Hikvision DS-PDBG8-EG2 Wired Glass Break Detector
1. Appearance
The detector consists of the following parts:
- Front Panel
- LED Light Pipe
- PCB (Printed Circuit Board)
- Rear Panel
The PCB features:
- Tamper Resistor Headers
- Alarm Resistor Headers
- Sensor
- Adjustable Resistance (Detection range: 0 to 8 m)
- Terminal
- Tamper Protection
- Alarm LED Latch/Normal (Latch, Stay On, Normal)
- LED ON/OFF switch
LED Indicators:
- Blue: Alarm
- Green: Flex Activation
- Red: Shatter Activation
2. Resistor Wiring
Two methods are available for resistor wiring:
- Method 1: Use the jumper to select EOL (End of Line) resistance on ALARM/TAMPER pins.
- Method 2: Add the resistor to ALARM/TAMPER wiring ports.
Note: If EOL wiring is not used, leave the jumpers OFF. Do not force the jumper if it is not matched to the pin. Methods 1 & 2 should not be used on the ALARM/TAMPER at the same time.
Available resistor values:
- Alarm Resistance: 1K, 2K2, 4K7, 5K6, 6K8
- Tamper Resistance: 1K, 2K2, 4K7, 5K6
3. Connection Type
Connect the detector to the Alarm Control Panel.
- Normally Closed (NC) connection: The resistor must be connected in series with one end of the detector.
- Double End of Line (DEOL) Wiring: Example connection: Normal: 1K, Alarm: 4.4K, Tamper: Infinite.
4. Test
Perform a BG (Break Glass) Test.
5. Installation
General Guidelines:
- Do not obscure the detector's field of view with large objects.
- Ensure curtains, plants, or furniture do not cover the microphone opening.
- If curtains are present, place the detector between them and the window.
- Select the optimal location following the guidelines in this manual.
- Avoid mounting the detector in rooms with noisy equipment (air compressors, power tools, bells, etc.).
- Avoid mounting the detector on the same wall as the protected glass.
- Avoid mounting the detector in humid rooms (bathroom, etc.).
- Avoid mounting the detector on a wall with strong vibration.
Specifications
| Parameter | Specification |
|---|---|
| Sensor | Omnidirectional electret microphone |
| Power Supply | 8 to 16 VDC (standard: 12 VDC) |
| Current Consumption | 25mA quiescent and maximum at 12V DC |
| Detection Range | 8 m (25 ft) |
| Glass Type | Float, plate, tempered, wired, laminated, double glazing |
| Glass Thickness | 2.4 mm to 6.4 mm |
| Glass Size | 0.4 m x 0.4 m to 3 m x 3 m |
| Tamper Protection | Front |
| LED Indicator | Blue (alarm), green (flex activation), red (shatter activation) |
| Operating Temperature | -10°C to 55°C (14°F to 131°F) |
| Storage Temperature | -20°C to 60°C (-4°F to 140°F) |
| Operating Humidity | 10% to 90% |
| Installation | Wall/Ceiling mount |
| Dimensions (HxWxD) | 107mm x 38.8mm x 22.5mm |
| Weight | 49.5 g |
Legal and Regulatory Information
This product complies with relevant European harmonized standards, including the RE Directive 2014/53/EU, EMC Directive 2014/30/EU, and RoHS Directive 2011/65/EU.
Disposal information regarding WEEE (Waste Electrical and Electronic Equipment) and batteries is provided, advising proper recycling and disposal methods according to EU directives.
Installation Caution: Additional force should equal three times the weight of the equipment, but not less than 50N. The equipment and its associated mounting means must remain secure during installation. After installation, the equipment, including any associated mounting plate, shall not be damaged.