BLUETTI Portable Power Station User Manual
Models: EB120, EB150, EB180, EB240
Product Overview
The portable power station features several key components:
- A. Master power button: Controls the main power supply.
- B. DC power button: Controls DC output.
- C. AC power button: Controls AC output.
- D. LED indicator lamps: Provide status information.
- E. 5V-USB output ports: For charging USB devices.
- F. Type-C PD output port: For high-speed charging via USB-C PD.
- G. Display screen: Shows operational status and battery level.
- H. AC charger/PV input port: For charging the unit via AC adapter or solar panel.
- I. 12V cigarette lighter socket: For 12V DC appliances.
- J. AC100-120V outlet US standard socket: For AC power output.
LCD Display
The LCD display shows the following information:
- INPUT: Displays input power wattage.
- DC ON/OFF: Indicates the status of DC output.
- AC ON/OFF: Indicates the status of AC output.
- Indicators 1-5: Represent different power metrics or statuses.
- Indicator 6: Battery status indicator.
Safety Warnings
- Read all safety warnings and keep the manual for reference. Warranty does not cover damage from failure to follow instructions.
- Note and follow warning labels on the product.
- Avoid exposing the product to rain, humid environments, or direct sunlight.
- Do not install near heat sources like electric furnaces or heaters.
- Place and store the product in a well-ventilated area.
- Clean the product with a dry cloth only.
- In case of fire, use dry powder fire extinguishers. Do not use water, as it may cause electric shock.
- Do not alter or disassemble the product.
- For maintenance, contact designated personnel or the seller.
Storage and Maintenance
- Operating and storage environment affects product life and reliability. Store in a dry, well-ventilated area with mild temperatures (0°C - 40°C) and relative humidity of 10% - 90%.
- Place in a safe area where it won't be hit or shaken.
- Keep away from corrosive and combustible materials.
- The product will automatically shut off when the battery voltage is too low; recharge within 2-3 months.
- If not using for a long time, charge fully before storage and recharge at least once every month.
- Recharge fully before storage and at least once every 3 months.
Off-grid Power Storage System
The system diagram illustrates the flow of power:
- DC power or Solar Panel/Charger connects to a Charge Controller.
- The Charge Controller connects to the BMS (Battery Management System).
- The BMS connects to a Pure-sine-wave inverter (AC output controller) and a 12V/3A cigarette lighter socket.
- The inverter powers small appliances.
- The BMS also connects to Type-C/USB output ports, powering mobile phones and tablets.
- Car devices can be powered by the 12V cigarette lighter socket.
Unboxing
Before opening, check the parcel for damage. If damaged or items are missing, contact customer service at service@kayomaxtar.com. You should receive:
Item | Number of item |
---|---|
Portable solar power generator | 1 |
AC wall charger (Including AC input charging cable) | 1 |
PV solar charge cable (7909 to MC4) | 1 |
User manual | 1 |
Warranty card | 1 |
Certificate of qualification | 1 |
Operation Guidance
Attention:
- Ensure the operating environment meets requirements.
- Make sure air inlet/outlet is not blocked.
- Power off the product when not in use.
- Fully charge the product if it will be idle for a long period.
How to Use the Product
Turn On/Off the Product
- To turn on: Press and hold the master power button for about 2 seconds. The LED indicator and display screen will light up.
- To turn off: Press and hold the master power button for about 2 seconds. The display screen and LED indicator will turn off.
AC/DC Output
Note: Ensure the product is turned on before activating AC/DC output.
- To turn on AC/DC output: Press and hold the AC/DC power button. The corresponding LED indicator will light up, and the display will show "AC ON/DC ON".
- To turn off AC/DC output: Press and hold the AC/DC power button. The LED indicator will turn off, and the display will show "AC OFF/DC OFF".
PV Charge Activation
Turn off the generator, connect PV or charger to charge. The PV charge function activates, and the first column on the screen will show input power. The generator is in charging state and cannot support AC/DC functions. To enable AC/DC functions, press and hold the master power button for over 1 second to turn on the generator. After the generator is on, connect PV or charger to start charging; the screen will display input power wattage, and AC/DC functions can be enabled.
Notice:
- If the Master Power Button is off, AC and DC buttons are off, and no AC/DC output is available.
- If the Master Power Button is on, but AC and DC buttons are off, AC/DC output is not available. You must turn on the AC power button and DC power button separately.
How to Charge the Product
Charge with Solar Power
Connect the solar charging cable or AC adapter to the product's input port. The display will light up and show charging power. The product will not turn on by itself while charging. If it was turned off, it remains off unless manually turned on.
Charge with AC Power
Plug one end of the adapter into a wall outlet and the other end into the product's input port. The product will charge, and the battery status can be monitored via the battery icon on the LCD screen. The product has a built-in advanced control circuit and will stop charging automatically when fully charged.
Cold Weather
Cold weather can affect battery capacity. Discharging is possible in sub-zero temperatures (<0°C), but charging is not recommended as it can severely damage the battery and reduce its capacity permanently.
- Low temperature charging protection: If charged below 0°C, the product will shut off and stop charging. It will automatically restart charging when the temperature rises above 10°C.
- Low temperature discharging protection: If discharged at -20°C, the product will turn off. It will restart and turn on output when the temperature rises above -10°C.
FAQ
- Q1: How to check charging status? The battery icon indicates the battery level in 5 segments. The icon flashes while charging and becomes solid with all segments filled when fully charged.
- Q2: Can this product be used to charge my electronic devices? Check the power at each output port. The AC output port provides power via the built-in inverter with a maximum continuous output of 1000W. It is suitable for devices requiring no more than 1000W.
Intelligent Cooling Control
The cooling fan operates automatically under the following conditions:
- Inverter load exceeds 400W.
- 12V cigarette lighter socket load exceeds 80W.
- Charging power of attached appliances exceeds 100W.
The system also adjusts PV input or AC output power based on outer case temperature to maintain a touchable temperature. Do not use the machine if the cooling fan is broken.
Frequency Setting
With the product powered on, turn on DC output and keep AC output off. Press and hold both the DC and AC buttons for 1 second to enter frequency setting mode. Press the AC power button to select the inverter AC output frequency. Press and hold both DC and AC power buttons again to exit the mode. Restart the machine.
Troubleshooting
Error Code | Problem | Solution |
---|---|---|
E001 | Over-voltage protection (battery pack) | Stop charging and start discharging. |
E002 | Under-voltage protection (battery pack) | Charge the product promptly. Restart the machine once fully charged. |
E003 | Battery failure | Restart the machine and charge it. |
E004 | Over-temperature protection when discharging the battery. | Wait for it to cool down and then restart the machine. |
E005 | Under-temperature protection when discharging the battery. | Wait for it to heat up and then restart the machine. |
E006 | Over-temperature protection when charging the battery. | Wait for it to cool down and then restart the machine. |
E007 | Under-temperature protection when charging the battery. | Wait for it to heat up and then restart the machine. |
E008 | Under-voltage protection for the 1st cell. | Charge the product promptly and restart it when fully charged. |
E009 | Under-voltage protection for the 2nd cell. | Charge the product promptly and restart it when fully charged. |
E010 | Under-voltage protection for the 3rd cell. | Charge the product promptly and restart it when fully charged. |
E011 | Under-voltage protection for the 4th cell. | Charge the product promptly and restart it when fully charged. |
E012 | Busbar fault of inverter due to under-voltage. | Turn off and on the machine. |
E013 | Over-load protection of inverter. | Check if the output port of the inverter is overloaded. Turn off and on the AC output to recover. |
E014 | Output port of inverter is short-circuited. | Check if the output port of the inverter is short-circuited. Turn off and on the AC output to recover. |
E015 | The heat sink of inverter is overheated. | Wait for it to cool down and then restart the machine. |
E016 | The temperature of the heat sink is not detected. | Insert the NTC and restart the machine. |
E017 | Over-voltage protection (PV input). | Disconnect the solar charging cable and then restart the machine. |
E018 | Over-voltage protection (PV output). | Disconnect the solar charging cable, restart the machine, and then re-insert the solar charging cable. |
E019 | Over-temperature protection of heat sink for PV module. | The heat sink for the PV module overheats. Wait for it to cool down and then charge it. |
E020 | The temperature of the heat sink for PV module is not detected. | Restart the machine. |
E021 | Charging protection of battery protection board. | Wait for the temperature to return to an acceptable temperature and then start charging. |
E022 | Battery protection. | Disconnect the solar charging cable and restart the machine. |
E023 | Over-power protection (system). | Check if the total output power is overloaded. Restart the machine. |
If problems persist after trying the above solutions, contact the seller's customer service team.
ATTENTION! If you cannot find a solution, provide the following information to customer service:
- About the product: (1) Serial number, (2) Model, (3) Displayed information, (4) Description of problem, (5) Has it happened before?, (6) Circumstances of occurrence.
- About the solar panel (not included): (1) Manufacturer and model, (2) Output voltage, (3) Output power, (4) MPPT output voltage, (5) MPPT output current, (6) Number of panels and connection method.
Specifications
Model | EB120 | EB150 | EB180 | EB240 |
---|---|---|---|---|
Inverter Output | Output Specifications | |||
Continuous Output Voltage: 100-120Vac, 220-240Vac | ||||
Rated Frequency: 50/60Hz | ||||
Continuous Output Power: 1000W | ||||
Power Factor: 1 | ||||
THDV@0.7R (under nominal voltage): <5% | ||||
Over-load protection: 1000W ≤Load<1200W @2Min; 1200W≤Load @1s; | ||||
Power Loss (No Load & Turned-off): <20W | ||||
Max Efficiency (>70% Load): 88%(100-120Vac), 90%(220-240Vac) | ||||
12V/9A Cigar Lighter Output | Continuous Output Volt-age: 12.2V(±1V) | |||
Continuous Output Current: 9A | ||||
Output Voltage Range: 5V±0.3V | ||||
5V USB Output | Max Output Current: 3A (Note: Max output for single USB port is 3A. Max output for 2 USB ports is 3A) | |||
Supported Fast Charge: PD Protocol | ||||
Type-C PD Output | Output Voltage Range: 5-20V (5V by default) | |||
Continuous Output Volt-age/Current: (5V/9V/12V/15V)3A(±0.3A), 20V/2.25A(±0.2A) | ||||
Input Specification | ||||
AC Adapter Charger | 42V/200W | |||
PV Max Input Power | 500W | |||
PV Input Voltage Range | 16-60Vdc (OVP 73V±2V) | |||
PV Max Input Current | 10A | |||
MPTT Efficiency | 99.5% | |||
Max Efficiency | >88% | |||
Solar Charging Mode | MPPT | |||
Battery Specification | ||||
Rated voltage | 14.8Vdc | |||
Rated capacity | 1200Wh | 1500Wh | 1800Wh | 2400Wh |
Built-in battery cell | Li-ion | Li-ion | Li-ion | Li-ion |
Battery packing | 4S30P | 4S3P | 4S45P | 4S60P |
Min Unit | ||||
IP Rating | IP 21 | |||
Operating Environment | Relative Humidity: 10%-90% | |||
Operating Temperature: 0-40°C | ||||
Dimensions | 293.5*165.4*364.7mm | 371.5*165.4*364.7mm | 393.5*165.4*364.7mm | 493.5*165.4*364.7mm |
Net Weight | 12.6 KG | 17.2 KG | 17 KG | 22 KG |
Note: When total output power exceeds 1000W, DC output shuts down. If load is less than 30W, output power is not displayed. Actual output power may differ from displayed by up to 30W when a high-power appliance is connected.
Warranty
BLUETTI provides a 12-month warranty from the date of purchase.
Contact Us
For inquiries or comments, please contact seller at bluttipower@hotmail.com. They will respond as soon as possible.