Hikvision DS-PDPG12P-EG2 Wired PIR-Glass Break Detector
User Manual
1. Appearance
The detector consists of the following parts:
- 1. Lens
- 2. Pet Mask
- 3. LED Light Pipe
- 4. Lens Holder
- 5. Pick Up PCBA
- 6. Slider
- 7. Main PCBA
- 8. Screw
Main Printed Circuit Board Assembly (PCBA) Components:
- 1. PIR Sensor
- 2. BG Potentiometer
- 3. PIR Sensitivity Settings
- 4. Tamper Resistor Pin
- 5. PIR Alarm Resistor Pin
- 6. Microphone
- 7. Terminal
- 8. BG Alarm Resistor Pin
- 9. Tamper Spring
- 10. LED ON/OFF Switch
- 11. Link Settings
2. Installation
Screw Model: PA_3.5 × 25 (4 screws)
Mounting Options:
- A. Wall Mounting
- B. Bracket Mounting (optional)
- 4a. Ceiling Bracket Mounting
- 4b. Wall Bracket Mounting
Step 5: Knock out the hole and adjust the slider direction.
Resistor Wiring
Connection Type:
- Method 1: Use the jumper to select EOL (End of Line) resistance on TAMPER/ALARM pins.
- Method 2: Add the resistor to TAMPER/ALARM wiring ports.
Note: If EOL wiring is not used, leave the jumpers OFF. Do not force the jumper if it is not matched to the pin. Method 1 & 2 should not be used on the ALARM/TAMPER at the same time.
Resistor Values:
- a. Tamper Resistance: 1K, 2K2, 4K7, 5K6
- b. PIR Alarm Resistance: 1K, 2K2, 4K7, 5K6, 6K8
- c. BG Alarm Resistance: 1K, 2K2, 4K7, 5K6, 6K8
Note: The resistor must be connected in series with one end of the detector.
3. Specification
Detection Range: 12 m, 85.9°
Detectable Speed: 0.3 to 2 m/s
Pet Immunity: 30 Kg
PIR Sensitivity: Auto, Pet
White Light Filter: 6500 lux
Glass Break Range: 8 m
Glass Type: Float, Coated, Tempered, Laminated, Sealed Insulating, Wired
Digital Temperature Compensation: Support
Creep Zone Protection: Support
Digital Processing: Support
Sealed Optics: Support
Tamper Protection: Front
LED Indicator: Green (PIR), Red (BG), Blue (alarm)
Power Supply: 9 to 16 VDC (standard: 12 VDC)
Power Consumption: 36 mA
Operation Temperature: -10 °C to 55 °C (14 °F to 131 °F)
Storage Temperature: -20 °C to 60 °C (-4 °F to 140 °F)
Operation Humidity: 10% to 90%
Dimension (W×H×D): 65.5 mm × 103 mm × 48.5 mm
Weight: 98.5 g
Mounting Height: 1.8 to 2.4 m
Mounting Method: Wall
Application Scenario: Indoor
Bracket: Optional Wall & Ceiling Accessory
Glass Thickness: 3 mm to 6.4 mm
Glass Size: 0.3 m × 0.3 m to 3 m × 3 m
4. Relay Status
Status | PIR Alarm Relay | BG Alarm Relay | Tamper Relay |
---|---|---|---|
Normal | Close | Close | Close |
PIR Intrusion/Fault | Open | Close | Close |
BG Intrusion/Fault | Close | Open | Close |
Tamper | Close | Close | Open |
5. Indicators
- PIR Triggered: Green LED
- BG Triggered: Red LED
- Fault: PIR: Green LED, BG: Red LED, BG&PIR: Orange LED
Important Installation Guidelines
- Avoid mounting the detector on the same wall as the protected glass.
- Avoid mounting the detector in rooms with noisy equipment (air compressors, power tools, bells, etc.).
- Avoid mounting the detector in humid rooms (bathroom, etc.).
- Avoid mounting the detector on the wall with strong vibration.
- Ensure that curtains, plants, furniture, or other objects do not obstruct the microphone opening.
- If curtains are present on the window, place the detector between them and the window, for instance, at the window side jamb. Otherwise, curtains can mute the glass break sound, and the detector will not be triggered.
- Before installing the detector, ensure you have selected the optimal location that follows the guidelines of this manual.
- Use a power adapter compliant with LPS. The recommended power adapter is made by Shenzhen Honor Electronic Co., Ltd.
- Use power supplies that comply with the requirements of EN 50131-6 at the appropriate grade and environmental class.
- Do not obscure the detector's field of view with large objects like furniture or curtains.
Certifications
- EN 50131-2-2:2017
- EN 50131-2-7-1+A1+A2
- Security Grade 2, Environment Class II
- Certified by TÜV Rheinland