Secop BD80F 12/24V DC PM Single Pack Compressor

Codice Imballo Singolo: 195B4790

Product Overview

The Secop BD80F is a direct current compressor designed for 12/24V DC applications, compatible with R134a and R1234yf refrigerants. It is available in a single pack configuration.

Posizione Titolo Codice Quantità
1 Compressor BD80F 101Z0280 1
2 Electronic unit High Speed 101N0391 1
3 Snap-on in quantities | ø7,3 | ø16mm 118-1919 1

General Specifications

Application

Cooling requirements

Application LBP MBP HBP SG
32°C S - - S
38°C - S - -
43°C - - S -

Remarks on application: SG = Suction gas cooling normally sufficient; S = not applicable in this area.

Motor Specifications

Design Specifications

Standard Battery Protection Settings

12V 24V
Voltage 12 VDC 24 VDC
Cut out 10.4 VDC 22.8 VDC
Cut in 11.7 VDC 24.2 VDC

Dimensions

Height: 137 mm (A)

Width: 135 mm (B)

Depth: 128 mm (B1), 73 mm (B2)

Suction connector: location/I.D. mm | angle C 6.2 | 40°, material: Cu-plated steel | Al cap

Process connector: location/I.D. mm | angle D 6.2 | 45°, material: Cu-plated steel | Al cap

Discharge connector: location/I.D. mm | angle E 5.0 | 21°, material: Cu-plated steel | Al cap

Connector tolerance: ±0.09, on 5.0 +0.12/+0.20 mm

Performance Data with Refrigerant R134a

Capacity (EN 12900 Household/CECOMAF)

rpm \ °C 24V DC, static cooling watt Compressor speed Resistor (R1) [Ω] Motor speed [rpm]
-30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15
2,500 35.2 49.8 55.3 67.0 87.3 112 140 - - - - - 0 - -
3,100 41.9 59.2 65.8 79.8 104 133 168 - - - - - ΑΕΟ - -
3,800 50.1 70.8 78.7 95.4 125 159 200 - - - - - 203 - -
4,400 54.9 78.1 86.8 105 138 176 221 - - - - - 451 - -

Capacity (ASHRAE LBP)

rpm \ °C 24V DC, static cooling watt Compressor speed Resistor (R1) [Ω] Motor speed [rpm]
-30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15
2,500 43.7 61.8 68.6 83.1 108 138 174 - - - - - 0 - -
3,100 52.0 73.4 81.6 98.8 129 165 208 - - - - - ΑΕΟ - -
3,800 62.1 87.8 97.5 118 154 197 248 - - - - - 867 - -
4,400 68.1 96.7 108 130 171 218 274 - - - - - 4,400 - -

Power consumption

rpm \ °C 24V DC, static cooling watt
-30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15
2,500 38.4 47.9 51.2 57.8 68.2 79.5 91.9 - - - - -
3,100 46.9 58.9 62.9 70.8 83.4 97.3 113 - - - - -
3,800 57.5 72.0 76.9 86.5 102 119 139 - - - - -
4,400 66.3 83.5 89.2 100 118 138 161 - - - - -

Note: In AEO (Adaptive Energy Optimizing) speed mode, the BD compressor will always adapt its speed to the actual cooling demand.

Current consumption (for 12V applications the following must be doubled)

rpm \ °C 24V DC, static cooling
-30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15
2,500 1.6 2.0 2.1 2.4 2.8 3.3 3.8 - - - - -
3,100 1.9 2.4 2.6 3.0 3.5 4.1 4.7 - - - - -
3,800 2.4 3.0 3.2 3.6 4.3 5.0 5.8 - - - - -
4,400 2.8 3.5 3.7 4.2 4.9 5.8 6.7 - - - - -

COP (EN 12900 Household/CECOMAF)

rpm \ °C 24V DC, static cooling
-30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15
2,500 0.92 1.04 1.08 1.16 1.28 1.40 1.53 - - - - -
3,100 0.89 1.01 1.05 1.13 1.25 1.37 1.48 - - - - -
3,800 0.87 0.98 1.02 1.10 1.22 1.34 1.44 - - - - -
4,400 0.83 0.94 0.97 1.05 1.16 1.27 1.37 - - - - -

COP (ASHRAE LBP)

rpm \ °C 24V DC, static cooling
-30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15
2,500 1.14 1.29 1.34 1.44 1.63 1.78 1.93 - - - - -
3,100 1.10 1.25 1.30 1.40 1.55 1.70 1.85 - - - - -
3,800 1.07 1.22 1.27 1.37 1.52 1.66 1.80 - - - - -
4,400 1.02 1.16 1.21 1.30 1.45 1.58 1.71 - - - - -

Test conditions

Accessories for BD80F

Wiring Diagram

The diagram shows the connections for power supply, Secop Gateway, and optional components like a mechanical thermostat or NTC resistor. It includes spade connectors, a fuse, main switch, and terminal plug.

Key components:

Performance Data with Refrigerant R1234yf

Capacity (EN 12900 Household/CECOMAF)

rpm \ °C 24V DC, static cooling watt Compressor speed Resistor (R1) [Ω] Motor speed [rpm]
-30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15
2,500 37.2 51.7 57.3 69.0 89.2 113 139 - - - - - 0 - -
3,100 42.6 59.9 66.8 81.7 108 137 170 - - - - - ΑΕΟ - -
3,800 46.9 66.0 74.3 92.5 125 161 200 - - - - - 203 - -
4,400 57.5 76.5 84.3 101 132 168 211 - - - - - 451 - -

Capacity (ASHRAE LBP)

rpm \ °C 24V DC, static cooling watt Compressor speed Resistor (R1) [Ω] Motor speed [rpm]
-30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15
2,500 48.1 66.8 74.0 89.1 115 146 180 - - - - - 0 - -
3,100 54.9 77.0 86.0 105 139 177 220 - - - - - ΑΕΟ - -
3,800 60.2 84.7 95.3 119 160 207 257 - - - - - 867 - -
4,400 73.7 98.7 109 131 171 218 273 - - - - - 4,400 - -

Power consumption

rpm \ °C 24V DC, static cooling watt
-30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15
2,500 42.6 51.5 54.6 60.9 70.9 81.7 93.2 - - - - -
3,100 50.0 60.3 64.2 72.1 85.4 100 116 - - - - -
3,800 59.6 71.3 75.9 85.9 103 123 144 - - - - -
4,400 71.0 84.8 90.2 101 121 142 166 - - - - -

Current consumption (for 12V applications the following must be doubled)

rpm \ °C 24V DC, static cooling
-30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15
2,500 1.8 2.1 2.3 2.5 3.0 3.6 4.2 - - - - -
3,100 2.1 2.5 2.7 3.0 3.6 4.2 4.8 - - - - -
3,800 2.5 3.0 3.2 3.6 4.3 5.1 6.0 - - - - -
4,400 3.0 3.5 3.8 4.2 5.0 5.9 6.9 - - - - -

COP (EN 12900 Household/CECOMAF)

rpm \ °C 24V DC, static cooling
-30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15
2,500 0.87 1.00 1.05 1.13 1.25 1.37 1.48 - - - - -
3,100 0.85 0.99 1.04 1.13 1.25 1.36 1.45 - - - - -
3,800 0.79 0.92 0.97 1.07 1.20 1.31 1.38 - - - - -
4,400 0.81 0.90 0.93 1.00 1.09 1.18 1.26 - - - - -

COP (ASHRAE LBP)

rpm \ °C 24V DC, static cooling
-30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15
2,500 1.13 1.30 1.35 1.46 1.63 1.78 1.93 - - - - -
3,100 1.10 1.28 1.34 1.46 1.62 1.77 1.89 - - - - -
3,800 1.01 1.19 1.26 1.38 1.55 1.69 1.79 - - - - -
4,400 1.04 1.16 1.21 1.29 1.42 1.54 1.65 - - - - -

Test conditions

Accessories for BD80F

Operational Errors

Error code Error type
6 Thermostat failure (If the NTC thermistor is short-circuit or has no connection).
5 Thermal cut-out of electronic unit (If the refrigeration system has been too heavily loaded, or if the ambient temperature is high, the electronic unit will run too hot).
4 Minimum motor speed error (If the refrigeration system is too heavily loaded, the motor cannot maintain minimum speed at approximately 1,850 rpm).
3 Motor start error (The rotor is blocked or the differential pressure in the refrigeration system is too high (>5 bar)).
2 Too many start attempts or fan over current (Too many compressor or fan starts in short time or fan current higher than 0.5A avg).
1 Battery protection cut-out (The voltage is outside the cut-out setting).

Service and Repair Information

Instructions for Electronic Units are available for download on www.secop.com.

Service/Repair Precautions:

Refrigerant Handling:

The compressors are designed for specific refrigerants:

Compressor Types:

Secop GmbH. Lise-Meitner-Straße 29 • 24941 Flensburg, Germany • Tel: +49 46149410 • www.secop.com

Secop does not assume responsibility for possible errors in catalogs, brochures, and other printed material. Secop reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary to specifications already agreed. All trademarks in this material are the property of the respective companies. Secop and the Secop logotype are trademarks of Secop GmbH. All rights reserved.

PDF preview unavailable. Download the PDF instead.

single-pack-195B4790 GPL Ghostscript 10.00.0 Adobe InDesign 17.4 (Windows)

Related Documents

Preview Secop BD35F 12/24V DC PM Compressor Specifications and Performance Data
Detailed technical specifications, performance data, and application information for the Secop BD35F 12/24V DC PM compressor, including electrical requirements, cooling performance, and operational error codes.
Preview Secop BD50F Compressor: Technical Specifications and Performance Data
Detailed technical specifications, performance data, and application information for the Secop BD50F compressor, including 12/24V DC and 100-240V AC models. Covers cooling requirements, motor details, dimensions, and electrical connections.
Preview Secop BD80F 12/24V DC PM Compressor Technical Data
Technical specifications, performance data, and operational information for the Secop BD80F 12/24V DC PM compressor, including details on refrigerants R134a and R1234yf, power consumption, and wiring diagrams.
Preview Secop BD80F 12/24V DC PM Compressor Technical Specifications and Performance Data
Detailed technical specifications, performance data, and operational information for the Secop BD80F 12/24V DC PM compressor, compatible with R134a and R1234yf refrigerants.
Preview Secop Mounting Accessories - Types of Packaging and Parts List
A product bulletin from Secop detailing mounting accessories, including types of packaging, part codes, dimensions, and associated compressor series. It also provides a parts list with diagrams for common mounting configurations.
Preview Secop DC-Powered Compressors for Mobile Cooling
Secop offers advanced DC-powered compressors for mobile cooling applications, including 12V, 24V, and 48V DC models. These compressors are designed for stability, reliability, and efficiency in various mobile environments such as vehicles, boats, and portable units. The product line includes models like BD Nano, BD Micro, and various BD series compressors, utilizing refrigerants like R134a, R1234yf, R600a, and R290. Secop provides solutions for stationary, mobile, and medical cooling needs.
Preview Secop BDN45F-A DC Compressor R134a, R1234yf 12/24V Technical Data
Technical specifications and performance data for the Secop BDN45F-A Direct Current Compressor, compatible with R134a and R1234yf refrigerants, operating on 12/24V DC. Includes performance tables, electrical specifications, dimensions, and brazing instructions.
Preview Secop BDN45F Direct Current Compressor - Technical Data Sheet
Technical specifications, performance data, and application information for the Secop BDN45F direct current compressor, compatible with R134a and R1234yf refrigerants for 12/24V DC systems.