Overview
This guide provides step-by-step instructions for installing the SALTO DBolt Touch smart lock. It covers the necessary parts, tools, and the complete installation process, including battery replacement and emergency opening.
Parts and Tools Required
Dimensions:
- Height: 6-5/16" (160 mm)
- Widths range from 1-1/4" (31.5 mm) to 2-13/16" (72 mm)
- Depth: 2-1/16" (52.5 mm)
Components:
- Gasket
- Inside Fixing Plate
- Fixing Screw
- Mounting Screws
- Inside Assembly
- Outside Assembly
- Door Detector
Tools & Hardware:
- Batteries: AA - LR6 (SP01077-10)
- Screws: TORX 10 (x3), TORX 10 (x1), TORX 20 (x4), PH 2 (x2), PH 2 (x4)
- Required Tools: TORX 10, TORX 20, PH 2 screwdrivers.
Door Detector Variants:
- WOOD DOORS: RFDTCTW30W01
- STEEL DOORS: RFDTCTS30W01
Installation Steps
Step 1: Prepare the Door and Frame
Mount the lock mechanism onto the door. Ensure correct orientation for the frame (RH or LH).
Step 2: Attach Inside Fixing Plate
Secure the inside fixing plate to the door using the provided screws.
Step 3: Assemble Lock Mechanism
Connect the various parts of the lock mechanism as shown in diagrams 3a, 3b, and 3c.
Step 4: Select Correct Screws for Door Thickness
Refer to the table for appropriate screw lengths based on door thickness (ranging from 1-3/8" to 3-11/32").
Door Thickness Screw Length 1-3/8" - 1-9/16" (35 - 40 mm) 1-3/4" (45 mm) 1-9/16" - 1-3/4" (40 - 45 mm) 1-31/32" (50 mm) 1-3/4" - 1-31/32" (45 - 50 mm) 2-3/16" (55 mm) 1-31/32" - 2-3/16" (50 - 55 mm) 2-3/8" (60 mm) 2-3/16" - 2-3/8" (55 - 60 mm) 2-9/16" (65 mm) 2-3/8" - 2-9/16" (60 - 65 mm) 2-3/4" (70 mm) 2-9/16" - 2-3/4" (65 - 70 mm) 2-15/16" (75 mm) 2-3/4" - 2-15/16" (70 - 75 mm) 3-5/32" (80 mm) 2-15/16" - 3-5/32" (75 - 80 mm) 3-11/32" (85 mm) 3-5/32" - 3-11/32" (80 - 85 mm) 3-9/16" (90 mm) Step 5: Insert Batteries and Connect Cables
Insert the AA batteries into the designated compartment. Connect any necessary cables, including the door detector cable if applicable.
Step 6: Attach Inside Assembly
Align and attach the inside assembly to the door, ensuring all connections are properly seated.
Step 7: Secure Inside Assembly
Fasten the inside assembly using the provided mounting screws.
Step 8: Final Lock Assembly
Complete the assembly of the lock mechanism.
Step 9: Handle Door Detector Cable (If Applicable)
For models with a door detector, disconnect the cable first (9a, 9b) and then reconnect it (9c) during assembly.
Step 10: Connect Battery
Ensure the battery is connected.
Step 11: Attach Outside Assembly
Connect and attach the outside assembly to the lock mechanism.
Step 12: Attach Inside Assembly
Align and attach the inside assembly (12a, 12b).
Step 13: Secure Inside Assembly
Fasten the inside assembly.
Step 14: Test Lock Functionality
Perform a test of the lock's operation (14a, 14b).
Step 15: IMPORTANT - Programming
⚠️ DO NOT CLOSE THE DOOR. PROGRAM THE LOCK FIRST!
(Multilingual: NE FERMEZ PAS LA PORTE. PROGRAMMEZ LA SERRURE AVANT! / ¡NO CIERRE LA PUERTA. PROGRAME ANTES LA CERRADURA!)
Step 16: Refer to Keypad User Guide
For programming and user operations, consult the Keypad User Guide.
Battery Replacement and Emergency Opening
Battery Replacement
To replace batteries (a, b): Open the cover, remove old batteries, and insert new AA - LR6 batteries. The process should take a maximum of 40 seconds (MAX.40") to retain settings.
Emergency Opening
In case of low battery or lockout, emergency opening can be performed (i). Connect a power bank to the Type C connector port on the lock to provide temporary power, allowing access.