R. STAHL 8530/1-MCB-STA103-C16-500-4 Circuit Breaker
Article No. 293900
Product Description
The R. STAHL 8530/1-MCB-STA103-C16-500-4 circuit breaker is part of the R. STAHL 8530 series, known for its excellent short-circuit current limitation and high breaking capacity (10, 15, or 25 kA). This results in reduced stress on electrical lines and improved selectivity with upstream fuses. The modules feature a modular design, available in 1 to 4-pole versions for nominal currents from 0.5–63 A. The maximum mounting capacity is 4.5 division units.
Key features include:
- Isolating function according to EN 60947-2
- Energy limiting class 3
- Easy replacement or expansion of installations due to modular design
- Simple mounting via DIN rail in Ex e enclosures
- Fixed thermal and magnetic trip settings
- Ergonomic operating lever for secure connection and disconnection
- Protection against reconnection during maintenance using padlocks (Accessories)
The product is certified for use in hazardous areas, including Zone 21/22 with Ex tb/tc enclosure protection.
Technical Data
Explosion Protection
Attribute | Value |
---|---|
Applications (zones) | 1, 2 |
Applications (zones) Note | Can be used in zones 21/22 with Ex tb/tc enclosure protection |
IECEX gas homologation | IECEX FMG 19.0029U |
IECEx gas explosion protection | Ex db eb IIC Gb |
ATEX gas homologation | FM19ATEX0191U |
ATEX gas explosion protection | II 2 G Ex db eb IIC Gb |
Certifications | ATEX (FM), Brazil (ULB), China (CQST), IECEX (FM) |
Certificate of conformity | ATEX conformity certificate |
Electrical Data
Attribute | Value |
---|---|
Rated operating voltage AC | 230/400 V |
Rated operating current | 16 A |
Frequency | 50/60 Hz |
Rated switching capacity | 10 kA |
Electrical service life | 2 x 104 |
Mechanical service life | 2 x 104 |
1st auxiliary function | Auxiliary contact 1 changeover + Signal contact 1 changeover |
Voltage 1st auxiliary function AC | 230 V |
Max. current 1st auxiliary function | 2 A |
2nd auxiliary function | None |
Max. voltage 2nd aux. function DC | - |
Trip characteristic | C |
Number of poles | 3-pole |
Environmental Conditions
Attribute | Value |
---|---|
Ambient temperature | -40 °C ... 70 °C |
Ambient temperature | -40 °F ... 158 °F |
Ambient temperature Note | Divergent ambient temperatures based on valid certificates upon request |
Mechanical Data
Attribute | Value |
---|---|
Degree of protection (IP) (IEC 60529) | IP2X |
Enclosure material | Thermoplastic |
Connection cross-section min. | 1.5 mm² |
Connection cross-section max. | 25 mm² |
Connection cross-section AWG min. | 16 AWG |
Connection cross-section AWG max. | 4 AWG |
Connection cross-section 2 min. | 1.5 mm² |
Connection cross-section 2 max. | 10 mm² |
Connection cross-section 2 AWG min. | 16 AWG |
Connection cross-section 2 AWG max. | 8 AWG |
Connection HIKO cross-section min. | 0.5 mm² |
Connection HIKO cross-section max. | 4 mm² |
Connection HIKO cross-section min AWG | 18 (unece.unit.AWG) |
Connection HIKO cross-section max AWG | 14 (unece.unit.AWG) |
Tightening torque min. | 2 N·m |
Tightening torque max. | 3 N·m |
Connection cross-section Note | 2 conductor connections (upper and lower chamber simultaneously): upper and lower chamber max. 16 / 10 mm² (only one cross-section difference between upper and lower chamber can be connected). Permitted connection cross-section combinations are listed in the operating instructions. |
Dimensions
Attribute | Value |
---|---|
Width | 110 mm |
Mounting width in inches | 4.33 in |
Length | 165 mm |
Length inches | 6.5 in |
Installation depth | 138.3 mm |
Installation depth inches | 5.44 in |
Weight | 1.8 kg |
Weight | 3.969 lb |
Mounting / Installation
Attribute | Value |
---|---|
Tightening torque | 2-3 N·m |
Tightening torque lbf in | 17.7 ... 26.6 lbf-in |
Tightening torque auxiliary contact | 0.4 - 0.6 N·m |
Tightening torque auxiliary contact lbf in | 3.5 ... 5.3 lbf in |
Technical Diagrams
Trip Time Characteristic Curve: A graph shows the trip time in seconds and minutes against multiples of the rated current (I/In). The curve illustrates the time-current characteristic for a Type C trip, with specific points indicated for different multiples of current.
Measurement Diagram: A diagram shows the dimensions of the circuit breaker, including width, length, and depth, with measurements provided in both millimeters and inches. It also indicates the unit's division size (8530/1; 4 division units).
Accessories
Cylinder Lock
Description: Padlock / tagout device for individual component lockout using up to 4 cylinder locks.
Article No.: 227232
Fixing Kit
Description: A fixing set for mounting the component on a mounting plate without a top hat rail.
Article No.: 276618
R. STAHL reserves the right to modify technical data, dimensions, weights, constructions, and delivery options.