4-Way Cassette Heat Pump System
Submittal Data Sheet
Brand: Blue Ridge
Model Series: XS3 CC
Features ENERGY STAR certification, AHRI Certified, and ETL Listed compliance.
General Information
Field | Value |
---|---|
Location | |
Engineer | |
Submitted to | |
Submitted by | |
Reference | |
Approval | |
Date | |
Construction | |
Unit # | |
Drawing # |
Specifications
Indoor Unit Specifications
Parameter | Value |
---|---|
Indoor Air Flow (Turbo/H/M/L/Si) | 447.3/388.5/317.8/194.2/147.2 CFM |
Indoor Noise Level (Turbo/H/M/L/Si) | 48/44.0/41.0/28.5/24.5 dBA |
Dimension (W×D×H) | 22.44 x 22.44 x 9.65 inch / 570.0×570.0×245.0 mm |
Package (W×D×H) | 28.15 x 25.20 x 11.61 inch / 715×640×295 mm |
Net/Gross Weight | 35.27/41.89 lbs / 16.0/19.0 kg |
Outdoor Unit Specifications
Parameter | Value |
---|---|
Compressor Type | ROTARY |
Compressor Model | KSN140D58UFZ |
Refrigerant | R454B |
Refrigerant Oil Charge | 440 mL |
Refrigerant Oil | VG74 |
Outdoor Air Flow (Max) | 1765.8 CFM |
Outdoor Noise Level | 57.5 dBA |
Dimension (W×D×H) | 35.04 x 13.46 x 26.50 inch / 890.0×342.0×673.0 mm |
Package (W×D×H) | 39.17 x 15.67 x 29.13 inch / 995×398×740 mm |
Net/Gross Weight | 92.59/100.31 lbs / 42.0/45.5 kg |
Electrical Specifications
Parameter | Value |
---|---|
Power Supply | 208/230V, 60Hz, 1Ph |
System MCA | 18.00 A |
Connection Wiring | 14#x4 |
System MOCP | 20 A |
Compressor RLA | 10.0 A |
Outdoor Fan Motor RLA | 0.9 A |
Outdoor Fan Motor W | 80 W |
Indoor Fan Motor RLA | 1.0 A |
Indoor Fan Motor W | 45 W |
System Power Input @ Cooling | 1344 (490~1620) W |
System Power Input @ Heating | 1570 (395~1930) W |
MCA: Min. circuit amps | (A) |
MOCP: Max. over current protection | (A) |
RLA: Rated load amps | (A) |
W: Fan motor rated output | (W) |
Piping Specifications
Parameter | Value |
---|---|
Throttle type (Indoor) | N/A |
Throttle type (Outdoor) | EXV+Throttle valve |
Liquid Size | 6.35mm (1/4in) |
Gas Size | 12.7mm (1/2in) |
Max. Piping Length | 98.40 ft (30 m) |
Max. Height Difference | 65.60 ft (20 m) |
Max. Pre-charged Length | 24.6 ft (7.5 m) |
Refrigerant Pre-charged Amount | 47.97 oz (1.36 kg) |
Additional Charge of Refrigerant | 0.16 oz/ft (15 g/m) |
Connection Method | Flared |
Performance Data
Efficiency
Category | Value |
---|---|
Cooling (SEER2) | 20.7 |
Cooling (EER2) | 12.5 |
Heating (HSPF2-4) | 11.4 |
Heating (COP) | 3.36 |
Performance of Cooling
Parameter | Value |
---|---|
Rated Capacity | 16800 Btu/hr |
Min/Max Capacity | 5300~17800 Btu/hr |
Moisture Removal | 2.05 L/h |
Standard Operating Range | -13~122 °F (-25~50 °C) |
Conditions | Indoor: 80°F DB/67°F WB, Outdoor: 95°F DB/75°F WB |
Performance of Heating
Condition | Value |
---|---|
1. @ 47°F Rated Capacity | 18000 Btu/hr |
1. @ 47°F Min/Max Capacity | 7100~21500 Btu/hr |
2. @ 17°F Rated Capacity | 13900 Btu/hr |
3. @ 5°F Rated: Capacity / COP | 12800 / 2.20 |
3. @ 5°F Max: Capacity | 12800 Btu/hr |
Standard Operating Range | -13~75 °F (-25~24 °C) |
1. Conditions | Indoor: 70°F DB/60°F WB, Outdoor: 47°F DB/43°F WB |
2. Conditions | Indoor: 70°F DB/60°F WB, Outdoor: 17°F DB/15°F WB |
3. Conditions | Indoor: 70°F DB/60°F WB, Outdoor: 5°F DB/5°F WB |
Features
- 360° Air Flow
- Remote on-off and alarm ports
- Refrigerant leakage detection sensor (Optional)
- Humidity sensor
- Built-in pump
- 1~100% fan speed setting
- WiFi capability: through WiFi dongle or wired controller with built-in WiFi
- OTA (by using WiFi dongle)
- 2-pin connector (HA/HB) for programmable wired controller
- Multiple control options available:
- Two way communication wired controller: 120N(X6)
- Two way communication wired controller with built-in WiFi: 120N(X6W)
- Infrared wired controller: 120L
- Wireless remote controller
- Third-Party 24V Thermostat* (*24V interface is required.)
Dimensions and Installation
Indoor Unit Dimensions
The indoor unit is a rectangular cassette designed for ceiling installation. Key dimensions include a body width of approximately 22.5 inches (570mm), depth of 20.8 inches (531mm), and height of 9.6 inches (245mm). The front panel, which is visible when installed, has dimensions of approximately 24.4 inches (620mm) by 24.4 inches (620mm). Connections are located on the side of the unit, including liquid and gas refrigerant lines, a 1-inch (25mm) drain pipe, and a wiring connection port. A fresh air intake is also indicated.
Outdoor Unit Dimensions
The outdoor unit is a rectangular box shape with a fan grille on the front. Key dimensions include a width of approximately 35.0 inches (890mm) (or 35.25 inches/895mm overall), a depth of 13.5 inches (342mm) (or 13.75 inches/348mm overall), and a height of 26.2 inches (663mm) (or 26.5 inches/673mm overall). Various connection points and mounting details are shown, labeled with dimensions.
Installation Instructions and Clearances
Indoor Unit Installation: Requires specific ceiling clearances. A minimum of 59.1 inches (150cm) is recommended vertically from the ceiling to the unit, with 78.7 inches (200cm) recommended. Horizontal clearances from walls or obstructions are also specified: greater than 59.1 inches (150cm) on sides, greater than 78.7 inches (200cm) from the front, and greater than 90.6 inches (230cm) from the rear. The unit requires a ceiling hole and a front panel. A table provides specific distances from the ceiling and ceiling hole dimensions for different models:
MODEL | Length of A (Ceiling Hole) | Length of H (Distance from Ceiling) | Length of B (Overall Width) |
---|---|---|---|
9K/12K/18K | 9.6in (245mm) | >10.8in (275mm) | 23.6in (600mm) |
24K | 8.03in (205mm) | 9.06in (230mm) | |
36K | 9.65in (245mm) | 10.7in (271mm) | 35.4in (900mm) |
48K | 11.3in (287mm) | 12.3in (313mm) |
Outdoor Unit Installation: Requires adequate ventilation space. Minimum clearances are specified: 20 inches (500mm) or more on the front and sides when the unit is clear, and 14 inches (350mm) or more on the rear. If two sides (left, right, rear) are clear, 20 inches (500mm) is required on those sides. 4 inches (100mm) or more is required on the remaining sides.
Related Documents
![]() |
Blue Ridge 4-Way Cassette Heat Pump System: Submittal Data Sheet, Specifications, and Installation Comprehensive submittal data sheet for the Blue Ridge 4-Way Cassette Heat Pump System (Model EKPQ420D1UMUA). Includes detailed efficiency ratings, cooling and heating performance, indoor and outdoor unit specifications, electrical and piping data, dimensional drawings, and installation clearance requirements. |
![]() |
Blue Ridge Slim Duct Heat Pump System: Submittal Data Sheet & Specifications Detailed submittal data sheet for the Blue Ridge Slim Duct Heat Pump System, including specifications, performance data, dimensions, and installation clearances. Features R454B refrigerant and Energy Star certification. |
![]() |
Blueridge XS5 CC 4-Way Cassette Heat Pump System Submittal Data Sheet Comprehensive submittal data sheet for the Blueridge XS5 CC 4-Way Cassette Heat Pump System, featuring R454B refrigerant. Includes detailed specifications, performance data for cooling and heating, electrical requirements, piping information, and installation clearance guidelines. |
![]() |
Blue Ridge XS5 FC Ceiling & Floor Heat Pump System Submittal Data Sheet Submittal data sheet for the Blue Ridge XS5 FC Ceiling & Floor Heat Pump System, detailing specifications, performance, dimensions, and features for HVAC applications. |
![]() |
Blue Ridge XS5 CDH High Static Slim Duct Hyper Heat Series Submittal Data Sheet Submittal data sheet for the Blue Ridge XS5 CDH High Static Slim Duct Hyper Heat Series heat pump system, detailing efficiency ratings, cooling and heating performance, indoor and outdoor specifications, electrical requirements, piping details, installation guidelines, and fan performance. |
![]() |
Blue Ridge XS3 LW Series R454B Console Heat Pump Technical Specifications Comprehensive technical specifications for the Blue Ridge XS3 LW Series R454B Console Heat Pump. This document details cooling and heating performance metrics, indoor and outdoor unit specifications, electrical requirements, piping details, and key features. Designed for efficiency and performance, it includes Energy Star certification information. |
![]() |
Blue Ridge High Wall Heat Pump System: Technical Specifications and Installation Guide Comprehensive technical specifications, performance data, electrical requirements, and installation guidelines for the Blue Ridge High Wall Heat Pump System, including SEER2, HSPF2-4, and detailed operating conditions. |
![]() |
Blue Ridge DS2 High Wall Heat Pump System - Submittal Data Sheet Detailed submittal data sheet for the Blue Ridge DS2 High Wall Heat Pump System, including specifications for cooling, heating, electrical, piping, dimensions, and installation clearances. Features include humidity control and WiFi capability. |