Aprilaire Indoor Air Quality Solutions
Quick Reference | January 2020
For more product information, refer to individual product guides at AprilairePartners.com or call 800.334.6011.
Humidifiers
Aprilaire offers a range of humidifiers designed to maintain optimal indoor humidity levels, improving comfort and protecting homes from the effects of dry air. Models include steam humidifiers, fan-powered units, and bypass units, suitable for various HVAC systems and climates.
Model | Type of Humidification | Unit Size (W x H x D) | Capacity (Gallons Per Day) | Electrical Data |
800 Series (800, 801, 865, 866) | Steam Humidifier | 10 1/8" x 20 7/8" x 7 1/8" | 11.5 GPD, 16.0 GPD, 20.5 GPD, 30.0 GPD, 23.3 GPD, 34.6 GPD | 120V 60Hz 11.5 AMP / 16 AMP; 208V 60Hz 11.5 AMP / 16 AMP; 240V 60Hz 11.5 AMP / 16 AMP |
800 (Fan Pack) | Ductless Humidification System | Fan Pack: 14" x 6 29/32" x 3 15/16"; Finished Grille: 16 3/16" x 9" x 13/32" | - | - |
700 Series (700, 700M) | Powered Unit (Built-in fan) | 15 29/32" x 18" x 10 11/32" | 18 GPD | 120V 60Hz 0.8 AMP |
600 Series (600, 600M) | Bypass Unit (Uses furnace blower) | 15 3/8" x 15 3/4" x 10 3/4" (6" dia. round opening) | 17 GPD | 24V 60Hz 0.5 AMP |
500 Series (500, 500M) | Bypass Unit (For smaller homes) | 15 5/8" x 13" x 10 3/4" (6" dia. round opening) | 12 GPD | 24V 60Hz 0.5 AMP |
400 Series (400, 400M) | Bypass Unit (Conserves water, no drain needed) | 15 3/8" x 15 3/4" x 10 3/4" (6" dia. round opening) | 17 GPD | 24V 60Hz 0.5 AMP |
360 | Self-contained (For radiators/baseboard heat) | 13 3/4" x 12 3/4" x 12 1/2" | 12 GPD | 120V 60Hz 0.7 AMP |
350 | Self-contained (For radiators/baseboard heat) | 13 3/4" x 12 3/4" x 15" | 12 GPD | 120V 60Hz 0.9 AMP |
BUMPER to BUMPER 5-YEAR WARRANTY
Humidifier Sizing Guidelines (GPD Needed Per Square Foot Based on Building Structure Tightness):
Square Footage | Tight Structure (GPD/Sq Ft) | Average Structure (GPD/Sq Ft) | Loose Structure (GPD/Sq Ft) |
1000 | 4.3 | 8.6 | 12.7 |
1500 | 6.4 | 12.8 | 19.1 |
2000 | 8.5 | 17.0 | 25.5 |
2500 | 10.6 | 21.3 | 31.8 |
3000 | 12.7 | 25.4 | 38.1 |
4000 | 17.0 | 34.0 | 51.0 |
5000 | 21.2 | 42.6 | 63.6 |
Note: Evaporative capacities assume blower is active 100% of the time, plenum temperature is at 120°F, and water is cold. Model 400 performance may be reduced with heat pumps due to lower air temperatures.
Regional Humidifier Applications
Aprilaire humidifiers can be installed on various HVAC systems. Selection depends on geography, heating equipment, plenum temperature, airflow, and run time. Automatic controls often include a blower activation relay. For manual controls, setting the thermostat fan to "ON" can increase capacity. Plumbing evaporative humidifiers to hot water is recommended.
Application Map & Climate Zone Recommendations:
Equipment | Midwest/ Northeast | Mid-Atlantic/ Mid-Southern | Mountain | South | Desert (Southwest) |
Gas/Oil Furnace - Single Stage or Multi Stage* | 400/500/600/700/800 | 400/500/600/700/800 | 400/500/600/700/800 | 500/600/700/800 | 800 |
Gas/Oil Modulating Furnace** | 700/800 | 700/800 | 700/800 | 700/800 | 800 |
Heat Pump/Geo - Single Stage or Multi Stage* | 400/500/600/700/800 | 400/500/600/700/800 | 400/500/600/700/800 | 500/600/700/800 | 800 |
Heat Pump/Geo - Modulating** | 700/800 | 700/800 | 700/800 | 700/800 | 800 |
Boiler With AHU (No Heat Source) | 800 | 800 | 800 | 800 | 800 |
Boiler With AHU and Hot Water Coil/Hydro Air Unit | 700/800 | 700/800 | 800 | 800 | 800 |
Boiler | 865 | 865 | 865 | 865 | 865 |
Electric Baseboard Heating | 865 | 865 | 865 | 865 | 865 |
Humidifying with A/C Unit | N/A | N/A | N/A | 800 | 800 |
*PSC, constant torque ECM **Variable speed ECM. Evaporative performance of bypass humidifiers decreases with lower airflow volume and lower air temperature. Bypass models can be used if HVAC system pressure differential is at least 0.08 in. w.c. and air temperature, hot water, and continuous fan are at least 100°F.
Dehumidifiers
Aprilaire dehumidifiers are designed to control excess moisture in homes, preventing mold, mildew, and musty odors. They are available in various capacities to suit different home sizes and humidity levels.
Model | Unit Size (W x H x D) | Capacity (Pints Per Day @ 80°F/60% RH) | Weight (lbs) | Efficiency (Pints/kWh @ 80°F/60% RH) | Airflow (CFM) | Power @ 80°F/60% RH | Supply Current Draw @ 80°F/60% RH | Filter | Power Cord |
1830 / 1830W** | 12 1/2" x 14 1/2" x 25" | 70 ppd | 67 | 4 pints/kWh | 160 | 757 watts | 6.3 amps | - | 8' 120 VAC Grounded Plug |
1850 / 1852* / 1850W** | 12 1/2" x 14 1/2" x 27 1/2" | 95 ppd | 70 | 4.7 pints/kWh | 265 | 870 watts | 8.0 amps | - | Hardwired |
1870 / 1872* / 1870W** | 19 3/4" x 18 3/4" x 30" | 130 ppd | 113 | 6.1 pints/kWh | 310 | 900 watts | 8.3 amps | 1" MERV 8 | 8' 120 VAC Grounded Plug |
BUMPER to BUMPER 5-YEAR WARRANTY
Dehumidifier Sizing Guidelines (Recommended Home Floor Area ft²):
Model | 1.00 ACH | 0.50 ACH | ||
2800 Ft² | 3800 Ft² | 3800 Ft² | 5200 Ft² | |
1830 | 2200 Ft² | 3400 Ft² | 3000 Ft² | 4700 Ft² |
1850 | 1400 Ft² | 2000 Ft² | 1900 Ft² | 2800 Ft² |
1870 | 5200 Ft² | 7200 Ft² | 3900 Ft² | 6500 Ft² |
*1852 and 1872 are on casters. **1830W, 1850W and 1870W are hardwired units only. ACH = Air Changes per Hour. Tighter houses have lower ACH.
Air Cleaners
Aprilaire air cleaners capture airborne particles like dust, pollen, mold spores, and pet dander, improving indoor air quality. They are available in various MERV ratings and configurations, including whole-home electronic air cleaners and filter grille air cleaners.
Series | Model | Nominal Size (in Inches) | Cabinet Size (W x H x D) | Shipping Weight (lbs) | Included Filter | Compatible Replacement Filters* |
2000 Series | 2216 | 20 x 25 | 6 3/4" x 22 1/16" x 27 3/8" | 20 | MERV 16 (216) | 213CBN, 213, 210 |
2416 | 16 x 25 | 6 3/4" x 17 3/4" x 30 1/16" | 19.25 | MERV 16 (416) | 413CBN, 413, 410 | |
2516 | 31 x 28 | 6 3/4" x 31" x 30 1/16" | 24.9 | MERV 16 (516) | 513CBN, 513, 510 | |
2210 | 20 x 25 | 6 3/4" x 22 1/16" x 27 3/8" | 19 | MERV 13 (213) | 216, 213CBN, 210 | |
2310 | 20 x 20 | 6 3/4" x 20 3/8" x 22 1/16" | 17 | MERV 13 (313) | 310 | |
2410 | 16 x 25 | 6 3/4" x 17 3/4" x 30 1/16" | 19 | MERV 13 (413) | 416, 413CBN, 410 | |
1110 | 16 x 20 | 6 3/4" x 17 3/4" x 22 1/16" | 13 | MERV 11 (110) | 113 | |
1210 | 20 x 25 | 6 3/4" x 22 1/16" x 27 3/8" | 20 | MERV 11 (210) | 216, 213CBN, 213 | |
1310 | 20 x 20 | 6 3/4" x 20 3/8" x 22 1/16" | 15 | MERV 11 (310) | 313 | |
1410 | 16 x 25 | 6 3/4" x 17 3/4" x 30 1/16" | 19 | MERV 11 (410) | 416, 413CBN, 413 | |
1000 Series | 1510 | 31 x 28 | 6 3/4" x 31" x 30 1/16" | 28 | MERV 11 (510) | 516, 513CBN, 513 |
1610 | 16 x 25 | 15 11/16" x 17 13/16" x 30 3/16" | 31 | MERV 13 (413) | 410 | |
1620 | 20 x 25 | 15 11/16" x 22 1/8" x 27 3/8" | 32.4 | MERV 13 (513) | 510 | |
1910 | 25 x 20 | 6 3/4" x 25 1/16" x 22 1/16" | 18 | MERV 13 (613) | 610 | |
5000 Series | 5000 | 16 x 25 | 12" x 18 3/8" (front) / 17 3/4" (back) x 31" | 35 | MERV 13 (913) | 910 |
*Included filter model is also available as a replacement option.
Filter Grille Air Cleaners:
Model No. | Nominal Size (in Inches) | Filter Model | Shipping Weight |
1625FG11 | 16 x 25 | 610 | 16 lbs. |
1625FG13 | 16 x 25 | 613 | 16 lbs. |
2025FG11 | 20 x 25 | 810 | 18 lbs. |
2025FG13 | 20 x 25 | 813 | 18 lbs. |
Recommended grille face velocity is 300-450 fpm. For systems over 3.5 tons, use two filter grilles to minimize noise risk.
Air Cleaner Filters - Pressure Drop Chart (Static Pressures at Variable CFM in. w.c.):
Filter No. | MERV Rating | 200 CFM | 400 CFM | 600 CFM | 800 CFM | 1000 CFM | 1200 CFM | 1400 CFM | 1600 CFM | 1800 CFM | 2000 CFM | 2200 CFM | 2400 CFM | 2600 CFM | 2800 CFM | 3000 CFM |
216 | MERV 16 ALLERGY & ASTHMA | 0.06 | 0.09 | 0.13 | 0.17 | 0.23 | 0.29 | 0.36 | - | - | - | - | - | - | - | - |
416 | 0.07 | 0.10 | 0.13 | 0.18 | 0.24 | 0.31 | - | - | - | - | - | - | - | - | - | |
516 | 0.04 | 0.05 | 0.07 | 0.09 | 0.10 | 0.13 | 0.15 | 0.18 | 0.21 | 0.24 | 0.27 | 0.31 | - | - | - | |
113 | MERV 13 HEALTHY HOME | 0.03 | 0.07 | 0.11 | 0.16 | 0.22 | 0.29 | - | - | - | - | - | - | - | - | - |
213 | 0.02 | 0.04 | 0.06 | 0.09 | 0.12 | 0.15 | 0.19 | 0.23 | 0.27 | 0.31 | - | - | - | - | - | |
313 | 0.03 | 0.05 | 0.09 | 0.13 | 0.17 | 0.23 | - | - | - | - | - | - | - | - | - | |
413 | 0.02 | 0.05 | 0.07 | 0.10 | 0.14 | 0.17 | 0.22 | 0.26 | 0.31 | 0.37 | - | - | - | - | - | |
513 | 0.01 | 0.02 | 0.04 | 0.05 | 0.05 | 0.07 | 0.08 | 0.10 | 0.11 | 0.13 | 0.15 | 0.17 | 0.18 | 0.20 | 0.23 | |
613 | 0.02 | 0.05 | 0.07 | 0.10 | 0.14 | 0.17 | 0.22 | 0.26 | 0.31 | 0.37 | - | - | - | - | - | |
813 | 0.02 | 0.04 | 0.06 | 0.09 | 0.12 | 0.15 | 0.19 | 0.23 | 0.27 | 0.31 | - | - | - | - | - | |
913 | 0.04 | 0.07 | 0.10 | 0.13 | 0.17 | 0.22 | 0.25 | 0.30 | 0.35 | - | - | - | - | - | - | |
213CBN | MERV 13 ODOR REDUCTION | 0.04 | 0.07 | 0.10 | 0.13 | 0.17 | 0.21 | 0.25 | 0.30 | 0.35 | - | - | - | - | - | - |
413CBN | 0.04 | 0.07 | 0.10 | 0.14 | 0.19 | 0.24 | 0.29 | 0.36 | 0.43 | - | - | - | - | - | - | |
513CBN | 0.03 | 0.04 | 0.05 | 0.07 | 0.08 | 0.10 | 0.12 | 0.15 | 0.17 | 0.20 | 0.22 | 0.25 | 0.29 | 0.32 | - | |
110 | MERV 11 CLEAN AIR | 0.02 | 0.05 | 0.06 | 0.10 | 0.14 | 0.20 | - | - | - | - | - | - | - | - | - |
210 | 0.02 | 0.03 | 0.04 | 0.06 | 0.08 | 0.11 | 0.13 | 0.16 | 0.19 | 0.22 | - | - | - | - | - | |
310 | 0.02 | 0.04 | 0.06 | 0.10 | 0.14 | 0.19 | - | - | - | - | - | - | - | - | - | |
410 | 0.02 | 0.03 | 0.05 | 0.07 | 0.09 | 0.12 | 0.15 | 0.19 | 0.22 | 0.27 | - | - | - | - | - | |
510 | 0.02 | 0.02 | 0.03 | 0.04 | 0.04 | 0.05 | 0.06 | 0.07 | 0.09 | 0.10 | 0.12 | 0.14 | 0.15 | 0.17 | 0.19 | |
610 | 0.02 | 0.03 | 0.05 | 0.07 | 0.09 | 0.12 | 0.15 | 0.19 | 0.22 | 0.27 | - | - | - | - | - | |
810 | 0.02 | 0.03 | 0.04 | 0.06 | 0.08 | 0.11 | 0.13 | 0.16 | 0.19 | 0.22 | - | - | - | - | - | |
910 | - | 0.03 | 0.05 | 0.07 | 0.09 | 0.12 | 0.15 | 0.18 | 0.22 | 0.27 | - | - | - | - | - | |
201 | EAC MERV 10 | 0.02 | 0.04 | 0.05 | 0.08 | 0.10 | 0.12 | 0.15 | 0.18 | 0.21 | 0.25 | - | - | - | - | - |
401 | 0.02 | 0.04 | 0.05 | 0.08 | 0.10 | 0.14 | 0.17 | 0.21 | 0.25 | 0.29 | - | - | - | - | - | |
501 | 0.02 | 0.04 | 0.05 | 0.08 | 0.10 | 0.14 | 0.17 | 0.21 | 0.25 | 0.29 | - | - | - | - | - |
*Highest value shown is maximum recommended airflow capacity.
Air Cleaner Filters - Removal Efficiency (Based on Particle Size):
0.3-1.0 Microns | 1.0-3.0 Microns | 3.0-10.0 Microns | |
MERV 16 | 95% | 98% | 99% |
MERV 13 | 63% | 88% | 93% |
MERV 11 | 37% | 67% | 92% |
MERV 10 | 22% | 56% | 92% |
EAC (Model 5000) | 89% | 95% | 98% |
Test Method: MERV 10-16 = ASHRAE 52.2.2012, EAC = AHRI 680-2009
Upgrade Kits:
Kit Model | Compatible With | Nominal Size (in inches) | Included Filter | Rails Model Number | Static Pressure Drop (in. w.c.) @ 1200 CFM | Maximum Airflow Capacity (in CFM) |
1213 | Aprilaire/Space-Gard 2200 | 20 x 25 | 213 | 4893 | 0.15 | 2000 |
1413 | Aprilaire/Space-Gard 2400 | 16 x 25 | 413 | 4894 | 0.17 | 2000 |
Upgrade Rails:
Rails Model | Compatible With | Nominal Size (in inches) | Uses Filter Model | Maximum Airflow Capacity (in CFM) |
4893 | Aprilaire/Space-Gard 2200 or 2120 | 20x25 | 210, 213, 213CBN | 2000 |
4894 | Aprilaire/Space-Gard 2400 or 2140 | 16x25 | 410, 413, 413CBN | 2000 |
4897 | Models by (but not limited to): Carrier®, Honeywell®, Lennox®, Ultravation®, General®, Trion® | 16x25 | 610, 613 | 2000 |
4898 | 20x25 | 810, 813 | 2000 | |
16x20 | 110, 113 | 1200 | ||
20x20 | 310, 313 | 1200 |
Replacement Filters:
Filter No. | Used with AprilAire Air Cleaner Models | Nominal Size (in inches) | Static Pressure Drop (in. w.c.) @ 1200 CFM | Maximum Airflow Capacity (in CFM) |
201 | 2200 Space-Gard, 2200 Aprilaire* | 20 x 25 | 0.12 | 2000 |
401 | 2400 Space-Gard, 2400 Aprilaire* | 16 x 25 | 0.14 | 2000 |
*Air Cleaner models no longer available.
Thermostat & IAQ Controls
Aprilaire offers a range of thermostats and Indoor Air Quality (IAQ) controls to manage home comfort, including temperature, humidity, air cleaning, and ventilation. Models range from non-programmable to advanced touch-screen programmable units with Wi-Fi capabilities.
Category | Model No. | Stages | Dimensions (W x H x D) | Features |
NonProgrammable | 8444 | 1H/1C | - | Temperature Control |
8446 | 2H/1C HP | - | Temperature Control | |
8448 | 2H/2C, 4H/2C HP | - | Temperature Control | |
Programmable | 8463 | 1H/1C | - | Temperature Control, Air Cleaning, Humidifier Control |
8465 | 2H/1C HP | - | Temperature Control, Air Cleaning, Humidifier Control | |
8466 | 2H/2C, 4H/2C HP | - | Temperature Control, Air Cleaning, Humidifier Control | |
Programmable with Event-Based™ Air Cleaning** | 8476W(Wi-Fi) | 2H/2C, 4H/2C HP | - | Temperature Control, Air Cleaning, Humidifier Control, Dehumidifier Control, Ventilation Control, Easy to Read Display, Simple Setup, Displays Outdoor Temperature, Adjustable Differential, Progressive Recovery, Heat Blast, Event-Based™ Air Cleaning, Air Cleaning Notice, Change Filter Alert |
8476 | 2H/2C, 4H/2C HP | - | Same as 8476W without Wi-Fi | |
Programmable Touch Screen | 8600 | 2H/2C, 4H/2C HP | 5 1/4" x 4 1/2" x 1" | Temperature Control, Air Cleaning, Humidifier Control, Dehumidifier Control, Ventilation Control, Easy to Read Display, Simple Setup, Displays Outdoor Temperature, Adjustable Differential, Progressive Recovery, Heat Blast |
8620W(Wi-Fi) | 2H/2C, 4H/2C HP | 6" x 4 15/16" x 1 15/16" | Temperature Control, Air Cleaning, Humidifier Control, Dehumidifier Control, Ventilation Control, Easy to Read Display, Simple Setup, Displays Outdoor Temperature, Adjustable Differential, Progressive Recovery, Heat Blast, Event-Based™ Air Cleaning, Air Cleaning Notice, Change Filter Alert, Automatic or Manual Humidifier Control, "Humidifier On" Notice, Displays Indoor RH, Energizes HVAC Blower for Humidity Controls, Humidifier with 24 VAC Dry Contact, Controls Whole-Home Dehumidifier Controls, A/C Equipment for Dehumidification, Displays Indoor RH, "Dehumidifier On" Notice, Energizes HVAC Blower for Dehumidification, Controls Dehumidifier with 24 VAC Dry Contact, Programmable for Timed Ventilation, Programmable for ASHRAE 62.2 Ventilation, Configurable Temperature and Humidity Limits, "Ventilation On" Notice | |
8620 | 2H/2C, 4H/2C HP | 6" x 4 15/16" x 1 15/16" | Same as 8620W without Wi-Fi | |
Programmable Touch Screen with IAQ Control** | 8910W(Wi-Fi) | 3H/3C, 4H/2C HP | 6" x 4 17/20" x 1 1/4" | Controls Air Cleaner and Humid or Dehumid or Vent, Wired Outdoor Temperature Sensor Included |
8910 | 3H/3C, 4H/2C HP | 6" x 4 17/20" x 1 1/4" | Controls Air Cleaner and Humid or Dehumid or Vent, Wired Outdoor Temperature Sensor Included | |
8920W(Wi-Fi) | 3H/3C, 4H/2C HP | 7 1/10" x 4 17/20" x 1" | Controls Air Cleaner and Humid, Dehumid and Vent, Wired Outdoor Temperature Sensor Included | |
Home Automation | 8810 | - | - | - |
8800 | - | - | - | |
8820 | - | - | - | |
8830 | - | - | - | |
8840 | - | - | - |
** IAQ Control features are available on specific models.
Zone Control Systems
Aprilaire Zone Control Systems allow for customized temperature and comfort settings in different areas of a home, improving efficiency and occupant comfort. Systems are available for various HVAC types including heat pumps and conventional systems.
Series | Model | Description | Overall Dimensions (W x H x D) | Humidity | Operating Temperature | Shipping Temperature | Voltage | Maximum Current |
6000 Series (Kits) | 6010 | 2-Zone Complete Kit* | - | 5%-90% RH, non-condensing | 32°F–158°F | -40°F–180°F | 18-30VAC 50/60 Hz | Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; Zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; Zone panel consumption: 4VA max |
6015 | 2-Zone Complete Kit* | - | - | - | - | - | - | |
6020 | 3-Zone Complete Kit* | - | - | - | - | - | - | |
6025 | 3-Zone Complete Kit* | - | - | - | - | - | - | |
6030 | 2-Zone Base Model | - | - | - | - | - | - | |
6040 | 3-Zone Base Model | - | - | - | - | - | - | |
6050 | Secondary Zone UI | - | - | - | - | - | - | |
6035 | 2-Zone Base Model | - | - | - | - | - | - | |
6045 | 3-Zone Base Model | - | - | - | - | - | - | |
6055 | Secondary Zone UI | - | - | - | - | - | - | |
Zone Control Panels (Universal) | 6404 | 4 Zone Universal Multistage (expandable to 12) | 8 63/100" W x 9 33/50" H x 14 3/50" D | 5%-90% RH, non-condensing | 32°F–158°F | -40°F–180°F | 18-30VAC 50/60 Hz | Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; Zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; Zone panel consumption: 4VA max |
6403 | 3 Zone Universal Multistage | 8 63/100" W x 9 33/50" H x 14 3/50" D | 5%-90% RH, non-condensing | 32°F–158°F | -40°F–180°F | 18-30VAC 50/60 Hz | Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; Zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; Zone panel consumption: 4VA max | |
Zone Control Panels (Heat Pump Only) | 6303 | 3 Zone Heat Pump | 8 63/100" W x 9 33/50" H x 14 3/50" D | 5%-90% RH, non-condensing | 32°F–158°F | -40°F–180°F | 18-30VAC 50/60 Hz | Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; Zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; Zone panel consumption: 4VA max |
6302 | 2 Zone Heat Pump | 8 63/100" W x 9 33/50" H x 14 3/50" D | 5%-90% RH, non-condensing | 32°F–158°F | -40°F–180°F | 18-30VAC 50/60 Hz | Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; Zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; Zone panel consumption: 4VA max | |
Zone Control Panels (Conventional Only) | 6203 | 3 Zone Heat/Cool | 8 63/100" W x 9 33/50" H x 14 3/50" D | 5%-90% RH, non-condensing | 32°F–158°F | -40°F–180°F | 18-30VAC 50/60 Hz | Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; Zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; Zone panel consumption: 4VA max |
6202 | 2 Zone Heat/Cool | 8 63/100" W x 9 33/50" H x 14 3/50" D | 5%-90% RH, non-condensing | 32°F–158°F | -40°F–180°F | 18-30VAC 50/60 Hz | Damper output per zone (fused): 18VA at 158°F, 30VA at 90°F; Zone panel and thermostats (fused): 18VA at 158°F, 30VA at 90°F; Zone panel consumption: 4VA max |
*Kits include outdoor temperature sensor and duct probe. **Zoned Comfort Control Kits include: Zone panel, 6" duct probe and 24V 40VA universal transformer. Note: Use 18 or 20 AWG solid (non-stranded) wire.
Zone Dampers
Aprilaire offers a variety of zone dampers, including rectangular and round types, designed to control airflow to specific zones within an HVAC system. Dampers are available in normally open/power closed and normally closed/power opened configurations, with options for side or bottom mount motors.
Rectangular Dampers
Nominal Width (in inches) | 8" | 10" | 12" | 14" | 16" | 18" | 20" | 22" | 24" | 26" | 28" | 30" |
Side Mount (Motor on short dimension) | 6721 | 6722 | 6723 | 6724 | 6725 | 6726 | 6727 | 6728 | 6729 | 6730 | 6731 | 6753 |
W3 (Power Open/Closed) | 6721W3 | 6722W3 | 6723W3 | 6724W3 | 6725W3 | 6726W3 | 6727W3 | 6728W3 | 6729W3 | 6730W3 | 6731W3 | 6753W3 |
10" (254mm) | 6732 | 6733 | 6734 | 6735 | 6736 | 6737 | 6738 | 6739 | 6740 | 6741 | 6742 | - |
W3 (Power Open/Closed) | 6732W3 | 6733W3 | 6734W3 | 6735W3 | 6736W3 | 6737W3 | 6738W3 | 6739W3 | 6740W3 | 6741W3 | 6742W3 | - |
12" (305mm) | 6743 | 6744 | 6745 | 6746 | 6747 | 6748 | 6749 | 6750 | 6751 | 6752 | - | - |
W3 (Power Open/Closed) | 6743W3 | 6744W3 | 6745W3 | 6746W3 | 6747W3 | 6748W3 | 6749W3 | 6750W3 | 6751W3 | 6752W3 | - | - |
14" (356mm) | 6754 | 6755 | 6756 | 6757 | 6758 | 6759 | 6760 | 6761 | 6762 | - | - | - |
W3 (Power Open/Closed) | 6754W3 | 6755W3 | 6756W3 | 6757W3 | 6758W3 | 6759W3 | 6760W3 | 6761W3 | 6762W3 | - | - | - |
16" (406mm) | 6763 | 6764 | 6765 | 6766 | 6767 | 6768 | 6769 | 6770 | - | - | - | - |
W3 (Power Open/Closed) | 6763W3 | 6764W3 | 6765W3 | 6766W3 | 6767W3 | 6768W3 | 6769W3 | 6770W3 | - | - | - | - |
18" (457mm) | 6771 | 6772 | 6773 | 6774 | 6775 | 6776 | 6777 | - | - | - | - | - |
20" (508mm) | 6778 | 6779 | 6780 | 6781 | 6782 | 6783 | - | - | - | - | - | - |
22" (559mm) | 6784 | 6785 | 6786 | 6787 | 6788 | - | - | - | - | - | - | - |
24" (610mm) | 6789 | 6790 | 6791 | 6792 | - | - | - | - | - | - | - | - |
26" (660mm) | 6793 | 6794 | 6795 | - | - | - | - | - | - | - | - | - |
28" (711mm) | 6796 | 6797 | - | - | - | - | - | - | - | - | - | - |
30" (762mm) | 6798 | - | - | - | - | - | - | - | - | - | - | - |
Bottom Mount (Motor on long dimension) | 8" (203mm) | 10" (254mm) | 12" (305mm) | 14" (356mm) | 16" (406mm) | 18" (457mm) | 20" (508mm) | 22" (559mm) | 24" (610mm) | 26" (660mm) | 28" (711mm) | 30" (762mm) |
6721 | 6732 | 6743 | 6754 | 6763 | 6771 | 6778 | 6784 | 6789 | 6793 | 6796 | 6798 | |
W3 (Power Open/Closed) | 6721W3 | 6732W3 | 6743W3 | 6754W3 | 6763W3 | 6771W3 | 6778W3 | 6784W3 | 6789W3 | 6793W3 | 6796W3 | 6798W3 |
Rectangular Damper Dimension = Nominal width + 3.5 inches. 10-day lead time for shaded items.
Round Dampers
Nominal Diameter (in inches) | 4" | 5" | 6" | 7" | 8" | 9" | 10" | 12" | 14" | 16" | 18" | 20" |
Zone Damper (Normally open/power closed) | 6606 | 6607 | 6608 | 6609 | 6610 | 6612 | 6614 | 6616 | 6618 | 6620 | - | - |
W3 (Power Open/Closed) | 6606W3 | 6607W3 | 6608W3 | 6609W3 | 6610W3 | 6612W3 | 6614W3 | 6616W3 | 6618W3 | 6620W3 | - | - |
Ventilation Damper (Normally closed/power opened) | 6506 | - | 6508 | - | 6510 | - | - | - | - | - | - | - |
Barometric Pressure Relief (Air flow activated) | 6108 | - | 6110 | - | 6112 | - | 6114 | - | 6116 | - | - | - |
Static Pressure Relief (Power activated) | 6208 | - | 6210 | - | 6212 | - | 6214 | - | 6216 | - | 6218 | 6220 |
Round Slip-In Damper (Normally open/power closed) | 6704 | 6705 | 6706 | 6707 | 6708 | 6710 | - | - | - | - | - | - |
*Round Damper Dimension = Nominal diameter + 4.5 inches. 10-day lead time for shaded items.
Ventilation
Aprilaire ventilation systems manage indoor air quality by introducing fresh outdoor air while exhausting stale indoor air, helping to remove moisture, particulates, and contaminants. Systems include fresh air ventilators with dehumidification, fresh air ventilators, ventilation controllers, and fresh air exchangers (ERV).
Ventilation Climate Zones
The International Residential Code defines ventilation zones based on climate factors like temperature, precipitation, and wet bulb temperature. These zones influence the requirements for managing ventilated air to ensure a healthy indoor environment.
Climate Zone Map Description: The map divides regions into categories such as Hot & Moist, Hot & Dry, Warm & Moist, Warm & Dry, Mixed & Moist, Mixed & Dry, Cool & Moist, Cool & Dry, and Extreme Cold & Moist. Specific zones are indicated by numbers (1-7) and color-coded regions.
Ventilation Supply Solutions
Aprilaire provides various ventilation solutions tailored for residential new construction based on climate zones.
ZONE | CLIMATE TYPE | MAJOR CITIES | PRIMARY SOLUTION¹ | FRESH AIR DUCTED² | ECONOMY- OR COMFORT-FOCUSED SOLUTION | MULTI-FAMILY NEW CONSTRUCTION SOLUTION |
1 | Hot & Moist | Miami | 8192 (Dehumidifies incoming ventilation air) | HVAC Return | 8140 or 8126X | 8144NC |
2 | Hot & Moist | Orlando, Mobile, New Orleans, Houston, Austin, San Antonio | 8192 (Dehumidifies incoming ventilation air) | HVAC Return | 8140 or 8126X | 8144NC |
2 | Hot & Dry | Phoenix, Tucson | 8142 (Mixes ventilation air after cooling or heating) | HVAC Supply | 8126X | 8144NC |
3 | Warm & Moist | Charlotte, Charleston, Atlanta, Little Rock, Oklahoma City, DFW | 8192 (Dehumidifies incoming ventilation air) | HVAC Return | 8140 or 8126X | 8144NC |
3 | Warm & Dry | El Paso, Las Vegas, Los Angeles, Sacramento | 8142 (Mixes ventilation air after cooling or heating) | HVAC Supply | 8126X | 8144NC |
3 | Warm & Marine | San Francisco, San Jose | 8142 (Mixes ventilation air after cooling or heating) | HVAC Supply | 8140 or 8126X | 8144NC |
4 | Mixed & Moist | Philadelphia, Washington DC, Baltimore, Nashville, St. Louis, Wichita, Louisville | 8140 (Mixes ventilation air prior to cooling or heating) | HVAC Return | 8191, 8192 or 8126X | 8144NC |
4 | Mixed & Dry | Albuquerque, Amarillo | 8142 (Mixes ventilation air after cooling or heating) | HVAC Supply | 8140 or 8126X | 8144NC |
4 | Mixed & Marine | Portland, Seattle | 8142 (Mixes ventilation air after cooling or heating) | HVAC Supply | 8140 or 8126X | 8144NC |
5 | Cool & Moist | Boston, Pittsburgh, Columbus, Indianapolis, Detroit, Chicago, Des Moines, Omaha | 8140 (Mixes ventilation air prior to cooling or heating) | HVAC Return | 8126X | 8144NC |
5 | Cool & Dry | Denver, Salt Lake City, Boise, Reno | 8140 (Mixes ventilation air prior to cooling or heating) | HVAC Supply or Return | 8142 or 8126X | 8144NC |
6 | Cold & Moist | Toronto, Vancouver, Milwaukee, Madison, Minneapolis-St Paul, Sioux Falls | 8140 (Mixes ventilation air prior to cooling or heating) | HVAC Return | 8126X | 8144NC |
6 | Cold & Dry | Helena, Cheyenne | 8140 (Mixes ventilation air prior to cooling or heating) | HVAC Return | 8126X | 8144NC |
7 | Extreme Cold & Moist | Fargo, Duluth, Calgary, Edmonton | 8140 (Mixes ventilation air prior to cooling or heating) | HVAC Return | 8126X | 8144NC |
¹ Primary Aprilaire recommended supply ventilation solution for optimal performance and building code adherence. ² HVAC application considerations based upon moist versus dry air, and proper mixing into the ductwork.
Ventilation Systems Specifications
Model | Unit Size (W x H x D) | Shipping Weight (lbs.) | Airflow (CFM) @ 0.2 in. w.c. | Description |
8192 (Fresh Air Ventilator with Dehumidification) | 12 1/2" x 14 1/2" x 27 1/2" | 84.00 | 230 | Features integrated ventilation control. Draws fresh air, dehumidifies if incoming air is above set RH. 95 ppd* capacity. |
8140 / 8140NC (Fresh Air Ventilators) | 14 2/5" x 11 3/5" x 27 4/5" | 30.50 | 225 | Delivers fresh air into return or supply duct. 8140 includes 8120X controller; 8140NC requires separate control. |
8142 / 8142NC (Fresh Air Ventilators) | 13 1/5" x 6 7/10" x 11 9/10" | 12.36 | 210 | Delivers fresh air into return or supply duct. 8142 includes 8120X controller; 8142NC requires separate control. |
8144NC (Fresh Air Ventilator) | 10 1/4" x 18 1/8" x 10 1/4" | 20.50 | 130 | Provides continuous low-volume ventilation for smaller homes. Optional 8120X controller for code or comfort operation. |
8120X (Ventilation Controller) | 4 11/100" x 3 3/5" x 15 9/100" | 0.50 | - | Engages fan/damper for fresh air delivery. Programmable for code requirements or set RH/temperature limits. |
8126X (Ventilation System) | 10 8/25" x 10 3/4" x 6" | 6.50 | - | Includes powered damper and controller. Mounts on return side; uses negative pressure to draw fresh air. |
6508KV (Kitchen Ventilation Kit) | 8" x 10 3/4" x 12 1/3" | 6.00 | 185 | Provides make-up air for high-CFM range hoods to prevent home depressurization. |
6510KV (Kitchen Ventilation Kit) | 10" x 10 3/4" x 14 1/3" | 6.70 | 390 | Provides make-up air for high-CFM range hoods to prevent home depressurization. |
8100 (Fresh Air Exchanger - ERV) | 37 3/8" x 20 23/40" x 12 3/4" | 87.00 | 130 | Exchanges energy (heating/cooling) and moisture between incoming fresh air and outgoing stale air. Requires separate controller. |
Accessories
Aprilaire offers various accessories to complement their IAQ systems, including sensors, adapters, and expansion modules.
Model | Product Description | Unit Size | Type of Wire | Compatible Models |
8051 | Flush Mount Sensor | Disk: 1 1/2" dia. | 18-24 gauge 2 conductor wire | 8600, 8620, 8620W, 8910, 8910W, 8920W, 8800, 8820, 8830, 8840 |
8052 | Outdoor/Duct Sensor | Probe: 1/4" dia. x 1 3/4" L; Bracket: 3/4" x 3/4" | 18-24 gauge 2 conductor wire | 8600, 8620, 8620W, 8910, 8910W, 8920W, 8800, 8820, 8830, 8840 |
8053 | Surface Mount Sensor | W: 3 3/4" H: 2 7/8" D: 7/8" | 18-24 gauge 2 conductor wire | 8600, 8620, 8620W, 8910, 8910W, 8920W, 8800, 8820, 8830, 8840 |
8022 | 3-Wire to 4-Wire Adapter | W: 2 7/8" H: 1 3/4" D: 1 14/75" | 18-22 gauge stranded or solid thermostat wire | All thermostats |
8028 | Damper Power Distribution Panel | W: 10 1/2" H: 5" D: 1 7/10" | - | All zone control panels |
6401 | Expansion Panel | W: 10 1/2" H: 5" D: 1 7/10" | - | 6404 (With LCD screen) |
8081 | Temperature Support Module | W: 3 1/2" H: 2 1/2" D: 7/8" | Cat 6 or greater | 8800, 8820, 8830, 8840 |
8082 | Temperature and RH Support Module | W: 3 1/2" H: 2 1/2" D: 7/8" | Cat 6 or greater | 8800, 8820, 8830, 8840 |
8083 | Flush Temperature and RH Support Module | Disk: 1 1/2" dia. Cylinder Hole: 1" off wall, 1/4" air gap | Cat 6 or greater | 8800, 8820, 8830, 8840 |