JA-110B Acoustic Glass Break Detector for Bus Systems
Brand: JABLOTRON
Introduction
This document was machine-translated from the original English. For any ambiguities or doubts, please refer to the original version of the document. For errors or further questions, please contact Technical Support (contact details can be found at the end of this document).
The JA-110B is a component of the JABLOTRON system. It is used for detecting glass breaks in buildings. It reacts to air pressure changes that accompany the characteristic sound of glass breaking. The detector reacts impulsively (only reports its triggering). The installation of the detector should be carried out by a trained technician with a valid certificate from an authorized dealer.
Installation
⚠️ Always switch off the power when connecting the module to the system bus.
- Open the detector cover by pressing the latch (1) with a flat screwdriver.
- Remove the PCB – it is held by a latch (5).
- Insert the bus cable and screw the rear cover part to the wall.
- Reinsert the PCB and connect the bus cable to the bus terminals (6).
- Adjust the sensitivity of the acoustic sensor using the trimmer (10).
- Close the detector cover.
Figure 1: Product Parts Description
- 1 - Cover latch
- 2 - Hole for acoustic sensor
- 3 - Light guide
- 4 - Acoustic sensor
- 5 - PCB latch
- 6 - Bus terminals
- 7 - Serial number
- 8 - Red LED activation indicator
- 9 - Yellow LED fault indicator
- 10 - Trimmer for sensitivity adjustment
- 11 - Tamper contact
System Enrollment
Use the recommended software or application depending on the control panel type (see the control panel manual).
Technical Data
Feature | Value |
---|---|
Power | From the central bus 12 V (9...15 V) |
Quiescent current consumption | 5 mA |
Maximum current consumption | 5 mA |
Recommended installation height | 2.5 m above the floor |
Detection distance | up to 9 m |
Minimum window size | 0.6 x 0.6 m |
Stabilization time after power-on | max. 60 s |
Dimensions | 40 x 100 x 22 mm |
Weight | 50 g |
Classification | Security Grade II / Environmental Class II (according to EN 50131-1) |
Environment | Indoor general use |
Operating temperature range | -10 °C to +40 °C |
Average operating humidity | 75% relative humidity, non-condensing |
Certification body | Trezor Test sro (No. 3025), Kiwa Nedeland bv |
In compliance with | EN 50131-1, -2-7-1, T 031, EN 50130-4, EN 55032, EN IEC 63000 |
Recommended screw | 2x ⌀ 3.5 x 40 mm (countersunk head) |
The product bears the CE and UKCA marks, indicating compliance with relevant EU and UK regulations. JABLOTRON a.s. hereby declares that the JA-110B, when used as intended, complies with the relevant harmonisation legislative provisions of the European Union: Directives No. 2014/30/EU, 2011/65/EU. The original Declaration of Conformity can be found at www.jablotron.com in the Downloads section.
Disposal Information
Note: By properly disposing of this product, you save valuable resources and avoid potential negative impacts on health and the environment that may arise from improper disposal. Please return the product to your dealer or contact your local authority for more information on the nearest collection point.
For an electronic version of this document (available in other languages) or a version for mounting in JA-100, scan the attached QR code.
Manufacturer Information
JABLOTRON a.s.
Pod Skalkou 4567/33
46601 Jablonec nad Nisou
Czech Republic
Tel: +420 483 559 911
Internet: www.jablotron.com