Aprilaire Product Specifications Quick Reference Guide

Aprilaire Product Specifications

Quick Reference Guide | August 2019

For comprehensive product specifications, refer to individual product guides at AprilairePartners.com or call 800.334.6011.

Regional Humidifier Applications

Aprilaire humidifiers can be installed on many different types of HVAC equipment and controlled to provide optimal humidity levels. This application guide is to assist in the selection of the appropriate Aprilaire product based upon geography and heating equipment.

The Aprilaire humidifier product portfolio consists of evaporative flow through, fan-powered products and residential steam. It's important to consider the plenum temperature, air flow (fan speed) and run time (heat call primary, fan only call secondary) when selecting products.

Aprilaire's control strategy will maximize the humidifier run time/ capacity. The automatic humidity controls have an integrated blower activation relay. This relay is factory set to "ON". It will turn on the humidifier and the HVAC blower for humidification without a heat call. This will dramatically increase the capacity of the humidifier. Installations with a manual humidifier control can increase capacity by turning the thermostat fan to "ON". When installing evaporative humidifiers, it's recommended they are plumbed to hot water.

Application Map

This application map assists in the selection of the appropriate Aprilaire product based upon geography and heating equipment.

A map of the United States showing climate zones: Mountain, Midwest/Northeast, Desert (Southwest), South, and Mid-Atlantic/Mid-Southern.

EquipmentMIDWEST/ NORTHEASTMID-ATLANTIC/ MID-SOUTHERNMOUNTAINSOUTHDESERT (SOUTHWEST)
Gas/Oil Furnace-Single Stage or Multi Stage*400/500/600/700/800400/500/600/700/800400/500/600/700/800500/600/700/800800
Gas/Oil Modulating Furnace**700/800700/800700/800700/800800
Heat Pump/Geo-Single Stage or Multi Stage*400/500/600/700/800400/500/600/700/800400/500/600/700/800500/600/700/800800
Heat Pump/Geo-Modulating**700/800700/800700/800700/800800
Boiler With AHU (No Heat Source)800800800800800
Boiler With AHU and Hot Water Coil/ Hydro Air Unit700/800700/800800800800
Boiler865865865865865
Electric Baseboard Heating865865865865865
Humidifying with A/C UnitN/AN/A800800800

*PSC, constant torque ECM **Variable speed ECM +Evaporative performance of bypass humidifiers decreases with lower airflow volume and lower air temperature. Bypass models can be used in these applications if the HVAC system pressure differential between supply and return ducts is at least 0.08 in. wg and air temperature, hot water and continuous fan in the supply duct is at least 100°F.

Humidifiers

Aprilaire HumidifiersModel No.Type of HumidificationUnit Size Width x Height x DepthPlenum OpeningCapacity GPD = Gallons Per DayElectrical DataWater Panel/ Canister
800 Series800
801***
Steam Humidifier
For applications when evaporative units are less practical (attics, crawl spaces, closets, milder winter climates, non-forced-air heating source).
101/8" x 207/8" x 71/8"-11.5 GPD
16.0 GPD
20.5 GPD
30.0 GPD
120V 60Hz 11.5 AMP
120V 60Hz 16 AMP
208V 60Hz 11.5 AMP
208V 60Hz 16 AMP
240V 60Hz 11.5 AMP
240V 60Hz 16 AMP
80
865
866***
Ductless Humidification System
Includes the Model 800, Fan Pack, Model 65 Control and Model 4028 Drain Trap. For homes without forced-air heating systems.
Fan Pack:
14"x 69/10"x 315/16"
Finished Grille:
1613/16" x 9" x 115/16"
-23.3 GPD
34.6 GPD
240V 60Hz 11.5 AMP
240V 60Hz 16 AMP
80LC
700 Series700*
700M**
Powered Unit
Built-in fan that pulls heated air directly from the furnace.
1529/32" x 18" x 1011/32"W: 143/4"
H: 145/16"
18 GPD120V 60Hz 0.8 AMP35
600 Series600*
600M**
Bypass Unit
Uses the furnace blower to move air through a Water Panel®.
153/8" x 153/4" x 103/4"
6" dia. round opening
W: 10"
H: 123/4"
17 GPD24V 60Hz 0.5 AMP35
500 Series500*
500M**
Bypass Unit
Designed for smaller homes.
155/8" x 13" x 103/4"
6" dia. round opening
W: 91/2"
H: 91/2"
12 GPD24V 60Hz 0.5 AMP10
400 Series400*
400M**
Bypass Unit
Uses 100% of water and evaporative technology that eliminates the need for a drain. Conserves Water.
153/8" x 153/4" x 103/4"*
6" dia. round opening
W: 10"
H: 123/4"
17 GPD24V 60Hz 0.5 AMP45
300 Series360
350
Self-contained
Designed for homes with radiators or baseboard heat.
Model 360:
133/4" x 123/4" x 121/2"
Model 350:
133/4" x 123/4" x 15"
-Model 360:
12 GPD
Model 350:
Model 360:
120V 60Hz 0.7 AMP
Model 350:
120V 60Hz 0.9 AMP
35

Humidifier Sizing Guidelines

GPD Needed Per Square Foot Based on Building Structure Tightness

Structure Tightness (8 Ft Ceilings)1000 Ft²1500 Ft²2000 Ft²2500 Ft²3000 Ft²4000 Ft²5000 Ft²
Tight4.3 GPD6.4 GPD8.5 GPD10.6 GPD12.7 GPD17 GPD21.2 GPD
Average8.6 GPD12.8 GPD17 GPD21.3 GPD25.4 GPD34 GPD42.6 GPD
Loose12.7 GPD19.1 GPD25.5 GPD31.8 GPD38.1 GPD51 GPD63.6 GPD

*Automatic Digital Control with Auto-Trac® (shown)

**Manual Control - For those rare occurrences where an automatic control is not practical, Aprilaire offers the same great humidifiers with a mechanical control.

***801 & 866 Modulating Steam Humidifier - For precise RH control. Controls are sold separately.

+ Heat Pumps - Model 400 can be installed in heat pump applications. However, due to the fact that heat pumps deliver lower temperature air to the home than gas furnaces, evaporation will be approximately 60% of rated capacity. (With other Aprilaire models, hot water can be used instead of cold to maximize evaporation. However, due to the nature of the wicking water panel in the Model 400, hot water provides less benefit). As such, your dealer will need to take the size and age of your home into consideration to ensure the Model 400 will provide satisfactory comfort and protection through adequate humidification.

++Model 800LC available for less conductive water 75-300µS/cm and 120VAC applications.

#AHRI Air Conditioning, Heating, and Refrigeration Institute GPD = Gallons Per Day Guideline F

A family of 4 will add 2 gallons of humidity per day through everyday activities like breathing, cooking, bathing and washing. Evaporative capacities assume blower is active 100% of the time, plenum temperature is at 120°F and water is cold.

Bypass Humidifiers - Can be installed on the supply or return plenum.

Water Usage Rate - Models 350, 360 and 700 are 6 gph (gph=gallons per hour); Models 500 and 600 are 3 gph; Model 400 is 0.7 gph; Model 800 is 0.6 to 1.8 gph depending on voltage, amp draw and water quality.

Dehumidifiers

Aprilaire DehumidifiersModel No.Unit SizeCapacity ppd = Pints Per DayWeight lbs.Efficiency @ 80°F/ 60% RHAirflow (CFM)Power @ 80°F/ 60% RHSupply VoltageCurrent Draw @ 80°F/ 60% RHAir FilterPower Cord
1800 Series1830¹W: 12½"
H: 14½"
D: 25"
70 ppd674 pints/
kWh
160757 watts120 VAC 1 Phase
60 Hz
6.3 amps-8' 120 VAC Grounded Plug
1850
1852²
W: 12½"
H: 14½"
D: 27½"
95 ppd704.7 pints/
kWh
265870 watts120 VAC 1 Phase
60 Hz
8.0 amps1" MERV 8Hardwired
1850W³
1870¹W: 19½"
H: 18¾"
D: 30"
130 ppd1136.1 pints/
kWh
310900 watts120 VAC 1 Phase
60 Hz
8.3 amps-8' 120 VAC Grounded Plug
1872¹,²114996 wattsHardwired
1870W¹,³113900 watts

Dehumidifier Sizing Guidelines

The recommended home floor area (ft²) that each listed dehumidifier can dehumidify, assuming 8 ft. ceilings. These are sizing guidelines only. The actual home size is dependent on the exact location of the home, the actual total ventilation rate, occupant living habits, moisture removal characteristics of the air conditioning system and the environmental conditions at which the occupants experience comfort.

Model 1830Model 1850Model 1870
1.00 ACH .50 ACH1.00 ACH .50 ACH1.00 ACH .50 ACH
Region A2800 Ft² 3800 Ft²3800 Ft² 5200 Ft²5200 Ft² 7200 Ft²
Region B2200 Ft² 3400 Ft²3000 Ft² 4700 Ft²3900 Ft² 6500 Ft²
Region C1400 Ft² 2000 Ft²1900 Ft² 2800 Ft²2300 Ft² 3600 Ft²

¹ An ENERGY STAR® certified product

² 1852 and 1872 are on casters

³ 1850W and 1870W are hardwired unit only

ACH = Air Changes per Hour. The tighter the house, the lower the ACH.

Air Cleaners

Aprilaire Air CleanersModel No.Nominal Size (in Inches)Cabinet SizeShipping Weight lbsIncluded FilterCompatable Replacment Filters*
2000 Series221620 x 25W: 6¾" H: 221/16" D: 273/8"20216MERV 16
213CBN, 213, 210
241616 x 25W: 6¾" H: 173/4" D: 301/16"19.25416413CBN, 413, 410
251631 x 28W: 6¾" H: 31" D: 301/16"24.9516513CBN, 513, 510
1000 Series221020 x 25W: 6¾" H: 221/16" D: 273/8"19213MERV 13
216, 213CBN, 210
231020 x 20W: 6¾" H: 203/8" D: 221/16"17313310
241016 x 25W: 6¾" H: 173/4" D: 301/16"19413416, 413CBN, 410
111016 x 20W: 6¾"H: 173/4" D: 221/16"13110MERV 11
113
121020 x 25W: 6¾" H: 221/16" D: 273/8"20210216, 213CBN, 213
131020 x 20W: 6¾" H: 203/8" D: 221/16"15310313
141016 x 25W: 6¾" H: 173/4" D: 301/16"19410416, 413CBN, 413
151031 x 28W: 6¾" H: 31" D: 301/16"28510516, 513CBN, 513
161016 x 25W: 1511/16" H: 1713/16" D: 303/16"31410416, 413CBN, 413
162020 x 25W: 1511/16" H: 221/8" D: 273/8"32.4210216, 213CBN, 213
191025 x 20W: 6¾" H: 251/16" D: 221/16"18910913
5000 Series500016 x 25W: 12" H (front): 183/8" H (back): 173/4" D: 31"35501ELECTRONIC Air Cleaner
-

Filter Grille Air Cleaners*

Aprilaire Filter Grille Air CleanersModel No.Nominal Size (In Inches)Filter ModelShipping Weight
1625FG1116 x 25610
613
16 lbs.
2025FG1120 x 25810
813
18 lbs.

* Included filter model is also available as a replacement option.

*Recommended grille face velocity is 300-450 fpm. To minimize risk of noise, use two filter grilles on systems over 3.5 tons.

Air Cleaner Filters

Removal Efficiency (Based on Particle Size)

0.3–1.0 Microns1.0–3.0 Microns3.0–10.0 Microns
MERV 1695%98%99%
MERV 1363%88%93%
MERV 1137%67%92%
MERV 1022%56%92%
EAC (Model 5000)89%95%98%

Test Method - MERV 10-16 - ASHRAE 52.2.2012, EAP - AHRI 680-2009

Upgrade Kits

Filter No.Used With Space-Gard & Aprilaire Air Cleaner ModelsNominal Size (in inches)Included FilterStatic Pressure Drop (in. w.c.) @ 1200 CFMMaximum Airflow Capacity (in CFM)
1213*220020 x 252130.152000
1413**240016 x 254130.172000

*1213 Upgrade Kit includes 4893 rails and Model 213 MERV 13 Healthy Home Filter

**1413 Upgrade Kit includes 4894 rails and Model 413 MERV 13 Healthy Home Filter

Upgrade Rails

Model No.Compatible WithNominal Size (in inches)Uses Filter ModelMaximum Airflow Capacity (in CFM)
4893*Aprilaire/Space-Gard 2200 or 212020x25210, 213, 213CBN, 2162000
4894**Aprilaire/Space-Gard 2400 or 214016x25410, 413, 413CBN, 4162000
4897Models by (but not limited to): Carrier® Honeywell® Lennox® Ultravation® General® Trion®16x25 20x25610 8102000 2000
489816x20 20x20110, 113 310, 3131200 1200

Replacement Filters

Filter No.Used with Aprilaire Air Cleaner ModelsNominal Size (in inches)Static Pressure Drop (in. w.c.) @ 1200 CFMMaximum Airflow Capacity (in CFM)
2012200 Space-Gard, 2200 Aprilaire*20 x 250.122000
4012400 Space-Gard, 2400 Aprilaire*16 x 250.142000

*Air Cleaner models no longer available.

Thermostat & IAQ Controls

NonProgrammableProgrammableProgrammable with Event-Based™ Air CleaningProgrammable Touch ScreenProgrammable Touch Screen with Humidity ControlIAQ ControlIAQ Control
Residential Model No. Stages8444 1H/1C
8446 2H/1C HP
8448 Universal
2H/2C, 4H/2C HP
8463 1H/1C
8465 2H/1C HP
8466 Universal
2H/2C, 4H/2C HP
8476W(Wi-Fi)
8476 Universal
2H/2C, 4H/2C HP
8600 Universal
2H/2C, 4H/2C HP
8620W(Wi-Fi)
8620 Universal
2H/2C, 4H/2C HP
8910W(Wi-Fi)
8910 Universal
3H/3C, 4H/2C HP
8920W(Wi-Fi) Universal
3H/3C, 4H/2C HP
Home Automation Model No.-88108800882088308840
Dimensions (Width x Height x Depth)51/4" x 41/2" x 1"6" x 415/16" x 115/16"6" x 417/20" x 11/4"71/10" x 417/20" x 1"
Temperature Control• Easy to Read Display
• Simple Setup
• Displays Outdoor Temperature (if equipped)
• Adjustable Differential
• Progressive Recovery
• Heat Blast
Air Cleaning• Event-Based™ Air Cleaning
• Air Cleaning Notice
• Change Filter Alert
Humidifier Control• Automatic or Manual
Humidifier Control
• "Humidifier On" Notice
• Displays Indoor RH
• Energizes HVAC Blower for Humidity
Dehumidifier Control• Controls Humidifier with 24 VAC Dry Contact
• Controls Whole-Home Dehumidifier
Ventilation Control• Controls A/C Equipment for Dehumidification
• Displays Indoor RH
• "Dehumidifier On" Notice
• Energizes HVAC Blower for Dehumidification
• Controls Dehumidifier with 24 VAC Dry Contact
Product Configuration• Programmable for Timed Ventilation
• Programmable for ASHRAE 62.2 Ventilation
• Configurable Temperature and Humidity Limits
• "Ventilation On" Notice
• Controls Air Cleaner and Humid or Dehumid or Vent
• Wired Outdoor Temperature Sensor Included
• Two-Part Design-Only 3 Wires to the Living Space

* Equipment Control Module = 83/5" x 93/5" x 19/10"

= amazon alexa Compatible = Google Assistant Compatible

Zone Control Systems

6000 SERIES PRODUCT CONFIGURATIONS

KitsBlackWhite
2-ZoneModel 6010: 2-Zone Complete Kit**Model 6015: 2-Zone Complete Kit**
3-ZoneModel 6020: 3-Zone Complete KitModel 6025: 3-Zone Complete Kit**

Individual Components

Model 6030: 2-Zone Base

Model 6040: 3-Zone Base

Model 6050: Secondary Zone UI

Zone Control Panels

ModelSpecificationsMaximum Current
UniversalOverall Dimensions
Humidity
Operating Temperature
Shipping Temperature
Voltage
863/100" W x 933/50" H x 143/50" D
5% - 90% RH, non-condensing
32°F - 158°F
-40°F - 180°F
18-30VAC 50/60 Hz
Damper output per zone (fused):
18VA at 158°F, 30VA at 90°F
zone panel and thermostats (fused):
18VA at 158°F, 30VA at 90°F
zone panel consumption: 4VA max
Note: Use 18 or 20 AWG solid (non-stranded) wire
Zoned Comfort Control™ Kits* Available: 6404K & 6403K
Heat Pump OnlyOverall Dimensions
Humidity
Operating Temperature
Shipping Temperature
Voltage
863/100" W x 933/50" H x 143/50" D
5% - 90% RH, non-condensing
32°F - 158°F
-40°F - 180°F
18-30VAC 50/60 Hz
Damper output per zone (fused):
18VA at 158°F, 30VA at 90°F
zone panel and thermostats (fused):
18VA at 158°F, 30VA at 90°F
zone panel consumption: 4VA max
Note: Use 18 or 20 AWG solid (non-stranded) wire
Zoned Comfort Control™ Kits* Available: 6303K & 6302K
Conventional OnlyOverall Dimensions
Humidity
Operating Temperature
Shipping Temperature
Voltage
863/100" W x 933/50" H x 143/50" D
5% - 90% RH, non-condensing
32°F - 158°F
-40°F - 180°F
18-30VAC 50/60 Hz
Damper output per zone (fused):
18VA at 158°F, 30VA at 90°F
zone panel and thermostats (fused):
18VA at 158°F, 30VA at 90°F
zone panel consumption: 4VA max
Note: Use 18 or 20 AWG solid (non-stranded) wire
Zoned Comfort Control™ Kits* Available: 6303K & 6302K

** Kits include outdoor temperature sensor along with duct probe

* Zoned Comfort Control Kits include: Zone panel, 6" duct probe and 24V 40VA universal transformer

Zone Dampers

Rectangular Damper Size & Stock No.*

Nominal Width (in inches)8" (203mm)10" (254mm)12" (305mm)14" (356mm)16" (406mm)18" (457mm)20" (508mm)22" (559mm)24" (610mm)26" (660mm)28" (711mm)30" (762mm)
Side Mount Motor mounted on short dimension
W3 indicates power open/ power closed
8" (203mm)
6721
6721W3
10" (254mm)
6722
6722W3
12" (305mm)
6723
6723W3
14" (356mm)
6724
6724W3
16" (406mm)
6725
6725W3
18" (457mm)
6726
6726W3
20" (508mm)
6727
6727W3
22" (559mm)
6728
6728W3
24" (610mm)
6729
6729W3
26" (660mm)
6730
6730W3
28" (711mm)
6731
6731W3
30" (762mm)
6753
6753W3
6732
6732W3
6733
6733W3
6734
6734W3
6735
6735W3
6736
6736W3
6737
6737W3
6738
6738W3
6739
6739W3
6740
6740W3
6741
6741W3
6742
6742W3
6743
6743W3
6744
6744W3
6745
6745W3
6746
6746W3
6747
6747W3
6748
6748W3
6749
6749W3
6750
6750W3
6751
6751W3
6752
6752W3
6754
6754W3
6755
6755W3
6756
6756W3
6757
6757W3
6758
6758W3
6759
6759W3
6760
6760W3
6761
6761W3
6762
6762W3
6763
6763W3
6764
6764W3
6765
6765W3
6766
6766W3
6767
6767W3
6768
6768W3
6769
6769W3
6770
6770W3
6771
6771W3
6772
6772W3
6773
6773W3
6774
6774W3
6775
6775W3
6776
6776W3
6777
6777W3
6778
6778W3
6779
6779W3
6780
6780W3
6781
6781W3
6782
6782W3
6783
6783W3
6784
6784W3
6785
6785W3
6786
6786W3
6787
6787W3
6788
6788W3
6789
6789W3
6790
6790W3
6791
6791W3
6792
6792W3
6793
6793W3
6794
6794W3
6795
6795W3
6796
6796W3
6797
6797W3
6798
6798W3
Bottom Mount Motor mounted on long dimension8" (203mm)
6721
6721W3
10" (254mm)
6732
6732W3
12" (305mm)
6743
6743W3
14" (356mm)
16" (406mm)
18" (457mm)
20" (508mm)
22" (559mm)
24" (610mm)
26" (660mm)
28" (711mm)
30" (762mm)
6812
6812W3
6813
6813W3
6814
6814W3
6815
6815W3
6816
6816W3
6817
6817W3
6818
6818W3
6819
6819W3
6823
6823W3
6824
6824W3
6825
6825W3
6826
6826W3
6827
6827W3
6828
6828W3
6829
6829W3
6834
6834W3
6835
6835W3
6836
6836W3
6837
6837W3
6838
6838W3
6839
6839W3

* Rectangular Damper Dimension = Nominal width + 3.5"

** 10 day lead time for shaded items

Zone Dampers

Round Damper Size & Stock No.*

Nominal Diameter (in inches)4" (102mm)5" (127mm)6" (152mm)7" (178mm)8" (203mm)9" (229mm)10" (254mm)12" (305mm)14" (356mm)16" (406mm)18" (457mm)20" (508mm)
Zone Damper (Normally open/ power closed)
W3 indicates power open/power closed
--6606
6606W3
6607
6607W3
6608
6608W3
6609
6609W3
6610
6610W3
6612
6612W3
6614
6614W3
6616
6616W3
66186620
H: 103/4"H: 103/4"H: 103/4"H: 103/4"H: 103/4"H: 123/4"H: 143/4"H: 163/4"H: 1931/50"H: 22"
Ventilation Damper (Normally closed/ power opened)---6506
H: 103/4"
6508
H: 103/4"
6510
H: 103/4"
------
Barometric Pressure Relief (Air flow activated)----6108
H: 103/4"
6110
H: 103/4"
6112
H: 123/4"
6114
H: 143/4"
6116
H: 163/4"
---
Static Pressure Relief (Power activated)----6208
H: 8"
6210
H: 10"
6212
H: 12"
6214
H: 14"
6216
H: 16"
6218
H: 18"
6220
H: 20"
Round Slip-In Damper (Normally open/ power closed)6704
W: 34/5"
H: 123/5"
D: 73/10"
6705
W: 34/5"
H: 123/5"
D: 83/10"
6706
W: 34/5"
H: 123/54"
D: 93/10"
6707
W: 34/5"
H: 123/5"
D: 103/10"
6708
W: 34/5"
H: 123/5"
D: 113/10"
6710
W: 35"
H: 123/5"
D: 133/10"
------

* Round Damper Dimension = Nominal diameter + 4.5"

Ventilation

Ventilation Climate Zones

Managing the quality of ventilated air delivered into the home is critical to providing a healthy indoor environment. The requirements change significantly based on climate. Aprilaire ventilation solutions work with the HVAC equipment to remove moisture, harmful particulates and other contaminants such as VOCs. It's critical to use adequate ventilation controls and application guidance to properly ventilate rather than to simply pull air through walls with local exhaust ventilation.

A map of the United States showing climate zones labeled Marine, Dry, Moist, and Warm-Humid, with numerical zone designations (1-7).

SOURCE: 2012 & 2015 International Residential Code - N1101.10 (R301.1). Zones are by county, based factors including mean temperature, warmest month, precipitation and wet bulb temperature.

Use this map and the adjoining application guide to determine the recommended product solution for your climate. These recommendations are based on moisture removal demands, energy savings, and integration with the HVAC equipment.

Ventilation Supply Solutions

ZONECLIMATE TYPEMAJOR CITIESPRIMARY SOLUTION¹FRESH AIR DUCTED²ECONOMY- OR COMFORT-FOCUSED SOLUTIONMULTI-FAMILY NEW CONSTRUCTION SOLUTION
1Hot & MoistMiami8192
Dehumidifies incoming
ventilation air
HVAC Return8140 or 8126X8144NC
2Hot & MoistOrlando, Mobile, New Orleans,
Houston, Austin, San Antonio
8192
Dehumidifies incoming
ventilation air
HVAC Return8140 or 8126X8144NC
2Hot & DryPhoenix, Tucson8142
Mixes ventilation air after
cooling or heating
HVAC Supply8126X8144NC
3Warm & MoistCharlotte, Charleston, Atlanta,
Little Rock, Oklahoma City,
DFW
8192
Dehumidifies incoming
ventilation air
HVAC Return8140 or 8126X8144NC
3Warm & DryEl Paso, Las Vegas, Los
Angeles, Sacramento
8142
Mixes ventilation air after
cooling or heating
HVAC Supply8126X8144NC
3Warm & MarineSan Francisco, San Jose8142
Mixes ventilation air after
cooling or heating
HVAC Supply8140 or 8126X8144NC
4Mixed & MoistPhiladelphia, Washington DC,
Baltimore, Nashville, St. Louis,
Wichita, Louisville
8140
Mixes ventilation air prior
to cooling or heating
HVAC Return8191, 8192 or 8126X8144NC
4Mixed & DryAlbuquerque, Amarillo8142
Mixes ventilation air after
cooling or heating
HVAC Supply8140 or 8126X8144NC
4Mixed & MarinePortland, Seattle8142
Mixes ventilation air after
cooling or heating
HVAC Supply8140 or 8126X8144NC
5Cool & MoistBoston, Pittsburgh, Columbus,
Indianapolis, Detroit, Chicago,
Des Moines, Omaha
8140
Mixes ventilation air prior
to cooling or heating
HVAC Return8126X8144NC
5Cool & DryDenver, Salt Lake City, Boise,
Reno
8140
Mixes ventilation air prior
to cooling or heating
HVAC Supply or Return8142 or 8126X8144NC
6Cold & MoistToronto, Vancouver, Milwaukee,
Madison, Minneapolis-St Paul,
Sioux Falls
8140
Mixes ventilation air prior
to cooling or heating
HVAC Return8126X8144NC
6Cold & DryHelena, Cheyenne8140
Mixes ventilation air prior
to cooling or heating
HVAC Return8126X8144NC
7Extreme Cold & MoistFargo, Duluth, Calgary,
Edmonton
8140
Mixes ventilation air prior
to cooling or heating
HVAC Return8126X8144NC

¹ Primary Aprilaire recommended supply ventilation solution for optimal performance and building code adherence.

² HVAC application considerations based upon moist versus dry air, and proper mixing into the ductwork.

Aprilaire Ventilation Systems

Aprilaire Ventilation SystemsModel No.Unit SizeDehumidification Capacity ppd = Pints Per DayShipping Weight lbs.Airflow 0.2 in. w.c. @ (CFM)Product Description
FRESH AIR VENTILATOR WITH DEHUMIDIFICATION8192W: 12½"
H: 14½"
L: 27½"
95 ppd84.00230The ventilation control is integrated into the Aprilaire whole-home unit. The unit energizes its blower and opens a damper drawing fresh air into the home. If the incoming air is above a set relative humidity percentage, the incoming air is dehumidified.
FRESH AIR VENTILATORS8140
8140NC
W: 142/5"
H: 113/5"
L: 274/5"
-30.50
30.00
225Aprilaire ventilation control energizes a blower in the ventilator and opens an integrated damper delivering fresh air into the return or the supply. NC models do not include an on-board controller so that ventilation can be controlled by a thermostat located within the living space.
8142
8142NC
W: 131/5"
H: 67/10"
L: 119/10"
-12.36
9.80
210
8144NCW: 101/4"
H: 181/8"
D: 101/4"
-20.50130The 8144NC is designed to provide continuous low-volume ventilation for smaller single- and multi-family homes. An 8120X ventilation controller may be added to set the unit for energy code ventilation or use high/low temperature and RH lock outs for comfort set up.
VENTILATION CONTROLLER8120XW: 411/100"
H: 33/5"
D: 159/100"
-.50-The 8120X engages a fan or damper on various Aprilaire ventilation solutions to allow the delivery of fresh air to a supply or return on the HVAC system. Control can be programmed to deliver the correct amount of fresh air required by code or within high/low outdoor temperature and indoor RH lockouts set by the installer or homeowner.
VENTILATION SYSTEM8126XW: 108/25"
H: 103/4"
D: 6"
-6.50-Aprilaire ventilation control energizes a powered damper mounted on the return side of the HVAC blower. When the HVAC blower energizes, negative pressure draws fresh air into the home.
KITCHEN VENTILATION KITS6508KVW: 8"
H: 103/4"
D: 121/3"
-6.00185The Aprilaire 6508KV, 6510KV Kitchen Ventilation Kit is designed to locally provide make-up air to areas where high-CFM range hoods (typically near 400 CFM or above) are used to prevent home depressurization and its consequences.
6510KVW: 10"
H: 103/4"
D: 141/3"
-6.70390
FRESH AIR EXCHANGER (ERV)8100W: 373/8"
H: 2023/40"
D: 123/4"
-87.00130Aprilaire ventilation control (not included) or thermostat energizes blowers in the ventilator drawing fresh air in and exhausting stale air out of the home. The air flow is balanced, eliminating pressure, and energy is transferred between incoming and outgoing air.

Accessories

Aprilaire AccessoriesModel No.Product DescriptionUnit SizeType of WireCompatible Models
8051Flush Mount Sensor
Ideal for residential or light commercial applications where customer requires nothing to be seen on the wall.
Disk:
11/2" dia.
Friction fit in a 1" opening. Air gap
of 1/4" required.
8600
8620
8620W
8910
8910W
8920W
8800
8820
8830
8840
8052Outdoor/Duct Sensor
Designed for outdoor or duct installation including with use of zone control panels.
Probe:
1/4" dia. x 13/4" L
Bracket:
3/4" x 3/4"
18-24 gauge
2 conductor wire
(or more conductors)
8053Surface Mount Sensor
Perfect for light indoor commercial applications to prevent tampering.
W: 31/2"
H: 21/2"
D: 7/8"
80223-Wire to 4-Wire Adapter
Used to add a wire to a thermostat, fix a broken wire or add a common wire to a 4-wire system.
W: 27/8"
H: 13/4"
D: 147/50"
All thermostats
8028Damper Power Distribution Panel
For applications where needed dampers outnumber control capability of any Aprilaire Zone Control Panel.
W: 101/2"
H: 5"
D: 17/10"
18-22 gauge stranded or solid thermostat wire can be used for all wire runsAll zone control panels
6401Expansion Panel
Two-zone expansion panel that supports 2-wire or 3-wire dampers.
W: 101/2"
H: 5"
D: 17/10"
6404
With LCD screen
AUTOMATION MODULES8081Temperature Support Module
Averages up to eight temperature locations per thermostat.
W: 31/2"
H: 21/2"
D: 7/8"
8082Temperature and RH Support Module
Averages four temperatures (on-board or off-board) and four humidity values (on-board only).
W: 31/2"
H: 21/2"
D: 7/8"
Cat 6 or greater8800
8820
8830
8840
8083Flush Temperature and RH Support Module
Averages four temperature and four RH values.
Disk:
11/2" dia.
Cylinder Hole:
1" off wall, 1/4" air gap

PDF preview unavailable. Download the PDF instead.

v1 Adobe PDF Library 15.0 Adobe InDesign CC 14.0 (Macintosh)

Related Documents

Preview Aprilaire Indoor Air Quality Systems: Humidifiers, Dehumidifiers, Air Cleaners, and Ventilation
Comprehensive guide to Aprilaire's range of indoor air quality products, including humidifiers, dehumidifiers, air cleaners, thermostats, zone control systems, and ventilation solutions, with detailed specifications and application guidance.
Preview AprilAire All Product Guide: Quick Reference - Healthy Air Solutions
Comprehensive quick reference guide to AprilAire's range of healthy air solutions, including radon mitigation, air filtration, humidity control, IAQ control, and ventilation systems. Features product specifications, sizing guides, and application information.
Preview AprilAire All Product Guide: Healthy Air Solutions for Every Home
Explore the AprilAire All Product Guide, a comprehensive quick reference for January 2022. Discover solutions for radon mitigation, humidity control, air filtration, fresh air ventilation, and IAQ control. Features detailed product specifications, application guides, and sizing information for residential and commercial use.
Preview Aprilaire Healthy Air System Product Guide: Humidifiers, Dehumidifiers, Air Filtration, Controls & Ventilation
Comprehensive product guide for Aprilaire's Healthy Air System, featuring humidifiers, dehumidifiers, air cleaners, thermostats, zone control systems, and ventilation products. Includes specifications, sizing, and application guidance for residential HVAC systems.
Preview Aprilaire Healthy Air System Product Guide - Humidifiers, Dehumidifiers, Air Cleaners, Controls
Comprehensive product guide for Aprilaire's Healthy Air System, featuring humidifiers, dehumidifiers, air cleaners, thermostats, zone control systems, dampers, and ventilation solutions. Includes specifications, sizing guides, and application details.
Preview Aprilaire Wi-Fi Thermostats with IAQ Control: Smart Home Comfort & Air Quality
Explore Aprilaire's advanced Wi-Fi thermostats offering intuitive control over temperature, humidity, air purity, and fresh air. Enhance home comfort, energy savings, and indoor air quality with smart features and easy app management. View product portfolio and specifications.
Preview Aprilaire Zoned Comfort Control Systems: Product Guide for HVAC Professionals
Comprehensive product guide for Aprilaire's Zoned Comfort Control systems, detailing control panels, dampers, thermostats, and accessories for residential and light commercial HVAC applications. Learn about designing and installing efficient zoning solutions.
Preview Aprilaire Fresh Air Ventilation Product Guide: Improve Home Air Quality
Discover Aprilaire's advanced fresh air ventilation systems, including ventilators, controllers, and ERVs. Enhance indoor air quality, manage humidity, and meet building codes with Aprilaire's energy-efficient solutions for residential and multi-family homes.