Secop BD80F 12/24V DC PM Single Pack Compressor
Codice Imballo Singolo: 195B4790
Product Overview
The Secop BD80F is a direct current compressor designed for 12/24V DC applications, compatible with R134a and R1234yf refrigerants. It is available in a single pack configuration.
Posizione | Titolo | Codice | Quantità |
---|---|---|---|
1 | Compressor BD80F | 101Z0280 | 1 |
2 | Electronic unit High Speed | 101N0391 | 1 |
3 | Snap-on in quantities | ø7,3 | ø16mm | 118-1919 | 1 |
General Specifications
- Code number (without electronic units): 101Z0280
- Electronic unit - High Speed: 101N0390, 30 pcs: 101N0391
- Compressors on pallet: 150
Application
- Evaporating temperature: LBP (-30 to -5 °C)
- Voltage/max. voltage: 9.6-17 / 21.3 - 31.5 VDC
- Max. condensing temperature continuous (short): 60 °C (70 °C)
- Max. winding temperature continuous (short): 125 °C (135 °C)
Cooling requirements
Application | LBP | MBP | HBP | SG |
---|---|---|---|---|
32°C | S | - | - | S |
38°C | - | S | - | - |
43°C | - | - | S | - |
Remarks on application: SG = Suction gas cooling normally sufficient; S = not applicable in this area.
Motor Specifications
- Motor type: variable speed
- Resistance, all 3 windings (25°C): 1.8 Ω
Design Specifications
- Displacement: 3.00 cm³
- Oil quantity (type): 150 cm³ (polyolester)
- Maximum refrigerant charge: 300 g
- Free gas volume in compressor: 870 cm³
- Weight - Compressor/Electronic unit: 4.4/0.32 kg
Standard Battery Protection Settings
12V | 24V | |
---|---|---|
Voltage | 12 VDC | 24 VDC |
Cut out | 10.4 VDC | 22.8 VDC |
Cut in | 11.7 VDC | 24.2 VDC |
Dimensions
Height: 137 mm (A)
Width: 135 mm (B)
Depth: 128 mm (B1), 73 mm (B2)
Suction connector: location/I.D. mm | angle C 6.2 | 40°, material: Cu-plated steel | Al cap
Process connector: location/I.D. mm | angle D 6.2 | 45°, material: Cu-plated steel | Al cap
Discharge connector: location/I.D. mm | angle E 5.0 | 21°, material: Cu-plated steel | Al cap
Connector tolerance: ±0.09, on 5.0 +0.12/+0.20 mm
Performance Data with Refrigerant R134a
Capacity (EN 12900 Household/CECOMAF)
rpm \ °C | 24V DC, static cooling watt | Compressor speed | Resistor (R1) [Ω] | Motor speed [rpm] | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
-30 | -25 | -23.3 | -20 | -15 | -10 | -5 | 0 | 5 | 7.2 | 10 | 15 | ||||
2,500 | 35.2 | 49.8 | 55.3 | 67.0 | 87.3 | 112 | 140 | - | - | - | - | - | 0 | - | - |
3,100 | 41.9 | 59.2 | 65.8 | 79.8 | 104 | 133 | 168 | - | - | - | - | - | ΑΕΟ | - | - |
3,800 | 50.1 | 70.8 | 78.7 | 95.4 | 125 | 159 | 200 | - | - | - | - | - | 203 | - | - |
4,400 | 54.9 | 78.1 | 86.8 | 105 | 138 | 176 | 221 | - | - | - | - | - | 451 | - | - |
Capacity (ASHRAE LBP)
rpm \ °C | 24V DC, static cooling watt | Compressor speed | Resistor (R1) [Ω] | Motor speed [rpm] | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
-30 | -25 | -23.3 | -20 | -15 | -10 | -5 | 0 | 5 | 7.2 | 10 | 15 | ||||
2,500 | 43.7 | 61.8 | 68.6 | 83.1 | 108 | 138 | 174 | - | - | - | - | - | 0 | - | - |
3,100 | 52.0 | 73.4 | 81.6 | 98.8 | 129 | 165 | 208 | - | - | - | - | - | ΑΕΟ | - | - |
3,800 | 62.1 | 87.8 | 97.5 | 118 | 154 | 197 | 248 | - | - | - | - | - | 867 | - | - |
4,400 | 68.1 | 96.7 | 108 | 130 | 171 | 218 | 274 | - | - | - | - | - | 4,400 | - | - |
Power consumption
rpm \ °C | 24V DC, static cooling watt | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
-30 | -25 | -23.3 | -20 | -15 | -10 | -5 | 0 | 5 | 7.2 | 10 | 15 | |
2,500 | 38.4 | 47.9 | 51.2 | 57.8 | 68.2 | 79.5 | 91.9 | - | - | - | - | - |
3,100 | 46.9 | 58.9 | 62.9 | 70.8 | 83.4 | 97.3 | 113 | - | - | - | - | - |
3,800 | 57.5 | 72.0 | 76.9 | 86.5 | 102 | 119 | 139 | - | - | - | - | - |
4,400 | 66.3 | 83.5 | 89.2 | 100 | 118 | 138 | 161 | - | - | - | - | - |
Note: In AEO (Adaptive Energy Optimizing) speed mode, the BD compressor will always adapt its speed to the actual cooling demand.
Current consumption (for 12V applications the following must be doubled)
rpm \ °C | 24V DC, static cooling | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
-30 | -25 | -23.3 | -20 | -15 | -10 | -5 | 0 | 5 | 7.2 | 10 | 15 | |
2,500 | 1.6 | 2.0 | 2.1 | 2.4 | 2.8 | 3.3 | 3.8 | - | - | - | - | - |
3,100 | 1.9 | 2.4 | 2.6 | 3.0 | 3.5 | 4.1 | 4.7 | - | - | - | - | - |
3,800 | 2.4 | 3.0 | 3.2 | 3.6 | 4.3 | 5.0 | 5.8 | - | - | - | - | - |
4,400 | 2.8 | 3.5 | 3.7 | 4.2 | 4.9 | 5.8 | 6.7 | - | - | - | - | - |
COP (EN 12900 Household/CECOMAF)
rpm \ °C | 24V DC, static cooling | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
-30 | -25 | -23.3 | -20 | -15 | -10 | -5 | 0 | 5 | 7.2 | 10 | 15 | |
2,500 | 0.92 | 1.04 | 1.08 | 1.16 | 1.28 | 1.40 | 1.53 | - | - | - | - | - |
3,100 | 0.89 | 1.01 | 1.05 | 1.13 | 1.25 | 1.37 | 1.48 | - | - | - | - | - |
3,800 | 0.87 | 0.98 | 1.02 | 1.10 | 1.22 | 1.34 | 1.44 | - | - | - | - | - |
4,400 | 0.83 | 0.94 | 0.97 | 1.05 | 1.16 | 1.27 | 1.37 | - | - | - | - | - |
COP (ASHRAE LBP)
rpm \ °C | 24V DC, static cooling | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
-30 | -25 | -23.3 | -20 | -15 | -10 | -5 | 0 | 5 | 7.2 | 10 | 15 | |
2,500 | 1.14 | 1.29 | 1.34 | 1.44 | 1.63 | 1.78 | 1.93 | - | - | - | - | - |
3,100 | 1.10 | 1.25 | 1.30 | 1.40 | 1.55 | 1.70 | 1.85 | - | - | - | - | - |
3,800 | 1.07 | 1.22 | 1.27 | 1.37 | 1.52 | 1.66 | 1.80 | - | - | - | - | - |
4,400 | 1.02 | 1.16 | 1.21 | 1.30 | 1.45 | 1.58 | 1.71 | - | - | - | - | - |
Test conditions
- Condensing temperature: EN 12900/CECOMAF: 55°C; ASHRAE LBP: 54.4°C
- Ambient temperature: 32°C (for both)
- Suction gas temperature: 32°C (for both)
- Liquid temperature: no subcooling (for both)
Accessories for BD80F
- Bolt joint for one comp.: Ø:16 mm, Code: 118-1917
- Bolt joint in quantities: Ø:16 mm, Code: 118-1918
- Snap-on in quantities: Ø:16 mm, Code: 118-1919
- Remote kit (without cable): 105N9210
- Secop Gateway: 105N9518
Wiring Diagram
The diagram shows the connections for power supply, Secop Gateway, and optional components like a mechanical thermostat or NTC resistor. It includes spade connectors, a fuse, main switch, and terminal plug.
Key components:
- Power supply
- Secop Gateway (connected to LÍN and C)
- Interface (connected to D/I and C for TOOL4COOL® or display)
- Optional components: NTC resistor, mechanical thermostat
- R1 = speed selection, R2 = battery protection I
Performance Data with Refrigerant R1234yf
Capacity (EN 12900 Household/CECOMAF)
rpm \ °C | 24V DC, static cooling watt | Compressor speed | Resistor (R1) [Ω] | Motor speed [rpm] | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
-30 | -25 | -23.3 | -20 | -15 | -10 | -5 | 0 | 5 | 7.2 | 10 | 15 | ||||
2,500 | 37.2 | 51.7 | 57.3 | 69.0 | 89.2 | 113 | 139 | - | - | - | - | - | 0 | - | - |
3,100 | 42.6 | 59.9 | 66.8 | 81.7 | 108 | 137 | 170 | - | - | - | - | - | ΑΕΟ | - | - |
3,800 | 46.9 | 66.0 | 74.3 | 92.5 | 125 | 161 | 200 | - | - | - | - | - | 203 | - | - |
4,400 | 57.5 | 76.5 | 84.3 | 101 | 132 | 168 | 211 | - | - | - | - | - | 451 | - | - |
Capacity (ASHRAE LBP)
rpm \ °C | 24V DC, static cooling watt | Compressor speed | Resistor (R1) [Ω] | Motor speed [rpm] | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
-30 | -25 | -23.3 | -20 | -15 | -10 | -5 | 0 | 5 | 7.2 | 10 | 15 | ||||
2,500 | 48.1 | 66.8 | 74.0 | 89.1 | 115 | 146 | 180 | - | - | - | - | - | 0 | - | - |
3,100 | 54.9 | 77.0 | 86.0 | 105 | 139 | 177 | 220 | - | - | - | - | - | ΑΕΟ | - | - |
3,800 | 60.2 | 84.7 | 95.3 | 119 | 160 | 207 | 257 | - | - | - | - | - | 867 | - | - |
4,400 | 73.7 | 98.7 | 109 | 131 | 171 | 218 | 273 | - | - | - | - | - | 4,400 | - | - |
Power consumption
rpm \ °C | 24V DC, static cooling watt | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
-30 | -25 | -23.3 | -20 | -15 | -10 | -5 | 0 | 5 | 7.2 | 10 | 15 | |
2,500 | 42.6 | 51.5 | 54.6 | 60.9 | 70.9 | 81.7 | 93.2 | - | - | - | - | - |
3,100 | 50.0 | 60.3 | 64.2 | 72.1 | 85.4 | 100 | 116 | - | - | - | - | - |
3,800 | 59.6 | 71.3 | 75.9 | 85.9 | 103 | 123 | 144 | - | - | - | - | - |
4,400 | 71.0 | 84.8 | 90.2 | 101 | 121 | 142 | 166 | - | - | - | - | - |
Current consumption (for 12V applications the following must be doubled)
rpm \ °C | 24V DC, static cooling | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
-30 | -25 | -23.3 | -20 | -15 | -10 | -5 | 0 | 5 | 7.2 | 10 | 15 | |
2,500 | 1.8 | 2.1 | 2.3 | 2.5 | 3.0 | 3.6 | 4.2 | - | - | - | - | - |
3,100 | 2.1 | 2.5 | 2.7 | 3.0 | 3.6 | 4.2 | 4.8 | - | - | - | - | - |
3,800 | 2.5 | 3.0 | 3.2 | 3.6 | 4.3 | 5.1 | 6.0 | - | - | - | - | - |
4,400 | 3.0 | 3.5 | 3.8 | 4.2 | 5.0 | 5.9 | 6.9 | - | - | - | - | - |
COP (EN 12900 Household/CECOMAF)
rpm \ °C | 24V DC, static cooling | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
-30 | -25 | -23.3 | -20 | -15 | -10 | -5 | 0 | 5 | 7.2 | 10 | 15 | |
2,500 | 0.87 | 1.00 | 1.05 | 1.13 | 1.25 | 1.37 | 1.48 | - | - | - | - | - |
3,100 | 0.85 | 0.99 | 1.04 | 1.13 | 1.25 | 1.36 | 1.45 | - | - | - | - | - |
3,800 | 0.79 | 0.92 | 0.97 | 1.07 | 1.20 | 1.31 | 1.38 | - | - | - | - | - |
4,400 | 0.81 | 0.90 | 0.93 | 1.00 | 1.09 | 1.18 | 1.26 | - | - | - | - | - |
COP (ASHRAE LBP)
rpm \ °C | 24V DC, static cooling | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
-30 | -25 | -23.3 | -20 | -15 | -10 | -5 | 0 | 5 | 7.2 | 10 | 15 | |
2,500 | 1.13 | 1.30 | 1.35 | 1.46 | 1.63 | 1.78 | 1.93 | - | - | - | - | - |
3,100 | 1.10 | 1.28 | 1.34 | 1.46 | 1.62 | 1.77 | 1.89 | - | - | - | - | - |
3,800 | 1.01 | 1.19 | 1.26 | 1.38 | 1.55 | 1.69 | 1.79 | - | - | - | - | - |
4,400 | 1.04 | 1.16 | 1.21 | 1.29 | 1.42 | 1.54 | 1.65 | - | - | - | - | - |
Test conditions
- Condensing temperature: EN 12900/CECOMAF: 55°C; ASHRAE LBP: 54.4°C
- Ambient temperature: 32°C (for both)
- Suction gas temperature: 32°C (for both)
- Liquid temperature: no subcooling (for both)
Accessories for BD80F
- Bolt joint for one comp.: Ø:16 mm, Code: 118-1917
- Bolt joint in quantities: Ø:16 mm, Code: 118-1918
- Snap-on in quantities: Ø:16 mm, Code: 118-1919
- Remote kit (without cable): 105N9210
- Secop Gateway: 105N9518
Operational Errors
Error code | Error type |
---|---|
6 | Thermostat failure (If the NTC thermistor is short-circuit or has no connection). |
5 | Thermal cut-out of electronic unit (If the refrigeration system has been too heavily loaded, or if the ambient temperature is high, the electronic unit will run too hot). |
4 | Minimum motor speed error (If the refrigeration system is too heavily loaded, the motor cannot maintain minimum speed at approximately 1,850 rpm). |
3 | Motor start error (The rotor is blocked or the differential pressure in the refrigeration system is too high (>5 bar)). |
2 | Too many start attempts or fan over current (Too many compressor or fan starts in short time or fan current higher than 0.5A avg). |
1 | Battery protection cut-out (The voltage is outside the cut-out setting). |
Service and Repair Information
Instructions for Electronic Units are available for download on www.secop.com.
Service/Repair Precautions:
- Avoid excessive heat during brazing. Maximum temperature at socket is 150°C/302°F.
- Do not heat the discharge connector directly.
- Limit brazing to 10 seconds and allow 5 minutes for cooling between attempts.
Refrigerant Handling:
The compressors are designed for specific refrigerants:
- R290
- R600a
- R170
- R1234yf
Compressor Types:
- BD Nano
- BD Micro
- BD P-Housing
- BD T-Housing
Secop GmbH. Lise-Meitner-Straße 29 • 24941 Flensburg, Germany • Tel: +49 46149410 • www.secop.com
Secop does not assume responsibility for possible errors in catalogs, brochures, and other printed material. Secop reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary to specifications already agreed. All trademarks in this material are the property of the respective companies. Secop and the Secop logotype are trademarks of Secop GmbH. All rights reserved.