R. STAHL 8530/1-MCB-STA103-C40-000-3 Circuit Breaker
Article Number: 272182
The R. STAHL 8530/1-MCB-STA103-C40-000-3 circuit breaker is designed for systems requiring high performance and safety, particularly in potentially explosive atmospheres (Ex e installations). It offers robust protection and reliable operation.
Key Features
- Switch disconnector function according to EN 60947-2
- Energy limitation class 3
- Simple replacement or expansion of protection switch installations
- Easy mounting via DIN rail clip in Ex e enclosures
- Fixed thermal and magnetic trip settings
- Ergonomic operating lever for secure connection and disconnection
- Protection against reconnection during maintenance using padlocks (Accessories)
Technical Data
Explosion Protection
- Applications (zones): 1, 2
- Applications (zones) Note: Can be used in zones 21/22 with Ex tb/tc enclosure protection
- IECEX gas certification: IECEX FMG 19.0029U
- IECEx gas explosion protection: Ex db eb IIC Gb
- ATEX gas certification: FM19ATEX0191U
- ATEX gas explosion protection: II 2 G Ex db eb IIC Gb
- Certifications: ATEX (FM), Brazil (ULB), China (CQST), IECEX (FM)
- Certificate of conformity: Certificate of conformity (ATEX), China (CCC)
Electrical Data
- Rated operating voltage AC: 230/400 V
- Rated operating current: 40 A
- Frequency: 50/60 Hz
- Rated switching capacity: 10 kA
- Electrical service life: 104
- Mechanical service life: 2 x 104
- 1st auxiliary function: None
- Rated voltage 1st auxiliary function AC: -
- Max. current 1st auxiliary function: -
- 2nd auxiliary function: None
- Max. voltage 2nd auxiliary function DC: C
- Trip characteristic: C
- Number of poles: 3-pole
Environmental Conditions
- Ambient temperature: -40 °C ... 70 °C
- Ambient temperature: -40 °F ... 158 °F
- Ambient temperature Note: Divergent ambient temperatures based on valid certificates upon request
Mechanical Data
- Degree of protection (IP) (IEC 60529): IP2X
- Enclosure material: Thermoplastic
- Minimum connection cross-section: 1.5 mm²
- Maximum connection cross-section: 25 mm²
- Minimum AWG connection cross-section: 16 AWG
- Maximum AWG connection cross-section: 4 AWG
- Minimum connection cross-section 2: 1.5 mm²
- Maximum connection cross-section 2: 10 mm²
- Minimum AWG connection cross-section 2: 16 AWG
- Maximum AWG connection cross-section 2: 8 AWG
- Minimum tightening torque: 2 N·m
- Maximum tightening torque: 3 N·m
- Connection cross-section Note: 2 conductor connections (upper and lower chamber simultaneously): lower and upper chamber max. 16 / 10 mm² (only a maximum cross-sectional difference between the upper and lower chamber can be connected). Permitted connection cross-section combinations are listed in the user instructions.
- Width: 83 mm (3.27 in)
- Length: 165 mm (6.5 in)
- Installation depth: 138.3 mm (5.44 in)
- Weight: 1.4 kg (3.087 lb)
Mounting / Installation
- Tightening torque: 2-3 N·m (17.7 ... 26.6 lbf-in)
- Tightening torque auxiliary contact: 0.4–0.6 Nm (3.5 ... 5.3 lbf in)
Technical Diagrams
Trip Time Characteristic Curve: The document includes a graph illustrating the tripping characteristic for the 'C' trip characteristic, showing time in seconds and minutes against multiples of the rated current (I/In). This curve indicates the device's response to overcurrents.
Dimensional Drawings: Schematics provide detailed measurements of the circuit breaker, including width, height, and depth, with dimensions provided in both millimeters and inches. These diagrams are essential for installation planning.
Accessories
- Cylinder lock: For blocking (shackle Ø 3). Article No.: 107115
- Quadruple immobilization device: Locking/tagging tool for individual component locking using up to 4 cylinder locks. Article No.: 227232
- Fixing kit: A set of fixings for mounting the component on a mounting plate without a top-hat rail. Article No.: 276618
R. STAHL Schaltgeräte GmbH reserves the right to modify technical data, dimensions, weights, designs, and delivery options.