R. STAHL 8530/1-MCB-STA103N-B32-000-4 Circuit Breaker
This document provides detailed technical specifications for the R. STAHL 8530/1-MCB-STA103N-B32-000-4 circuit breaker, part number 293849.
Key Features
- Function as a separator according to EN 60947-2
- Energy limitation class 3
- Easy replacement or expansion of installations due to modular design
- Simple mounting via DIN rail snap-on in Ex e enclosures
- Fixed thermal and magnetic tripping adjustment
- Ergonomic operating lever for secure connection and disconnection
- Protection against reconnection during maintenance using padlocks (accessories)
Technical Data
Explosion Protection
- Applications (zones): 1, 2
- Applications (zones) Note: Can be used in zones 21/22 with Ex tb/tc enclosure protection
- Homologation IECEx gas: IECEx FMG 19.0029U
- IECEx Gas Explosion Protection: Ex db eb IIC Gb
- Homologation ATEX gas: FM19ATEX0191U
- ATEX Gas Explosion Protection: II 2 G Ex db eb IIC Gb
- Certifications: ATEX (FM), Brazil (ULB), China (CQST), IECEx (FM)
- Certificate of Conformity: Certificate of Conformity (ATEX)
Electrical Data
- Rated operating voltage AC: 230/400 V
- Rated operating current: 32 A
- Frequency: 50/60 Hz
- Rated switching capacity: 10 kA
- Electrical service life: 2 x 10⁴
- Mechanical service life: 2 x 10⁵
- 1st auxiliary function: none
- Rated voltage 1st auxiliary function AC: -
- Max. current 1st auxiliary function: -
- 2nd auxiliary function: none
- Max. voltage 2nd aux. function DC: -
- Trip characteristic: B
- Number of poles: 3 pole + N
Environmental Conditions
- Ambient temperature: -40 °C ... 70 °C
- Ambient temperature: -40 °F ... 158 °F
- Ambient temperature Note: Divergent ambient temperatures based on valid certificates upon request
Mechanical Data
- Degree of protection (IP) (IEC 60529): IP2X
- Enclosure material: Thermoplastic
- Minimum connection cross-section: 1.5 mm²
- Maximum connection cross-section: 25 mm²
- Minimum AWG connection cross-section: 16 AWG
- Maximum AWG connection cross-section: 4 AWG
- Minimum connection cross-section 2: 1.5 mm²
- Maximum connection cross-section 2: 10 mm²
- Minimum AWG connection cross-section 2: 16 AWG
- Maximum AWG connection cross-section 2: 8 AWG
- Minimum tightening torque: 2 N·m
- Maximum tightening torque: 3 N·m
- Connection cross-section Note: 2 conductor connections (upper and lower chamber simultaneously): max. lower and upper chamber 16 / 10 mm² (only a maximum difference in cross-section between the upper and lower chamber can be connected). Permitted connection cross-section combinations are shown in the user manual.
- Width: 110 mm (4.33 in)
- Length: 165 mm (6.5 in)
- Installation depth: 138.3 mm (5.44 in)
- Weight: 1.8 kg (3.969 lb)
Mounting / Installation
- Tightening torque: 2-3 N·m (17.7 ... 26.6 lbf-in)
- Tightening torque auxiliary contact: 0.4–0.6 N·m (3.5 ... 5.3 lbf in)
Technical Diagrams
Trip Time Characteristic
A graph shows the trip time characteristic for type B, for AC and DC, indicating the time in seconds and minutes against the current multiple of the rated current. The characteristic is shown for a cold state limit.
Measurement Diagram
Diagrams illustrate the dimensions of the circuit breaker in millimeters and inches. The main unit is 8530/1, designed for 4 division units. Key dimensions include width (110 mm / 4.33 in), length (165 mm / 6.50 in), and installation depth (138.3 mm / 5.44 in).
Accessories
- Cylinder lock: For locking (shackle Ø 3), Part No. 107115
- Quadruple immobilization device: Locking/tagging tongs for individual component locking using up to 4 cylinder locks, Part No. 227232
- Fixing kit: A fixing set for mounting the component on the mounting plate without a top-hat rail, Part No. 276618
R. STAHL reserves the right to modify technical data, dimensions, weights, constructions, and delivery options.