Hikvision DS-PDD12P-EG2-WB/WE Wireless Dual-Tech Detector
About this Manual & Disclaimer
This manual provides instructions for using and managing the Product. Information herein is for description and explanation only and is subject to change without notice due to firmware updates or other reasons. The latest version can be found on the Hikvision website (https://www.hikvision.com/). Use this manual with the guidance of trained professionals.
Hikvision trademarks and logos are properties of Hikvision. Other trademarks belong to their respective owners.
Disclaimer: To the maximum extent permitted by applicable law, this manual and the product are provided "AS IS" and "WITH ALL FAULTS AND ERRORS". Hikvision makes no warranties, express or implied. Use of the product is at your own risk. Hikvision shall not be liable for any damages resulting from product use, including business loss, interruption, or data loss. Hikvision is not responsible for abnormal operation, privacy leakage, or damages from cyber-attacks, hacker attacks, or virus inspections, but will provide timely technical support if required. Users agree to comply with all applicable laws and are solely responsible for ensuring their use conforms to the law, including not infringing on third-party rights. The product shall not be used for prohibited end-uses, including weapons development or human rights abuses.
In case of conflict between this manual and applicable law, the latter prevails.
Compliance Information
[CE Mark] This product and its accessories comply with applicable harmonized European standards listed under the EMC Directive 2014/30/EU, RE Directive 2014/53/EU, and the RoHS Directive 2011/65/EU.
2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the EU. For proper recycling, return this product to your local supplier or dispose of it at designated collection points. More information: www.recyclethis.info
2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste. See product documentation for specific battery information. The battery is marked with this symbol, which may include lettering for cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or a designated collection point. More information: www.recyclethis.info
1 Appearance
CAUTION: IF THE BATTERY COMPARTMENT DOES NOT CLOSE SECURETLY, STOP USING THE PRODUCT AND KEEP IT AWAY FROM CHILDREN.
CAUTION: CHEMICAL BURNING DANGER. DO NOT SWALLOW THE BATTERY. KEEP NEW AND USED BATTERIES AWAY FROM THE CHILDREN. IF YOU THINK BATTERIES MIGHT HAVE BEEN SWALLOWED OR PLACED INSIDE ANY PART OF THE BODY, SEEK IMMEDIATE MEDICAL ATTENTION.
The detector features an Indicator light, a Battery compartment, a Bracket Tamper Port, a Tamper Switch, and a Power Switch.
CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. REPLACEMENT OF A BATTERY WITH AN INCORRECT TYPE THAT CAN DEFEAT A SAFEGUARD.
CAUTION: DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS AND LOCAL REGULATION.
2 Enrollment
Note: Enrollment typically completes in 3 to 10 seconds, with a maximum duration of 3 minutes.
Enrollment Methods:
- Via APP Store: Log in to the APP Store, download, and install the Hik-Pro application.
- Control Panel Setup: Power on the security control panel.
- Add Control Panel: Log in to the Hik-Pro APP, tap the ➕ icon, and scan the QR code or input the control panel serial number.
Enroll the Peripheral Locally:
- In the APP, tap the "Enrollment Mode" button on the control panel page to enter enrollment status.
- Loosen the screw and remove the rear panel.
- Power on the peripheral; it will be automatically enrolled to the control panel.
Enroll the Peripheral with QR and serial No.:
- In the APP, tap the ➕ icon and scan the QR code or serial No. on the peripheral.
- Loosen the screw and remove the rear panel.
- Power on the peripheral; it will be automatically enrolled to the control panel.
Note: To re-enroll, hold the tamper button, power off the device, and then power it on again.
Signal Strength Test:
Enter the signal checking mode via the control panel and trigger the detector. Indicators are:
- Solid Green for 3s: Strong Signal
- Solid Orange for 3s: Medium Signal
- Solid Red for 3s: Weak Signal
- Red light flashes for 3s: Failure
Check the installation environment:
Diagrams show various room scenarios with furniture and windows. Correct detector placement is indicated by checkmarks (✔️), while incorrect placement is shown with crosses (❌).
3 Installation
Note: The additional force applied during installation shall be equal to three times the equipment's weight, but not less than 50N. The equipment and mounting must remain secure and undamaged after installation.
With Screws:
- Knock out the screw holes on the rear panel.
- Secure the rear panel on the wall with four screws.
With Sponge Tape:
Paste the device on the wall with sponge tape.
Bracket Installation:
Two bracket fitting methods are shown: Ceiling Bracket Fitting (Non EN compliant) and Wall Bracket Fitting, illustrating how the detector attaches to the bracket and the bracket to the wall.
4 Test
Detector zones and planes:
The zones and planes of the PIRCAM are shown below.
A polar graph illustrates the detector's detection coverage, showing zones and planes extending up to 12 meters with specific angles.
The detector offers a detection range of 85.9 degrees, covering 52 zones across 4 planes.
Walk Test:
The detector enters a 3-minute walk test mode after enrollment. Trigger the detector within its range. A blue indicator light signifies proper installation; if the light is off, the detector's position needs adjustment.
5 Formatting
Hold the tamper switch for 8 seconds and power the device on simultaneously. A red LED flashing 3 times confirms formatting completion.
6 Set up with App
Link the detector to a zone using the Hik-Pro app (AX PRO). On the device list page, log in to the device to enter the Area page. Tap "Device", then tap the zone. You can view device status including temperature, battery status, and signal strength. Tap the ⚙️ icon in the upper right corner to access the Settings page.
Function | Description |
---|---|
Zone Type | Select the zone type of the detector (e.g., instant zone, 24-hour zone). |
Stay Arm Bypass | Slide to green to bypass the zone from stay arming. |
Forbid Bypass on Arming | Slide to green to forbid zones with faults from being automatically bypassed when arming. |
Chime | Slide to green to enable the chime. |
Silent Alarm | Slide to green to make the zone remain silent while an alarm is triggered. |
Sounder Delay Time | Set the delay time. The sounder will be triggered immediately or after the set time. |
Double Knock | Slide to green to make the zone alarm with double knock. |
Cross Zone | If an alarm is triggered in both linked zones within the set time, two alarm messages will be reported. |
Link Camera | Link with a camera for intruder verification. |
LED | Turn On/Off the LED. |
Swinger limit activations | Set the limit times of swinger activation. |
Polling Rate | Set the interval of heartbeat. |
Signal Strength Test | Enter the test mode and view the LED indication. |
Detection Zone Test | Enter the test mode and start walk test. |
Find Me | Tap Find Me to make peripherals find the zone. |
Bypass | Slide to green to bypass the zone. |
7 Operation Caution and Device Maintenance
- All electronic operations must comply with local electrical safety, fire prevention, and other relevant regulations.
- Do not drop the device or subject it to physical shock. Avoid exposure to high electromagnetic radiation. Do not install on vibrating surfaces or places subject to shock, as this can cause equipment damage.
- Ensure power is disconnected before wiring, installing, or dismantling the device.
- If smoke, odors, or noise arise from the device, immediately turn off the power, unplug the power cable, and contact the service center.
- Do not place the device in extremely hot, cold, dusty, or damp locations, or expose it to high electromagnetic radiation. Refer to specifications for detailed operation temperature ranges.
- The device is for indoor use and must be kept from rain and moisture.
- Exposing the equipment to direct sunlight, low ventilation, or heat sources like heaters or radiators is forbidden, as it may cause fire danger.
- Do not aim the device at the sun or extra bright places, as this may cause blooming or smear, affecting sensor endurance.
- Improper use or battery replacement can cause explosion hazards. Use only the same or equivalent battery type. Dispose of used batteries according to the manufacturer's instructions.
- Do not expose the device to corrosive gas, as it may cause damage.
- Do not expose the device to explosive situations.
8 Specification
Category | Parameter | Value |
---|---|---|
Model | Model | DS-PDD12P-EG2-WB/WE |
Detection Performance | Detection Method | Passive Infrared, Microwave |
Sensor Model | SFG321-711 | |
Detection Range | 12m | |
Detection Angle | 85.9° | |
Detection Zones | 52 | |
Detectable Speed | 0.3 to 2m/s | |
Sensitivity | Auto, High, Pet | |
Feature | Pet Immunity | 30Kg |
White Light Filter | 6500lux | |
Microwave Frequency | 24GHz (24.15~24.25GHz) | |
Digital Temperature Compensation | Support | |
Creep Zone Protection | Support | |
Digital Processing | Support | |
Sealed Optics | Support | |
Tamper Protection | Front, Rear | |
Environment Temperature Indicator | Support | |
Signal Strength Indicator | Support | |
Interface | Power Switch | Power Up Enrolling |
LED Indicator | Green (PIR), Red (Microwave), Blue (Alarm) | |
Transmission | Transmission Technology | Tri-X Wireless |
Transmission Method | Two-Way RF Wireless | |
Transmission Frequency | 433MHz/868MHz | |
Transmission Security | AES-128 Encryption | |
Transmission Range (Free Space) | 1.2 Km (433MHz) / 1.6 Km (868MHz) | |
Frequency Hopping | Support | |
Enrolling Method | Enrolling Method | Power up, Remote ID, QR Code |
Electrical Characteristics | Power Supply | Battery Powered |
Battery Type | CR123A × 2 | |
Typical Voltage | 3V | |
Standard Battery Life | 5 Years | |
General | Operation Temperature | -10 °C to 55 °C (14 °F to 131 °F) |
Storage Temperature | -20 °C to 60 °C (-4 °F to 140 °F) | |
Operation Humidity | 10% to 90% | |
Dimension (WxHxD) | 65.5mm × 103mm × 48.5mm |