Toshiba Package Air Conditioner Specifications
Model: GBSB22414MUB
Indoor Unit: AID-GP1121BH x2
Outdoor Unit: ROA-RP2244HS
Branching Pipe: RBC-TWP102
Type: Ceiling-Embedded Inverter Heat Pump (Air Cooled)
Cooling Performance
Item | Unit | Standard Cooling Capacity | Nominal Cooling Energy Efficiency Ratio | Intermediate Cooling Capacity | Minimum Cooling Capacity |
---|---|---|---|---|---|
Capacity | kW | 20.0 (5.3~22.4) | 2.80 / 2.80 | 9.0 | 5.6 |
Sensible Heat Ratio | - | 0.80 | - | - | - |
Heating Performance
Item | Unit | Standard Heating Capacity | Nominal Heating Energy Efficiency Ratio | Intermediate Heating Capacity | Minimum Heating Capacity | Maximum Heating Low Temperature Capacity |
---|---|---|---|---|---|---|
Capacity | kW | 22.4 (4.6~28.0) | 3.45 / 3.45 | 10.1 | 5.7 | 20.8 |
Energy Efficiency
Item | Unit | APF2015 (JIS B 8616:2015) | APF (JIS B 8616:2006) | Cooling/Heating Average Energy Efficiency |
---|---|---|---|---|
Annual Energy Consumption Efficiency | APF | 5.0 / 5.0 | 4.5 / 4.5 | 3.13 / 3.13 |
Electrical Characteristics
Item | Unit | Power Supply | Compressor Motor Rated Output | Fan Motor Rated Output | Power Consumption (Cooling) | Power Consumption (Heating) | Operating Current (Cooling) | Operating Current (Heating) | Starting Current |
---|---|---|---|---|---|---|---|---|---|
Standard Cooling | kW | 7.14 / 7.14 | - | - | - | - | - | - | - |
Intermediate Cooling | kW | 2.05 / 2.05 | - | - | - | - | - | - | - |
Intermediate Cooling (Mid-Temp) | kW | 1.75 / 1.75 | - | - | - | - | - | - | - |
Minimum Cooling (Mid-Temp) | kW | 0.760 / 0.760 | - | - | - | - | - | - | - |
Standard Heating | kW | 6.49 / 6.49 | - | - | - | - | - | - | - |
Intermediate Heating | kW | 1.98 / 1.98 | - | - | - | - | - | - | - |
Minimum Heating | kW | 0.990 / 0.990 | - | - | - | - | - | - | - |
Maximum Heating (Low Temp) | kW | 8.60 / 8.60 | - | - | - | - | - | - | - |
Operating Current | A | 21.9 / 21.9 (Cooling) | 19.9 / 19.9 (Heating) | - | - | - | - | - | - |
Maximum Current | A | 29.3 / 29.3 | - | - | - | - | - | - | - |
Power Factor | % | 94 / 94 (Cooling) | 94 / 94 (Heating) | - | - | - | - | - | - |
General Specifications
Item | Unit | Description |
---|---|---|
Power Supply | - | 3-Phase 200V 50/60Hz |
Compressor Type | - | Fully Enclosed |
Refrigerant Control | - | Electronic Expansion Valve |
Fan Type | - | Propeller Fan |
High Pressure Switch Setting | MPa | Activation: 4.15, Reset: 3.20 |
Low Pressure Switch Setting | MPa | - |
Protective Devices | - | Discharge Temperature Sensor, Overcurrent Sensor, Compressor Thermistor |
Case Heater | W | - |
Noise Level (Sound Power Level) | dB | Cooling: 76, Heating: 77 |
Noise Level (Sound Pressure Level) | dB(A) | Cooling: 58, Heating: 61 |
IP Code | - | IPX4 |
Rated Refrigeration Ton | - | 3.92 |
Design Pressure (High Pressure Side) | MPa | 4.15 |
Design Pressure (Low Pressure Side) | MPa | 2.21 |
Refrigerant & Shipping Charge | kg | R32: 5.20 |
Maximum Piping Length (No Refrigerant Addition) | m | 30 |
Refrigerant Addition Amount | g/m | Main Piping: 40, Branch Piping: 40 |
Refrigerant Piping (Gas Side) | mm | 25.4 |
Refrigerant Piping (Liquid Side) | mm | 9.5 |
Maximum Piping Length (Branch Piping) | m | 20 |
Maximum Length Difference (Branch Piping) | m | 10 |
Leakage Circuit Breaker | - | 40A, 30mA, 0.1sec or less |
Local Switch Capacity | A | 60 |
Fuse Capacity | A | 40 |
Circuit Breaker Capacity | A | 40 |
Air Filter | - | Included with Indoor Unit |
Operation Control | - | Remote Control Switch (Sold Separately) |
Power Wiring Length (Max) | m | 75m or less (for outdoor-indoor unit connection) |
Drain Pipe Diameter (Nominal) | - | 25 (PVC Pipe) |
Indoor Unit Noise Level (Sound Power Level) | dB(A) | 63/61/59/57/55 (High/Mid-High/Mid/Mid-Low/Low) |
Indoor Unit Noise Level (Sound Pressure Level) | dB(A) | 48/46/44/42/40 (High/Mid-High/Mid/Mid-Low/Low) |
Power Wiring | - | Single wire 1.6mm, Stranded wire 22.0mm², Stranded wire 38.0mm² |
Signal Wiring | - | Single wire 2.0mm, Stranded wire 3.5mm², Stranded wire 5.5mm², Stranded wire 8.0mm², Stranded wire 14.0mm² |
Remote Control Cord | - | Single wire 1.6mm x 2 (for power), Stranded wire 0.5mm² x 2 (for signal). Connect to Indoor Unit A only. (Up to 500m) VCTF0.5-2.0mm² etc. |
Remote Control | - | RBC-AMSU52 (Sold Separately) |
Notes
- (Note 1) Cooling and heating performance and electrical characteristics are based on temperature conditions and standard piping (piping equivalent length 7.5m (5m for P40~P63 models), 0m head) according to JIS B 8616:2015. Values in < > indicate the capacity range.
- (Note 2) Power supply voltage should not deviate by more than ±10%.
- (Note 3) When two indoor units are used for the same system, the displayed values are per indoor unit.
- (Note 4) Remote control switches are sold separately. Refer to the "Remote Control Outline Drawing" for remote control cord wiring length.
- (Note 5) The Annual Energy Consumption Efficiency (APF) according to the "Criteria for Manufacturers and Businesses for Improving Air Conditioner Performance" (commonly known as the Energy Saving Act standards) by the Ministry of Economy, Trade and Industry Notification No. 213 is based on "APF (JIS B 8616: 2006)".
- (Note 6) Rated airflow is for "High" fan speed.
- (Note 7) When changing the external static pressure, it is necessary to change the setting on-site.
- (Note 8) Rated noise (sound power level) is based on JIS B 8616:2015.
- (Note 9) Operating noise (sound pressure level) is based on JIS B 8616:2006.
- (Note 10) If the leakage circuit breaker is for ground fault protection only, install a local switch with a fuse or a circuit breaker. Use a harmonic-aware leakage circuit breaker.
- (Note 11) Depending on the separately sold accessories, the external dimensions, appearance, weight, and performance characteristics of the air conditioner may change.
Manufacturer: Nihon Carrier Corporation
Document Number: T2525063
Model Code: 25601