How to Use the P5 Smart Air Pump
User Guide
Version 1.0
Contents
- Product Information
- Product Packaging
- Function Presentation
- Basic Operation
- Charging Method
- Air Pressure Unit Switching
- LED Light
- Preset Air Pressure
- Checking Air Pressure
- Resetting Pressure
- Application Scene Switching
- Inflation Pressure Check
- Connecting the Air Hose to the Air Valve
- Mobile Power
- Common Item Air Pressure Values
- Attention
- High Temperature Safety Precautions
- Troubleshooting
Product Information
Product Model: Smart Air Pump P5
Input/Output: USB-C Input/USB-A Output: 5V/2A
Net Weight: 500G
Product Size: 162.5*68*38MM
Pressure Range: 2-150 PSI / 0.1—10.3 BAR
Working Temperature: -10—45°C
Battery Capacity: 3.7V/5000mAh (18.5Wh/7.4V)
Product Packaging
- Smart Air Pump
- Packaging
- Storage Bag
- USB-C Charging Cable
- Presta Valve Adapter
- Ball Needle
- User Guide
- American Style Quick Connect Air Hose
Diagrams show the Smart Air Pump, its packaging, user guide, and storage bag.
Function Presentation
Diagram of the air pump interface:
- Air Hose Interface: Connection point for the air hose.
- LED Light: Integrated LED light.
- USB-C Input Port: For charging the pump.
- USB-A Output Port: For charging external devices.
Display screen details:
- Real-time Air Pressure Display: Shows the current air pressure.
- Battery Indicator: Displays the remaining battery level.
- Preset Pressure: Shows the target inflation pressure.
- Pressure Units: Displays current unit (PSI, BAR, KPA, Kg/cm²).
Button functions:
- Power Button: Turns the device on/off and starts/stops inflation.
- Preset + Button: Increases the preset pressure value.
- Preset - Button: Decreases the preset pressure value.
- Mode/LED Light Button: Switches between modes and controls the LED light.
- Air Pressure Unit Switch Button: Cycles through pressure units (e.g., PSI, BAR).
Basic Operation
Power On/Off
Press and hold the power button for 3 seconds to turn the air pump on or off.
Diagram: Shows pressing and holding the power button for 3 seconds to turn on the device.
Pumping Method
Once powered on, briefly press the power button to start inflating. The pump will automatically stop when the preset air pressure is reached.
Diagram: Shows briefly pressing the power button to start inflating.
Battery Indicator
Different battery indicator colors indicate different battery levels:
- Green: 65%~100%
- Yellow: 25% ~ 65%
- Red: 10%~25%
- Flashing Red: Below 10% (Low battery alert, please charge.)
Charging Method
Use a USB-C cable and a 5V/2A power adapter (sold separately) to charge the air pump.
Charging Indicator:
- Flashing green light: Charging
- Solid green light: Fully charged
Note: The air pump cannot be used while charging.
Air Pressure Unit Switching
Briefly press the [Unit] button to switch the displayed air pressure unit.
Conversion formula: 1 BAR = 14.5 PSI.
LED Light
Press and hold the [Light] button to turn on the LED light. Press and hold again to turn it off.
Preset Air Pressure
Briefly press the [+] or [-] buttons to adjust the preset air pressure by 0.5 PSI per press.
Press and hold the [+] or [-] buttons to quickly set the desired preset air pressure.
Note: The device automatically saves the scene mode and preset pressure value. The next time you use it, the preset pressure will be automatically applied.
Checking Air Pressure
When the air pump is in standby mode and the air hose is connected to the inflatable object, the upper part of the pump's display will show the currently measured air pressure.
Diagram: Shows measured air pressure (e.g., 16.5) and preset air pressure (e.g., 38.0).
Resetting Pressure
If the measured pressure is not 0.0 when the air hose is not connected to an inflatable object after powering on, press and hold the [+] and [-] buttons simultaneously for 2 seconds. All screen lights will illuminate, and the display will return to normal.
Diagram: Shows pressing and holding the [+] and [-] buttons for 2 seconds to reset.
Note: Resetting the air pressure to default zero can improve barometric accuracy when the measured barometric value is not zero due to altitude or sensor differences. Calibration is not recommended at high temperatures.
Application Scene Switching
Briefly press the [Unit] button to select from 5 inflatable scene modes:
Scene Mode | Default Preset Value | Adjustable Range |
---|---|---|
Ballons (Balls) | 8 PSI | 2-15 PSI |
Vélo (Bicycle) | 38 PSI | 2-150 PSI |
Moto (Motorcycle) | 2.7 BAR | 0.1-3.7 BAR |
Véhicule à Moteur (Motor Vehicle) | 2.4 BAR | 0.1-4.4 BAR |
Personnaliser (Custom) | 100 PSI | 2-150 PSI |
Inflation Pressure Check
For safety, check the required inflation pressure for the item being inflated according to its instruction manual before inflating to avoid injuries from over-inflation.
Tire Pressure Recommendations
- Car Tires: The pressure range is marked on the tire sidewall. Inflation pressure depends on the load weight. Refer to the vehicle's manual for detailed recommendations.
- Motorcycle Tires: The pressure range is marked on the tire sidewall. Inflation pressure depends on the load weight. Refer to the vehicle's manual for detailed recommendations.
- Bicycle Tires: The pressure range is marked on the tire sidewall. Inflation pressure depends on the load weight. Refer to the bicycle's manual for detailed recommendations.
- Balls: The inflation pressure for footballs, basketballs, volleyballs, and other balls is marked around the inflation hole. Inflation pressure depends on the load weight. Refer to the ball's manual for detailed recommendations.
Connecting the Air Hose to the Air Valve
Schrader Valves
MTBs, electric bikes, and motorcycles are typically equipped with Schrader valves. To inflate: Connect the Schrader valve to the American-style quick-connect air hose for inflation.
Diagram: Shows an American-style quick-connect hose connected to a Schrader valve.
Presta Valves
For inflating road bikes and some MTBs, a Presta valve adapter is required.
- Connect the Presta valve adapter to the high-pressure air hose's Schrader valve.
- Unscrew the Presta valve cap.
- Connect the Presta valve to the adapter for inflation.
Diagram: Shows a Presta valve adapter connected to the air hose, ready to attach to a Presta valve.
Ball Valves
Ball valves are needed to inflate balls like basketballs and footballs. Inflation: After connecting the ball valve to the Schrader valve on the air hose, insert the ball valve into the ball's inflation hole to inflate.
Diagram: Shows a ball valve connected to the air hose, inserted into a ball's inflation hole.
Mobile Power
The Lexin P5 smart air pump has a 5000 mAh battery. The USB-A 5V/2A output port can be used to charge electronic devices such as mobile phones.
Note: Inflation and charging cannot be performed simultaneously.
Diagram: Illustrates the air pump being used to charge a mobile phone via its USB-A output port.
Common Item Air Pressure Values
Product Category | Product Type | Pressure Range |
---|---|---|
Bicycle | Road Bike | 100~120 PSI |
Bicycle | Balance Bike | 40~60 PSI |
Bicycle | Wheelchair | 30~45 PSI |
Motorcycle | Motorcycle/Electric Motorcycle | 1.8-3.0 BAR |
Motor Vehicle | Cars | 2.2~2.8 BAR |
Ball | Toy Ball for Children | 3~6 PSI |
Ball | Basketball | 7~9 PSI |
Ball | Football | 10~12 PSI |
Ball | Volleyball | 4~6 PSI |
Ball | Rugby Ball | 10~14 PSI |
Attention
- Do not leave unattended during inflation.
- Keep the air pump away from flammable and explosive materials.
- Avoid sand ingress.
- Do not place the product in extremely cold, hot, or humid environments.
- This product contains a built-in lithium battery; do not dispose of it in fire or carelessly.
- Keep this product out of reach of children.
High Temperature Safety Precautions
When the air hose is disconnected, the hose and its connector can generate high temperatures after prolonged use. Avoid touching them with bare hands for extended periods.
Diagram: Illustration indicating a high temperature warning near the hose connection.
Troubleshooting
Problem | Troubleshooting Method |
---|---|
Slow Inflation |
|
Cannot Inflate |
|
Cannot Adjust Preset Pressure | Ensure the pump is in the correct inflation mode. Select the custom mode to adjust the preset value within the 3 to 150 Psi range. |
Inflates Correctly but Pressure Reads Zero |
|
Auto-stops After Connecting Valve | The pump will automatically shut off after 3 minutes. Press and hold the power button to turn it back on. |
Air Leak at Hose Connection | Tighten the air hose. |
Inconsistent Battery Indicator Color | The lithium battery experiences a voltage drop during discharge, leading to inconsistent indicator colors between charging and standby states. This is not a defect. |
Power Indicator Does Not Turn On After Charging | Replace with safe and compliant charging cables and adapters. |