Proscenic P11 Smart Cordless Vacuum Cleaner
All dust blown away.
Please read this manual carefully before use. The company reserves the right to interpret the instructions. The appearance of the product is subject to change without notice. After reading, please keep it together with the invoice. In case of product technology or software upgrade, without notice. This product is only suitable for sale and use in Europe and America.
Activate Your Quality Life.
Proscenic Technology Co., Ltd.
Service support
Web: www.proscenic.com
E-mail: support@proscenic.com
Precautions
Please read all contents of this manual carefully before using this product.
- Please do not use the vacuum cleaner to vacuum detergents, kerosene, broken glasses, needles, soot, wet items, sewage, matches, etc.
- Please do not use the vacuum cleaner to vacuum cement, plaster, building materials etc., or toy balls and other large objects, as these can cause failures such as the vacuum cleaner being blocked, the motor burning out, etc.
- Please keep the vacuum cleaner away from fires and places with high temperatures.
- When using the vacuum cleaner, please make sure to install the filter module and the roller brush of the floor brush.
- When using the vacuum cleaner, please be sure not to block the suction inlet or block the rotation of the brush roller, as this may cause motor failure.
- Please do not pour or splash water or other liquids into the machine, so as to avoid short circuits and burning out the electronics.
- When using a new battery, or for the first time after long-term storage, please fully charge the battery. If the machine is not going to be used for a long time, please make sure to charge and discharge the battery at least once every three months.
- When your vacuum cleaner is fully charged and needs to be cleaned or serviced, unplug the charger promptly and do not pull it by the power cord.
- When cleaning the vacuum cleaner, use a dry cloth to wipe it, do not use gasoline, thinners or other cleaners as they may damage the walls or cause discoloration.
- Please do not use or store the vacuum cleaner in extreme conditions such as very high or low temperatures. It is recommended to use the vacuum cleaner indoors at ambient temperatures between 0 and 40°C. Please store it in a cool and dry place, and do not expose it to sunlight for a long time.
- Do not allow children to use or play with the machine.
- If the machine does not work when it's fully charged, it must be inspected and repaired at a designated service centre. Do not disassemble the machine without permission.
- Old battery packs should be recycled safely and not be discarded into the normal garbage.
- If the power cord is damaged, in order to avoid any danger, it must be replaced by a professional from the manufacturer's local service department or a similar service centre.
- After use, it is necessary to put it back on the wall or hanger to avoid accidents or injuries.
What's in the Box
- 1 x Metal Extension Tube: A long, slender metallic tube.
- 1 x Main Body: The primary unit of the vacuum cleaner, housing the motor and dustbin.
- 1 x Electric Floor Brush: A brush head designed for floor cleaning, likely with a motorized roller.
- 1 x Power Adapter: A device to charge the vacuum cleaner.
- 1 x Round Dusting Brush: A smaller, circular brush attachment.
- 1 x Wall-mounted Charging Stand Installation Kit: Components for mounting the charging dock on a wall.
- 1 x User Manual: This document.
- 1 x Crevice Brush: A narrow brush attachment for tight spaces.
- 1 x Cleaning Tool: A tool for cleaning the vacuum cleaner itself.
- 1 x Mini-Motorized Tool: A smaller motorized brush attachment, suitable for upholstery.
Product Overview
The main body of the vacuum cleaner includes the following components:
- Main Body: The central unit.
- LED Touch Screen: Interface for controlling the device.
- Exhaust Grids: Vents for air expulsion.
- Handle: For gripping and maneuvering the vacuum.
- Power Switch: Button to turn the device on/off.
- Dust Container: Where collected debris is stored.
- Filter Assembly: Contains filters for air purification.
- Dust Container Cover Buckle: Latch for securing the dust container.
- Dust Container Cover: The lid of the dust container.
- Joint Button for the Main Unit: Button to detach accessories from the main unit.
- Battery Release Button: Mechanism to remove the battery.
- Removable Battery: The power source, which can be detached.
- Dust Container Release Button: Button to detach the dust container.
- Tip Holder: A place to rest the vacuum or attach accessories.
- Metal Extension Tube: Connects the main body to the floor brush or other attachments.
- Joint Button for the Electric Brush: Button to detach the electric floor brush.
- Electric Floor Brush: The main floor cleaning head.
- LED Light: Indicator light, possibly for power or status.
Note:
- Wash filters with cold water regularly. Ensure the filters are completely dry before refitting.
- Your vacuum cleaner is designed to be used regularly. Regular use may cause build-up around brushes and HEPA filter. We recommend performing regular maintenance to keep your vacuum cleaner running at optimal.
Accessory Installation
Step 1: Diagrams show connecting the main body to the extension tube, and then attaching different brush heads or tools to the tube or directly to the main body. This involves aligning connectors and pushing until they click.
Step 2: Further diagrams illustrate connecting various accessories, likely showing different configurations for floor cleaning or handheld use.
Wall-mounted Charging Stand Installation
Method 1: Sticker Installation
Step 1: Apply a sticker to the wall as a guide.
Step 2: Align the charging stand with the sticker and secure it.
Step 3: A diagram shows the stand mounted at a 90-degree angle to the wall.
Method 2: Screw Installation
- Drill 3 screws according to the hole position of the alignment sticker.
- Insert the plastic expansion tube into the screw hole.
- Align the hanger with the screw holes, and then install and tighten the screws.
Main Body Charging
DC port charging
A diagram shows the vacuum cleaner's DC charging port and a separate battery pack being charged. The indicator light shows:
- Red: Charging
- Green: Fully Charged
Wall-mounted charging dock charging
When the battery gets low, the first bar of the power indicator light flashes white, indicating the need to charge. If the power is too low, the machine will automatically shut down. The first bar of the power indicator light will flash white. Charge the battery or replace it with a fully charged battery.
Battery status indicators on the charging dock:
- Fully Charged: All bars are illuminated.
- Charging: Some bars are illuminated, indicating charging progress.
- Low Battery: The first bar flashes white.
Note:
- This machine can only be charged with the original power adapter.
- The machine cannot be operated and the power switch does not work during the process of charging.
Product Usage
Usage of the main body
Power on/off: Press the Power On/Off button to start the machine; press again to stop the machine.
There are 3 levels of suction power: ECO mode, AUTO mode, and MAX mode. Adjust power levels by pressing the suction level indicator icon ( depicted as '88' ) on the display panel at the end of the main body.
Note: The power switch is a push button that requires a single tap to turn on/off.
Note: To achieve the best cleaning effect, the vacuum cleaner will automatically switch to the strong gear for 3 seconds after the power-off button is pressed. This is a normal phenomenon.
Usage of attachments
Attach the required suction nozzle into the holder. The metal extension tube can be added depending on the actual situation.
Usage of the electric floor brush
The electric floor brush can be used to clean hard floors, floor tiles, or short-haired carpets. Using a metal extension tube is recommended for a better experience.
Usage of Other Tools
Usage of the electric mini motorized tool
The mini motorized tool can be used to clean sofas, mattresses, cribs, etc.
Usage of the crevice brush
The crevice brush is used to clean hard-to-reach spots, such as ceilings, bookshelves, keyboards, and narrow gaps.
Usage of the round dusting brush
- Connect the round dusting brush directly to the main unit. It can be used to clean desktops, cabinets, sofas, low pile carpets, and so on.
- The metal extension tube can be attached to the round dusting brush for cleaning high places such as ceilings and curtains.
Disassembly and Maintenance
Remove the dust container
Step 1: Press the release buttons on both sides of the dust container simultaneously. Then, pull the dust container to remove it.
Clean the filter assembly
Diagrams show the dust container and filter assembly being disassembled into individual components. The HEPA filter and sponge filter can be washed with cold water. Ensure the filters are completely dry before refitting. Do not expose them to the sun.
Installation of filter components
- Keep the air guiding block of the stainless steel filter assembly on the same side as the dust container inlet. Install the stainless steel filter assembly into the dust container from the top. Ensure the limit slot is aligned with the dust container limit bar.
- Put the filter sponge into the bottom of the HEPA cover. The filter sponge needs to be fixed with 5 slots completely; otherwise, it will affect the filtering effect.
- Keep the side of the HEPA assembly with the rope upward and put it into the dust container from the top. Ensure the limit slot of the HEPA assembly is aligned with the dust container's limit bar.
Installation of the dust container
- Snap the dust container into the main unit. Ensure the snap is in place.
- Push the bottom of the dust container in the direction shown in the picture until you hear a click.
Floor Brush and Roller Brush Maintenance
Diagrams show the process of removing and attaching the roller brush to the floor brush head.
Battery disassembly
- Remove the battery: Press the battery release buttons on both sides simultaneously, then grab and pull the battery at the same time to take it out.
- Install the battery: Align the battery slot with the card slot, press the bottom to slide into the battery slot until it snaps tightly.
Battery Information
- Battery Type: Li-ion battery.
- Dispose of the battery in accordance with local ordinances or regulations.
- Do not use non-rechargeable batteries.
- In the unlikely event that liquid leaks from the battery, do not allow the liquid to come in contact with skin or eyes. Place the battery in a sealed plastic bag and dispose of safely according to local environmental regulations.
Troubleshooting
Fault scenarios | Causes | Solutions |
---|---|---|
The machine does not work | Battery is not installed | Please install the battery correctly. |
Battery is flat | Charge the battery. | |
Suction diminishes | The dust container and the HEPA filter are not installed well | Install the dust container and HEPA filter correctly. |
The HEPA filter is used for a long time | Replace the HEPA filter. | |
The dust container is full of dust | Empty the dust container. | |
Blockages occur in the hose, accessories, and inlet openings. | Check and clear any blockage. | |
Charging indicator does not light up while charging | The charging terminal is not fully inserted into the DC terminal | Insert the charging terminal completely into the charging port. |
Insufficient use time | Insufficient charging time | Fully charge the battery according to the instructions in the charging section. |
Battery aging | The battery needs to be replaced at a designated service center. | |
Rolling brush stops | Oversized foreign bodies are sucked up | Clean the roller brush and restart the machine. |
The roller brush is entangled by an excessive amount of fiber | Clear the windings of the floor brush. | |
Error code: [Floor brush blocked] | The floor brush is blocked | Ensure that the floor brush and metal extension tube are assembled firmly. |
Error code: [Short circuit] | Short circuit of the floor brush | Please contact Proscenic Customer Service to replace the floor brush. |
Error code: [Fan abnormal] | The fan is abnormal | Check if the suction port is blocked and clean up the blockage. |
The air outlet is hot | The filter assembly is blocked | If the machine is hot, turn it off and wait for a while. Clean the dust container and the HEPA filter. |