Elk Home
Installation Guide for Models 69314/4 and 69324/4
Questions? Call: 800-613-3261 (M-F 8:00AM-6:00PM ET)
Important Safety Information
WARNING: DISCONNECT POWER AT THE MAIN FUSE BOX BEFORE INSTALLATION.
This fixture is intended for installation in accordance with the National Electrical Code (NEC) and all local code specifications. If you are not familiar with code requirements, installation by a certified electrician is recommended.
Before assembly, remove all parts and part packages from box. If anything is missing, please contact the retailer from which the product was purchased.
Installation Steps
- Carefully pull house wires out of junction box so they are easily accessible during installation.
- Position mounting bracket (A) so threaded ends of attached fixture mounting screws (E) are facing down towards floor.
- Carefully pull house wires through center hole in mounting bracket (A). Align small holes in mounting bracket (A) with holes in junction box.
- Thread each junction box screw (B) into appropriate hole in mounting bracket (A) and into hole in junction box. Tighten junction box screws (B) to secure mounting bracket (A) to junction box.
- CAUTION: Make sure house wires are pulled completely through hole in mounting bracket. DO NOT pinch wires between mounting bracket and ceiling.
- Rotate arms until arms are evenly spaced apart.
- Strip 3/4" of insulation from ends of fixture wires.
- Slightly loosen ground screw on mounting bracket (A). Do not completely remove ground screw. Wrap house ground wire (copper) around ground screw, leaving enough ground wire to attach to fixture ground wire. Twist end of fixture ground wire and end of house ground wire (copper) together. Twist wire nut (C) onto ends of wires. Completely tighten wire nut (C). Reference chart below for correct wire connections.
- Twist end of house lead wire (black) and end of fixture lead wire together. Twist wire nut (C) onto ends of wires. Completely tighten wire nut (C). Twist end of house neutral wire (white) and end of fixture neutral wire together. Twist wire nut (C) onto ends of wires. Completely tighten wire nut (C). Reference chart to the right for correct wire connections.
- Wrap electrical tape (not included) around wire nuts (C) and wires. Ensure wires are securely fastened into wire nuts.
- Carefully push all wires and wire nuts into junction box.
- Carefully raise fixture up to ceiling. Place canopy (D) of fixture over mounting bracket (A). Pass holes in canopy (D) over ends of fixture mounting screws (E).
- Screw one threaded cap (F) onto end of each fixture mounting screw (E). Tighten threaded caps (F) to secure fixture to ceiling. DO NOT over tighten.
- Screw recommended bulbs (E26 Edison bulb type, not included) into sockets. Verify correct bulb wattage marked on socket of fixture. WARNING: DO NOT exceed maximum bulb wattage.
Wiring Connections
Ground Wire Connection
Connect Supply (House) Ground Copper Wire to:
- Bare Copper Wire or,
- Bare Silver Wire or,
- Green Insulated Wire.
Diagram Description: Illustrates connecting the house ground wire (copper) to the ground screw on the mounting bracket (A), and then connecting it to the fixture ground wire using a wire nut (C).
Lead and Neutral Wire Connections
Reference chart for correct wire connections.
Connect Black Lead Supply (House) Wire to: | Connect White Neutral Supply (House) Wire to: |
---|---|
Black Wire or, | White Wire or, |
*Parallel Cord (Round and Smooth) or, | *Parallel Cord (Square and Ridged) or, |
No printed words on wire insulation or, | Printed words on wire insulation or, |
Insulated Wire (other than green) with Copper Conductor. | Insulated Wire (other than green) with Silver Conductor. |
*When parallel wire (SPT 1 & SPT 2) is used: The lead wire is round in shape or smooth. The neutral wire is square in shape or ridged.
Diagram Description: Shows the fixture's lead wire, ground wire, and neutral wire, and how they connect to the corresponding house wires (black, copper, white) using wire nuts (C).
Diagrams Overview
Diagram 1 (Page 1): Illustrates the initial mounting bracket (A) attachment to the junction box using screws (B). Shows the mounting bracket with screws (E) extending downwards.
Diagram 2 (Page 2): Depicts the wiring connections between fixture wires and house wires using wire nuts (C). Also shows the final assembly with canopy (D), screws (E), and caps (F) securing the fixture to the ceiling.
Diagram 3 (Page 3): Similar to Diagram 1, showing the mounting bracket (A) and junction box screws (B) for attaching the bracket to the junction box.
Diagram 4 (Page 4): Similar to Diagram 2, illustrating wiring connections and the final assembly steps with canopy (D), screws (E), and caps (F).
Diagram 5 (Page 5): Similar to Diagram 1, showing the mounting bracket (A) attachment to the junction box.
Diagram 6 (Page 6): Similar to Diagram 2, detailing wiring connections and the final assembly with canopy (D), screws (E), and caps (F).