30m Extension hose No.351A-30 Instruction manual

FOR SAFE OPERATION

Read this manual, the instruction manual of your Gastec Gas sampling pump, and the instruction manual of your Gastec Gas detector tube carefully.

If not observed, injuries to the operator or damage to the product may result.

⚠️ CAUTION

  • When breaking the tube ends, keep away from eyes.
  • Do not touch the broken glass tubes, pieces and reagent with bare hand(s).

? NOTE

  • For maintaining performance and reliability of the test result.
  • Use only Gastec Gas Sampling Pump (GV-100 or GV-110).
  • Refer to the instruction manual of your Gastec Gas Detector tube for use temperature and humidity range.
  • Avoid sunlight, acids, and alkaline materials.

Specifications

Product name30 m Extension hose
Product codeNo.351A-30
Length30m±2%
Outer / Inner diameterΦ5 mm / Φ1.5 mm
Weight900g (approx.)
Applicable withGASTEC Gas sampling pump model GV-100 or GV-110.
Optional partsRubber shroud No.358

Diagram

The diagram illustrates the components of the extension hose assembly. It shows a metal clamping nut connecting to a rubber inlet, which leads to a nipple. A tube tip breaker is also visible. The hose itself is connected via a metal retaining nut to what appears to be the pump head. An optional rubber shroud is also depicted.

MEASUREMENT PROCEDURE

Read the instruction manual of your Gastec Gas sampling pump and the instruction manual of your Gastec Gas detector tube carefully.

  1. Replace the rubber inlet flange clamping nut of the sampling pump by the metal clamping nut of the extension hose. The metal clamping nut should be firmly tightened to eliminate leakage caused by poor seal between the flange of the rubber inlet and the pump body.
  2. Insert the nipple of the extension hose securely into the pump inlet.
  3. Tighten the metal retaining nut firmly and fix the tubing on the pump head.
  4. After breaking off tube tips, place the tube into the rubber shroud of the extension hose. The tube must be attached in the holder so that sample is drawn into the pump in the direction of the arrow (▶) printed on the tube.
  5. When use of twin tube, connect rubber tube shroud No. 358 which is sold separately.

Sampling Time and Correction Factors

When this extension hose is used, sampling time may differ from the detector tube's instruction manual. Correction factors may also need to be applied to tube readings. This section provides a chart detailing sampling times for both 1 pump stroke (100mL) and half pump stroke (50mL), along with applicable correction factors for various gases and vapors when using the No. 351A-30 extension hose. It is important to multiply the correction factors for temperature, humidity, pump strokes, extension hose, and atmospheric pressure as necessary. Refer to the specific Gastec Gas Detector tube manual for detailed information on temperature, humidity, and pump stroke corrections.

Currently, the detector tubes listed in the original document are applicable to the No. 351A-30. For tubes not listed, please contact Gastec representatives.

WARRANTY

If you have any questions regarding gas detection and quality of the products, please feel free to contact your Gastec representatives.

Manufacturer: Gastec Corporation

Address: 8-8-6 Fukayanaka, Ayase-City, Kanagawa 252-1195, Japan

Website: https://www.gastec.co.jp

Telephone: +81-467-79-3010

Facsimile: +81-467-79-3979

Printed in Japan

Models: 351A-30, 30m Extension Hose

File Info : application/pdf, 4 Pages, 906.73KB

PDF preview unavailable. Download the PDF instead.

2114 ext 14 en 0

References

GASTEC CORPORATION Adobe PDF Library 20.13.106

Related Documents

Preview Gastec Gas Sampling Pump GV-100S and GV-110S Instruction Manual
Comprehensive instruction manual for Gastec Gas Sampling Pumps GV-100S and GV-110S, covering safe usage, operation, maintenance, and troubleshooting for accurate gas detection.
Preview Gastec 126L Chlorobenzene Detector Tube: Instructions and Specifications
Comprehensive instructions and specifications for the Gastec 126L Chlorobenzene Detector Tube, detailing safe operation, measurement procedures, temperature/humidity/pressure corrections, and interference information.
Preview Gastec No. 92L Acetaldehyde Detector Tube: Instructions and Specifications
Comprehensive instructions and specifications for the Gastec No. 92L Acetaldehyde Detector Tube, covering safe operation, measurement procedures, temperature/humidity/pressure corrections, interferences, and disposal guidelines.
Preview GASTEC GAP-1 Semi-fixed Gas Alarm System | Safety Monitoring Equipment
Discover the GASTEC GAP-1 semi-fixed gas alarm system. This brochure details its features, specifications, and compatibility with GASTEC wireless gas detectors (GOC-200, CM-9A-BT, GOC-100-2-BT) for effective workplace safety and gas monitoring.
Preview GASTEC GSP-501FT Automatic Air Sampling Pump - Features and Specifications
Comprehensive guide to the GASTEC GSP-501FT Automatic Air Sampling Pump, detailing its features, technical specifications, operation modes, accessories, and compatible detector tubes for air quality monitoring.
Preview Gastec Smoke Tube Set No.550 Instruction Manual
This document provides comprehensive instructions for the Gastec Smoke Tube Set No.550, including safety guidelines, usage instructions, product specifications, set contents, disposal procedures, and warranty information.
Preview Benzene Detector Tube No. 121SP - Gastec
Technical specifications and performance data for the Gastec Benzene Detector Tube No. 121SP, used for measuring benzene concentrations in the air.
Preview GASTEC No.211H Sulphide Ion Detector Tube Instructions
Instructions for using the Gastec No.211H Sulphide Ion Detector Tube for detecting sulphide ions in waste water, including safety precautions, measurement procedures, specifications, interferences, disposal, and warranty information.