R. STAHL 8530/1-MCB-STA103-C16-000-3 Circuit Breaker
This document provides technical specifications for the R. STAHL 8530/1-MCB-STA103-C16-000-3 circuit breaker, part number 272178.
Product Overview
The R. STAHL 8530 series circuit breakers are designed for systems technology and offer good current limitation in case of short circuits with a high breaking capacity of 10, 15, or 25 kA. This results in reduced load on electrical lines and high selectivity with respect to connected fuses. The modules feature a modular structure and are available in 1 to 4-pole versions for nominal currents from 0.5–63 A. The maximum mounting capacity is 4.5 division units.
Key features include:
- Separator function according to EN 60947-2
- Energy limitation class 3
- Simple substitution or expansion of installations due to modular design
- Easy mounting via DIN mounting rail in Ex e enclosures
- Fixed thermal and magnetic tripping adjustment
- Ergonomic operating lever for safe connection and disconnection
- Protection against re-energization during maintenance using padlocks (accessories)
Technical Data
Explosion Protection
Applications (zones) | 1, 2 |
Applications (zones) Note | Can be used in zones 21/22 with protection by Ex tb/tc enclosure |
IECEX gas certification | IECEX FMG 19.0029U |
IECEx protection against gas explosions | Ex db eb IIC Gb |
ATEX gas certification | FM19ATEX0191U |
ATEX protection against gas explosions | II 2 G Ex db eb IIC Gb |
Certifications | ATEX (FM), Brazil (ULB), China (CQST), IECEX (FM) |
Certificate of conformity | Certificate of conformity (ATEX), China (CCC) |
Electrical Data
Rated operating voltage AC | 230/400 V |
Rated operating current | 16 A |
Frequency | 50/60 Hz |
Rated switching capacity | 10 kA |
Electrical service life | 2 x 10⁴ |
Mechanical service life | 2 x 10⁴ |
1st auxiliary function | none |
Voltage 1st auxiliary function AC | - |
Maximum current 1st auxiliary function | - |
2nd auxiliary function | none |
Maximum voltage 2nd aux. function DC | C |
Tripping characteristic | C |
Number of poles | 3-pole |
Environmental Conditions
Ambient temperature | -40 °C ... 70 °C |
Ambient temperature | -40 °C ... 70 °C |
Ambient temperature | -40 °F ... 158 °F |
Ambient temperature | -40°F ... +158°F |
Ambient temperature Note | Divergent ambient temperatures based on valid certificates upon request |
Mechanical Data
Degree of protection (IP) (IEC 60529) | IP2X |
Enclosure material | Thermoplastic |
Minimum connection cross-section | 1.5 mm² |
Maximum connection cross-section | 25 mm² |
Minimum AWG connection cross-section | 16 AWG |
Maximum AWG connection cross-section | 4 AWG |
Minimum 2 connection cross-section | 1.5 mm² |
Maximum 2 connection cross-section | 10 mm² |
Minimum 2 AWG connection cross-section | 16 AWG |
Maximum 2 AWG connection cross-section | 8 AWG |
Minimum tightening torque | 2 N·m |
Maximum tightening torque | 3 N·m |
Connection cross-section Note | 2 connections of conductors (upper and lower chamber simultaneously): lower and upper chamber max. 16 / 10 mm² (only one cross-sectional difference can be connected as a maximum between the upper and lower chamber.) |
Width | 83 mm |
Mounting width in inches | 3.27 in |
Length | 165 mm |
Length in inches | 6.5 in |
Installation depth | 138.3 mm |
Installation depth in inches | 5.44 in |
Weight | 1.4 kg |
Weight in pounds | 3.087 lb |
Mounting / Installation
Tightening torque | 2-3 N·m |
Tightening torque lbf in | 17.7 ... 26.6 lbf-in |
Auxiliary contact tightening torque | 0.4–0.6 Nm |
Auxiliary contact tightening torque lbf in | 3.5 ... 5.3 lbf in |
Technical Diagrams
Tripping Characteristic
The document includes a graph illustrating the tripping characteristic (time-current curve) for the circuit breaker, showing the relationship between multiples of the rated current (I/In) and tripping time in seconds and minutes. It specifies the characteristic as 'C' for both AC and DC.
Tripping Characteristic C
[Graph showing time-current curves for circuit breaker tripping]
- Curve characteristic from cold state
- AC
- DC
Measurement Scheme
The document provides a measurement scheme with dimensions in millimeters and inches for the circuit breaker, indicating its overall size and mounting details.
[Diagram showing dimensions of the circuit breaker]
- 8530/1, 3 division units
Accessories
The following accessories are available for the circuit breaker:
- Cylinder lock: For locking (shackle Ø 3), Part No. 107115. This is a padlock/labeling shackle for individual component locking using up to 4 cylinder locks.
- Fixing kit: A fixing kit for mounting the component on the mounting plate without a top-hat rail. Part No. 276618.
R. STAHL Schaltgeräte GmbH reserves the right to modify technical data, dimensions, weights, constructions, and delivery options.