WAC Lighting Endurance Brick Light Installation Instructions
Models: WL-5105, WL-5205
Important Safety Information
Warnings
IMPORTANT: NEVER attempt to do any work without shutting off the electricity. Read all instructions before installing. This system is intended for installation by a qualified electrician in accordance with the National Electrical Code and local regulations. Place the wall switch in the "OFF" position. Go to the main fuse box, or circuit breaker. Unscrew the fuse(s) or switch "OFF" the circuit breaker switch(es) that control the power to the space you are working on.
French Summary: Coupez l'électricité avant toute manipulation. Lisez toutes les instructions. Installation par un électricien qualifié selon les codes nationaux et locaux. Mettez l'interrupteur mural sur "OFF". Coupez le fusible principal ou le disjoncteur.
Spanish Summary: Nunca trabaje sin desconectar la electricidad. Lea todas las instrucciones. Instalación por electricista calificado según códigos. Ponga el interruptor de pared en "OFF". Corte el fusible principal o el disyuntor.
Caution
All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction may invalidate the ETL/cETL listing of this fixture.
French Summary: Utilisez toutes les pièces comme indiqué. Ne substituez pas, n'omettez pas ou n'utilisez pas de pièces usées ou cassées. Le non-respect peut annuler la certification ETL/cETL.
Spanish Summary: Use todas las piezas según las indicaciones. No sustituya, omita ni use piezas desgastadas o rotas. El incumplimiento puede invalidar la certificación ETL/cETL.
Product Overview
This document provides installation instructions for the WAC Lighting Endurance Brick Light.
Overall Dimensions
The fixture has a face size of 4 inches by 4 inches and a depth of 9.5 inches.
Hardware Included
- A1 Bracket Mounting Screw: Qty: 4 pcs
- B1 L-Bracket: Qty: 4 pcs
- B2 Masonry Bracket: Qty: 4 pcs
- C1 Wire Nuts: Qty: 3 pcs + 1 Extra
Installation Instructions
For Brick Wall Installation (While the wall is being constructed)
- Remove the cover plate and light engine from the brick light housing. Store in a clean, safe location.
- Note the proper orientation of the brick light housing. Attach masonry brackets (B2) to the bottom of the housing using mounting screws (A1).
- Determine the desired hole in the housing for wiring. Unscrew the 1/2 NPT plug at that location. Tighten remaining conduit caps with thread seal tape (by others).
- Lead power supply wire through the chosen hole and secure the cable/conduit using an appropriate connector.
- Embed the attached masonry brackets into mortar and place the brick light housing into the wall in place of a standard brick.
- Continue building the wall, attaching the upper masonry brackets before installing the layer above the brick light. Minimize force applied to prevent damaging the housing and cracking the mortar.
- Allow the mortar in the wall to cure.
- Ensure there is no dust or debris within the housing or on the surface of the gasket.
- Connect the wires of the light engine to the power supply wires using provided wire nuts (C1): Connect fixture black wire to house black wire (Hot), fixture white wire to house white wire (Neutral), and fixture ground wire to house ground wire (Green or Bare Copper).
- Using the two handles attached on the light engine, snap the light engine into the clips located within the housing.
- Place the cover plate over the housing. Align and tighten firmly for a watertight seal.
For Wood Wall/Stair Installation (Access to back required)
- Remove the cover plate and light engine from the brick light housing.
- Note the proper orientation of the brick light housing.
- Cut an opening measuring 3 3/4 inches by 8 inches at the desired location. Insert the brick light housing until the base of the lip is flush with the mounting surface.
- Determine the desired hole in the housing for wiring. Unscrew the 1/2 NPT plug at that location. Tighten remaining conduit caps with thread seal tape (by others).
- Lead power supply wire through the chosen hole and secure the cable/conduit using an appropriate connector.
- From the back of the housing, attach provided L-shaped brackets (B1) using provided mounting screws (A1) to clamp the wooden surface.
- For additional mounting security, use wood screws (by others) to fasten the L-shaped brackets to the structure.
- Ensure there is no dust or debris within the housing or on the surface of the gasket.
- Connect the wires of the light engine to the power supply wires using provided wire nuts (C1): Connect fixture black wire to house black wire (Hot), fixture white wire to house white wire (Neutral), and fixture ground wire to house ground wire (Green or Bare Copper).
- Using the two handles attached on the light engine, snap the light engine into the clips located within the housing.
- Place the cover plate over the housing. Align and tighten firmly for a watertight seal.
Contact Information
Website: waclighting.com
Phone: (800) 526.2588
Fax: (800) 526.2585
Headquarters/Eastern Distribution Center: 44 Harbor Park Drive, Port Washington, NY 11050
Central Distribution Center: 1600 Distribution Ct, Lithia Springs, GA 30122