BLUETTI Portable Power Station User Manual
Models: EB120, EB150, EB180, EB240
Product Overview
The BLUETTI Portable Power Station is a versatile energy storage solution. Key components include:
- A. Master power button: Turns the entire unit on/off.
- B. DC power button: Controls DC output.
- C. AC power button: Controls AC output.
- D. LED indicator lamps: Provide status information.
- E. 5V-USB output ports: For charging USB devices.
- F. Type-C PD output port: High-speed USB-C charging.
- G. Display screen: Shows operational status and battery level.
- H. AC charger/PV input port: For charging the unit via AC adapter or solar panels.
- I. 12V cigarette lighter socket: For 12V car accessories.
- J. AC100-120V outlet US standard socket: For standard AC appliances.
LCD Display
The LCD display provides the following information:
- 1. Charging power: Displays the power being received.
- 2. DC ON/OFF status: Indicates if DC output is active.
- 3. DC output power: Shows the current DC power output.
- 4. AC ON/OFF status: Indicates if AC output is active.
- 5. AC output power: Shows the current AC power output.
- 6. Battery status indicator: A visual representation of the remaining battery capacity, shown in segments. The icon flashes during charging and is fully illuminated when fully charged.
Note:
- If the product malfunctions, error codes will be displayed.
- The product may automatically turn off after 60 seconds of inactivity when powered on but not in use.
- The backlight may turn off after a period of inactivity when AC/DC output is on. Press any button to reactivate the backlight.
Safety Warning
- Do not cover the unit in a way that obstructs ventilation, as this can lead to damage due to improper operation.
- Adhere to all warning labels and operate the unit accordingly.
- Avoid exposing the product to rain or using it in humid environments.
- Do not install the product near heat sources like electric furnaces or heaters.
- Place and store the product in a well-ventilated area.
- Clean the product with a dry cloth only.
- In case of fire, use dry powder fire extinguishers. Do not use water-based extinguishers, as they may cause electric shock.
- Do not alter or disassemble the product.
- For maintenance, contact authorized service personnel or the seller.
Storage and Maintenance
Proper storage and environmental conditions are crucial for product longevity and reliability:
- Store the product in a dry, well-ventilated area with a temperature between 0°C and 40°C, and relative humidity between 10% and 90%.
- Ensure the storage area is safe and protected from impacts or shaking.
- Keep the product away from corrosive and combustible materials.
- If the battery voltage is too low, the product will shut off. Recharge the battery within 2-3 months in such cases.
- If storing for an extended period, fully charge the battery before storage and recharge it at least once a month.
- Always fully charge the product before storage and recharge it at least once every three months.
Off-grid Power Storage System Diagram
This diagram illustrates the system's components and their connections:
- DC power or Solar Panel/Charger connects to the Charge controller.
- The Charge controller connects to the BMS (Battery Management System).
- The BMS connects to the Pure-sine-wave inverter / AC output controller.
- The Pure-sine-wave inverter / AC output controller powers Small appliances.
- The BMS also connects to the 12V/9A cigarette lighter and the Type-C/USB output port.
- The 12V/9A cigarette lighter powers Car devices.
- The Type-C/USB output port powers Mobilephones, tablets.
Unboxing
Before opening the parcel, check for any damage. If the product is damaged or items are missing, contact customer service at service@kayomaxtar.com.
Item | Number of item |
---|---|
Portable solar power generator | 1 |
AC wall charger (Including AC input charging cable) | 1 |
PV solar charge cable (7909 to MC4) | 1 |
User manual | 1 |
Warranty card | 1 |
Certificate of qualification | 1 |
Operation Guidance
Attention:
- Ensure the operating environment meets requirements.
- Make sure the air inlet/outlet is not blocked.
- Power off the product if it will not be used.
- Fully charge the product if it will be idle for a long period.
How to use the product
Turn on/off the product
- To turn on: Press and hold the master power button for about 2 seconds. The LED indicator light and display screen will illuminate.
- To turn off: Press and hold the master power button for about 2 seconds. The display screen and LED indicator light will turn off.
AC/DC output
Note: Ensure the product is turned on before activating AC/DC output.
- To turn on AC/DC output: Press and hold the AC/DC power button. The corresponding LED indicator light will illuminate, and the display screen will show "AC ON/DC ON".
- To turn off AC/DC output: Press and hold the AC/DC power button. The LED indicator light will turn off, and the display screen will show "AC OFF/DC OFF".
PV charge activation
To charge via PV, turn off the generator, connect the PV (or charger), and activate the PV charge function. The generator will enter charging state, displaying input power. AC and DC functions are not supported during this state. To enable AC and DC functions, press and hold the master power button for over 1 second to turn on the generator. After startup, connect PV (or charger) to begin charging. The screen will show input power wattage, and AC/DC functions can then be enabled.
Notice:
- If the Master Power Button is off, AC and DC buttons are also off, and no AC/DC output is available.
- If the Master Power Button is on, but AC and DC buttons are off, no AC/DC output is available. Turn on the AC power button and DC power button separately.
How to charge the product
Charge with solar power
Insert the solar charging cable or AC adapter into the input port. The display screen will light up, showing the charging power. The product will not turn on automatically when being charged. If it was turned off previously, it will remain off until manually turned on.
Diagram: Sun -> Solar Panels -> Power Station -> Laptop
Charge with AC power
Connect the AC adapter to a wall outlet and the other end to the product's input port. The product will charge, and battery status can be monitored on the LCD screen. The product features a built-in advanced control circuit that automatically stops charging when the battery is full.
Diagram: Wall Outlet -> AC Adapter -> Power Station -> Laptop
Cold Weather
Cold temperatures can affect battery capacity. While discharging may be possible below 0°C, charging is not recommended as it can severely damage the battery and impair its capacity.
- Low temperature charging protection: If charged below 0°C, the product will shut off and stop charging. It will reboot and resume charging when the temperature rises above 10°C.
- Low temperature discharging protection: If discharged at temperatures below -20°C, the product will turn off. It will reboot and resume output when the temperature rises above -10°C.
FAQ
Q1: How to check charging status?
The battery icon on the display shows the battery level in 5 segments. The icon flashes while charging and is fully illuminated when the battery is fully charged.
Q2: Can this product be used to charge my electronic devices?
Check the power rating of each output port. The AC output port, powered by the built-in inverter, has a maximum continuous output of 1000W. Ensure your electronic devices do not exceed this requirement.
Intelligent Cooling Control
The cooling fan activates automatically under the following conditions:
- The load of the inverter exceeds 400W.
- The load of the 12V cigarette lighter socket exceeds 80W.
- The charging power of attached appliances exceeds 100W.
Additionally, the generator's intelligent system adjusts PV input or AC output power based on the external case temperature to maintain a touchable surface temperature.
Note: Do not operate the machine if the cooling fan is broken.
Frequency Setting
To set the frequency:
- With the product powered on, turn on DC output and keep AC output off.
- Press and hold both the DC button and the AC button to enter setting mode.
- Press the AC power button to choose the inverter AC output frequency.
- Press and hold both the DC and AC buttons to exit frequency setting mode. Restart the machine.
Troubleshooting and Technical Specification
Error Code | Problem | Solution |
---|---|---|
E001 | Over-voltage protection (battery pack) | Stop charging and start discharging. |
E002 | Under-voltage protection (battery pack) | Please charge the product in time. Restart the machine once it is fully charged. |
E003 | Battery failure | Restart the machine and charge it. |
E004 | Over-temperature protection when discharging the battery. | Wait for a while for it to cool down and then restart the machine. |
E005 | Under-temperature protection when discharging the battery. | Wait for a while for it to heat up and then restart the machine. |
E006 | Over-temperature protection when charging the battery. | Wait for a while for it to cool down and then restart the machine. |
E007 | Under-temperature protection when charging the battery. | Wait for a while for it to heat up and then restart the machine. |
E008 | Under-voltage protection for the 1st cell. | Please charge the product in time and restart it when fully charged. |
E009 | Under-voltage protection for the 2nd cell. | Please charge the product in time and restart it when fully charged. |
E010 | Under-voltage protection for the 3rd cell. | Please charge the product in time and restart it when fully charged. |
E011 | Under-voltage protection for the 4th cell. | Please charge the product in time and restart it when fully charged. |
E012 | Busbar fault of inverter due to under-voltage. | Turn off and on the machine. |
E013 | Over-load protection of inverter. | Check if the output port of the inverter is overloaded. Turn off and on the AC output to recover. |
E014 | Output port of inverter is short-circuited. | Check if the output port of the inverter is short-circuited. Turn off and on the AC output to recover. |
E015 | The heat sink of inverter is overheated. | Wait for it to cool down and then restart the machine. |
E016 | The temperature of the heat sink is not detected. | Insert the NTC and restart the machine. |
E017 | Over-voltage protection (PV input). | Disconnect the solar charging cable and then restart the machine. |
E018 | Over-voltage protection (PV output) | Disconnect the solar charging cable, restart the machine and then re-insert the solar charging cable. |
E019 | Over-temperature protection of heat sink for PV module | The heat sink for PV module overheats. Wait for it to cool down and then charge it. |
E020 | The temperature of the heat sink for PV module is not detected. | Restart the machine. |
E021 | Charging protection of battery protection board | Wait for the temperature to return to an acceptable temperature and then start charging. |
E022 | Battery protection | Disconnect the solar charging cable and restart the machine. |
E023 | Over-power protection (system) | Check if the total output power is overloaded. Restart the machine. |
ATTENTION!
If the solution for your problem is not found in the chart above, please provide the following information to the customer service team:
- About the product: Serial number, Model, Displayed information on the screen, Description of your problem, Whether it happened before, Circumstances of the problem occurrence.
- About the solar panel (not included): Manufacturer and model, Output voltage, Output power, MPPT output voltage, MPPT output current, Number of solar panels and connection method.
Specifications
Output Specifications
Model | EB120 | EB150 | EB180 | EB240 |
---|---|---|---|---|
Continuous Output Voltage | 100-120Vac, 220-240Vac | |||
Rated Frequency | 50/60Hz | |||
Continuous Output Power | 1000W | |||
Power Factor | 1 | |||
THDV@0.7R (under nominal voltage) | <5% | |||
Over-load protection | 1000W<Load<1200W@2Min; 1200W<Load@1s; | |||
Power Loss (No Load & Turned-off) | <20W | |||
Max Efficiency (>70% Load) | 88% (100-120Vac), 90% (220-240Vac) | |||
12V/9A Cigar Lighter Output Continuous Current | 9A | |||
12V/9A Cigar Lighter Output Voltage | 12.2V(±1V) | |||
5V USB Output Max Output Current | 3A | |||
Type-C PD Output Voltage Range | 5-20V(±5%) (5V by default) | |||
Type-C PD Output Continuous Volt-age/Current | (5V/9V/12V/15V)3A(±0.3A), 20V/2.25A(±0.2A) |
Input Specification
Item | Value |
---|---|
AC Adapter Charger | 42V/200W |
PV Max Input Power | 500W |
PV Input Voltage Range | 16-60Vdc (OVP 73V±2V) |
PV Max Input Current | 10A |
MPPT Efficiency | 99.5% |
Max Efficiency | >88% |
Solar Charging Mode | MPPT |
Battery
Specification | EB120 | EB150 | EB180 | EB240 |
---|---|---|---|---|
rated voltage | 14.8Vdc | |||
rated capacity | 1200Wh | 1500Wh | 1800Wh | 2400Wh |
built-in battery cell | Li-ion | |||
battery packing | 4S30P | 4S3P | 4S45P | 4S60P |
IPRating | IP 21 | |||
Operating Environment | Relative Humidity:10%-90%, Operating Temperature:0-40°C | |||
Dimensions | 293.5*165.4* 364.7mm | 371.5*165.4* 364.7mm | 393.5*165.4* 364.7mm | 493.5*165.4* 364.7mm |
Net Weight | 12.6 KG | 17.2 KG | 17 KG | 22 KG |
Note: When the total output power exceeds 1000W, the DC output will be directly shut down. When the load is less than 30W, the output power would not be displayed. When a high-power appliance is attached, the displayed output power and the actual output power could differ by up to 30W.
Warranty
BLUETTI provides a 24-month warranty from the date of purchase.
Contact us
For inquiries or comments regarding BLUETTI products, please contact seller at service@kayomaxtar.com. Responses will be provided as soon as possible.