Secop BD80F 12/24V DC PM Compressor

Single Pack Catalog Number: 195B4141

General Information

Position Title Code Quantity
1 Compressor BD80F 101Z0280 1
2 Electronic unit High Speed 101N0390 1
3 Bolt joint for one compressor | M6 | ø16mm 118-1917 1

Product Overview

Model: BD80F Direct Current Compressor

Refrigerants: R134a, R1234yf

Voltage: 12/24V DC

Key Features:

Application Details

Application:

Cooling requirements:

Application LBP MBP HBP SG
32°C S - - S
38°C S S - -
43°C S S S -

Remarks on application: S = Static cooling normally sufficient; O = Oil cooling; F1 = Fan cooling 1.5 m/s; F2 = Fan cooling 3.0 m/s necessary; SG = Suction gas cooling normally sufficient; - = not applicable in this area.

Motor Specifications

Design Specifications

Dimensions

Dimension Value (mm) Angle
A (Height) 137 -
B 135 -
B1 128 -
B2 73 -
C (Suction connector) 6.2 40°
D (Process connector) 6.2 45°
E (Discharge connector) 5.0 21°
Connector tolerance ±0.09, on 5.0 +0.12/+0.20 -

Connector Material: Cu-plated steel | Al cap

Performance Data - Refrigerant R134a

Capacity (EN 12900 Household/CECOMAF)

rpm \ °C 24V DC, static cooling [watt] Compressor speed [rpm] Resistor (R1) [Ω] Motor speed [rpm]
-30 -25 -23.3 -20 -15 -10 -5 0
2,500 35.2 49.8 55.3 67.0 87.3 112 140 150 2,500 0 AEO
3,100 41.9 59.2 65.8 79.8 104 133 168 180 3,100 101N0390 with AEO 451 2,500
3,800 50.1 70.8 78.7 95.4 125 159 200 220 3,800 867 3,100
4,400 54.9 78.1 86.8 105 138 176 221 235 4,400 1700 4,400

Capacity (ASHRAE LBP)

rpm \ °C 24V DC, static cooling [watt] Compressor speed [rpm] Resistor (R1) [Ω] Motor speed [rpm]
-30 -25 -23.3 -20 -15 -10 -5 0
2,500 43.7 61.8 68.6 83.1 108 138 174 185 2,500 0 AEO
3,100 52.0 73.4 81.6 98.8 129 165 208 220 3,100 101N0390 with AEO 451 2,500
3,800 62.1 87.8 97.5 118 154 197 248 260 3,800 867 3,100
4,400 68.1 96.7 108 130 171 218 274 285 4,400 1700 4,400

Power Consumption

rpm \ °C 24V DC, static cooling [watt]
-30 -25 -23.3 -20 -15 -10 -5 0
2,500 38.4 47.9 51.2 57.8 68.2 79.5 91.9 98.0
3,100 46.9 58.9 62.9 70.8 83.4 97.3 113 119
3,800 57.5 72.0 76.9 86.5 102 119 139 147
4,400 66.3 83.5 89.2 100 118 138 161 170

Current Consumption (for 12V applications the following must be doubled)

rpm \ °C 24V DC, static cooling [A]
-30 -25 -23.3 -20 -15 -10 -5 0
2,500 1.6 2.0 2.1 2.4 2.8 3.3 3.8 4.0
3,100 1.9 2.4 2.6 3.0 3.5 4.1 4.7 4.9
3,800 2.4 3.0 3.2 3.6 4.3 5.0 5.8 6.1
4,400 2.8 3.5 3.7 4.2 4.9 5.8 6.7 7.0

COP (EN 12900 Household/CECOMAF)

rpm \ °C 24V DC, static cooling [W/W]
-30 -25 -23.3 -20 -15 -10 -5 0
2,500 0.92 1.04 1.08 1.16 1.28 1.40 1.53 1.60
3,100 0.89 1.01 1.05 1.13 1.25 1.37 1.48 1.53
3,800 0.87 0.98 1.02 1.10 1.22 1.34 1.44 1.49
4,400 0.83 0.94 0.97 1.05 1.16 1.27 1.37 1.41

COP (ASHRAE LBP)

rpm \ °C 24V DC, static cooling [W/W]
-30 -25 -23.3 -20 -15 -10 -5 0
2,500 1.14 1.29 1.34 1.44 1.59 1.75 1.90 2.00
3,100 1.10 1.25 1.30 1.40 1.55 1.70 1.85 1.93
3,800 1.07 1.22 1.27 1.37 1.52 1.66 1.80 1.87
4,400 1.02 1.16 1.21 1.30 1.45 1.58 1.71 1.77

Test Conditions

Parameter EN 12900/CECOMAF ASHRAE LBP
Condensing temperature 55°C 54.4°C
Ambient temperature 32°C 32°C
Suction gas temperature 32°C 32°C
Liquid temperature no subcooling 32°C

Accessories for BD80F

Wiring Diagram and Connections

Power supply:

Connections:

Secop Gateway (105N9518 V01.02): Connects PC to ECU (TOOL4COOL® or display) or Gateway to LÍN and C.

Interface connections: D/I and C (TOOL4COOL® or display).

Optional connections:

Resistor usage: R1 = speed selection, R2 = battery protection I.

Note: Do not connect UBAT to LINC when using D/I on BD-Products.

Operational Errors

Error code Error type
6 Thermostat failure (If the NTC thermistor is short-circuit or has no connection).
5 Thermal cut-out of electronic unit (If the refrigeration system has been too heavily loaded, or if the ambient temperature is high, the electronic unit will run too hot).
4 Minimum motor speed error (If the refrigeration system is too heavily loaded, the motor cannot maintain minimum speed at approximately 1,850 rpm).
3 Motor start error (The rotor is blocked or the differential pressure in the refrigeration system is too high (>5 bar)).
2 Too many start attempts or fan over current (Too many compressor or fan starts in short time or fan current higher than 0.5A avg).
1 Battery protection cut-out (The voltage is outside the cut-out setting).

Service and Repair Information

Instructions for Electronic Units are available for download on www.secop.com.

Service/Repair Precautions:

Refrigerant Handling:

Compressor Types:

Disclaimer

Secop GmbH. Lise-Meitner-Straße 29 • 24941 Flensburg, Germany • Tel: +49 46149410 • www.secop.com

Secop accepts no responsibility for possible errors in catalogs, brochures, and other printed material. Secop reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary to specifications already agreed. All trademarks in this material are the property of the respective companies. Secop and the Secop logotype are trademarks of Secop GmbH. All rights reserved.

PDF preview unavailable. Download the PDF instead.

single-pack-195B4141 GPL Ghostscript 10.00.0 Adobe InDesign 17.4 (Windows)

Related Documents

Preview Secop BD80F 12/24V DC PM Compressor Technical Specifications and Performance Data
Detailed technical specifications, performance data, and operational information for the Secop BD80F 12/24V DC PM compressor, compatible with R134a and R1234yf refrigerants.
Preview Secop BD80F 12/24V DC PM Single Pack Compressor - Technical Data and Specifications
Detailed technical specifications, performance data, and operational information for the Secop BD80F 12/24V DC PM compressor, including capacity, power consumption, and wiring diagrams.
Preview Secop Mounting Accessories - Types of Packaging and Parts List
A product bulletin from Secop detailing mounting accessories, including types of packaging, part codes, dimensions, and associated compressor series. It also provides a parts list with diagrams for common mounting configurations.
Preview Secop SC12G Compressor Technical Data and Specifications
Comprehensive technical data, specifications, and performance tables for the Secop SC12G compressor, including electrical accessories, wiring diagrams, and operational limits.
Preview Secop BD50F Compressor: Technical Specifications and Performance Data
Detailed technical specifications, performance data, and application information for the Secop BD50F compressor, including 12/24V DC and 100-240V AC models. Covers cooling requirements, motor details, dimensions, and electrical connections.
Preview Secop BD35F 12/24V DC PM Compressor Specifications and Performance Data
Detailed technical specifications, performance data, and application information for the Secop BD35F 12/24V DC PM compressor, including electrical requirements, cooling performance, and operational error codes.
Preview Secop BD35K 12/24V DC PM Compressor - Technical Specifications and Information
Detailed technical specifications, application data, and service information for the Secop BD35K 12/24V DC PM compressor, including electrical and mechanical properties, performance charts, and safety guidelines.
Preview Secop BDN45F-A DC Compressor R134a, R1234yf 12/24V Technical Data
Technical specifications and performance data for the Secop BDN45F-A Direct Current Compressor, compatible with R134a and R1234yf refrigerants, operating on 12/24V DC. Includes performance tables, electrical specifications, dimensions, and brazing instructions.