0.25 | 0.29 | 0.32 | |
110 | 0.02 | 0.05 | 0.06 | 0.10 | 0.14 | 0.20 | |||||||||
210 | 0.02 | 0.03 | 0.04 | 0.06 | 0.08 | 0.11 | 0.13 | 0.16 | 0.19 | 0.22 | |||||
310 | 0.02 | 0.04 | 0.06 | 0.10 | 0.14 | 0.19 | |||||||||
410 | 0.02 | 0.03 | 0.05 | 0.07 | 0.09 | 0.12 | 0.15 | 0.19 | 0.22 | 0.27 | |||||
510 | 0.02 | 0.02 | 0.03 | 0.04 | 0.04 | 0.05 | 0.06 | 0.07 | 0.09 | 0.10 | 0.12 | 0.14 | 0.15 | 0.17 | 0.19 |
610 | 0.02 | 0.03 | 0.05 | 0.07 | 0.09 | 0.12 | 0.15 | 0.19 | 0.22 | 0.27 | |||||
810 | 0.02 | 0.03 | 0.04 | 0.06 | 0.08 | 0.11 | 0.13 | 0.16 | 0.19 | 0.22 | |||||
910 | - | 0.03 | 0.05 | 0.07 | 0.09 | 0.12 | 0.15 | 0.18 | 0.22 | 0.27 | |||||
201 | 0.02 | 0.04 | 0.05 | 0.08 | 0.10 | 0.12 | 0.15 | 0.18 | 0.21 | 0.25 | |||||
401 | 0.02 | 0.04 | 0.05 | 0.08 | 0.10 | 0.14 | 0.17 | 0.21 | 0.25 | 0.29 | |||||
501 | 0.02 | 0.04 | 0.05 | 0.08 | 0.10 | 0.14 | 0.17 | 0.21 | 0.25 | 0.29 |
*Highest value shown is maximum recommended airflow capacity.
Removal Efficiency (Based on Particle Size)
MERV RATING | 0.3 µm - 1.0 µm | 1.0 µm - 3.0 µm | 3.0 µm - 10.0 µm |
---|---|---|---|
MERV 16 | 95% | 98% | 99% |
MERV 13 | 63% | 88% | 93% |
MERV 11 | 37% | 67% | 92% |
MERV 10 | 22% | 56% | 92% |
EAC - 5000 | 89% | 95% | 98% |
Test Method: MERV 10-16 ASHRAE 52.2.2012, EAC AHRI 680-2009
Upgrade Kits
NOMINAL SIZE (IN INCHES) | COMPATIBLE WITH | INCLUDED FILTER | RAILS MODEL NUMBER | STATIC PRESSURE DROP (in. w.c.) @ 1200 CFM | MAXIMUM AIRFLOW CAPACITY (CFM) | |
---|---|---|---|---|---|---|
#1213 | 20 x 25 | AprilAire or Space-Gard 2200 | 213 MERV 13 | 4893 | 0.15 | 2000 |
#1413 | 16 x 25 | AprilAire or Space-Gard 2400 | 413 MERV 13 | 4894 | 0.17 | 2000 |
Upgrade Rails
Nominal Size (in inches) | Compatible With | Uses Filter Model | Maximum Airflow Capacity (in CFM) |
---|---|---|---|
20x25 | AprilAire or Space-Gard 2200 | 210, 213, 213CBN | 2000 |
16x25 | AprilAire or Space-Gard 2400 | 410, 413, 413CBN | 2000 |
16x25 | 16x25 Competitive Cabinets | 610, 613 | 2000 |
20x25 | 20x25 Competitive Cabinets | 810, 813 | 2000 |
16x20 | 16x20 Competitive Cabinets | 110, 113 | 1200 |
20x20 | 20x20 Competitive Cabinets | 310, 313 | 1200 |
Replacement Filters
FILTER NO. | USED WITH APRILAIRE AIR CLEANER MODELS | NOMINAL SIZE (IN INCHES) | STATIC PRESSURE DROP (in. w.c.) @ 1200 CFM | MAXIMUM AIRFLOW CAPACITY (CFM) |
---|---|---|---|---|
201 | AprilAire or Space-Gard 2200** | 20 x 25 | 0.12 | 2000 |
401 | AprilAire or Space-Gard 2400** | 16 x 25 | 0.14 | 2000 |
**Air Cleaner models no longer available.
Healthy Air Controls - Thermostats
Thermostats are part of the AprilAire Healthy Air System.
RESIDENTIAL MODEL NUMBER | STAGES | HOME AUTOMATION MODEL NO. | Dimensions (W x H x D) | FEATURES |
---|---|---|---|---|
S84N1H1C | 1H/1C | Programmable and Non-Programmable, Easy to Read Display, Temperature Control, Air Cleaning, Simple Setup, Displays Outdoor Temperature (if equipped), Adjustable Differential, Progressive Recovery, Heat Blast, Event-Based™ Air Cleaning, Air Cleaning Notice, Change Filter Alert, Automatic or Manual Humidifier Control, "Humidifier On" Notice | ||
S84NSU | 1H/1C, 2H/1C | Programmable and Non-Programmable, Easy to Read Display, Temperature Control, Air Cleaning, Simple Setup, Displays Outdoor Temperature (if equipped), Adjustable Differential, Progressive Recovery, Heat Blast, Event-Based™ Air Cleaning, Air Cleaning Notice, Change Filter Alert, Automatic or Manual Humidifier Control, "Humidifier On" Notice | ||
S86NMU | 2H/2C, 4H/2C HP | Programmable and Non-Programmable, Easy to Read Display, Temperature Control, Air Cleaning, Simple Setup, Displays Outdoor Temperature (if equipped), Adjustable Differential, Progressive Recovery, Heat Blast, Event-Based™ Air Cleaning, Air Cleaning Notice, Change Filter Alert, Automatic or Manual Humidifier Control, "Humidifier On" Notice | ||
S86NMUPR | 2H/2C, 4H/2C HP | Programmable and Non-Programmable, Easy to Read Display, Temperature Control, Air Cleaning, Simple Setup, Displays Outdoor Temperature (if equipped), Adjustable Differential, Progressive Recovery, Heat Blast, Event-Based™ Air Cleaning, Air Cleaning Notice, Change Filter Alert, Automatic or Manual Humidifier Control, "Humidifier On" Notice | ||
S86WMUPR ** | 2H/2C, 4H/2C HP | 3.75" x 3.75" x 1.00" | Wi-Fi, Programmable and Non-Programmable, Easy to Read Display, Temperature Control, Air Cleaning, Simple Setup, Displays Outdoor Temperature (if equipped), Adjustable Differential, Progressive Recovery, Heat Blast, Event-Based™ Air Cleaning, Air Cleaning Notice, Change Filter Alert, Automatic or Manual Humidifier Control, "Humidifier On" Notice, Displays Indoor RH | |
8910 8910W** | 3H/3C, 4H/2C HP | 4.38" x 4.38" x 0.8" | Wi-Fi, Programmable and Non-Programmable, Easy to Read Display, Temperature Control, Air Cleaning, Simple Setup, Displays Outdoor Temperature (if equipped), Adjustable Differential, Progressive Recovery, Heat Blast, Event-Based™ Air Cleaning, Air Cleaning Notice, Change Filter Alert, Automatic or Manual Humidifier Control, "Humidifier On" Notice, Displays Indoor RH | |
8920W** | 3H/3C, 4H/2C HP | 6" x 4.85" x 1.25" | Wi-Fi, Programmable and Non-Programmable, Easy to Read Display, Temperature Control, Air Cleaning, Simple Setup, Displays Outdoor Temperature (if equipped), Adjustable Differential, Progressive Recovery, Heat Blast, Event-Based™ Air Cleaning, Air Cleaning Notice, Change Filter Alert, Automatic or Manual Humidifier Control, "Humidifier On" Notice, Displays Indoor RH | |
IAQ Control Equipment Control Module 8 3/5" x 9 3/5" x 1 9/10" | 7.1" x 4.85" x 1" | Humidifier Control, Energizes HVAC Blower for Humidity, Controls Humidifier with 24 VAC Dry Contact, Dehumidifier Control, Controls Whole-Home Dehumidifier, Controls A/C Equipment for Dehumidification, Senses and Displays Indoor RH, "Dehumidifier On" Notice, Energizes HVAC Blower for Dehumidification, Controls Dehumidifier with 24 VAC Dry Contact, Ventilation Control, Programmable for Timed Ventilation, Programmable for ASHRAE 62.2 Ventilation, Configurable Temperature and Humidity Limits, "Ventilation On" Notice, Controls Air Cleaner and Humid or Dehumid or Vent, Controls Air Cleaner and Humid, Dehumid and Vent, Wired Outdoor Product Configuration, Temperature Sensor Included, Two-Part Design—Only 3 Wires to the Living Space |
**Compatible with Wireless Indoor and Outdoor Temperature/RH sensors.
Sensors for Model S86WMUPR only.
Wireless Sensors
MODEL # | TYPE OF SENSOR | COMMUNICATIONS | WIRELESS RANGE | TEMPERATURE MEASUREMENT | HUMIDITY MEASUREMENT RANGE/ ACCURACY | BATTERY LIFE | BATTERY TYPE |
---|---|---|---|---|---|---|---|
#Z10IDT | Indoor Wireless Temperature and Humidity Sensor | 2.4 GHz | 35+ feet in typical application* | Accuracy: ±2°F (40°F to 105°F), ±5°F outside of this range | Range: 0.5% to 99.5% RH Accuracy: ±5% RH between 20% and 80% RH | 1 year | Lithium CR2032 type |
#Z10ODT | Outdoor Wireless Temperature and Humidity Sensor | 2.4 GHz | 35+ feet in typical application* | Range: -40°F to 125°F | Range: 0.5% to 99.5% RH Accuracy: ±5% RH between 20% and 80% RH | 2 years | Lithium CR2477 type |
*Actual distance varies dependent on number and type of interferences. Refer to signal strength for best results.
Features: Get precise temperature control, reducing hot/cold spots, by averaging an installed thermostat with wireless indoor sensors. Temperature/event scheduling for specific areas of the house possible with wireless sensor installation (indoor sensor only).
Zone Control Panels
MODEL | SPECIFICATIONS | UNIVERSAL ZONED COMFORT CONTROL™ KITS** AVAILABLE | HEAT PUMP ONLY | CONVENTIONAL ONLY |
---|---|---|---|---|
6404 | 4 Zone Universal Multistage (Can be expanded to 12 zones with Model 6401) 2 Heat 2 Cool or 4 Heat 2 Cool (Heat Pump) Compatible with Model 8056 wireless outdoor sensor Overall Dimensions: 8 63/100" W x 14 18/25" H x 1 43/50" D Humidity: 5%-90% RH, non-condensing Operating Temperature: 32°F–158°F Shipping Temperature: -40°F–180°F Voltage: 18-30VAC 50/60 Hz Maximum Current: Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; zone panel consumption: 4VA max Note: Use 18 or 20 AWG solid (non-stranded) wire | 6404K | ||
6403 | 3 Zone Universal Multistage 2 Heat 2 Cool or 4 Heat 2 Cool (Heat Pump) Compatible with Model 8056 wireless outdoor sensor Overall Dimensions: 8 63/100" W x 9 33/50" H x 1 43/50" D Humidity: 5%-90% RH, non-condensing Operating Temperature: 32°F–158°F Shipping Temperature: -40°F–180°F Voltage: 18-30VAC 50/60 Hz Maximum Current: Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; zone panel consumption: 4VA max Note: Use 18 or 20 AWG solid (non-stranded) wire | 6403K | ||
6303 | 3 Zone Heat Pump 2 Heat 1 Cool Single Stage Overall Dimensions: 8 63/100" W x 9 33/50" H x 1 43/50" D Humidity: 5% - 90% RH, non-condensing Operating Temperature: 32°F–158°F Shipping Temperature: -40°F–180°F Voltage: 18-30VAC 50/60 Hz Maximum Current: Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; zone panel consumption: 4VA max Note: Use 18 or 20 AWG solid (non-stranded) wire | 6303K | ||
6302 | 2 Zone Heat Pump 2 Heat 1 Cool Single Stage Overall Dimensions: 8 63/100" W x 9 33/50" H x 1 43/50" D Humidity: 5% - 90% RH, non-condensing Operating Temperature: 32°F–158°F Shipping Temperature: -40°F–180°F Voltage: 18-30VAC 50/60 Hz Maximum Current: Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; zone panel consumption: 4VA max Note: Use 18 or 20 AWG solid (non-stranded) wire | 6302K | ||
6203 | 3 Zone Heat/Cool 1 Heat 1 Cool Single Stage Overall Dimensions: 8 63/100" W x 9 33/50" H x 1 43/50" D Humidity: 5%–90% RH, non-condensing Operating Temperature: 32°F–158°F Shipping Temperature: -40°F–180°F Voltage: 18-30VAC 50/60 Hz Maximum Current: Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; zone panel consumption: 4VA max Note: Use 18 or 20 AWG solid (non-stranded) wire | 6203K | ||
6202 | 2 Zone Heat/Cool 1 Heat 1 Cool Single Stage Overall Dimensions: 8 63/100" W x 9 33/50" H x 1 43/50" D Humidity: 5%–90% RH, non-condensing Operating Temperature: 32°F–158°F Shipping Temperature: -40°F–180°F Voltage: 18-30VAC 50/60 Hz Maximum Current: Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; zone panel consumption: 4VA max Note: Use 18 or 20 AWG solid (non-stranded) wire | 6202K |
**Zoned Comfort Control Kits include: Zone panel, 6" duct probe and 24VAC 40VA universal transformer.
Healthy Air Controls - Zone Dampers
RECTANGULAR DAMPER SIZE & STOCK NO.* | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
NOMINAL WIDTH (IN INCHES) | 8" (203MM) | 10" (254MM) | 12" (305MM) | 14" (356MM) | 16" (406MM) | 18" (457MM) | 20" (508MM) | 22" (559MM) | 24" (610MM) | 26" (660MM) | 28" (711MM) | 30" (762MM) |
Side Mount (Motor on short dimension) | 6721 | 6722 | 6723 | 6724 | 6725 | 6726 | 6727 | 6728 | 6729 | 6730 | 6731 | 6753 |
W3 indicates power open/power closed | 6721W3 | 6722W3 | 6723W3 | 6724W3 | 6725W3 | 6726W3 | 6727W3 | 6728W3 | 6729W3 | 6730W3 | 6731W3 | 6753W3 |
10" (254MM) | 6732 | 6733 | 6734 | 6735 | 6736 | 6737 | 6738 | 6739 | 6740 | 6741 | 6742 | |
W3 indicates power open/power closed | 6732W3 | 6733W3 | 6734W3 | 6735W3 | 6736W3 | 6737W3 | 6738W3 | 6739W3 | 6740W3 | 6741W3 | 6742W3 | |
12" (305MM) | 6743 | 6744 | 6745 | 6746 | 6747 | 6748 | 6749 | 6750 | 6751 | 6752 | ||
W3 indicates power open/power closed | 6743W3 | 6744W3 | 6745W3 | 6746W3 | 6747W3 | 6748W3 | 6749W3 | 6750W3 | 6751W3 | 6752W3 | ||
14" (356MM) | 6754 | 6755 | 6756 | 6757 | 6758 | 6759 | 6760 | 6761 | 6762 | |||
W3 indicates power open/power closed | 6754W3 | 6755W3 | 6756W3 | 6757W3 | 6758W3 | 6759W3 | 6760W3 | 6761W3 | 6762W3 | |||
16" (406MM) | 6763 | 6764 | 6765 | 6766 | 6767 | 6768 | 6769 | 6770 | ||||
W3 indicates power open/power closed | 6763W3 | 6764W3 | 6765W3 | 6766W3 | 6767W3 | 6768W3 | 6769W3 | 6770W3 | ||||
18" (457MM) | 6771 | 6772 | 6773 | 6774 | 6775 | 6776 | 6777 | |||||
20" (508MM) | 6778 | 6779 | 6780 | 6781 | 6782 | 6783 | ||||||
22" (559MM) | 6784 | 6785 | 6786 | 6787 | 6788 | |||||||
24" (610MM) | 6789 | 6790 | 6791 | 6792 | ||||||||
26" (660MM) | 6793 | 6794 | 6795 | |||||||||
28" (711MM) | 6796 | 6797 | ||||||||||
30" (762MM) | 6798 | |||||||||||
Bottom Mount (Motor on long dimension) | ||||||||||||
8" (203MM) | 6721 | 6812 | 6813 | 6814 | 6815 | 6816 | 6817 | 6818 | 6819 | |||
W3 indicates power open/power closed | 6721W3 | 6812W3 | 6813W3 | 6814W3 | 6815W3 | 6816W3 | 6817W3 | 6818W3 | 6819W3 | |||
10" (254MM) | 6732 | 6823 | 6824 | 6825 | 6826 | 6827 | 6828 | 6829 | ||||
W3 indicates power open/power closed | 6732W3 | 6823W3 | 6824W3 | 6825W3 | 6826W3 | 6827W3 | 6828W3 | 6829W3 | ||||
12" (305MM) | 6743 | 6834 | 6835 | 6836 | 6837 | 6838 | 6839 | |||||
W3 indicates power open/power closed | 6743W3 | 6834W3 | 6835W3 | 6836W3 | 6837W3 | 6838W3 | 6839W3 | |||||
14" (356MM) | 6754 | 6755 | 6756 | 6757 | 6758 | 6759 | 6760 | |||||
W3 indicates power open/power closed | 6754W3 | 6755W3 | 6756W3 | 6757W3 | 6758W3 | 6759W3 | 6760W3 | |||||
16" (406MM) | 6763 | 6764 | 6765 | 6766 | 6767 | 6768 | 6769 | |||||
W3 indicates power open/power closed | 6763W3 | 6764W3 | 6765W3 | 6766W3 | 6767W3 | 6768W3 | 6769W3 | |||||
18" (457MM) | 6771 | 6772 | 6773 | 6774 | 6775 | 6776 | 6777 | |||||
20" (508MM) | 6778 | 6779 | 6780 | 6781 | 6782 | 6783 | ||||||
22" (559MM) | 6784 | 6785 | 6786 | 6787 | 6788 | |||||||
24" (610MM) | 6789 | 6790 | 6791 | 6792 | ||||||||
26" (660MM) | 6793 | 6794 | 6795 | |||||||||
28" (711MM) | 6796 | 6797 | ||||||||||
30" (762MM) | 6798 |
*Rectangular Damper Dimension = Nominal width + 3.5"
10 day lead time for shaded items
ROUND DAMPER SIZE & STOCK NO.* | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
NOMINAL DIAMETER (IN INCHES) | 4" (102MM) | 5" (127MM) | 6" (152MM) | 7" (178MM) | 8" (203MM) | 9" (229MM) | 10" (254MM) | 12" (305MM) | 14" (356MM) | 16" (406MM) | 18" (457MM) | 20" (508MM) |
Zone Damper (Normally open/power closed) | 6606 | 6607 | 6608 | 6609 | 6610 | 6612 | 6614 | |||||
W3 indicates power open/power closed | 6606W3 | 6607W3 | 6608W3 | 6609W3 | 6610W3 | 6612W3 | 6614W3 | |||||
Ventilation Damper (Normally closed/power opened) | 6506 | 6508 | 6510 | 6512 | ||||||||
Barometric Pressure Relief (Air flow activated) | 6108 | 6110 | 6112 | 6114 | 6116 | |||||||
Static Pressure Relief (Power activated) | 6208 | 6210 | 6212 | 6214 | 6216 | 6218 | 6220 | |||||
Round Slip-In Damper (Normally open/ power closed) | 6704 | 6705 | 6706 | 6707 | 6708 | 6710 | ||||||
Dimensions (W x H x D) | 3 4/5" x 12 3/5" x 7 3/10" | 3 4/5" x 12 3/5" x 8 3/10" | 3 4/5" x 12 3/5" x 9 3/10" | 3 4/5" x 12 3/5" x 10 3/10" | 3 4/5" x 12 3/5" x 11 3/10" | 3 4/5" x 12 3/5" x 13 3/10" |
*Round Damper Dimension = Nominal diameter + 4.5"
10 day lead time for shaded items
Fresh Air Ventilation
Ventilators and Ventilating Dehumidifiers
Ventilators and Ventilating Dehumidifiers are part of the AprilAire Healthy Air System.
VENTILATION SYSTEMS | UNIT SIZE (W x H x L) | SHIPPING WEIGHT LBS. | AIRFLOW @ 0.2 IN. W.C. (CFM) | DESCRIPTION |
---|---|---|---|---|
VENTILATING DEHUMIDIFIERS | ||||
#E100V + 8190FF | 14 ½" x 23 ½" x 48 ¼" | 82.00 (E100V) 16.80 (8190FF) | 100 ppd* | The Ventilating Dehumidifier (Models E100V + 8190FF) brings in fresh air to meet ventilation needs while removing excess humidity from the incoming outdoor air. Fresh air is brought in whenever the HVAC system or dehumidifier is running. If the required time is not met, the unit will bring in fresh air and remove excess humidity. |
#8192A | 15" x 14" x 26" | 82.00 | 150 | The 8192A features an integrated ventilation control. It draws fresh air into the home by energizing its fan and opening its vent damper. If the incoming air is above a set relative humidity percentage point, the outside air is dehumidified by the 8192A. |
*Dehumidification Capacity 100 Pints Per Day | ||||
FRESH AIR VENTILATORS | ||||
#8145A | 12 ¼" x 11 ¾" x 23 2/5" | 15.00 | 210 | The 8145A or 8142A delivers fresh air into the return or supply duct by energizing its fan and opening its integrated damper. Both models feature an 8120A ventilation controller integrated into the unit. |
#8145NC | 13 1/5" x 6 7/10" x 11 9/10" | 14.50 | 210 | NC models do not include an on-board controller so that ventilation can be controlled via thermostat. |
#8145K | 21.00 | The 8145K comes with 8145NC, 8120A control, inlet hood and start collar for adding ventilation to existing homes and systems. | ||
#8142A | 11.50 | |||
#8142NC | 10.75 | |||
#8144NC | 10 ¼" x 18 1/8" x 10 ¼" | 20.50 | 130 | The 8144NC provides continuous low-volume ventilation for smaller single- and multi-family homes. A separate 8120A ventilation controller can be added to set the unit to operate by the controller's Code or Comfort functions. |
VENTILATION CONTROLLER | ||||
#8120A | 4 11/100" W x 3 3/5" H x 1 59/100" D | 0.50 | The 8120A engages a fan or damper on ventilation solutions to deliver fresh air to return duct. It can provide fresh air within set high/low outdoor temperature and indoor RH limits. | |
VENTILATION SYSTEM | ||||
#8126A | 10 8/25" W x 10 3/4" H x 6" D | 6.50 | 185 | The 8126A includes a powered damper, ventilation controller, and installation accessories. The controller energizes the damper, mounted on the return side of the HVAC blower. When the HVAC blower energizes, negative pressure draws fresh air into the home. |
#KV08 | 8" W x 10 3/4" H x 12 1/3" D | 6.00 | 390 | KITCHEN VENTILATION KITS: The KV08, KV10 Kitchen Ventilation Kits provide make-up air locally to areas where high-CFM range hoods (typically near 400 CFM or above) are used to prevent home depressurization and its undesired side effects. |
#KV10 | 10" W x 10 3/4" H x 14 1/3" D | 6.70 | 390 | |
#8100 | 37 3/8" W x 20 23/40" H x 12 3/4" D | 87.00 | 130 | FRESH AIR EXCHANGER (ERV): The 8100 draws in fresh outdoor air and exhausts stale indoor air, transferring energy (heating or cooling) between the two air sources, as well as transferring moisture. A ventilation controller or thermostat energizes blowers within the ventilator. |
Accessories
ACCESSORIES | PRODUCT DESCRIPTION | UNIT SIZE | TYPE OF WIRE | COMPATIBLE MODELS |
---|---|---|---|---|
#8051 | Flush Mount Sensor: Ideal for residential or light commercial applications where customer requires nothing to be seen on the wall. | Disk: 1 1/2" dia. Friction fit in a 1" opening. Air gap of 1/4" required. | All thermostats, 8800, 8840 | |
#8052 | Outdoor/Duct Sensor: Designed for outdoor or duct installation including with use of zone control panels. | Probe: 1/4" dia. x 1 3/4" L Bracket: 3/4" x 3/4" | 18-24 gauge 2 conductor wire (or more conductors) | All thermostats, 8800, 8840 |
#8053 | Surface Mount Sensor: Perfect for light indoor commercial applications to prevent tampering. | W: 3 1/2" H: 2 1/2" D: 7/8" | All thermostats, 8800, 8840 | |
#8022 | 3-Wire to 4-Wire Adapter: Used to add a wire to a thermostat, fix a broken wire or add a common wire to a 4-wire system. | W: 2 7/8" H: 1 3/4" D: 1 47/50" | All thermostats | |
#8028 | Damper Power Distribution Panel: For applications where needed dampers outnumber control capability of any AprilAire Zone Control Panel. | W: 10 1/2" H: 5" D: 1 7/10" | 18-22 gauge stranded or solid thermostat wire can be used for all wire runs | All zone control panels |
#6401 | Expansion Panel: Two-zone expansion panel that supports 2-wire or 3-wire dampers. | W: 10 1/2" H: 5" D: 1 7/10" | 6404 With LCD screen | |
AUTOMATION MODULES | ||||
#8082 | Temperature and RH Support Module: Averages four temperatures (on-board or offboard) and four humidity values (on-board only). | W: 3 1/2" H: 2 1/2" D: 7/8" | Cat 6 or greater | 8800 8840 |
#8083 | Flush Temperature and RH Support Module: Averages four temperature and four RH values. | Disk: 1 1/2" dia. Cylinder Hole: 1" off wall, 1/4" air gap | Cat 6 or greater | 8800 8840 |
Ventilation Climate Zones
Managing the quality of ventilated air delivered into the home is critical to providing a healthy indoor environment. The requirements change significantly based on climate. AprilAire ventilation solutions work with the HVAC equipment to remove moisture, harmful particulates and other contaminants such as VOCs. It's critical to use intelligent ventilation controls and application guidance to properly ventilate rather than relying on exhaust ventilation which simply pulls air through walls.
Source: 2012 & 2015 International Residential Code § N1101.10 (R301.1). Zones are by county, based on factors including mean temperature, warmest month, precipitation and wet bulb temperature.
Use this map and the adjoining application guide to determine the recommended product solution for your climate. These recommendations are based on moisture removal demands, energy savings and integration with the HVAC equipment.
Ventilation Supply Solutions - AprilAire Ventilation Application Matrix
ZONE | CLIMATE TYPE | MAJOR CITIES | PRIMARY SOLUTION¹ | FRESH AIR DUCTED² | ECONOMY- OR COMFORT-FOCUSED SOLUTION | MULTI-FAMILY NEW CONSTRUCTION SOLUTION |
---|---|---|---|---|---|---|
1 | Hot & Moist | Miami | E100V + 8190FF or 8192A (Dehumidifies incoming ventilation air) | HVAC Return | 8145A or 8126A | 8144NC |
2 | Hot & Moist | Orlando, Mobile, New Orleans, Houston, Austin, San Antonio | E100V + 8190FF or 8192A (Dehumidifies incoming ventilation air) | HVAC Return | 8145A or 8126A | 8144NC |
2 | Hot & Dry | Phoenix, Tucson | 8142A (Mixes ventilation air after cooling or heating) | HVAC Supply | 8142A | |
3 | Warm & Moist | Charlotte, Charleston, Atlanta, Little Rock, Oklahoma City, DFW | E100V + 8190FF or 8192A (Dehumidifies incoming ventilation air) | HVAC Return | 8145A or 8126A | 8144NC |
3 | Warm & Dry | El Paso, Las Vegas, Los Angeles, Sacramento | 8142A (Mixes ventilation air after cooling or heating) | HVAC Supply | 8142A | 8144NC |
3 | Warm & Marine | San Francisco, San Jose | 8142A (Mixes ventilation air after cooling or heating) | HVAC Supply | 8145A or 8126A | 8144NC |
4 | Mixed & Moist | Philadelphia, Washington DC, Baltimore, Nashville, St. Louis, Wichita, Louisville | 8145A (Mixes ventilation air prior to cooling or heating) | HVAC Return | E100V + 8190FF, 8192A or 8126A | 8144NC |
4 | Mixed & Dry | Albuquerque, Amarillo | 8142A (Mixes ventilation air after cooling or heating) | HVAC Supply | 8145A or 8126A | 8144NC |
4 | Mixed & Marine | Portland, Seattle | 8142A (Mixes ventilation air after cooling or heating) | HVAC Supply | 8142A or 8126A | 8144NC |
5 | Cool & Moist | Boston, Pittsburgh, Columbus, Indianapolis, Detroit, Chicago, Des Moines, Omaha | 8145A (Mixes ventilation air prior to cooling or heating) | HVAC Return | 8145A or 8126A | 8144NC |
5 | Cool & Dry | Denver, Salt Lake City, Boise, Reno | 8145A (Mixes ventilation air prior to cooling or heating) | HVAC Supply or Return | 8126A | 8144NC |
6 | Cold & Moist | Toronto, Vancouver, Milwaukee, Madison, Minneapolis-St Paul, Sioux Falls | 8145A (Mixes ventilation air prior to cooling or heating) | HVAC Return | 8126A | 8144NC |
6 | Cold & Dry | Helena, Cheyenne | 8145A (Mixes ventilation air prior to cooling or heating) | HVAC Return | 8126A | 8144NC |
7 | Extreme Cold & Moist | Fargo, Duluth, Calgary, Edmonton | 8145A (Mixes ventilation air prior to cooling or heating) | HVAC Return | 8126A | 8144NC |
¹ Primary AprilAire recommended supply ventilation solution for optimal performance and building code adherence.
² HVAC application considerations based upon moist versus dry air, and proper mixing into the ductwork.
Control & Sanitize
The AprilAire Healthy Air System aims to provide greater health, virus protection, fewer allergens, more productivity, and better sleep by filling homes with Healthy Air.
Download the APP
The AprilAire Healthy Air App works with AprilAire connected devices, providing control from anywhere. It is compatible with AprilAire Wi-Fi thermostats.
Note: AprilAire makes no representations or warranties with respect to specific applications. AprilAire reserves the right to change specifications without notice.