Product Overview
The Hykolity LEO Series LED Linear High Bay Light is a high-performance lighting solution designed for industrial and commercial spaces. It offers energy efficiency, durability, and superior illumination.
Dimensions and Components
The LEO Series is available in 2ft and 4ft lengths.
2ft Fixture Dimensions: Length 23.98 inches, Width 11.81 inches, Height 1.57 inches.
4ft Fixture Dimensions: Length 46.06 inches, Width 11.22 inches, Height 1.57 inches.
Included components: Linear High Bay Fixture, x2 V Hook, x2 Linked Chain.
[Image description: A diagram illustrating the dimensions of the 2ft and 4ft LED Linear High Bay Light fixtures.]
[Image description: The Hykolity LEO Series LED Linear High Bay Light fixture suspended by chains, with a UL Certified Logo.]
Advantages
- UL cUL certificate.
- Utilizes Lumileds Chip for high CRI.
- Input voltage range: 120-277VAC.
- Output constant current is adjustable via 0-10V dimming.
- No UV or IR radiation in the beam.
- Easy to install and operate.
- Energy saving with a long lifespan.
- Provides soft and uniform light, safe for eyes.
- Instant start, with no flickering or humming.
- Green and eco-friendly, mercury-free design.
Applications
- Warehouses, factories, and workshops.
- Exhibition halls and supermarkets.
Package Information
Model | Carton Size | Qty / Carton | Net Weight / Carton | Gross Weight / Carton |
---|---|---|---|---|
2FT-150W (Outer box, No Sensor) | 26*12.6*2.6IN | 1 PC | 5.3 LBS/PC | 7.5 LBS |
4FT-250W (Outer box, No Sensor) | 47.4*13.2*3.15IN | 1 PC | 10.4 LBS/PC | 14.8 LBS |
4FT-300W (Outer box, No Sensor) | 47.4*13.2*3.15IN | 1 PC | 10.6 LBS/PC | 15 LBS |
Tolerance of Carton Size: ±0.6in. Tolerance of Weight: ±10%.
Specifications
Parameter | Value |
---|---|
Color Temperature | 5000K |
Wattage | 150W, 250W, 300W |
Lumen | 19500 LM, 31250 LM, 37500 LM |
Efficacy | 130 LM/W, 125 LM/W, 125 LM/W |
CRI | >80 |
Color Consistency | ~6 Steps (or ~6 SDCM) |
UGR | <30 (X=4H, Y=8H; S/H=1; Reflectances: 70%/50%/20%) |
Diffuser Type | Frosted Lens |
Beam Angle | 105 Degree |
Input Voltage and Frequency | 120-277VAC, 50/60Hz |
PF (Tolerance: -3%) | ≥0.9 |
THD (Tolerance: +5%) | ≤20% |
Flicker Percent | ≤5% |
Mount Type | Hanging |
Driver Surge protection | L/N-PE: 6kV, L-N: 6kV |
Dimming | 0-10V continuous dimming (min. Dimming range <10%) |
Sensor Type | Daylight Sensor, Occupancy Sensor, Multifunction Sensor |
Optional Accessory | AC Motion Mircowave sensor; Emergency Power (9W/90min) |
Included Components | Linear High Bay Fixture, x2 V Hook, x2 Linked Chain |
LED Type | SMD 2835 |
Housing | IRON |
Housing Color | White |
Waterproof Rating | DAMP |
Operating Temperature | -22°F ~ 122°F |
Certification | UL listed |
Lifespan | >50,000 Hours |
Warranty | 5 Years |
Installation Instructions
Cautions:
- Do not use any electric generator to test the LED light.
- Please abide by related country, regional and local law and regulations when installing this fixture.
- Please turn off the power before installation or maintenance.
- Proper earth grounding is required to ensure safety.
Notice:
- To avoid possibility of electrical shock or fire, the installation personnel must have professional electric knowledge.
- Please wear gloves to avoid injury before installation.
- If any smoke or spark of the wire happened, please turn off the power immediately and notify relevant personnel.
- Please use listed strain relief bushing when connecting the supply cord to the outlet box.
Attention:
- Please check if there is any damage during shipping. If so, please contact manufacturer timely.
- Please read the installation instruction carefully to check whether all the accessories are complete. After confirmation, install the fixture according to installation steps.
Wiring Diagram & Instruction:
Three dimming functions are available in this high bay light:
- Constant current can be achieved by 0-10VDC dimming.
- PWM signal dimming.
- Variation of resistance unit dimming.
This product is 0/1-10V dimming; the following dimmers are recommended:
Brand | Model |
---|---|
LUTRON | NTSTV-DV |
LEVITON | DS710/IP710 |
LEGRAND | RH4FBL3PTC |
Basic Wiring Instruction:
- L: Black
- N: White
- [Ground Symbol]: Green/Yellow
- DIM +
- DIM -
(Refer to the light label for DIM+ and DIM- wire colors.)
Please choose the appropriate dimming way according to your needs. You can also choose not to use this function.
Note: The product cannot be connected to a dimming device when it's equipped with a Motion Sensor.
Installation Methods:
Choose the most suitable installation method for your needs:
A. Hanging Installation (Chain/Cable)
Step 1: Hook up the chain. Step 2: Connect the chain with the fixture. Step 3: Fix the chain on the rail and adjust the chain length as needed. Step 4: After fixing, choose a suitable wiring knock-out and connect the wires according to local standards and codes.
[Image description: Diagram illustrating the hanging installation steps.]
B. 3/4"NPT Installation
Step 1: Mount the bracket on the 3/4"NPT fitting. Step 2: Lock the fixture onto the bracket. Step 3: Connect the wires according to local standards and codes. Step 4: Lock side brackets with a screwdriver.
[Image description: Diagrams showing the mounting bracket, fixture attachment, and wiring connection for 3/4"NPT installation.]
C. Surface Mounting
Step 1: Mount the bracket on the rail or ceiling. Step 2: Assemble the lamp onto the bracket and fix it with screws. Step 3: After mounting, choose a suitable wiring knock-out and connect the wires according to local standards and codes.
[Image description: Diagrams showing bracket mounting and fixture attachment for surface mounting.]
Extra Accessory Option Installation
1. Wire Guard
Step 1: Unscrew the two screws on the front of the lamp. Step 2: Place the wire guard on the lamp and fix it with screws.
[Image description: Diagrams showing the installation of a wire guard onto the LED fixture.]
2. Motion Sensor / PIR Sensor
(Both sensors have the same installation procedure.)
Step 1: Open the face cover with a screwdriver. Step 2: Knock out the side cover, mount the sensor on the side, and perform wiring according to the sensor's instructions. Step 3: Replace the face cover with a screwdriver.
[Image description: Diagrams illustrating the installation of a motion sensor onto the LED fixture.]
Wiring Instruction for Sensors:
Motion Sensor / PIR Sensor Wiring:
- ACL (Black) -> ACL in
- ACN (White) -> ACN
- LED Driver ACL (Black) -> ACL out
- LED Driver ACN (White) -> ACN
- Dim + (Purple) -> Dim +
- Dim - (Gray/Pink) -> Dim -
- [Ground Symbol] (Green/Yellow) -> Connect to sensor ground if applicable.
3. Backup Driver
Connect the wires according to the wiring diagram.
[Image description: Wiring diagram for the backup driver, showing connections for EMERGENCY LED DRIVER and LED Normal driver.]
Backup Driver Wiring Details:
- INPUT: L (Red), N (White), AC line switch (Blue&white), Led driver L (Green).
- OUTPUT (EMERGENCY LED DRIVER): LED + (Red), LED - (Black), dirver + (Purple), dirver - (Gray), LED indicator + (Brown), LED indicator - (White).
- BATTERY YHBAL2-3.2: Battery connector.
- LED Normal driver: L (Black), N (White), G (Green/Yellow), LED+ (Red), LED- (Black), DIM+ (Purple), DIM- (Pink).
Warning / Avertissement
MIN 90 °C SUPPLY CONDUCTORS
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED. CONSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT CONDUCTOR.
LES FILS D'ALIMENTATION 90 °C MIN
CE PRODUIT DOIT ÊTRE INSTALLÉ SELON LE CODE D'INSTALLATION PERTINENT, PAR UNE PERSONNE QUI CONNAÎT BIEN LE PRODUIT ET SON FONCTIONNEMENT AINSI QUE LES RISQUES INHÉRENTS. CONSULTER UN ÉLECTRICIEN QUALIFIÉ POUR VOUS ASSURER QUE LES CONDUCTEURS DE LA DÉRIVATION SONT ADÉQUATS.
[Image description: Diagram showing the Hykolity LEO Series LED Linear High Bay Light fixture.]
HAISEN Motion Sensor (Optional Accessory)
Product Information
This motion sensor is specifically designed for Hykolity LEO series LED linear high bay lights.
Model: HD406VRH-D
Features:
- 5.8GHz microwave motion sensor with dimmable function.
- Supports various installation types: surface mounting, traditional LED high bay with aluminum reflector, UFO high bay, or linear/triproof high bay.
- Maximum installation height: 15m (49.21ft).
- Compatible with 1-10V Dimming.
- Includes remote control functionality.
- Comes with a 5-year warranty.
- IP65 rated for high altitude installation.
[Icon description: On/Off Control, Detection Area, Daylight Sensor, Hold Time, Warranty (5 years), Stand-by period, Stand-by dimming level.]
Technical Data
Parameter | Value |
---|---|
Operating Voltage | 120-277VAC, 50Hz/60Hz |
Operating Temperature | -35°C~+60°C |
Stand-by power | <1W |
Microwave Frequency | 5.8GHz±75MHz |
Microwave Power | <0.3mW |
Switching Capacity | Max, 3.0A@120Vac, 50/60Hz; Max, 2.0A@277Vac, 50/60Hz |
Detection Area | 50%/100% |
Hold Time | 5s/30s/1min/5min/10min/20min/30min |
Daylight Threshold | 2Lux/10Lux/30Lux/50Lux/80Lux/120Lux/Disable |
Stand-by Period | 0s/10s/30s/1min/5min/30min/+∞ |
Stand-by dimming level | 10%/20%/30%/50% |
Motion Detection | 0.5~1.5m/s |
Safety Standard | EN61347-1, EN61347-2-13, EN60598-1 |
Mounting Height | Max. 15m (49.21ft) |
Detection Range | Max. ø14m (45.93ft) |
IP Rating | IP65 |
Warranty | 5 Years |
Control Method | DIP Switch |
Factory Default Setting: Detection area 100%/ Hold time 5s/ Daylight threshold Disable/ Stand-by period 0s/ Stand-by dimming level 10%. Settings can be customized.
Mechanical Structure
The sensor comprises the following parts:
- Microwave Module
- Bottom Case
- Upper Cover
- Installation Hole
- Mounting Bracket
[Image description: Exploded view of the HAISEN Motion Sensor showing its mechanical components.]
Installation Method
The sensor can be installed using various methods, illustrated in the diagrams.
[Image description: Diagrams A, B, C, D showing different installation methods for the motion sensor, including dimensions and screw types.]
Wiring Diagram
The wiring diagram shows connections for the sensor to the LED driver.
Connections:
- L (Black)
- N (White)
- L' (Red)
- 1-10V- (Pink)
- 1-10V+ (Purple)
- Load
[Image description: Wiring diagram for the HAISEN Motion Sensor connecting to an LED driver.]
Detection Patterns
Ceiling Mounted & Wall Mounted Detection Patterns:
These diagrams illustrate detection areas based on mounting height and sensitivity (0.5-1.0 m/s). The highest mounting height for 100% sensitivity is 15m.
[Image description: Diagrams showing detection patterns for ceiling and wall mounting, indicating well-detected and possibly detected areas.]
DIP Switch Setting
The DIP switches control various sensor functions:
- Stand-by dimming level: Switch UP for 10%, 20%, 30%, 50% (low output in standby).
- Stand-by period: Settings for 0s, 10s, 30s, 1min, 5min, 30min, +∞ (period of low output before switching off).
- Daylight Threshold: Settings from Disable to 120Lux (sensor works only when ambient brightness is below the set lux, or always if disabled).
- Hold-Time: Settings from 5s to 30min (period of 100% brightness after motion detection).
- Detection Area: 100% (strong sensitivity) or 50%.
[Image description: Diagram showing DIP switch settings and their corresponding functions.]
Performance Scenarios
1. Automatically ON/OFF Function
- With sufficient daylight, light remains OFF even when motion is detected.
- With insufficient daylight, the sensor turns light ON when motion is detected.
- The sensor automatically turns OFF light after the holdtime when no motion is detected.
2. Daylight Disable
- When daylight threshold is set to "disable", the sensor turns light ON when motion is detected and OFF after the hold-time.
- The sensor turns light ON when motion is detected.
- The sensor keeps light ON for the holdtime period after motion leaves.
- The sensor automatically turns OFF light after the holdtime.
3. Corridor Function, Bi-level Dimmable
- With sufficient daylight, the sensor keeps light OFF even when motion is detected.
- With insufficient daylight, the sensor turns light ON when motion is detected.
- After no motion is detected, the sensor keeps light ON at 100% for the holdtime.
- After the holdtime, the sensor dims light to the standby dimming level for the standby period.
- The sensor automatically turns OFF light after the standby period when there is no motion detected.
Attention
- Please read the instructions carefully before using this product and keep them accessible for all users.
- The sensor should be installed by a qualified electrician, ensuring power is off before installation.
- Hykolity reserves the right to modify any incorrect text, images, and technical parameters.
- Any unauthorized modification is forbidden; otherwise, all guarantees will be immediately invalid.
Installation Precautions
- The microwave sensor can be installed in any lamp except those with a full metal shell.
- The detected surface cannot be shielded by metal objects.
- Ensure the microwave module is completely exposed to the outside.
- The detection surface of the sensor module must face the detection area.
- Keep the sensor away from the driver to avoid interference generation and lamp flashing.
- Wiring must strictly adhere to the wiring diagram to prevent short circuits.
Application Environment
- Suitable for indoor installation to avoid false triggering from external factors like rain, wind, or tree swing.
- Do not install in places with four metal shelters or small enclosed spaces (e.g., galvanized-iron roofs).
- Avoid mounted installation that could cause false triggers due to lamp shaking.
- Do not install near large operating machines like ventilators or ceiling fans to prevent false triggering caused by machine vibration.
User Notes
- Microwaves can penetrate walls or glass thinner than 20mm and attenuate if thicker than 20mm.
- The driver voltage should be stable and float within 10%.
- Detection area is affected by motion speed, mounting height, and movement volume.
- Conduct tests on sunny days without the lampshade, as it can affect the tested lux value.