Toshiba Package Air Conditioner GBSF28014MUB Specifications
This document outlines the specifications for the Toshiba GBSF28014MUB package air conditioner, a ceiling-embedded inverter heat pump type with double twin configuration.
General Information
Item | Details |
---|---|
Set Name | GBSF28014MUB |
Indoor Unit Model | AID-GP711BH |
Outdoor Unit Model | ROA-RP2804HS |
Branch Duct 1 | RBC-TWP102 |
Branch Duct 2 | RBC-TWP50 |
Type | Ceiling-Embedded Inverter Double Twin |
Compliance | Green Purchase Law Compliant |
Cooling Performance
Item | Unit | Standard | Intermediate Cooling | Minimum Cooling |
---|---|---|---|---|
Standard Cooling Capacity | kW | 25.0 (5.3~28.0) | 11.3 | 6.3 |
Sensible Heat Ratio | - | 0.68 | - | - |
Standard Cooling Energy Efficiency | kW/(kW) | 2.38/2.38 | - | - |
Heating Performance
Item | Unit | Standard | Intermediate Heating | Minimum Heating |
---|---|---|---|---|
Standard Heating Capacity | kW | 28.0 (4.6~31.5) | 12.6 | 7.0 |
Standard Heating Energy Efficiency | kW/(kW) | 3.31/3.31 | - | - |
Maximum Heating Low Temperature Capacity | kW | 22.2 | - | - |
Energy Efficiency
Item | Unit | Value |
---|---|---|
Annual Performance Factor (APF 2015) | APF | 4.6/4.6 |
Annual Performance Factor (APF 2006) | APF | 4.3/4.3 |
Cooling/Heating Average Energy Efficiency | - | 2.85/2.85 |
Electrical Characteristics
Item | Unit | Cooling | Heating |
---|---|---|---|
Power Supply | - | 3-Phase 200V 50/60Hz | 3-Phase 200V 50/60Hz |
Fan Motor Rated Output | kW | 0.200+0.200 | 0.200+0.200 |
Compressor Motor Rated Output | kW | 7.16 | 7.16 |
Rated Cooling Power Consumption | kW | 10.5 / 10.5 | - |
Intermediate Cooling Power Consumption | kW | 2.57/2.57 | - |
Intermediate Heating Power Consumption | kW | - | 2.51/2.51 |
Minimum Cooling Power Consumption | kW | 0.859/0.859 | - |
Rated Heating Power Consumption | kW | - | 8.46/8.46 |
Minimum Heating Power Consumption | kW | - | 1.47/1.47 |
Operating Current | A | 31.9/31.9 | 25.7/25.7 |
Starting Current | A | 39.1/39.1 | - |
Power Factor | % | 95/95 | 95/95 |
Fan and Airflow
Item | Unit | Value |
---|---|---|
Fan Type | - | Propeller Fan |
Standard Airflow | m³/min | 20.0 / 18.3 / 16.8 / 15.7 / 13.5 (Rapid/Strong+/Strong/Weak+/Weak) |
Motor Rated Output | kW | 0.150 |
External Static Pressure Setting Range | Pa | 20-30-40-50-65-80-100 |
Airflow Limit (Lower) | m³/min | 11.3 |
Airflow Limit (Upper) | m³/min | 24.0 |
Dimensions and Weight
Item | Unit | Outdoor Unit | Indoor Unit |
---|---|---|---|
Dimensions (H x W x D) | mm | 1010 x 1550 x 370 | 275 x 1000 x 925 |
Weight | kg | 181.5 | 34 |
Heat Exchanger | - | Finned Tube | Finned Tube |
Fan | - | Propeller Fan | Sirocco Fan |
Refrigerant and Piping
Item | Unit | Details |
---|---|---|
Refrigerant Type | - | R32 |
Factory Refrigerant Charge | kg | 5.20 |
Maximum Piping Length (No Charge) | m | 30 |
Additional Refrigerant Charge | g/m | Main Piping: 40, Branch Piping: 40 |
Piping Size (Gas/Liquid) | mm | Outdoor to Branch 1: $25.4 / $12.7, Branch 1 to Branch 2: $15.9 / $9.5, Branch 2 to Indoor: $15.9 / $9.5 |
Maximum Piping Length | m | 100 |
Maximum Height Difference | m | 30 (Outdoor Unit Above), 30 (Outdoor Unit Below) |
Maximum Branch Piping Length | m | 20 |
Maximum Branch Piping Length Difference | m | 6 |
Noise Levels
Item | Unit | Cooling | Heating |
---|---|---|---|
Sound Power Level | dB(A) | 60/58/56/53/51 (Rapid/Strong+/Strong/Weak+/Weak) | - |
Sound Pressure Level | dB(A) | 45/43/41/38/36 (Rapid/Strong+/Strong/Weak+/Weak) | 31/31 |
Safety and Controls
Item | Details | |
---|---|---|
High Pressure Switch | Setting: 4.15 MPa, Reset: 3.20 MPa | |
Low Pressure Switch | Cut-in: 0.20 MPa | |
Protective Devices | Discharge Temperature Sensor, Overcurrent Sensor, Compressor Thermistor | |
Case Heater | - | Not applicable |
Circuit Breaker | 50A, 30mA, 0.1 sec or less (for ground fault protection) | |
Fuse | 60A | |
Air Filter | Included with Indoor Unit | |
Operation Adjustment Device | Remote control switch (sold separately) | |
Drain Pipe Diameter | 25 (PVC Pipe) |
Wiring and Installation
Item | Details |
---|---|
Power Wiring | Indoor Unit to Outdoor Unit: Single wire 1.6mm x 3, 120m max. Branch Piping: Single wire 1.6mm x 2, 75m max. |
Inter-unit Wiring | Indoor A to Indoor B: Stranded wire 3.5mm² x 2. Indoor to Indoor C: Stranded wire 3.5mm² x 1. Indoor C to Indoor D: Stranded wire 3.5mm² x 1. |
Remote Control Wiring | (Connected only to Indoor Unit A) VCTF 0.5-2.0mm² or similar. (Signal wire: Stranded wire 0.5mm² x 2, up to 500m) |
Optional Remote Controller | RBC-AMSU52 |
Notes
- (Note 1) Cooling and heating performance, and electrical characteristics are based on JIS B 8616:2015 temperature conditions and standard piping (piping equivalent length 7.5m (5m for P40~P63 models), 0m head difference). Values in < > indicate the capacity range.
- (Note 2) Power voltage should not exceed ±10% fluctuation.
- (Note 3) When using four indoor units, the values shown are per indoor unit.
- (Note 4) Remote control switches are sold separately. Refer to the 'Remote Controller Outline Drawing' for remote control wiring length.
- (Note 5) The Annual Performance Factor (APF) according to the "Judgment Standards for Manufacturers, etc. for Improving Air Conditioner Performance" (commonly known as the Energy Saving Law Standards) notified by the Ministry of Economy, Trade and Industry, Notification No. 213, is based on "APF (JIS B 8616:2006)".
- (Note 6) Standard airflow is for 'Rapid' setting.
- (Note 7) External static pressure must be adjusted on-site if changed.
- (Note 8) Rated noise (sound power level) is based on JIS B 8616:2015.
- (Note 9) Operating noise (sound pressure level) is based on JIS B 8616:2006.
- (Note 10) If the ground fault interrupter is for ground fault protection only, install a local disconnect switch with a fuse, or a circuit breaker. Use a harmonic-compatible ground fault interrupter.
- (Note 11) Some optional parts may alter the external dimensions, appearance, weight, operating noise, or performance characteristics of the air conditioner.
Manufacturer: Nihon Carrier Corporation
Document Number: T2525067